  • #Ashida make #relay in control panel
    The #ADR141C is a 3 OC and 1 EF Medium Voltage Protection relay with Instantaneous high set and programmable output design in very compact cabinet. ... Non Communicable Numerical Over current / Earth fault Medium Voltage Protection Relay.
    ADR141C is second generation Numerical 3OC
    1EF Over Current Relay. It consist all the
    necessary protection and monitoring functions
    required for Normal feeder. It consist of
    1. High Speed Digital DSP Controller
    2. Analog Measuring Module
    3. Power supply Module
    4. Digital Input output module.
    The High speed Digital Signal Controller
    continuously monitors phase, E/F current along
    with different optical isolated status
    connections. The high-speed micro-controller
    samples these current signals through a A/D
    converter. The Digital Signal performs
    powerful Numerical Algorithms to find out
    RMS of fundamental & harmonic contents of
    the current then this value is used for protection
    and metering function. All measurement is
    tuned to fundamental frequency i.e. 50Hz, thus
    relay remain stable during distorted waveform
    generated electronics loco-motive. All these
    measure values are then used for different
    protection function such as IDMT/DMT Over
    current protection, Instantaneous Over current
    protection, Earth Fault protection, etc. These
    measured values are also displayed on large
    16 x 2 LCD display for metering purpose. The
    DSC also monitors different digital input
    through optical isolator and perform some
    monitoring function such trip circuit supervision,
    and control potential free contact for control CB
    and generate ALARM and Tele-signalling.The power supply module is basically DC - DC
    converted designed using modern PWM based
    Switching mode technique to convert station
    battery supply to the 12V and 24Vdc low
    voltage supply for relay electronics and control
    circuit. It also provides necessary isolation from
    station battery. The power supply module is
    design using very advance PWM controller
    which allow very wide input supply variation i.e.
    24V to 230VAC/DC (±20%) covering 24Vdc,
    30Vdc, and 110V dc and 220Vdc station battery
    requirement.
    The relay is having total 4 nos of high intensity
    dual LED for easy identification of type of fault
    for easy user interface. All LEDs and control
    output R1 to R4 are fully programmable via
    keypad interface.

ความคิดเห็น • 29

  • @amalraj9733
    @amalraj9733 6 หลายเดือนก่อน +1

    Thanks🙏 brother

  • @parmodyadav9966
    @parmodyadav9966 2 หลายเดือนก่อน

    Sir RELAY me trip circuits Yes krte he power on ki LED red colour ki ho jati hai.time and date sahi set h.vase relay kabhi self operate Hoti hai or kabhi nahi.incomeer vcb trip karwati hai

  • @michaelcheruiyot8855
    @michaelcheruiyot8855 ปีที่แล้ว +1

    Is there English version explanation ?

  • @michaelcheruiyot8855
    @michaelcheruiyot8855 ปีที่แล้ว +1

    What is I>>p BR error and how to make the suitable setting for that. Kindly assist

  • @amalraj9733
    @amalraj9733 6 หลายเดือนก่อน

    Brother... While I am testing EARTH FAULT INDICATOR test.. That time I inject over current relay trip or not???

  • @ravindrakumarrahangdale5963
    @ravindrakumarrahangdale5963 2 ปีที่แล้ว +1

    How to Reset this relay.. Tripping condition

    • @TeamElectricalEngineers
      @TeamElectricalEngineers  2 ปีที่แล้ว

      Long press the reset button

    • @ALLINONE-bj6ug
      @ALLINONE-bj6ug ปีที่แล้ว

      @@TeamElectricalEngineers long press to HWreset done eventhough not gone shows only trip fault

  • @rajunvrajunv5859
    @rajunvrajunv5859 2 ปีที่แล้ว +1

    86 trip iundhi problem record ela chek chesedhi ela remove chestharuu

    • @TeamElectricalEngineers
      @TeamElectricalEngineers  2 ปีที่แล้ว

      Video complete ga chudandi... Information undi dantlo ela chudalo...

  • @venkatdurga9311
    @venkatdurga9311 4 ปีที่แล้ว +1

    👍

  • @kumarreddy2725
    @kumarreddy2725 4 ปีที่แล้ว +1

    Nyc🔥🔥

  • @Mallikarjun014
    @Mallikarjun014 3 ปีที่แล้ว +1

    Anna thanks

  • @konchokishey4929
    @konchokishey4929 ปีที่แล้ว +2

    Please explain in English version.

  • @Mallikarjun014
    @Mallikarjun014 3 ปีที่แล้ว +1

    Fault ela check cheyali anna

  • @RaviTeja-wj3fr
    @RaviTeja-wj3fr 4 ปีที่แล้ว +1

    Hi brother

  • @yogeshmakde2657
    @yogeshmakde2657 ปีที่แล้ว +1

    Bhai hindi me daliye na vedio

  • @Gautamkumar-jd6bt
    @Gautamkumar-jd6bt 3 ปีที่แล้ว

    BF Enabel &BF Delay meaning

  • @RaviTeja-wj3fr
    @RaviTeja-wj3fr 4 ปีที่แล้ว +1

    Brother Schneider electric relay show him Netural current brother R Y B okay show neutral current

  • @clivemashimi6926
    @clivemashimi6926 9 หลายเดือนก่อน

    English please