You shouldn't use the long file to clean the battery, .If there is short circuit battery could blast like Bomb, use only emery paper to clean the terminals. The method of testing the UPS before buying new battery is good. 👍👍👍
12 Volt ka hoga to achha rahega. UPS ka battery 12 V ka hai to adapter 12 V hona chaiye, fir output me 230 V AC hi milega. Warna 10V or 16 V ka laptop adapter se vi Kam ban sakta ha. Fir output Voltage 230V se kam ya zada milega. Mai suggest karunga, ap 12 V ka adapter hi use kare.
Well demonstrated video But problem is anyone cannot fix it, especially without those tools 😢 By the way আপনি কি জানেন কলকাতার চাঁদনী চকে সারায় কি না বা কত নেবে? আমার UPS এ মনে হচ্ছে battery গেছে, আবার charging issue ও থাকতে পারে।
I have an Eaton Nova AVR 1250 Ups thats not coming on or charging the battery!After following your instructions and connecting the power my Ups comes on BUT only for about 5 seconds seconds and then goes off again!What can be the problem?Thanx!
Good work done ✅👏👏👏 I really need your help. Pls am repairing a 10KVA ups with low battery alarm, even though the batteries are all replaced. 16 batteries in total, summing to 213v from multimeter check, but what appear on ups screen is 174v . Kindly assist me , what could be the possible cause of the fault which affecting the voltage failure sensing. Thank you 🙏
I have issue with my UPS which it only gives 150v (low voltage) supposed to be it should release 220v. Note that this has new replaced battery. Any idea what needs to be done to get this fixed?
Hi Sir, I have vguard sesto 600 ups which supports 300 watt. But when I connect led tv of 173 watt , ups gets shut down. But when I give 50-60 watt load, it does not get shut down. What can be the cause of shutdown ? Can you please reply?
Hi Bro, wanna ask how can i turn ups (without battery) work like avr system, cause I have 1 ups and battery faulty, but I no need to use battery now, so I think want to turn it as avr, but once I removed the battery the ups cannot on, even I plugged the 230V power.
Yes, battery can be repaired by replacing the lead and acid. But you can not do it yourself. It is very much risky. It is better that you can give it to the battery dealer and buy a new one by adjusting some amount. Or you can sell the old battery directly to the dealer.
hye bro,my ups battery prob low voltage,when i try put power same like u use,output voltage higher then 230,i check with multimeter,got voltage is 350v..what a problem..
Hi, my ups turns on & works but the battery only last for 20min powering a low wattage device(modem). I assumed it was the batteries so removed them for replacement but on testing they were healthy. What else could be causing this
Hii I have a 12V adaptor But it's other specifications are not exactly as same as your water purifier's specs. Can you please tell me if I can use that ?
Please check the output current in your 12 V adaptor. If it is too much higher than you are using, then you should not use this, otherwise you can use.
@@PranabsLab Yes I did everything as shown in your video and the UPS started up, but I don't have a Multimeter to check Output. Pranab hi, kya aisa ho sakta hai ki battery sahi hai, output bhi sahi hai Lekin l mere power cable me hi problem ho ?
My ups is not giving backup. Maximum 40 sec backup. But few days ago suddenly ups was given 30 min backup. This is happen only one time. Battery output voltage 24 volt. What is the fault?
Bro my ups works properly when there is no load connected to it, it beeps properly at regular intervals and all. But when i connect an ac load to its output it instantly shuts down, any reason as to why this happens.. please help
Dada, amar ups normally choley, kintu kokhono-kokhono cholte-choltey hotath battery mode a chola suru kore dei (mane current na thakley r ki jamon choley).. tumi ki bolte parbe erokom kano hoe? Amar ghorer voltage akdom thik achey.😅
I am trying to charge a UPS from another UPS. When I plug one UPS into the other one it is not charging the battery, however the AC power seams to go through the first one. I have tried 3 UPS, none of them will charge the first UPS. Why is this?
