R32 Como recolher esse fluido na condensadora

แชร์
ฝัง
  • เผยแพร่เมื่อ 27 ก.ค. 2024
  • cursoinvertersemmedo.com.br/
    Ciclos de Manutenção em Split
    ciclosdamanutencao.com.br/
    Nosso Link Tree
    linktr.ee/admin

ความคิดเห็น • 313

  • @marciocastro4388
    @marciocastro4388 4 วันที่ผ่านมา +2

    muito bom esse video bastante conteúdo

    •  4 วันที่ผ่านมา

      👍

  • @vagnergarcia7360
    @vagnergarcia7360 5 วันที่ผ่านมา +1

    Ganhou mais um inscrito. Que aula top.

    •  4 วันที่ผ่านมา

      Bons estudos!

  • @juracifreitas8360
    @juracifreitas8360 4 หลายเดือนก่อน +5

    Valeu Ciro Gomes!
    Repare bem, como vale a pena assistir vídeo de profissionais dedicado como voce companheiro.

    •  4 หลายเดือนก่อน +1

      Valeu obrigado

  • @ronienascimentosep4259
    @ronienascimentosep4259 2 หลายเดือนก่อน +1

    Parabéns. Isso não foi uma explicação, foi uma aula. Quem conhece, conhece.

    •  2 หลายเดือนก่อน

      Muito obrigado

  • @marciocastro4388
    @marciocastro4388 4 วันที่ผ่านมา +2

    parabéns

    •  4 วันที่ผ่านมา

      👍

  • @davibueno5411
    @davibueno5411 10 หลายเดือนก่อน +2

    Muito bom obrigado por compartilhar seu conhecimento.

  • @emillyfernandes3835
    @emillyfernandes3835 ปีที่แล้ว +1

    Show de conhecimento. Meu amigo parabéns ótima expressão 👏

  • @Roberto2009250
    @Roberto2009250 ปีที่แล้ว +2

    Achei legal mesmo inteligente funcional eficiente técnico preciso parabéns.

  • @AlexandreAzevedo-pw8lg
    @AlexandreAzevedo-pw8lg ปีที่แล้ว

    Boa noite!
    Parabéns pela explicação, didática bem interessante,isso aí

  • @gualterfreitas1288
    @gualterfreitas1288 ปีที่แล้ว +7

    Meu amigo vc agrega muito conhecimento nos nossos trabalhos muito obrigado por compartilhar seus conhecimentos.

  •  2 หลายเดือนก่อน +1

    Parabéns Julio! é isso ai ........ por aqui sempre a disposição

  • @joselioamaral826
    @joselioamaral826 ปีที่แล้ว

    Ótima explicação, top

  • @AlexandreFernandesDesousa
    @AlexandreFernandesDesousa หลายเดือนก่อน +1

    Como é bom obter conhecimentos com quem tem propriedades no assusto.
    Parabens... E ainda mais sucesso!!!

    •  หลายเดือนก่อน

      Muito obrigado

  • @BraSClima
    @BraSClima ปีที่แล้ว +3

    Um baita joinha pra você meu amigo, belo vídeo.

    •  ปีที่แล้ว

      Obrigado pelo like

  • @jeffersonoliveirasilva8023
    @jeffersonoliveirasilva8023 5 หลายเดือนก่อน +7

    Pra mim está sendo muito gratificante suas explicação sobre o recolhimento do gás R32 pra condessadora. Depois desse acidente trágico que ocorreu essa semana. Muito obrigado pela explicação.

    •  5 หลายเดือนก่อน +1

      Obrigado! Seja bem vindo

    • @jeffersonoliveirasilva8023
      @jeffersonoliveirasilva8023 5 หลายเดือนก่อน

      Obrigado eu 🤝

  • @iranrobertomacedodasilva4559
    @iranrobertomacedodasilva4559 5 หลายเดือนก่อน +1

    Falou com propriedade. Está corretíssimo.

