Rebar Splice Length & Location- Tagalog Tutorial

แชร์
ฝัง
  • เผยแพร่เมื่อ 1 ก.พ. 2025

ความคิดเห็น • 35

  • @GeorgeTerrobias
    @GeorgeTerrobias 18 วันที่ผ่านมา +1

    Salamat po sa Dios sa kalóob na karunonga pinagkaloob sayo ng Dios sana marami pa po kayo tutorial for structural design ng gawin.

  • @cadworkz
    @cadworkz 5 หลายเดือนก่อน +1

    Ang galing nyo po mag explain sir ^^ dame ko natutunan. Salamat po ^^ more videos to come po hehe

  • @Damage_CTRL
    @Damage_CTRL 2 ปีที่แล้ว +1

    Ito dapat yung nag one milliom views hindi yung walang ka kwenta kwentang mga bloggers na wala naman katuturan.

  • @reynaldosira5770
    @reynaldosira5770 2 ปีที่แล้ว +1

    I'm your regular follower.for every new upload. Very informative

  • @arielescala7991
    @arielescala7991 2 ปีที่แล้ว +1

    Maganda ito para maeducate na rin ang mga nagpapagawa ng bahay na kapos sa budget at di na kayang maghire ng civil engr, importante talaga kasi maging economical at safe ang structure.

  • @kimberlymaesantos1660
    @kimberlymaesantos1660 2 ปีที่แล้ว +1

    Hi sir, please cover din po yung commercial, procurement and QS topics. Maganda po kasi explanation nyo doon sa bid evaluation na video. Salamat po

  • @almajididjas7515
    @almajididjas7515 2 ปีที่แล้ว +1

    Hi sir i hope gumawa rin kayo ng explanation about sa middle third ruling na usually ginagamit for pouring strip or construction joint. Salamat 😊

  • @emsnts1125
    @emsnts1125 2 ปีที่แล้ว +1

    Very well explained!! 👏🏼👏🏼

  • @mrtams
    @mrtams 7 หลายเดือนก่อน +1

    Thank you God bless po

  • @aeriskabkr1110
    @aeriskabkr1110 2 ปีที่แล้ว

    Thanks, sa explanation sir, ganyan ang manner ng splicing na observed namin sa site.. Sir, tanong ko lang po kung paano at saan ginagamit ang formula for Lap Splice Lengths of Deformed Bars and Deformed Wires in Tension? nabasa ko lang po sa NSCP. Ang ginamit po dito na formula sa video is for Lap Splice Lengths of Deformed Bars and Deformed Wires in Compression

    • @jsdesign_engineeringtv3633
      @jsdesign_engineeringtv3633  2 ปีที่แล้ว +2

      As much as possible we avoid tension splice, but in rare cases always check moment diagram. Ensure all the required rebars are in-place within the tensile zone. Thanks

  • @jornlazatin8631
    @jornlazatin8631 ปีที่แล้ว

    Thank you sir, new learnings ako palagi sa channel nyo.
    Question po, yung sinasabi po nila na 40d at 50d saan po galing ung splicing na yon?
    Thank you po.

  • @CheapTrick88
    @CheapTrick88 2 ปีที่แล้ว +1

    question sir.. pareho lang po ba ang splicing at location ng extra bar pag sa footing tiebeam at grade beam? sabi kasi ni architect ay reverse sila pag nasa ibaba sila di pareho yung dinadala nilang load.

  • @UwU_UwU_69
    @UwU_UwU_69 2 หลายเดือนก่อน +1

    Allowed po bang gumamit ng 12mm rebars for beams on two storey residential building? Thank you po.

    • @jsdesign_engineeringtv3633
      @jsdesign_engineeringtv3633  2 หลายเดือนก่อน

      @@UwU_UwU_69 minimum 16mm main bars, baka hindi ma approve sa building permit if you use 12. Thanks

    • @UwU_UwU_69
      @UwU_UwU_69 2 หลายเดือนก่อน

      @@jsdesign_engineeringtv3633 salamat po sir. Nag fail po kasi pag 16mm Ang ginagamit sa design pero pass naman po pag 12mm ang ginamit. Di ko lang mahanap sa NSCP kung may section na nag sasabi na prohibited to use 12mm rebars for beams and column.
      Maraming salamat po sir. Godbless po.

    • @jsdesign_engineeringtv3633
      @jsdesign_engineeringtv3633  2 หลายเดือนก่อน

      @UwU_UwU_69 try to increase numbers of rebars in critical section but make sure to check clear space between bars, or increase beam depth. Thanks

  • @richardneile.salalima54
    @richardneile.salalima54 10 หลายเดือนก่อน

    thank you sir

  • @jeynelsarraga4691
    @jeynelsarraga4691 ปีที่แล้ว

    Sir pwde rin po ba ung 40d pra s slicing...???

  • @clutchplays4116
    @clutchplays4116 2 ปีที่แล้ว

    Thank you Engr for the information. Just want to share na nagbabago po ang splice location if the member is intended for seismic purposes like girders. Btw po anong section po sa NSCP yung splice length formula? Thank you po

    • @jsdesign_engineeringtv3633
      @jsdesign_engineeringtv3633  2 ปีที่แล้ว

      Thanks for the added info. Check mo lang sa rebar detailing there's a lot of useful information there.

    • @renzelesteban3113
      @renzelesteban3113 2 ปีที่แล้ว

      Same din yung query ko sana sa query mo, Sir Clutch.

  • @bandz5433
    @bandz5433 6 หลายเดือนก่อน

    Sir sa lapping po ano po standard if contenues yong bakal? Salamat if masagot

    • @jsdesign_engineeringtv3633
      @jsdesign_engineeringtv3633  6 หลายเดือนก่อน +1

      @@bandz5433 for tension splice use 50 bar diameter

    • @bandz5433
      @bandz5433 6 หลายเดือนก่อน

      @@jsdesign_engineeringtv3633 okay sir salamat po.

  • @aeclint
    @aeclint 7 หลายเดือนก่อน +1

    So 300mm po min. ng lap splicing po ba sir?

    • @jsdesign_engineeringtv3633
      @jsdesign_engineeringtv3633  7 หลายเดือนก่อน +1

      For compression splice use 28 x bar dia.

    • @aeclint
      @aeclint 7 หลายเดือนก่อน +1

      @@jsdesign_engineeringtv3633 Thank you po! 😊

  • @pong3753
    @pong3753 11 หลายเดือนก่อน

    Sir sa NSCP po bawal naman po mag splice sa 2d sa bottom bars malapit sa face ng column..

  • @Ralphdennis417
    @Ralphdennis417 2 หลายเดือนก่อน

    Sa compression daw maganda, pero posible nmn na wala xD

  • @alexandermunasque2584
    @alexandermunasque2584 2 ปีที่แล้ว

    hindi ba bawal mag splice sa support sir?

    • @jsdesign_engineeringtv3633
      @jsdesign_engineeringtv3633  2 ปีที่แล้ว

      As long as you are within the comp. zone and let the aggregate pass through its good. Thanks

    • @alexandermunasque2584
      @alexandermunasque2584 2 ปีที่แล้ว

      @@jsdesign_engineeringtv3633 thank you Sir.

    • @stephencano2737
      @stephencano2737 2 ปีที่แล้ว +1

      for Special moment frames bawal mag splice sa support .. splicing is only allowed after twice the depth of beam from the support at 50 percent per beam cross section.. yung explanation ni sir sa splicing location at bottom bars at the support is only applicable for beams/girders recieving gravity loads only.. please see NSCP