What Is Pump Down In Hvac. Pump Down Kaise Kare
ฝัง
- เผยแพร่เมื่อ 30 ต.ค. 2021
- Hello Friends Welcome To My TH-cam Channel.
Is vedio Me Bataya Gya Hai Pump down kiya Hai Kaise Karte Hai Aur kyu Kiya Jata Hai.
#hvac#Mractechnician#AfzalAlam - วิทยาศาสตร์และเทคโนโลยี
Great job❤❤❤❤
Good ❤
Masha Allah bhai jaan
Sukriyaa 😍
Very exlant bro
Thank you
Good explain bro, thanks
Nice explanation
Thanks sir video banani k leyai
All the best
Nice bhai❤️
Shukrya janaab
Nice 👍🏼👍🏼
Nice vedio
Thanks yarr
Grate
Gud explain
Thanks
Sir Compressor changing process k upar ek video bana dijiye
Ok
Nice informative vedio, sir plz make also a vedio serious on hvac electric..
Ok Insallah
Thanks sir
Paikej unit ka daygram btaeye sir
Ok wait kijiye bhut jald upload Karenge aapke liue
Bhai chiller ka pump down detels me bataye ek vidio banakar
Ok
सर कंप्रेसर चेंज के ऊपर वीडियो बनाये
Ok
ᴛʜᴀɴᴋs sɪʀ
Running mode me Discharge line ka valve close karenge
Suction line k through pipline evaporator me jo refrigerant hai wo compressor or condenser me store hoga?
Uske baad suction line valve close kr k unit off krna hai
Pumpdown par practical vedio h aap dekhee usme bataya hu karkee kaise karnaa h ...aapki Puri bat ko ham samjh nahi pa rahe h
Outdoor discharge line se lekr indor evap hote hue suction line valve tak ka refrigerant jo hai Kya ye sara refrigerant compressor or condenser me store ho jayega?
Hnnnn ....pump down karkee aap sirf indoor ka Kam Kar saktee h
Sir aap bahut accha bata rahe h but voice
Clear kijye
Ok
Sir agar chiller me solonied valve hota to manually pumpdown karte hai,
Hnnn
Sir jo outdoor me gas Store hota hai who liquid me hota hai ya phir veper me?
Liquid me
Sir Mera sawal ye hai ki .. suction line ko close Karke evaporator me gas Restore kar sakte hai Kya ? matlab Indoor me ? Reply thanks
Nahi .....Kyu ki Compressor fir pumping kaise karega
Agar indoor paroblem aaye to uske liye GRU gas recovery unit ka use karte hai ...aur gas ko bahr kisi cylinder me store karte h
@@Afzalalamhvac apka bahut bahut sukriya reply ke Liye
To kya Cassette ac, Vrf, ductable AC, package ac aur chiller mein bhi isi process se pump down karte hai?
G hn
Kis kis compressor mein pump down hota hai
Mashallah bhai.. you have a
Fabulous way of explanation..
Thanks 😊
सर अगर कंडेनसर को descaling करना है तो evoporetor में गैस स्टोर कर सकते है?
लिक्विड refrigrent कंप्रेसर में जायेगी तो दिक्कत नही होगी
Descaling bade ton of refrigeration system ke machine me karte h ....Uske liye GRU karte h gas recovery unit gas ko bahar calendar me store karte h
Pump down hone ke bad gass kaha pe store hoke rahta hai
Sir please tell me about the suction and discharge preasure of 134a in air cooled chiller
35 to 45 suction pr.
130 to 160 discharge
Aur sabhi refrigerant ka kaise suction discharge nikalte hai uska vedio upload h
@@Afzalalamhvac ac aur chiller dono me same rhta h
Sir packeg ac ma pump down kaise kare
Uska bhi same hi process h chiller package dx sab ka
Sir agar chiller ko band krna h.. To Kya Kya of krna padega... Bms se nhi band krna h...
Chiller of kariyr
Bhaii chillers operator ka salary jyda hota haii ya HVAC technician ka pls batea
Technician ka
Ser mughe HVAC ka interview dena hai to pura questions bta dijiye ki kya kya puchte hai please
2 vedio all ready post Kiya hua interview se related
Chiller kitna ampere leta hai
Jitna ton ka hoga uske according amps legaa
Sir kya pump down karte waqt system blast ho sakta hai?
Blast Nahi hoga high amps ya overload se trip ho jayega.....ya compressor ke andar machenical part damaged Hoga jayad time valve band karke rakhte h to....hn rare case me blast ho Sakta last situation me
Sir aapki aawaz clear nahi hai matlab jo bol rahe hai utna samjh me nahi aa rahi hai achha se boliye saf saf boliye
Ok thik h is par dhyan denge next vedio me
Kis kis chiller mein pump down hota hai
Reciprocating aur scroll screw rotary...isme ho jataa h .... centrifugal me alag store karte h
Kis kis compressor mein pump down nahi hota hai
Jayadh ton off refrigeration system ko ...Gru karte h ...gas recovery unit gas ko alag store kartee h ..kyu ki usme sabhi area me gas hote h
Kis kis chiller mein pump down nahi hota hai