    •  5 หลายเดือนก่อน

      Obrigado

  • @johnrivas1949
    @johnrivas1949 11 หลายเดือนก่อน

    Show de Bola

  • @psrrefrigeracao
    @psrrefrigeracao 6 หลายเดือนก่อน +1

    Parabéns mano

  • @prontto7974
    @prontto7974 5 หลายเดือนก่อน +1

    parabéns por passar teu conhecimento

    •  5 หลายเดือนก่อน

      Eu que agradeço

  • @dirleiduarte7002
    @dirleiduarte7002 6 หลายเดือนก่อน +1

    parabens pelo seu profissionalismo!!

    •  6 หลายเดือนก่อน

      Muito obrigado

  • @gabryelhenryquesouzadasilv6338
    @gabryelhenryquesouzadasilv6338 5 หลายเดือนก่อน +1

    Achei massa demais sua explicação!

    •  5 หลายเดือนก่อน

      Fico feliz

  • @pablocarvalho3458
    @pablocarvalho3458 5 หลายเดือนก่อน +1

    Sua explicação é muito importante

    •  5 หลายเดือนก่อน

      Obrigado ☺️

  • @alissonnegreiros9492
    @alissonnegreiros9492 หลายเดือนก่อน +1

    Parabéns pelo dicas muito bom

    •  หลายเดือนก่อน

      Espero ter ajudado

  • @serginhocolares3232
    @serginhocolares3232 5 หลายเดือนก่อน +1

    Muito bom minha altarquia explicação nota 10

    •  5 หลายเดือนก่อน

      Ok

  • @paulocesarlima8338
    @paulocesarlima8338 ปีที่แล้ว +1

    ótimo vídeo Fabrício

    •  ปีที่แล้ว

      Obrigado

  • @jrsouza19
    @jrsouza19 ปีที่แล้ว

    Muito bem!!!👋👋👋

  • @wilsonfreire8537
    @wilsonfreire8537 ปีที่แล้ว +1

    Boa tarde professor gostei muito da explicação muito obg mesmo

    •  ปีที่แล้ว

      Obrigado pelo seu comentário

  • @glennguzmann2274
    @glennguzmann2274 2 หลายเดือนก่อน +2

    Boa noite amigo , para sua maior segurança , quando você recolher qualquer gas , em cilindros usar um balde de gelo ou colocar o cilintro em um frezer antes de usar , para recolher o gas , desta forma a temperatura de qualquer gas teria uma entropia na estrutura molecular do gas .

    •  2 หลายเดือนก่อน

      Ciente disso! Obrigado.

  • @fabiogabrielliantonio7437
    @fabiogabrielliantonio7437 8 หลายเดือนก่อน +1

    Ótimo conteúdo!!

    •  8 หลายเดือนก่อน

      Obrigado 😃

  • @franciscocaninde638
    @franciscocaninde638 ปีที่แล้ว +1

    Show 😊

  • @erivancomapemotaery6556
    @erivancomapemotaery6556 ปีที่แล้ว +6

    Parabéns meu amigo,uma ótima explicação sobre esse procedimento,que Deus lhe abençoe grandemente.

    •  ปีที่แล้ว +1

      Obrigado amigo! Estamos sempre a disposição. Aquele abraço...

  • @augustocesar4127
    @augustocesar4127 5 หลายเดือนก่อน +6

    O risco de explosão é verdade

    •  5 หลายเดือนก่อน

      Negativo

  • @corecha18
    @corecha18 5 หลายเดือนก่อน +1

    Obg pela explicação amigo

    •  5 หลายเดือนก่อน

      Disponha!

  • @user-po7bn1mi9b
    @user-po7bn1mi9b 9 หลายเดือนก่อน +2

    Boa tarde amigo excelente aula, faço recolhimento de fluido referentes de todos os aparelho de ar condicionado dos meus clientes pois só trabalhos com manutenção geral da máquinas tanto da condensadoura como da evaporadora desmontando por completo, e graças a Deus nunca tive nenhum problema, hoje caiu por terra tudo que já imaginava a respeito de muitas falácias e mitos. Parabéns amigo um forte abraço fica com Deus.

