8 Things Sewage Pump Owners NEED to Know

แชร์
ฝัง
  • เผยแพร่เมื่อ 1 ก.พ. 2018
  • Learn the top 8 tips and tricks for your septic pumping system!
    1. Using a test gauge to read pressure at startup will allow you more insight when something goes wrong. (check for faulty check valve, pump, leaks, etc.) This also allows you to verify the pump is operating as it should during the initial installation using the pump curve. Check them out on our website: www.rcworst.com/Discharge-Ass...
    2. Most pumps include 2 nameplates, take one and stick inside your control or breaker panel to easily remember model number and date of manufacture for warranty and repair
    3. Eventually, you will need to replace your pump, when that day comes make sure you buy a pump that has an easy warranty process if you are a do-it yourselfer. An easy to process warranty means you won’t have to spend loads of time chasing down a replacement if something should happen. (I see this all the time)
    4. If I had to pick one quality that seems to separate quality pumps from low quality seems to be the upper bearing. So if you want to only remember one thing to look for without checking every option and feature then pay attention to the upper bearing. If a bushing is used that is an indication of a cheaper motor that will likely not last as long as one with an upper ball bearing construction.
    5. You cannot purchase a quality professional grade pump from a big box store such as Home Depot or Lowes or even Ace, most professional grade pumps need to be purchased from a distributor. Most distributors sell pumps to the public but most people don’t know that. The easy way to get professional grade pumps is to shop with rcworst.com where we sell at competitive prices direct to the public and all our prices and stock levels are shown online.
    6. Be proactive with ownership of your system, ask questions and learn how it works, know who you are going to call when things are not working as they should ahead of time. Knowing your system inside and out will help you save money and stay away from “Emergency Situations”.
    7. Watch what you flush! Don't put any waste that didn't come out of your body or toilet paper down the toilet.
    8. Know how to turn your pump on manually.
    Have a question? You can live chat with us at www.rcworst.com/, call 855.329.4519, or email Customer.Service@RCWorst.com to speak with an industry expert.
    Add us to your professional network: www.linkedin.com/company-beta...
    Follow us on Twitter: / rcworst
    Like us on Facebook: / rcworst
    For more industry videos visit our TH-cam Channel: / @rcworstwater
    We are a distributor of pumps, packaged pumping systems, on-site wastewater treatment equipment, on-site wastewater treatment systems, and custom electrical control panels for water and wastewater applications, water well supplies, drilling supplies, and water treatment equipment.

ความคิดเห็น • 119

  • @greybeard9x44
    @greybeard9x44 4 ปีที่แล้ว +8

    Excellent and clear video! The sort of thing that good USA businesses do so well!

  • @lorenarmentrout9635
    @lorenarmentrout9635 4 ปีที่แล้ว +2

    Great information seriously, thank you very much! I was able to fix my pump just by watching this video!

  • @meta_noia
    @meta_noia 4 ปีที่แล้ว +5

    Very good video. Concise and honest. Good job!

  • @-ultravic661
    @-ultravic661 5 ปีที่แล้ว +18

    I wish a lot more company vids were like this. A little advertising for you and a lot of valuable info for me. Thank you RC Worst.

    • @RCworstwater
      @RCworstwater  5 ปีที่แล้ว

      Thanks for the kind words and for watching! :)

  • @BlackFlux22
    @BlackFlux22 3 ปีที่แล้ว +1

    Awesome presentation and outstanding information. Thank you Rcworst

  • @larrykent196
    @larrykent196 3 ปีที่แล้ว +1

    That's good information. Thank you... the humor was good... Cheers!

  • @ashleydecker9572
    @ashleydecker9572 ปีที่แล้ว +2

    Thank you. We live in MD, and our pump just went out. I was watching this video and had my husband watch as well. We gave you guys a call they match our pump, talked to us about options differences in the pumps and other things. We got educated. Best part even with shipping from Idaho they still beat any price in our area. Great customer service and knowledgeable sales rep. THANK YOU

    • @RCworstwater
      @RCworstwater  ปีที่แล้ว

      Thanks for the stellar comment Ashley!

    • @Duffr1234
      @Duffr1234 2 หลายเดือนก่อน

      In the meantime, how are you going to the bathroom since considering all the gray water runs through your system did you move out of your house till the pump arrives?

