I have 4 wires comming out of my indoor to outdoor one is live second is netural and third is ground so for what purpose fourth wire is and my outdoor has only 3 connector
The first one is phase and second is neutral and third one for communication wire. And you told that you have only 3 slots. Then earth connect with outdoor body.
@@GayatriAirZone i have seen on my outdoor 3 pins one is mentioned live second is netural and third is ground were should I connect communication wire?
Ya to fan ki wajah se noise aa rha h body se sahi connect nhi h ya fir compressor noise kr rha Hai Ya fir jis surface par rakha h waha balance sahi nahi Hai
सर, मेरे यहाँ जो अंडरग्राउंड पाइपिंग हुई है उसका साइज 12mm और 6mm है जो कि 1.5 टन की मशीन के लिए सूटेबल होती है। मेरे को 2.2 टन का AC लगाना है, जिसके लिए कम्पनी कहती है कि 15mm और 6mm की पाइपिंग होनी चाहिए। क्या 12mm वाली पाइपिंग से ही कनेक्शन करने पर पूरी कूलिंग नहीं मिल पाएगी?
Very Nice. I have changed capacitor myself by seeing this video. Great Work!
My pleasure
TQ Bhai ji apke ye video best hai
Bhai Daikin me old model me Jo contor atahe us ki jagah par reguler contracter kese lagye us par vidieo banavo
I have 4 wires comming out of my indoor to outdoor one is live second is netural and third is ground so for what purpose fourth wire is and my outdoor has only 3 connector
The first one is phase and second is neutral and third one for communication wire. And you told that you have only 3 slots. Then earth connect with outdoor body.
@@GayatriAirZone i have seen on my outdoor 3 pins one is mentioned live second is netural and third is ground were should I connect communication wire?
Agar contactor hata de to koi problem hogi indoor pcb me..?
Nhi
Mere daikin ko sadhe 6 saal h split ac usme kl us bnde ne capacitor lga dia epcos ka.... Muje kuchh ni pta ta ab lgra gdbd h pls btao
Problem kya Hai ac me
@@GayatriAirZone hwa Kum t aur cooling bhi Kum thi aur jlne ki hlki smell t aur hlki awaz b pr 2016 m lia hai
Service krwao ac ki or wiring or motor check karwao
Outdoor to much noisy purchase last day but sound like drill machine or replacement Kiya Outdoor same problem kya reasons hoga sir
Ya to fan ki wajah se noise aa rha h body se sahi connect nhi h ya fir compressor noise kr rha Hai
Ya fir jis surface par rakha h waha balance sahi nahi Hai
Visit technicians pipe touch and both unit sound same noise
WHT did he said ?
भाई आउटडोर के लिए सप्लाई कहा से देना है मेन मीटर से देना या नॉर्मल बोर्ड से
Supply power plug se bhi de sakte ho bas wire 2.5mm se upar ka hona chahiye
Same sound Ata Hai sir it's normal na
Daikin split inverter AC hai non inverter banana hai indoor ka pcb chenge karna padta hai kiye
Nhi bas compressor change krna padega or outdoor ki pcb hata k contractor laga dena
@@GayatriAirZone contractor jaroori hai indoor se to cp comnition to aayega na to contactor q
Safety for compressor
Bhai running wire starting wire ko acche se batao is ka kya kaal h
Good practical
Thank you 👍
Aapne red wala compresar me starting lagaya hai our bhai fir aapne usko ranning bana diyq
Sir g ap iski pcb ki wiring ki bhi video bana dijiye please sir g
Thrnk you sar
सर, मेरे यहाँ जो अंडरग्राउंड पाइपिंग हुई है उसका साइज 12mm और 6mm है जो कि 1.5 टन की मशीन के लिए सूटेबल होती है।
मेरे को 2.2 टन का AC लगाना है, जिसके लिए कम्पनी कहती है कि 15mm और 6mm की पाइपिंग होनी चाहिए।
क्या 12mm वाली पाइपिंग से ही कनेक्शन करने पर पूरी कूलिंग नहीं मिल पाएगी?
Ho jayega usi me
@@GayatriAirZone ok
210sqft के ड्राइंग रूम एरिया के डाइकिन 1.8 टन (6400वाट) नॉन-इन्वर्टर सही रहेगा या फिर कोई और नॉन-इन्वर्टर?
@@V98000 direct sunlight ho room par to non inverter warna inverter le lo
Samjh me nhi aaya Bhai running stating sahi se batao
Bhai cp ka wire hai wo samaj me nahi aaya hai
Line natural or cp se bas Jo kaam aayega wo cp or natural hoga line wire ko kisi me connect nhi karna
Nice video
Thanks bro
Bulu wair kaha laga huwa hranig se
Phase ya neutral
Isme contactor nahi hai bhai
Yes contractor wali alag se bnai Hui h video
Thanks bhai