@@PranabsLab Hey friend, thanks for your answer. Let me explain the situation more. I am using this system in my car where I live right now. So my power source is my 12 Volt battery in my car. The first UPS is an APC 600 unit that is hooked up to my Car battery with wires. The second UPS is a Cyber-Power 1500VA unit which has two batteries at 24 Volts. So I can not charge the second UPS from my car, but I should be able to charge it from my APC 600, by simply plugging it into the 120 Volt outlet, right? The problem is that the Cyber-Power UPS does not sense that I have plugged it into the APC 600. But when I plug it into the house outlet, everything works fine. I don't understand why this is happening. I have also tried to plug in a 3rd UPS and that does not sense either that it has been plugged in. But if I plug in my stereo or laptop, for example, it works fine. What could be the problem? Thanks!
The problem is that, your APC 600 is connected with 12V battery of your car and your Cyber Power is of 24V supply which is incompatible with the charging UPS. That's why your Cyber Power ups is not charging.
ভাই, আমার UPS charging করার সময় Motherboard প্রচন্ড গরম হয়। কোনো পার্টস এ কি সমস্যা হয়েছে? প্রথমে ভেবেছিলাম চার্জের সময় হয়তো ট্রান্সফরমার বা ব্যাটারি গরম হয়, কিন্তু ভালো করে খেয়াল করে দেখলাম motherboard গরম হচ্ছে। দুটি cooling fan লাগিয়েছি। কিন্তু পার্মানেন্ট solution চাচ্ছি। UPS : 1200VA double battery. Battery : 12v 9 Ah ( 2 battery)
আগে এই সমস্যা ছিলোনা৷ হঠাৎ করেই এরকম সমস্যা৷ ১ বছরের মতো ব্যবহার করেছিলাম তারপর ৩-৪ বছর আর ব্যবহার করা হয়নি৷ এখন নতুন ব্যাটারি লাগিয়ে ব্যবহার করছি। শুধু চার্জ নেয়ার সময় গরম হয়, ব্যাকাপ দেয়ার সময় একটুও গরম হয়না
ওটার জন্যেই বোর্ড হিট হচ্ছে। ইলেক্ট্রনিক্স এলিমেন্টস গুলো খুব সেনসিটিভ হয়। যে রেটিং এর ব্যাটারি ছিল ওরকমই লাগান। এরকম করে ব্যবহার করতে থাকলে, হঠাৎ সার্জ এলে আপনার ব্যাটারি আর বোর্ড দুটোই যাবে।
@@PranabsLab in house no earthing wiring but in starting ups don't do shock while touching battery terminals but now I get a current shock while the touching battery terminals why it's happening??
বিশ্বাস করুন আপনার চ্যানেলে ইংলিশ শিখতেই গিয়েছিলাম, এই টপিকের উপর কোনো ভিডিও দেখতে পেলাম না তাই বেল আইকনে "জোড়ে থাপ্পড়" মারতে পারলাম না subscribe তো দূরের কথা। 🙂
@@PranabsLab english man bangla te likheche..😜😜😜 ato rag valo na mona.. Banglai valo to banglai video bana.. Besi lok dekhbe.. Bojhate o parbi valo kore...
Bro's English is more than good enough to be understood by any other reasonably intelligent English speaker. We should be thankful for him sharing his knowledge.
I'm curious, how does the UPS actually work? Wouldn't it damage your 12v adapter, when you also connect the 220v AC? In my understanding, when you connect to a 220v power outlet, then it will charge the battery which in this case, your ADAPTER. Wouldn't it damage the adapter?
we need to first check o/p voltage of atleast 220AC by connecting 12v adapter instead of battery. This shows that circuit is working fine. Video is good and I appreciate his efforts in explaining everything.
Don't care about those, your English is good and completely understandable.
Nice comment 😁😁😁😁👍
Always the indian guy to the rescue. Thanks a lot man. I did the same. Now it's working.
Watching here nice tutorial vedio thank you for sharing this video
Great, quick and simple video. Thanks a lot!