  • @hagif.4590
    @hagif.4590 3 ปีที่แล้ว

    Thank you for the great and informational videos you make !
    I live in israel and have an italian stainless steel 1HP sewage pump which seems to be too strong for my 40mm 6 meters drain output. I've installed a 40mm Y splitter and considred leaving 20mm opening for some of the water to go back to the septic tank, So it won't make damages to the 70+ years old house plumbing because of the excess pressure of this strong pump on the plumbing.
    How would I know how much of the pressure to relieve in the Y splitter ? I've considered installing a ball valve in the output of the Y splitter to control the outflow of water back to the tank. What do you think ?
    Thank you

  • @elbowmacaroni2319
    @elbowmacaroni2319 3 ปีที่แล้ว

    Very good video.....appreciate the tips. My waste water pump is about 10 years old. I usually clean out the tank every 6 months. It is starting to pump slower with longer pump cycles. Is it common for the impeller to get clogged up with debris?

  • @ericbuentello9703
    @ericbuentello9703 3 หลายเดือนก่อน

    Great video man! You were made for this

  • @juang2025
    @juang2025 5 ปีที่แล้ว +3

    Is there a measurable comparison in longevity between an upper ball bearing pump and one with a bushing ?? Thanks

  • @terrylauber5698
    @terrylauber5698 6 ปีที่แล้ว +4

    Thanks for an informative video!

    • @RCworstwater
      @RCworstwater  6 ปีที่แล้ว

      You bet Terry! Thanks for watching :)

  • @Stuffandthingstoknow
    @Stuffandthingstoknow 2 ปีที่แล้ว

    Great video! Thank you

  • @isaaccurry7322
    @isaaccurry7322 4 หลายเดือนก่อน

    Great video! Very informational. My float was malfunctioning on my 2017 2 HP Zoeler grinder pump. After pulling it, I found a crack in the float. Can you give me an estimate of what a new float and a new switch would cost to have installed on this unit?

  • @Yabbadabbadoo980
    @Yabbadabbadoo980 5 ปีที่แล้ว

    Hey great video so I have a septic system and my pump went so I need a effluent pump of sewage pump for the grey water discharge from the tank to the leach field

    • @RCworstwater
      @RCworstwater  5 ปีที่แล้ว

      Give us a call Timothy: 855.329.4519

  • @mikeh2291
    @mikeh2291 3 ปีที่แล้ว +3

    I am new to sewage sump pumps but now have one in a house with a bathroom below the main sewer line.
    I recently learned that not all of these pump systems have a high-water alarm to indicate a problem.
    Perhaps another tip would be to be sure that your existing sewage sump pump or a replacement pump has one of these alarms.

    • @RCworstwater
      @RCworstwater  3 ปีที่แล้ว +1

      Good tip!

    • @BasementEngineer
      @BasementEngineer 5 หลายเดือนก่อน

      It is possible to retro-fit a high water alarm without disturbing the existing set-up.

  • @truenorthmuskoka9077
    @truenorthmuskoka9077 3 ปีที่แล้ว

    I have a septic system with a third tank where the effluent goes into. From there it gets pumped uphill to a drain field. I was told to remove the check valve so that effluent drains back into the pump chamber preventing the pipe to the drain field from freezing in our cold Canadian winters. Any thoughts on this.

  • @drclean04
    @drclean04 ปีที่แล้ว

    Awesome video thanks for sharing

  • @jenniferbmendezful
    @jenniferbmendezful 2 ปีที่แล้ว

    Great video.

  • @kuyayan
    @kuyayan ปีที่แล้ว +1

    I like this guy 👌 and company!

  • @sydneybingham7564
    @sydneybingham7564 4 ปีที่แล้ว

    Thanks for the video! My pump is located outside, and with freezing temps in my area, that seems like it could be an issue. How do you insulate sump pumps?

    • @RCworstwater
      @RCworstwater  4 ปีที่แล้ว +1

      The pipe needs to be buried below the frost line and the pump installed below it as well. Insulation is usually only done on the lid with some foam.

  • @panchowake
    @panchowake 3 ปีที่แล้ว

    Great video! Quick question: Can you use a sewage macerator pump to pump the effluent of an insinkerator? Thanks!