  • @user-wk7oi9xg7y
    @user-wk7oi9xg7y 9 หลายเดือนก่อน +1

    top gostei

  • @devanirsalvador1912
    @devanirsalvador1912 9 หลายเดือนก่อน

    Parabéns amigo obrigado por passar o seus conhecimentos pra nós iniciante

    •  9 หลายเดือนก่อน

      Eu que agradeço

  • @SetecClimatizacao
    @SetecClimatizacao ปีที่แล้ว +1

    Ótima explicação professor, como sempre 👏🏻👏🏻👏🏻

    •  ปีที่แล้ว +1

      Obrigado sempre

  • @edsartesanatopvc7467
    @edsartesanatopvc7467 2 หลายเดือนก่อน +1

    boa noite amigo sou de olinda pernambuco . Estou começando no ramo ou seja estou cursando climatização e refrigeração. Sua explicação tirou minha duvida em relação ao armazenamento do gás R32 na condensadora. Muitos videos na internet complicam um pouco a explicação . Você explicou corretamente. Parabéns !

    •  2 หลายเดือนก่อน

      Fico feliz 🙂

  • @valmir.refri.comercial
    @valmir.refri.comercial 3 หลายเดือนก่อน +1

    Parabéns obrigado pelos esclarecimentos, sou o Valmir de Maracanaú Ceará

    •  3 หลายเดือนก่อน

      Eu que agradeço

  • @claudiopedrorodrigues6863
    @claudiopedrorodrigues6863 4 หลายเดือนก่อน +1

    Muito obrigado pela informação está tirando muitas dúvidas sobre o gás r32

    •  4 หลายเดือนก่อน

      Disponha!

  • @tuias4154
    @tuias4154 2 หลายเดือนก่อน +1

    Parabéns pela explicação muito foda

    •  2 หลายเดือนก่อน

      👍

  • @euripedescaetano9839
    @euripedescaetano9839 9 หลายเดือนก่อน +2

    Obrigado pela experiência nesse vídeo, foi ótima

  • @wendersonrefrigeracao
    @wendersonrefrigeracao ปีที่แล้ว +1

    Gosto Muito do seu trabalho sempre trazendo trazendo novidades agradeço.

  • @user-kv1qq3di6v
    @user-kv1qq3di6v 5 หลายเดือนก่อน +1

    Show sua explicação, eu sempre recolhi gás pra condensadora também muito bom seu trabalho abraços.

    •  5 หลายเดือนก่อน

      Obrigado 👍

  • @renildosantos2906
    @renildosantos2906 2 หลายเดือนก่อน +1

    Boa tarde.
    Sua explicação está corretíssima. Agora vale lembrar que você recolheu o R32 em uma maquina que você mesmo instalou e fez todos procedimentos necessários como o vácuo. Eu particularmente não recomendo recolhimento de fluido refrigerante R410a e R32 para a condensadora se você não souber como foi feita a instalação, acho que é um risco desnecessário. Estou apenas dando minha opinião.
    Mais como disse no inicio boa explicação.

    •  2 หลายเดือนก่อน

      Boa observação

  • @evertonavelino7213
    @evertonavelino7213 18 วันที่ผ่านมา +1

    Bom dia, muito bom as informações passada no vídeo.
    Uma dúvida, caso o último técnico na instalação do equipamento, não vez o procedimento de vácuo, podendo ter entrado umidade no sistema, há perigo no recolhimento do fluido na condensadora?

