Bhai ji mere pas lamunos nxt 3.75kw pcu hai . livguard 165 ah solar battery lagi hai.2 kw panel laga hai.rat me 3_4baje k aas pas inverter baith jata hai .load 300 watt chalta hai.iska kya karne hai.bhai ji boost voltage aur flote voltage kya rakhe.current settings kasse aur kitna kare .pls suggest.i use this inverter on last 15 day.pls reply
Sir we have 10 kw solar nxt 150 ah tub battery . So boost voltage and float voltage kya rahega. Pls saari setting kya rakhnhi chahiye ye bhi bata dijiye
Thank you for Detail Information, Can you clear some doubt..... 1. You forget to show Battery reserve thing, Matlab ki mujhe 70% se jyada battery discharge nehi karna battery mein, Is it possible in this NXT PCU ? 2. Suppose my running load is 1.4 kw, Solar Panel Generating 1kw at the moment, So kya PCU pura load Grid ko transfer kar dega ya fir 1k w solar se lega and baki 400 watt Grid se lega aisa possible hai ? Ya fir ye PCU pura load either Solar se chalega ya fir grid se no Sharing ? 3. 3kw off grid system mein 2x 1.5 Ton AC nehi chal sakta I know, but Aajkal ke Dual Inverter AC aa gaye hain. 1.5 Ton ke hone se bhi agar Power saving mode par chalein all time wo higest 1kw tak enery consume karta hai, So kya 2x AC 1kw+1Kw load se Suppose, 3 kw off grid solar system se only Day time 2x 1.5 ton Inverter AC chalaya ja sakta hai ? 4. Connection ke baare mein bataiye, (a) MCB kitna lagana hai, Grid current se PCU ko power ke beech mein MCB lagana hai ? PCU bypass ke liye kya karna hoga? mera matlab ghar ka load pcu se na jakar Grid se jaye incase PCU mein problem ho. (b) Solar to Pcu ke beech mein MCB laga sakte hain kya ? incase during Thunder storm Solar se power off karde to save PCU 5. PCU 24x7 hamesha chalta rahega to kharap nehi hoga kya ? and PCU ko band kaise karte hain ? suppose mujhe Kuch days ke liye Solar nehi chaiye Sirf Grid se current chaiye to kya karna hoga ? Thank you for answering
Good man can you please let me know if i dont connect a battery will the load get shared from the solar panel and grid if i exceed the wattage produced by solar panel.
7.5 kva solar inverter shows overload fault. However no light is in outside and all lights r off. What is the reason. When light grid comes all works good but when grid off sudden all lights off and show overload
100ah ki battery ka voltage setting kitna hona chaiye . Aur battery ko jaldi charge karne ka koi setting when grid or solar available . Koi setting jo battery ko 80 percentage discharge hone se bachaye in case of solar.
Luminous nxt 3. 75k ko kaise phone ki app k sath connect Kia jata hai woska video agar dey dete toh bohot aches hota.. main Bangladesh se hoon.. mere pass ek luminous solar 3. 75 nxt inverter hai but wo mere phone se connect neyhi ho raha hai app k jariye
Please tell agar ek ya do solar pannel khrab h to hum kaise pata lagai???
Bhai ji mere pas lamunos nxt 3.75kw pcu hai . livguard 165 ah solar battery lagi hai.2 kw panel laga hai.rat me 3_4baje k aas pas inverter baith jata hai .load 300 watt chalta hai.iska kya karne hai.bhai ji boost voltage aur flote voltage kya rakhe.current settings kasse aur kitna kare .pls suggest.i use this inverter on last 15 day.pls reply
Sir we have 10 kw solar nxt 150 ah tub battery . So boost voltage and float voltage kya rahega. Pls saari setting kya rakhnhi chahiye ye bhi bata dijiye
Bina battery ke bhi chal sekta hai kya sir
Really good video. Very helpful. Thanks a lot.
Thank you for Detail Information, Can you clear some doubt.....
1. You forget to show Battery reserve thing, Matlab ki mujhe 70% se jyada battery discharge nehi karna battery mein, Is it possible in this NXT PCU ?
2. Suppose my running load is 1.4 kw, Solar Panel Generating 1kw at the moment, So kya PCU pura load Grid ko transfer kar dega ya fir 1k w solar se lega and baki 400 watt Grid se lega aisa possible hai ? Ya fir ye PCU pura load either Solar se chalega ya fir grid se no Sharing ?
3. 3kw off grid system mein 2x 1.5 Ton AC nehi chal sakta I know, but Aajkal ke Dual Inverter AC aa gaye hain. 1.5 Ton ke hone se bhi agar Power saving mode par chalein all time wo higest 1kw tak enery consume karta hai, So kya 2x AC 1kw+1Kw load se Suppose, 3 kw off grid solar system se only Day time 2x 1.5 ton Inverter AC chalaya ja sakta hai ?