You shouldn't use the long file to clean the battery, .If there is short circuit battery could blast like Bomb, use only emery paper to clean the terminals. The method of testing the UPS before buying new battery is good. 👍👍👍
Thanks bro i can now repair my ups 😊❤❤❤❤❤❤❤
Thanks for the tutorial🙏🏼 Very usefu too . I will change the battery on my UPS
Wow !! thank you for making this video
Very good explanation. Thanks for sharing the knowledge. 👍
Can I use this UPS for my internet router during brownout? Thank you for the tutorial on how to know if the UPS is not working...
Obviously 🥰🥰
Thank u. Im from Sri Lanka
Video te apnar gola sune valo laglo sir. I'm one of those lucky people who attained live class from you locally.
A good way to test if theres any problem with ups transformer or pcb board.
arre bangali bangali!
khub bhalo laglo video ta!
গর্বিত বাঙ্গালী 🥰🙏🏽
Great English bro you are using technical words 😊
Kya adapter 12 volt hi chahiye 10v or 16v laptop charger ko use kr skte hai kya
12 Volt ka hoga to achha rahega. UPS ka battery 12 V ka hai to adapter 12 V hona chaiye, fir output me 230 V AC hi milega.
Warna 10V or 16 V ka laptop adapter se vi Kam ban sakta ha. Fir output Voltage 230V se kam ya zada milega.
Mai suggest karunga, ap 12 V ka adapter hi use kare.
very nice tutorial.
Great one
Well demonstrated video
But problem is anyone cannot fix it, especially without those tools 😢
By the way আপনি কি জানেন কলকাতার চাঁদনী চকে সারায় কি না বা কত নেবে? আমার UPS এ মনে হচ্ছে battery গেছে, আবার charging issue ও থাকতে পারে।
হ্যাঁ চাঁদনী চকে সরানো হয়। কত নেয় সেটা ওরাই বলবে। আপনি সরানোর আগে দরাদরি করতে ভুলবেন না। পারলে দাঁড়িয়ে থেকে সরানোর চেষ্টা করবেন
Very helpful video. Thanks alot.
Good🎉
how long it last in hour of the ups
It depends on how much load you are applying. If load is more then backup time will less and vice versa.
Can i use a 20v 2.25A external power supply 😢
No. If the battery voltage is 12V then the Power supply should be 12V too
@@PranabsLab thank you
I will try it also.
Super explanation.thanks
May i know which ups is favorable for desktop & what is the price for a frontech 12v 7.5 AH battery?
Approx INR 700 to 900
Nice and Thanks Bro.❤
youre good tip of the hat
Nice bro👍👍👍
Very useful
❤❤ salute bro..
Good job keeping going 👍👏
Thanks 🙏🏽
How much ups battery cost ?
About 750-800 INR
I have an Eaton Nova AVR 1250 Ups thats not coming on or charging the battery!After following your instructions and connecting the power my Ups comes on BUT only for about 5 seconds seconds and then goes off again!What can be the problem?Thanx!
1.7 Amp Output Adaptor se kya ye ON ho jayega???
Please reply zarur dena
Ho jayga
Good work done ✅👏👏👏
I really need your help.
Pls am repairing a 10KVA ups with low battery alarm, even though the batteries are all replaced.
16 batteries in total, summing to 213v from multimeter check, but what appear on ups screen is 174v .
Kindly assist me , what could be the possible cause of the fault which affecting the voltage failure sensing.
Thank you 🙏
The screen of UPS may be wrong. Please check the output voltage.
Very good technics. Thank you
Super sir
If the reserve voltage 12v that we are giving to UPS circuit fir checking does not give 220v output what can be the issue ?
that means Battery is OK but fault in board component
Nice explanation
Super bro
Pranab jee..super good videos 🤝👏👏👏👏😎😘
I have issue with my UPS which it only gives 150v (low voltage) supposed to be it should release 220v. Note that this has new replaced battery. Any idea what needs to be done to get this fixed?
