Fire Fighting Pump Installation/ Rules for making a fire pump room
ฝัง
- เผยแพร่เมื่อ 21 ธ.ค. 2024
- Friends, in this video we are telling you what is the rule as per standard for installing a fire fighting pump in a fire pump room and on the basis of what rules the design of fire pump is done as per standard.
Email :-sachinfireofficer@gmail.com
[ THANKS FOR WATCHING THIS VIDEO ]
Sachin Kumar Singh
सर आपने विधिवत जानकारी दी है इसके लिए आपको हृदय से धन्यवाद देता हूं। जय हिन्द सर।❤❤❤
गुड इवनिंग सर बहुत ही सरल तरीके से आपने समझा दिया बड़ा अच्छा लगा
Thank you sir ji...
Your fire and life safety related videos is very helpful thanking you
Sir bahut acchi jankari thank u
Sir ye batayen ki sarkari fireman vacancy ke liye kaun si best book hain jise exam me question A sake. (MCQ) paper hoga sir.please batayen sir
Sir बहोत ही ज्ञान भरा विश्लेषण किया आपने ने , प्रणाम स्वीकार करे ,,, sir फ्रेश इलेक्ट्रिकल डिप्लोमा होल्डर के लिए कोई जॉब हो तो कृपया बताइये ,, आप से मार्गदर्शन की आशा है
Sandaar sir ji
good evening sir
agar fire hydrent line main 8kg presure ho to landing valve se kitna presure relese hoga
Nice information
Thanks for such an informative video
6700 Gpm ka pamp Abu Dhabi airport me lga hai sir mene dekha hai jo Naffco company ne lgaya h
Bahut acha
8 floor building ke liye basement na ho to gr fl pe pump room bana sakte hai kya there is no proper space like 6mt around building... foundation of pump kaise kare
Sir pump testing ka ek video bana dijiye pls 🙏
Sir DV system pe 1 video banaye
Kya gajab video sir,thank you very much sir ji.
Very important information..thanks sir.. Sir ikdi Vedio fire branch k upar banao.... Fire branch ka demo bhi dikhao.. Thanks sir
Sir you write a book on fire your language is simple and clear
Very good morning sir
Thank you Sir
Sir pump capacity kaise nikale
Good
Jy hind sir 🔥
Sir fire line ke metal konsa hota hai
Sir between pumps 0.75 distance hona chahiye ye kis standard ke according he
Ap jo rule batate he o kis basis per batate he NBC or NFPA or any other
The data you are showing is from NFPA or what?
Please provide me the reference.
Jai hind sir
We are installing new hydrant system in our factory, may u guide me regarding butterfly valve for maintenance purpose, how many should I install in our line for better maintenance of line
Follow drawing
sir ji
fire enigen pump auto me kin kaarn chlna chaye
Sir pump kitni capacity hona chaiye ye kis standard me likha he
How to defend how many capacity pump install as per standard
Good explanation
3 phase motor ko neutral ki zaroorat ny hota.
Protection ke liye earth lagta hy.(as per standard double earthing hota hy)
Neutral single phase equipment ke liye hota hy. Agar 3 phase motor ko chalane VFD, push button light, ya koi aur single phase equipment lagta hy toh neutral lete hy.
सर आप क्या काम करते हो
Sir g 3phase motor ko neutral ki zaroorat ny padegi. 3phase motor bina neutral k chalte hy. Sirf panel k automatic contactor relay aur indicators k liye neutral ki zaroorat hogi.
Sir bast video hai
Thank you so much Sir 🙏
sir, good morning ,
please pump capacity divide in ABCE & high risk but why not D...
Hello sir
Response Indicator par ek video banao please
sir v nice
Sir please pump ka pura chapter NBC code ke according Bord pr padhao please🙏
Sir i req u plzzz agr kahi fresher fireman ki vacancy ho toh bataye
12 hour ki duty h 12500 salary de rhhe h sec 39 m h ,Gurgaon m h
@@sandeepahlawat5965 with all deduction ke bd
mahukhera ganj uttrakhand main hai 12,500 8 hrs duty u can try bro
@@aasheeshsharma1313 How can i try any website or any num plz
@@piyush6054 very gd bro
Which NBC code you are refering ? Please provide me the link
Fire vacancy ke related video banaye sir
my big confusion is related to fire diesel engine in auto mode operations , when we put auto mode engine, suddenly start engine,but already header pressure..in header. so why it's start
Sir Fire Cable 2C X 1.5SQMM cable installation rate?
Thnx sir
Sir is ki Coching hoti hai
that's why we can't put in auto.. when ever we plan to take auto mode, suddenly start diesel engine...
Interlocking is not provided in your system
4500 LTR pr mintus meri yha lga huaa he
Inter locking maane automatic work
Good afternoon sir , sir koi fireman ki job ho to batao sir please kafi time se search kr rha hu khi mil hi nhi rhi , muje bahut jruri h sir , m apki videos dekhta hu sir isliye apse request h plz sir
Mere plant Mai 254 bhp DG.
400000 per hour capacity.
🙏🏻🙏🏻🙏🏻🙏🏻🙏🏻🙏🏻
👍👍👌👌🙏🙏
National Building Code for video
Fire watcher responsibility
Sir privat job bataiya please
sachin sir pls messenger pe reply kijiye muje ques me doubt he
meaning M - 15 grade
Fhire nahi bhai fire
Sir apka contact no. Adress bata sakte ho kya
Hello sir aapka what's up no chahiye
its not bhayar pumps its fire pump bro 🤣😂