    •  18 วันที่ผ่านมา +1

      Sem problemas

  • @rafaelmoreira201
    @rafaelmoreira201 5 หลายเดือนก่อน +2

    Vou falar para todos vcs !
    Eu moro no litoral do Paraná aqui os compressores costumam furar de ferrugem se vc não verificar a máquina antes de ligar e ela estiver com vazamento no compressor qualquer faísca ou eletricidade estática ou uma máquina marcando massa no compressor e muito perigoso..
    A vida útil antes de apodrecer é uns 3 a 4 anos

    •  5 หลายเดือนก่อน

      Ok 👍

  • @furtacor3684
    @furtacor3684 2 หลายเดือนก่อน +1

    Top demais, você fez a manobra de recolhimento calmamente passo a passo.... Você poderia ter deixado o equipamento ligado após o recolhimento, não iria explodir nada. Só iria perder o compressor se n tiver algum dispositivo de segurança...

    •  2 หลายเดือนก่อน +1

      Ele ficou ligado

    • @jonesgomes5355
      @jonesgomes5355 2 หลายเดือนก่อน

      Eu vi ligado

  • @amarildorodrigues2642
    @amarildorodrigues2642 ปีที่แล้ว +1

    Top...

  • @AlanBenevidesAlmeida
    @AlanBenevidesAlmeida หลายเดือนก่อน +1

    Top.....eu tava com dúvida... vídeo top...podemos recolher o gás r32 pra condensadora então, tranquilo e seguro.

    •  หลายเดือนก่อน

      Dá sim

  • @demetriosilva9401
    @demetriosilva9401 5 หลายเดือนก่อน +1

    Também ja recolhi e nada de problema, foi até num arcondicionado elgin daquele modelo redondo barril modelo novo que ja ta no mercado foi um sucesso o recolhimento

    •  5 หลายเดือนก่อน

      Maravilha 🙌

  • @joseeudivanlima5912
    @joseeudivanlima5912 5 หลายเดือนก่อน +1

    Sua aula sobre o gás r32 foi exatamente

    •  5 หลายเดือนก่อน

      Ok

  • @franciscofranciscoaragaode4383
    @franciscofranciscoaragaode4383 4 หลายเดือนก่อน +1

    Ganhou inscrito.

    •  4 หลายเดือนก่อน

      Agradeço muito

  • @nelingtonrefrigeracao1765
    @nelingtonrefrigeracao1765 5 หลายเดือนก่อน +1

    Parabéns gostei do vídeo
    Realmente não vejo problema em recolher o gás

    •  5 หลายเดือนก่อน

      👍 obrigado seja bem-vindo

  • @alminorizutto4684
    @alminorizutto4684 4 หลายเดือนก่อน +1

    Almino Rizutto de Manaus muito esclarecedor
    Aqui aínda é um tabu o r 32

    •  4 หลายเดือนก่อน

      Logo vai deixar de ser um tabu! Confia que vai dar certo

  • @juliongolangola6826
    @juliongolangola6826 6 หลายเดือนก่อน +1

    Muito obrigado pelo conhecimento passado.

    •  6 หลายเดือนก่อน

      Disponha!

  • @speedtouchbr
    @speedtouchbr 9 หลายเดือนก่อน

    Gostei do aterramento com o vergalhão enfincado no chão

  • @juliocostta697
    @juliocostta697 2 หลายเดือนก่อน

    Parabéns pela aula, obrigado por tirar minhas dúvidas sobre recolher o R32, embora eu já havia recolhido de 2 máquinas Agrato 18000 que retirei para desocupar um imóvel e fiz o procedimento normal com a máquina ligada, fechei a expansão e aguardei entra em vácuo, fechei descarga e retirei a máquina, reinstalei 1 semana depois e procedimento normal.

    •  2 หลายเดือนก่อน

      Que bom que ajudou

  • @alexanderguitar4217
    @alexanderguitar4217 หลายเดือนก่อน +1

    Muita boa a explicação, mas na maioria das máquinas não tem como verificar a pressão de alta no preocesso de recolhimento.

    •  หลายเดือนก่อน

      👍

  • @moabdebora2730
    @moabdebora2730 10 หลายเดือนก่อน +1

    Muito boa explicação. Como foi adicionado estás válvulas de serviços para colocar os manômetros para verificar as pressões?

