I am also a static equipment engg. Jo aap ne describe kiya bht Acha aur asaan bhasha me Kiya aisa description jisne h.e par kaam Kiya Hoga wahi bata Sakta hai.. Ek tie rod reh gya but thik hai.
Shukriya paji aaj ye confusion door ho gya Lekin ek bat puchna hai, Jo shell and tube type ke 4 types ke HE hai o sab me 5 hi gasket use hota hai ya kuch alag hai
Nhi sab me 5 nhi use hota h jaise U type heat exchanger h usme 3 gasket use hota h... Dekhiye simple rule yaad rakhiye jitne aapke joint honge jaha se fluid leak hone ka chance hota h waha per gasket use kiya jata hai
Video is very informative..can you add the details of the applications of each type of heat exchangers..like you mentioned kettle type exchangers are used in CDUs and H2 production plants
sonu sir aap ye bataye ki jo tube support baffle hota h wo shell me chipka rahata h nahi yadi hota h to uske aur shell k bich ki gaip se shell inlet nahi hota h
Baffle in Heat exchanger is used for better heat transfer as it guides the steam which results in better heat exchange between two surface, more surface area more heat transfer
Video about types of heat exchanger will be available tomorrow that will clear lots of confusion related types of heat exchanger used in Refinery so please share these videos if you really like it.
Brother it depends upon the application of heat exchanger that means which type of material is treated for heat exchange...But mostly we use metal jacketed 905 type Gasket
Bahut badiya samadhiya apne shukriya bhai jee
I am also a static equipment engg. Jo aap ne describe kiya bht Acha aur asaan bhasha me Kiya aisa description jisne h.e par kaam Kiya Hoga wahi bata Sakta hai.. Ek tie rod reh gya but thik hai.
Bahut bahut dhanyavaad Kamran bhai....
Avi kha kaam kar rhe hai aap?
@@SoNuSiNgHRefinery IOCL PANIPAT
Sir pipe fabricatore ka video banaye plz question answer ka
Shukriya paji aaj ye confusion door ho gya
Lekin ek bat puchna hai,
Jo shell and tube type ke 4 types ke HE hai o sab me 5 hi gasket use hota hai ya kuch alag hai
Nhi sab me 5 nhi use hota h jaise U type heat exchanger h usme 3 gasket use hota h...
Dekhiye simple rule yaad rakhiye jitne aapke joint honge jaha se fluid leak hone ka chance hota h waha per gasket use kiya jata hai
वेरी nyc sir
Sonu ji good morning
Sonu ji plate type exchange kaa hydro test kaisey Katey hai or kitna test hota hai.
Hello sonu bhai let me know why we do shell test after. Pls tell me.
Good Sir Explain video
Sir aap ek video baniye jo gulf ke liye best office
Nice one ❤️
Excellent
Nice sir ji
Sir bundle pull out karna h to us samay mechanical foreman ka kya roll hota h
In this drawing, no Drain and Vent points.
Have there the vent and drain. ?
Video is very informative..can you add the details of the applications of each type of heat exchangers..like you mentioned kettle type exchangers are used in CDUs and H2 production plants
Sure I'll try
Sir please upload hydro test ( Shell test,tube test final test) video
Good job yar
Good 👍
Sonu sir vishal mai Kay maintenance hota hai
Thanku sir for information.
Very good
sonu sir aap ye bataye ki jo tube support baffle hota h wo shell me chipka rahata h nahi yadi hota h to uske aur shell k bich ki gaip se shell inlet nahi hota h
Question aapka samajh me nhi aa rha h phir se puchhiye
Pls make video on HT of heat exchanger
Sir G interview questions bolt tarking pe video banaeye please sir
Rotating equipment ke bare Mai video banaye sir
Please
Super sir
Thanks bro please share if it was helpful to you.
Sonu sir fin fan ka maintenance video add kijiye plz
Kitna gasket used hota h heat exchanger ke 4 type h sabka bata digiye
Hello sir please must give me answer sir what name of exchanger who has inside the shall pipe
Double pipe exchanger
Kis type ka gaskets lagega
Baffle in Heat exchanger is used for better heat transfer as it guides the steam which results in better heat exchange between two surface, more surface area more heat transfer
Thanks for your suggestion.
Kitna pressure use karte h heat exchanger m
Lagne Wale gasket ka kya naam hai or ye kis material ka hota hai?
Sir ap Bata. Skte ho best refinry konsi h
Whr u get the best salary and best working environment.😊
Shell inlet and shell outlet k kya kaam h.
I love you vaia ji.
Sir drawing ke bare me thoda bataiya
Sir Fresher k liye job ho to plz btayiye🙏
Heat exchanger ka minimum or maximum weight kitna hota hai sir
Bhai Ek Tube Expansion ki Video Bhejo
Sir ma BE Chemical engineering kar raha ho to Mana tube ka about Mana suna ka tube pani ka jo flow hota ha na us flow ka time maintain karta ha
😂
How many gaskets in u tube and fixed heat exchanger ?
Thanks Sumit ji for asking I forgot to mention there for U type and fixed tubesheet type there are 3 gasket we use.
Thanks for asking
Video about types of heat exchanger will be available tomorrow that will clear lots of confusion related types of heat exchanger used in Refinery so please share these videos if you really like it.
Witch types of gasket are use in heat exchanger
Different types of gaskets are used as per application of heat exchanger.
Sir how many types of tube sheet
Sir how to test the heat exchanger
And howmany type exchangers
Mujhe do din bad pipe fabricators ka interview Dena h to plz pipe fabricators ka video upload Karen plz sir
Video upload Kiya h pahle hi playlist check kijiye
Nuce
Channel head kis side m hota h or floating head kis side m hota hai
Heat exchanger ke front wale side me Channel head aur pichhe wale bhag jha shell cover hota h waha floating head hota h
Floating head ka function kya kyun use kia jata hai floating head type heat exchanger 🙏🙏🙏
which type of gasket use in Heat exchangers
Brother it depends upon the application of heat exchanger that means which type of material is treated for heat exchange...But mostly we use metal jacketed 905 type Gasket
Sir aap se kitane baar number mag chuke sir aap number send nhi kiye
Tube bundle kha se nikalte hai
Background music is very irritating, please remove it in next videos.
Whatsaap group baniye
sir mujhe heat exchanger full details chiheye
baffle gas ko ditection dayta hai
Tube me kya hota he
Heat exchanger ke application ke aadhar per usme kisi bhi fluid ka flow hota h
Please mujhe fast reply de mujhe kal interview m jana hai ya apna whats up de pls
Okay brother puchhiye...
7007957816
Where is spacers
Sir apne tai rod bolna bhul gye
Sorry brother
Sir apka no.chaiye
😊
7007957816
Nice sir