Please check your Transformer output. If the transformer is ok then check relays
Hi Sir,
I have vguard sesto 600 ups which supports 300 watt.
But when I connect led tv of 173 watt , ups gets shut down.
But when I give 50-60 watt load, it does not get shut down.
What can be the cause of shutdown ? Can you please reply?
Hi, nice video My ups keeps going on and off
Hi Bro, wanna ask how can i turn ups (without battery) work like avr system, cause I have 1 ups and battery faulty, but I no need to use battery now, so I think want to turn it as avr, but once I removed the battery the ups cannot on, even I plugged the 230V power.
Bhai light cut hote hi mera UPS instantly off hojata h 😢sala pc bhi roj bandd hojata h
Ap battery ka voltage check kijiye.
Can we repair the battery?
Yes, battery can be repaired by replacing the lead and acid. But you can not do it yourself. It is very much risky. It is better that you can give it to the battery dealer and buy a new one by adjusting some amount. Or you can sell the old battery directly to the dealer.
@@PranabsLab thank for your guidance...
hye bro,my ups battery prob low voltage,when i try put power same like u use,output voltage higher then 230,i check with multimeter,got voltage is 350v..what a problem..
Har agla banda engineer bana phir raha hai battery change karo aur ap sub bhi engineer ban jao lol
Hi, my ups turns on & works but the battery only last for 20min powering a low wattage device(modem). I assumed it was the batteries so removed them for replacement but on testing they were healthy. What else could be causing this
Check the wattage of your modem. I think it is not consuming low wattage.
My UPS has two batteries and one batteries voltage is low around 8v and another one is perfect around 12v what should I do
Change the 8V battery
@@PranabsLab ok
Hii
I have a 12V adaptor
But it's other specifications are not exactly as same as your water purifier's specs. Can you please tell me if I can use that ?
Please check the output current in your 12 V adaptor. If it is too much higher than you are using, then you should not use this, otherwise you can use.
@@PranabsLab
Yes I did everything as shown in your video and the UPS started up, but I don't have a Multimeter to check Output.
Pranab hi, kya aisa ho sakta hai ki battery sahi hai, output bhi sahi hai Lekin l mere power cable me hi problem ho ?
Ho sakta hai. Ap ekbar cable continuity test Kar lijiye. Agar cable Sahi ho, fir bhi output nhi aa rha ha, to apko circuit board check Karna padega.
@@PranabsLab Okk ji, jald hi kahi se multimeter me reading check karwata hu
Thank you so much !
Maine channel subscribe kar diya hai 😊👍🏻
Thanks 😊
My ups is not giving backup. Maximum 40 sec backup. But few days ago suddenly ups was given 30 min backup. This is happen only one time. Battery output voltage 24 volt. What is the fault?
How much old is your Battery?
@@PranabsLab 5 yrs
My APC UPS , which is 1 year 6 months old is giving internal error everytime I start it up.
What could be the reason and how to fix it ?
May be the problem in the PCB
Do you know how we can recharge the uninterrupted powersupply? Without opening it
Without opening, we can't recharge only the battery
My input show only 210v (household)
On giving supply by using 12v 2 A adapters usp givs only 169 v
Is my ups complain!
Tera English Tera pass he rak you tube par mat bata
You forget to show charging voltage
Dada amar ups a power cut hole monitor black screen hoye tarpor on hoy . Ups ta kharap holo naki???😢😢😢
Relay চেক করুন
Bro my ups works properly when there is no load connected to it, it beeps properly at regular intervals and all. But when i connect an ac load to its output it instantly shuts down, any reason as to why this happens.. please help
Please check the Battery of the UPS. May be after replacing the battery, your problem would be solved.
👍👍👍👍👍
~ so we need to buy a new BATTERY. How do we know the size?
From previous one, which was installed
I have power in all 3 outlets holes, the tester light up in all of them, what is the reason?