  • @andrejose5025
    @andrejose5025 9 หลายเดือนก่อน +4

    O perigo de recolher o gás é tão somente a falta do vácuo,por conta da umidade (oxigênio)

  • @contapessoal4398
    @contapessoal4398 5 หลายเดือนก่อน +2

    Todo mundo dizendo que não explide até acontecer a tragédia que ocorreu ontem. Triste. Siga orientação do fabricante. Alguns fabricantes proibem o recolhimento na condensadora

    •  5 หลายเดือนก่อน

      Ok

  • @hnclimatizacaofelipecostan9473
    @hnclimatizacaofelipecostan9473 4 หลายเดือนก่อน +1

    Fabrício por gentileza poderia fazer um conteúdo recolhendo fluido refrigerante R32 com 15 metros de linha, creio que assim atenderia muitas dúvidas em especial a minha tbm.

    •  4 หลายเดือนก่อน +1

      Posso sim 👍

  • @Oprninja
    @Oprninja ปีที่แล้ว

    Meu amigo ótimo vídeo !! mais no seu caso a condensadora é na sombra, si o sol estivesse pegando em cima da condensadora, co. U.a temperatura de uns 45 graus aqui do rio de Janeiro, tbm não teria problema ??

  • @lucassilvadossantos7317
    @lucassilvadossantos7317 2 หลายเดือนก่อน

    eu fiz recolhimento numa linha con excedente..de 10 mts e não tive nenhum problema não

    •  2 หลายเดือนก่อน

      Maravilha

  • @claudiobrito7164
    @claudiobrito7164 8 หลายเดือนก่อน +1

    Eu estava com a máquina funcionando

  • @lucasbarbosa4280
    @lucasbarbosa4280 23 วันที่ผ่านมา +1

    Tem alguns técnicos que não costuma fazer o vácuo, nesse caso a perigo em recolher o fluido 32 ?...

    •  23 วันที่ผ่านมา

      Nenhum

  • @josewillames1760
    @josewillames1760 2 หลายเดือนก่อน +1

    Só uma dúvida, vc diz para recolher,já o manua de instalação de algumas fabricantes diz pra não recolher,inclusive já instalei dessa marca e falava o mesmo.

    •  2 หลายเดือนก่อน

      👍

  • @williamtecnicoemrefrigerac6322
    @williamtecnicoemrefrigerac6322 11 หลายเดือนก่อน

    Boa tarde no caso esse gas sendo inflamável muda alguma coisa?

  • @fabricio_plaster
    @fabricio_plaster 5 หลายเดือนก่อน +1

    Muita gente falando mal desse r32 devido o acidente, sabe-se lá o que realmente provocou a explosao,mas certamente nao foi o r32 sozinho. Um grande risco que vejo em explosao de compressor seria acoplar o manifold na baixa no procedimento derecolher o gas e a mangueira ter algum problema de trincado ou vedaçao e deixar sugar ar atmosferico junto com o gas que esta sendo recolhido, aí temos uma mistura explosiva, sem contar que acredito que a pressao na alta vai subir a ponto de romper o casco pois agora tem r32+ar atmosferico dentro da maquina

    •  5 หลายเดือนก่อน

      Perfeito 👍

  • @marcelojose8755
    @marcelojose8755 5 หลายเดือนก่อน +1

    💯

  • @Progreenroleta
    @Progreenroleta 5 หลายเดือนก่อน +1

    Top mais ainda trabalho com medo desse gas, a pouco tempo morreu um técnico em Maceió a condensadora explodiu

    •  5 หลายเดือนก่อน

      Entendo! Mas fica tranquilo! Faça os procedimentos que não terá problema

  • @otaviosombra4954
    @otaviosombra4954 11 หลายเดือนก่อน

    Boa noite meu amigo, parabéns pelo video,mas se vc fechar a valvula de alta,na sua piteira de alta que vc soldou vc tera a pressão de alta da válvula em diante,sendo assim vera tera uma pressao de alta dentro do condensador do compressor em diante ate a válvula de alta que esta fechada na qual vc não tera como medir,se vc fizer um video medindo essa pressão seria top,mas essa pressa na hora do recolhimento e muito superior,as Electrolux inverter bao suportam recolhimento,a ipm dela nao suporta essa subida de corrente se vc demorar muito o prejuízo e certo,nao estou lhe criticando mas teocando ideia somos parceiros e cooperadores amém.