4. Connection ke baare mein bataiye,
(a) MCB kitna lagana hai, Grid current se PCU ko power ke beech mein MCB lagana hai ? PCU bypass ke liye kya karna hoga? mera matlab ghar ka load pcu se na jakar Grid se jaye incase PCU mein problem ho.
(b) Solar to Pcu ke beech mein MCB laga sakte hain kya ? incase during Thunder storm Solar se power off karde to save PCU
5. PCU 24x7 hamesha chalta rahega to kharap nehi hoga kya ? and PCU ko band kaise karte hain ? suppose mujhe Kuch days ke liye Solar nehi chaiye Sirf Grid se current chaiye to kya karna hoga ?
Thank you for answering
Anil ji aapne jo sawaal kiye hai whi sawaal mere bhi hai.....agar aapko pta chl gye ho toh please bta dejeyega.....dhanayawaad
Hmne tx5kva install kiya h jo unit export nahi kr raha h or isko net meter se conection kese kre ye bataye plz..
Does it comes with grid feed mode
Please make a video on voltage settings... Agar mujhe battry grid se charge nhi krni to kaise off kr sakte h? Please reply
Bhai saab btaye float voltage our comm.setting
Current settings ke baare me vedio bana de
Your video is very informative. Thanks a lot.
Can you tell me settings for 3.75 kwa solar inverter same model from luminous with battery 150 ah
Sir isse bijli export kar sakte he
how much boost and float voltage for 150ah exide tubular battery
I have 150ah battery 22.5kva pcu
How much iset floot voltage & boost voltage
Good man can you please let me know if i dont connect a battery will the load get shared from the solar panel and grid if i exceed the wattage produced by solar panel.
Its possible to ongrid solar system
Bhaya bin a solar ke only 230 ac supply me I sika setting kese hoga
7.5 kva solar inverter shows overload fault. However no light is in outside and all lights r off. What is the reason. When light grid comes all works good but when grid off sudden all lights off and show overload
100ah ki battery ka voltage setting kitna hona chaiye . Aur battery ko jaldi charge karne ka koi setting when grid or solar available . Koi setting jo battery ko 80 percentage discharge hone se bachaye in case of solar.
Kiya yeh inverter 170 volt grid per Nahi charge kerta hai۔۔۔۔۔
Sir please make a video on float and boost voltage
Kindly inform me about what is the right method to make 4 /24 volt panels 48 volt for one kv off gird pcu thanku
3.75kva 4nos 150ah battery-boost and float voltage how much set karna hai..current kithene amps set karna hai.. please reply
Boost 58v and float 57v
What are the reason to show short circuit fault and how to reset overload trip
How to calculate the load please teach me
क्या सोलर गर्मियों में कम जनरेशन बनाता है
Sir mere pcu me bar bar fault light on ho ja raha hai aur battery low dikha raha hai
Can I use this system to save some electricity
Yes
Luminous nxt 3. 75k ko kaise phone ki app k sath connect Kia jata hai woska video agar dey dete toh bohot aches hota.. main Bangladesh se hoon.. mere pass ek luminous solar 3. 75 nxt inverter hai but wo mere phone se connect neyhi ho raha hai app k jariye
Ok thanks bro,... but now luminous new nxt model ma mobile app Bala function nahe araha india ma old model ma aratha
@@electricallearner thank u for replying bro 🙂
Are sir 10 kw luminous pcu ko start karte hi falt dikha rha h out put ni de ra
Please tell me what is the complete cost of this 6kva system, including battery, panels and structure. I am from Kolkata
Minimum 2.6 lakh
Sir NXT 3.75 ka full setup price with stracture and installation total kitna amount hoga
please voltage setting 3.75 kva ki
What is boost and float voltage , please make a video
Bro please tell how to set battery discharge voltage to switch on grid
Did u find out?
Sir inverter y
Es Sistam Me sabmasibal 150hp Ka Motar Chalegi.
What is float voltage and boost voltage , please make a video
Sir float voltage and boost voltage
Plz... Make a video
7.5 kw sar jab great charge Karta Hun tu load 30 amp leta hai kam karna chahta hun
Solar of hogai to on kaise korenge 🙏🙏
Apna conection dikha do bhai
solar luminous 6 kw mri not working video
My PCU fluctuates while Grid is on
Becoz of voltage fluctuations
@@priyashukla2808 nope dear. This model is shit
Mrl not working
Sir please tell me
कबाड़
Call