Check your PCB
@@PranabsLab how shoult i check it? It's from corsair cv 450, my pc isn't very power hungry
Whats the price of this battery
750-800 INR
আচ্ছা ইউপিএস কি 24 ঘণ্টা অন করে রাখতে হয়?
হ্যাঁ, আনিনন্টারাপ্টেড পাওয়ার সাপ্লাই পেতে গেলে ইউ পি এস চব্বিশ ঘণ্টাই অন করে রাখতে হবে
Dada, amar ups normally choley, kintu kokhono-kokhono cholte-choltey hotath battery mode a chola suru kore dei (mane current na thakley r ki jamon choley).. tumi ki bolte parbe erokom kano hoe? Amar ghorer voltage akdom thik achey.😅
Relay gulo separately check koro
Sir ji what is the reason ups in trouble battery disconnected
The battery got damaged.
I have purchased same ups today. But its not turning on. The power button automatic pushes out when I press it. So I booked return of the product.
@@beatfactoryindian2824 dead battery
Yeh, may be
Bro what is the price of battery
₹.700
Bro one problem supply 12v power but led bulb is blakin...😢😢 Please help.........a..
Check the voltage by using multimeter
Whenever power fluctuates or power goes off my pc restarts even if it is connected to ups.
What should i do ?? Please help
Please check circuitry of UPS. Fault may be in Relay section.
@@PranabsLab Ok 👍
How much is the UPS battery?
INR 850 in India
Why charging your battery with a new instead of charging
Inki English bolane ke tarike se pata chalta Hai Ki Bangali hoga
I am trying to charge a UPS from another UPS.
When I plug one UPS into the other one it is not charging the battery, however the AC power seams to go through the first one.
I have tried 3 UPS, none of them will charge the first UPS.
Why is this?
Try to charge the UPS by raw power. Usually UPS cannot charge the battery of another equal capacity UPS.
@@PranabsLab Hey friend, thanks for your answer.
Let me explain the situation more.
I am using this system in my car where I live right now.
So my power source is my 12 Volt battery in my car.
The first UPS is an APC 600 unit that is hooked up to my Car battery with wires.
The second UPS is a Cyber-Power 1500VA unit which has two batteries at 24 Volts.
So I can not charge the second UPS from my car, but I should be able to charge it from my APC 600, by simply plugging it into the 120 Volt outlet, right?
The problem is that the Cyber-Power UPS does not sense that I have plugged it into the APC 600. But when I plug it into the house outlet, everything works fine.
I don't understand why this is happening.
I have also tried to plug in a 3rd UPS and that does not sense either that it has been plugged in.
But if I plug in my stereo or laptop, for example, it works fine.
What could be the problem? Thanks!
The problem is that, your APC 600 is connected with 12V battery of your car and your Cyber Power is of 24V supply which is incompatible with the charging UPS. That's why your Cyber Power ups is not charging.
@@PranabsLab But I am trying to charge it from the 120 Volt outlet, why would that be incompatible, that is my question?
It's not only about Voltage but Current also responsible for charging. For your case I think current is insufficient.
Yah Banda pakka Bangali hoga
Tq Sir
ভাই, আমার UPS charging করার সময় Motherboard প্রচন্ড গরম হয়। কোনো পার্টস এ কি সমস্যা হয়েছে?
প্রথমে ভেবেছিলাম চার্জের সময় হয়তো ট্রান্সফরমার বা ব্যাটারি গরম হয়, কিন্তু ভালো করে খেয়াল করে দেখলাম motherboard গরম হচ্ছে। দুটি cooling fan লাগিয়েছি। কিন্তু পার্মানেন্ট solution চাচ্ছি।
UPS : 1200VA double battery.