  • @fabricioLemes-b5o
    @fabricioLemes-b5o 13 วันที่ผ่านมา +1

    Ola e se tiver adicionado mas fluido devido a tubulação grande pode fazer o recolhimento, ou tem que soltar um pouco de gás?

    •  13 วันที่ผ่านมา

      Pode recolher

  • @clearcondicionado
    @clearcondicionado 9 หลายเดือนก่อน

    Só completando...
    A queda de pressão de alta cai, devido a mudança do estado do fluido, causado pelo motor ventilador.
    Forte abraço tmj..

    •  9 หลายเดือนก่อน +1

      Obrigado pelas dicas

    • @clearcondicionado
      @clearcondicionado 8 หลายเดือนก่อน

      Juntos somos mais fortes #refrigerista

  • @moabdebora2730
    @moabdebora2730 10 หลายเดือนก่อน

    Fiquei na dúvida por eu só presenciei uma válvula de serviços nós ar-condicionado que fiz manutenção.

  • @moisessouzamaciel7157
    @moisessouzamaciel7157 5 หลายเดือนก่อน +1

    Eu tenho um ar split q tem esse gás e eu mesmo fiz a instalação...sou amador e o técnico d falou q não podia recolher esse gás, eu eu teria q perder todo gás em caso de manutenção geral ae vendo esse vídeo vi q ele qer aplicar em mim mas depois dessa explicação ele não vai mais ....

    •  5 หลายเดือนก่อน

      Ok 👍

  • @user-mo1uu4jd8t
    @user-mo1uu4jd8t 3 หลายเดือนก่อน +1

    Vi caso que o compressor explodiu aqui em Maceió

    •  3 หลายเดือนก่อน

      Isso é uma outra situação

  • @NeySilva-rq7kg
    @NeySilva-rq7kg 4 หลายเดือนก่อน +1

    Obgd amig

    •  4 หลายเดือนก่อน

      Eu que agradeço

  • @Ancledson.lima123
    @Ancledson.lima123 2 หลายเดือนก่อน +1

    Acredito que a condensadora de alumínio influencie em alguns casos de acidentes de explosão

    •  2 หลายเดือนก่อน

      👍

  • @NeySilva-rq7kg
    @NeySilva-rq7kg 4 หลายเดือนก่อน +1

    Eu ja instalei umas 10 máquinas com gas r32

    •  4 หลายเดือนก่อน +1

      Maravilha 👌

  • @otaviosabad6961
    @otaviosabad6961 5 หลายเดือนก่อน +1

    Muito bom já estava ficando com medo muito video falando que explode 🙄🙄

    •  5 หลายเดือนก่อน

      Pois é

  • @le_941
    @le_941 4 หลายเดือนก่อน +1

    Excelente video! Seria entao o problema de explosão que algumas máquinas com R32 acontecendo devido algum erro de procedimento? Ex: linhas longas com adição de mais gás (mais do wue vem na máquina originalmente) e a explosão se deu pelo excesso de gas/líquido no condensador?

    •  4 หลายเดือนก่อน

      Não não! Tanto falta de gás quanto excesso não causaria explosão

  • @canallifeswap8070
    @canallifeswap8070 2 หลายเดือนก่อน +1

    Bom dia Eu instalei uma LG inverter com R32.
    Ela veio com R32 para 7 metros, mas a minha linha é de 15 metros, que é o máximo de linha que ela suporta, e tive que acrescentar 20 gramas por metro a mais aos sete metros de linha a mais.
    Somando 140 gramas a mais.
    A pergunta é, posso recolher todo esse gás refrigerante para dentro acrescentado na máquina a mais. José Pita . Muito obrigado.

