main bar ku span 6000mm eduthom , cutting length ku span 4000mm edukurom, why? Distribution bar ku span 4000 edukurom , cutting length span ku 6000 edukurom, why? can u explain
Sir corner la beam end iruku. Ippo development length 40d solringa. Athavathu 40*12-480mm. Examble corner beam size width 300mm iruku na epdi 40d formula use agum? My tout sir. Atha mathiri centre la beam 300mm iruku.so appavum 40d vacha beam thandi atutha slab area ku pogum la.pls tell me
Top extra bar la no.of bar ~no.of main bar nu one way slab la sonninga bt itula vera formula use panringa Rendukum orei formula va illa vera vera formulas use pannanuma Plz reply me brother
Good explanation bro keep it and we need more information for BBS Calculation
Excellent information brother. Thank you so much.
Thank you.
Useful information bro
Thank you so much
Easy for understanding bro..🔥
Sir Vaasthu pathi oru video podunga..
Vera level bro 😎
Two way slab ku shorter span la mattum crank pannanum neenga eppadi longer span la eppadi crank panna soldringa
inches use panunaa practicalaa apply panna inum easyaa irukum bro...
yes i will do.
4.38 minitus la...... Slab oda Crank Height ah calculate pannum bothu cover 15mm thana minus pannaum.... Beam ku thana 25 mm cover varum bro 😉
Ipo elam beam ku 30 mm cover & slab 25 mm cover kudukuraga @125 mm thickness slab size ku... For slum board building 🏢
Hi . Really good... Can you put a video for U bar slab please
Top extra bar length L/4 thane varum
main bar ku span 6000mm eduthom , cutting length ku span 4000mm edukurom, why?
Distribution bar ku span 4000 edukurom , cutting length span ku 6000 edukurom, why? can u explain
Anna extra bar na curtailment aah??
10:59 minutes laa no of bars double la poodurikika ( = 7 + 7 ) in top bar. Athu yen konjam puriyala konjam sonna Nalla irukum brother....
Two side bar need ok
Distribution barod crank height H find pannum pothu main bar minus paitu then distribution bar oda half dia thaana edukanum?
Anna oru house plan pottu tharanglaa
top extra distribution ok,but top extra main bar is not given sir,anyway information is very usefull sir..thank you...
Bar bending schedule for footing and coloumn podunga bro
Sir footing and column distance calculation yappadi sir analysis pannuruthu sir,please solluga sir
Bro extra bar details explain pannuga doubt ah iruku
In two way slab no distribution bars .all are called main bar
Yes you are right. Thanks for giving feedback. yes, Technically both are main bars. to differentiate the direction i used the term distribution
bro while we are adding 1d for 45 degree crank ... why we are multiplying 1d along with 2?
Sir corner la beam end iruku. Ippo development length 40d solringa. Athavathu 40*12-480mm. Examble corner beam size width 300mm iruku na epdi 40d formula use agum? My tout sir. Atha mathiri centre la beam 300mm iruku.so appavum 40d vacha beam thandi atutha slab area ku pogum la.pls tell me
development length beam mudium bodhu bend panni column kulla dha viduvom next slab ku pogadhu
You are correct. Why should we calculate Dia here? Need only developmental length. It should be 40 * 2
Thank u so much bro ❤️
Welcome 😊
Thanks brother 😁
Crank length =1.42*H
Bro for 2 way slab 2(0.42H) illaya bro because 2 side Crank irukumlaaa bro
Sir, why we are taken larger value of span as ly and smaller value of span lx....
Where main bars need to place, bottom or top. How to place extra top bar.
Bro two way slab ku mattum than bar bending varuma one way slab ku varatha
need to do for all steel work in all members
Bro H find pandrathuku 25mm 25mm cover minus pandringa OK but half Dia half Dia ethuku epadi nu puriyala so please could you explain
Effective cover=clearcover+d/2
Top extra bar la
no.of bar ~no.of main bar nu one way slab la sonninga bt itula vera formula use panringa
Rendukum orei formula va illa vera vera formulas use pannanuma
Plz reply me brother
It depends on drawings
Two way slab la enna main, distributor , long short ellam ? Two way la rendumae main bars than.
Thank you for your valuable feedback
super sir 👌
Why we are adding +1 to find no of bars??
Super bro
Super information bro...
1 doubt ...?
Cutting length formula'la develoing volue (40) consdant'a....?
And +(0.42 H) idhula 0.42 consdant volue'va....
Pls explain this doubt .....?
Thanks...
Indian Standard value 0.42xD
D=height
Bro two way slab ku excel sheet upload panuga bro......
ok sure. i will upload
Nice video bro... 🥰😍
Thanks 🤗
Doing good job
Thanks
Nice
Romba long explain pandra. Short a explain pannunga
subtitle please
I try to upload
Nice
Thanks