Battery : 12v 9 Ah ( 2 battery)
IC এর Heat Sink গুলোতে ভালো করে thermal paste লাগিয়ে দেখুন। ওতেও না হলে একটু বড় সাইজের heat sink লাগান।
আগে এই সমস্যা ছিলোনা৷
হঠাৎ করেই এরকম সমস্যা৷
১ বছরের মতো ব্যবহার করেছিলাম তারপর ৩-৪ বছর আর ব্যবহার করা হয়নি৷ এখন নতুন ব্যাটারি লাগিয়ে ব্যবহার করছি।
শুধু চার্জ নেয়ার সময় গরম হয়, ব্যাকাপ দেয়ার সময় একটুও গরম হয়না
নতুন ব্যাটারির specification change করে দেননি তো? বেশি AH ক্যাপাসিটির লাগিয়েছেন কিনা দেখুন।
একটু বেশি লাগিয়েছি। 7.5 Ah এর যায়গায় 9 Ah.
Ampier একটু বেশি হলেতো এমন হবার কথানা।
ওটার জন্যেই বোর্ড হিট হচ্ছে। ইলেক্ট্রনিক্স এলিমেন্টস গুলো খুব সেনসিটিভ হয়। যে রেটিং এর ব্যাটারি ছিল ওরকমই লাগান। এরকম করে ব্যবহার করতে থাকলে, হঠাৎ সার্জ এলে আপনার ব্যাটারি আর বোর্ড দুটোই যাবে।
Emerson UPS - PSA600-SOHO wala he sirf 10 mint ka time deta he magar phir charge nahi hota he bar bar on off hota he
Aap battery check kijiye. 3/4 saal se chal rha h to change karne ka time aagaya h.
Earthing in battery problem in ups how to solve
Please check Earth continuity in your house
@@PranabsLab in house no earthing wiring but in starting ups don't do shock while touching battery terminals but now I get a current shock while the touching battery terminals why it's happening??
@gyaneshwaram99 please complete your earthing system in your house before connecting your UPS
@gyaneshwaram99 Till then don't connect your UPS.
Aaj hi kharida hu or aisa ho raha hai 😢😢
Ups - APC 600
Whatta english😂😂
বিশ্বাস করুন আপনার চ্যানেলে ইংলিশ শিখতেই গিয়েছিলাম, এই টপিকের উপর কোনো ভিডিও দেখতে পেলাম না তাই বেল আইকনে "জোড়ে থাপ্পড়" মারতে পারলাম না subscribe তো দূরের কথা। 🙂
@@PranabsLab english man bangla te likheche..😜😜😜 ato rag valo na mona.. Banglai valo to banglai video bana.. Besi lok dekhbe.. Bojhate o parbi valo kore...
আমার ইংলিশ তো আপনি বুঝবেন না। তাই অনুবাদ করে দিলাম।
অপরিচিত কাউকে আপনি সম্বোধন করতে হয়। বাড়িতে শেখায়নি বোধ হয়।
@@bengaliaholic455 whole purpose of a language is to convey ideas/communicate . I think everybody can easily understand his English.
Bro's English is more than good enough to be understood by any other reasonably intelligent English speaker. We should be thankful for him sharing his knowledge.
I'm curious, how does the UPS actually work?
Wouldn't it damage your 12v adapter, when you also connect the 220v AC?
In my understanding, when you connect to a 220v power outlet, then it will charge the battery which in this case, your ADAPTER. Wouldn't it damage the adapter?
he used a heavy duty 12v adapter which is enough for testing the circuit..should not use it for more than 1 minute.
What is the price of battery?
₹750 INR or $10.2 USD
@@PranabsLab online এ এই battery টা পাওয়া যাবে?? যদি পাওয়া যায় তাহলে please link টা share করুন 🙏🙏
😂😂😂😂😂😂😂😂😂😂
Fucas😂
plz reply
Please put your query
😂😂..your English...pls speak in Hindi language
Please subscribe our Hindi channel Pranab's Lab हिंदी
Sidhe sidhe bol n battery change Krna h
Battery kiyon change karna hai, battery defect hai vi ya nhi, ye vi to batana hai na vai. Samjha kar bat ko
we need to first check o/p voltage of atleast 220AC by connecting 12v adapter instead of battery. This shows that circuit is working fine.
Video is good and I appreciate his efforts in explaining everything.