    •  2 หลายเดือนก่อน +1

      Sim é possível

    • @canallifeswap8070
      @canallifeswap8070 2 หลายเดือนก่อน

      Muito obrigado Deus abençoe.

  • @carloscarvalho3645
    @carloscarvalho3645 3 หลายเดือนก่อน +1

    Eu mesmo não recolho prefiro fechar as duas linhas da condensadora baixa alta e depois repõe por segurança

    •  3 หลายเดือนก่อน

      Ok

  • @MarciodaMT
    @MarciodaMT 5 หลายเดือนก่อน +2

    Boa noite, Fabrício!
    Amigo, tenho uma dúvida; numa tubulação onde funcionava com r22, posso instalar uma máquina com r32?

    •  5 หลายเดือนก่อน +1

      Sim! Faça a limpeza da linha com produto específico

  • @waltersoares6108
    @waltersoares6108 ปีที่แล้ว +2

    Massa o conteúdo! Se a linha tiver 15 metros, mesmo assim ainda podemos recolher pra dentro da máquina? Tanto o R32 quanto o R410a?

    • @PatrickRodrigues-xs3vg
      @PatrickRodrigues-xs3vg 7 หลายเดือนก่อน

      Opa amigo, não é recomendável, pois provavelmente já foi colocado algumas gramas a mais de fluido, logo ele sobrecarrega o compressor

  • @joelmota2839
    @joelmota2839 2 หลายเดือนก่อน +1

    Boa tarde !
    Estou precisando de uma ajuda, instalei uma Elgin 12000 BTUs e com uma semana.wla começou a condensar o evaporadora aponto de molhar o ambiente o que pode ser ?
    Já fiz uma nova recarga de fluido e continua 😢

    •  2 หลายเดือนก่อน

      Aconselho a chamar um técnico autorizado.

  • @tellesperes496
    @tellesperes496 12 วันที่ผ่านมา +1

    Mas porque tem algumas marcas de ar condicionado com R32 que, tem uma etiqueta no condensador dizendo que não pode recolher o gás?

    •  11 วันที่ผ่านมา

      Por uma sugestão do fabricante! Provavelmente ele não confia na mão de obra

    • @matheusmelo537
      @matheusmelo537 8 วันที่ผ่านมา

      Isso realmente existiu por um tempo mas hoje os fabricantes mudaram os dizeres nas etiquetas onde agora falam para não recolher caso haja suspeita de vazamento

  • @4Rmarketing_digital
    @4Rmarketing_digital 4 หลายเดือนก่อน +1

    Fala Fabricio, video muito bom! O problema é não saber quem instalou a maquina...dizem que se o vacuo não foi feito pode ocorrer o efeito diesel, ou seja, o contato do oleo do motor com o R 32 e o oxigenio presente no sistema devido a falta do vacuo...procede essa informação? Outra informação que ja escutei por ai é que não posso recolher com a condensadora se foi colocado mais gas no sistema, por exemplo em linhas onde a distancia entre evaporadora e condensadora é grande...o quanto a mais de gas a condensadora suporta? Valeu

    •  4 หลายเดือนก่อน

      Dá para recolher sim 👍! Tem muito boato no mercado

  • @adailtojesus5904
    @adailtojesus5904 หลายเดือนก่อน

    O gás refrigerante que veio de fabrica... Que se encontra no compressor... Esse pode... Mas se vc tem que aumentar o tubo... E tem que acresentar +... Fluido... Aí realmente vc não podera recolher para a condesadora... Vai twr qual é a pressão de trabalho da maquina dispensar o que vc colocou e recolher outro... Vale lembrar que esse gás e alta mente inflamáveis... Fiquem ligados...👊👊👊

    •  หลายเดือนก่อน

      INFORMAÇÃO ERRADA! Pode recolher sim e a unidade condensadora tem espaço para isso. Tem vídeo aqui no canal sobre isso.

  • @moisessouzamaciel7157
    @moisessouzamaciel7157 5 หลายเดือนก่อน +2

    Amigo e pra completar esse gás em caso de fuga como proceder ?

    •  5 หลายเดือนก่อน

      Em caso de vazamento, NÃO

    • @moisessouzamaciel7157
      @moisessouzamaciel7157 5 หลายเดือนก่อน

      @ pq não posso completar ?

  • @housesandarkusnefastus-riq1176
    @housesandarkusnefastus-riq1176 2 หลายเดือนก่อน +1

    Boa tarde. Fui comprar a recolhedora e o vendedor falou que não aconselha recolher o R32 nela, uma máquina Suriah de 1/2 Hp... O que o Senhor me diz?

    •  2 หลายเดือนก่อน +1

      Pode usar sim com R32 sem problema

  • @wearver
    @wearver 5 หลายเดือนก่อน +1

    Sou apenas curioso em refrigeração, sempre que algum equipamento dá defeito, eu procuro estudar como funciona para não ser enganado, é o que fiz com refrigeração também. Eu imaginei que se for recolher o gás tinha perigo de explodir alguma linha, mas vendo o vídeo me esclareceu uma coisa, o compressor tem apenas "força" de deixar essa pressão apenas, então não tem perigo, a menos que tenha algum problema no sistema. Agora, uma dúvida, independente do gás, ele contém óleo, se tiver algum vazamento ou instalação errada, pode ocorrer o fenômeno Diesel ? Que seria a compressão de ar junto com óleo até atingir certa temperatura? Falo isso porque vi um experimento que se comprimir o ar ele aquece muito podendo ocasionar explosão ?

    •  5 หลายเดือนก่อน

      Isso mesmo!

  • @raimundogomes3358
    @raimundogomes3358 9 หลายเดือนก่อน +1

    Boa tarde me tire uma dúvida me disseram que no modelo novos da Eletrolux barril inverter não se pode recolhe este gás pois queima o rpm dela na placa devido a pressão subi nela posso ou não recolher

    •  9 หลายเดือนก่อน

      Pode sim sem problemas

  • @user-fs1lh8ub3l
    @user-fs1lh8ub3l 5 หลายเดือนก่อน +1

    LegaLho

    •  5 หลายเดือนก่อน

      Ok

  • @erickcaetano9138
    @erickcaetano9138 5 หลายเดือนก่อน +1

    Não vi ninguém falando de gás adicional que se é colocado no equipamento quando a carga excede a quantidade do fabricante da tubulação padrão 😮 creio que seja perigoso eu não faço, executo recolhimento somente carga padrão 😊

    •  5 หลายเดือนก่อน

      Ok

  • @marcoscorrea5589
    @marcoscorrea5589 4 หลายเดือนก่อน +1

    Professor, na sua opinião, o porque dessas explosões?

    •  4 หลายเดือนก่อน

      Bom dia! Não entendo disso não! Gostaríamos que não tivesse acontecido

  • @francinildosouza3410
    @francinildosouza3410 3 หลายเดือนก่อน +1

    Bom dia amigo oa deixa oxigênio dentro explode por causa do ar com oxigênio os parceiros e quem fala que explode

    •  3 หลายเดือนก่อน

      Informação errada

  • @henriquetannus10
    @henriquetannus10 2 หลายเดือนก่อน

    Se um split tiver um vazamento pequeno e, por exemplo, precisar de repor o gás depois de 1 ano... por causa do vazamento posso assumir que fatalmente entrou umidade no sistema, certo? Sendo assim, o certo seria sempre que for preciso dar carga de gás no split, o técnico deveria recolher todo o gás, mandar o gás para reciclagem, sanar o vazamento, fazer vácuo e colocar um gás novo no sistema?

    •  2 หลายเดือนก่อน

      Procedimento correto