    • @RCworstwater
      @RCworstwater  3 ปีที่แล้ว

      Give us a call to discuss your application: 855.329.4519

  • @ReverendHogwash
    @ReverendHogwash 6 ปีที่แล้ว

    Question: System has a 2" pvc vent and 2" discharge sine those are actually 2.375 I need a 3x3 cover right?

  • @ffc3476
    @ffc3476 3 ปีที่แล้ว

    Thanks for sharing

  • @snowbird29803
    @snowbird29803 6 ปีที่แล้ว

    Good information...Question: Are there any special considerations in choosing a pump or system for a residential RV dump (used occasionally)? The entire volume of the Black tank effluent will rush in to the pit at once up to the max volume of the RV tank...maybe 40 Gallons. Can the inlet be right through the lid of the pit, or is there any reason to pipe it in to the pit side from some reasonable distance away? IOW, locate the pit somewhat removed from the dump hookup? Freezing is not too significant here in the South East U.S.,but any advice on that? The outlet will go roughly 75 feet away, but only a foot or two elevated. Tnx

    • @RCworstwater
      @RCworstwater  6 ปีที่แล้ว +1

      There are definitely some things to consider, I would recommend you give our tech line a call to discuss your application: 855.329.4519

  • @user-yn2cb8pn3m
    @user-yn2cb8pn3m 9 หลายเดือนก่อน

    Great video - I currently have a Hydromatic SPD50AH1 20 pump and having a issue that keeps tripping the breaker. I bypassed the float switch, pump starts to pump the water to the septic and after 10 seconds it trips the breaker. I removed the pump and i found some what looked like hair on the bottom and removed it. Same issue. I also checked the septic tank and it was pretty much full so i had it pumped thinking that was the issue but still same issue. The pump build is 07/07 - could it also be a plugged pipe going to the septic?
    Is there anything else i should check before i buy a new pump?
    Can the pumps be repaired or just buy a new pump

  • @RyanCianfarani
    @RyanCianfarani 5 ปีที่แล้ว +7

    Thanks for the tips! Quick question for you: Do you recommend performing annual cleanings on the pump?

    • @RCworstwater
      @RCworstwater  5 ปีที่แล้ว +5

      On a residential system, typically not. Routine cleanings are generally only needed if your pump is prone to clogging or if you have an effluent filter.

    • @mekonnendengoro1879
      @mekonnendengoro1879 4 ปีที่แล้ว

      Yes Excellent

    • @daxtonmaison7609
      @daxtonmaison7609 3 ปีที่แล้ว

      I realize Im kinda randomly asking but do anyone know of a good website to stream newly released movies online?

    • @cooperfrederick218
      @cooperfrederick218 3 ปีที่แล้ว

      @Daxton Maison flixportal =)

    • @daxtonmaison7609
      @daxtonmaison7609 3 ปีที่แล้ว

      @Cooper Frederick Thanks, signed up and it seems like they got a lot of movies there =) I really appreciate it !

  • @lvoss2534
    @lvoss2534 ปีที่แล้ว

    I’m watching MANY of your videos and will be calling you. Suggestion: for Myers or Zoeller pumps you seem to carry, can you rate light to heavy duty? Mine (septic-2 tanks w effluent filter, pump 100’ to leach filed, 10’ lift) fails every 2-3 years. I HATE fixing it. I’ll PAY if it will run for 10 years. What do I buy? What makes these fail? Should I be upgrading to external/redundant floats? So frustrated brother! And DON’T bother calling local-they love me LOOONG time every time it fails! 😅

  • @dwightwillmon8134
    @dwightwillmon8134 ปีที่แล้ว

    Very helpful

  • @ampfly9601
    @ampfly9601 4 ปีที่แล้ว +1

    Good stuff ,,,,

  • @seg316
    @seg316 5 ปีที่แล้ว

    Have you or do you know if one of your customers has installed an effluent pump inside a pump screen? I am looking to filter out as much of the solid material as I can and I am looking at a pump screen and a pressure filter. If you would prefer I can call in and tell you the exact make/model of pump I will be using and the manufacturer of the pump screen and pressure filter.
    Thanks!

    • @RCworstwater
      @RCworstwater  5 ปีที่แล้ว

      We Install effluent pumps in pump screens all the time! Give us a call and we can help you with yours: 855.329.4519

  • @nadirattiah665
    @nadirattiah665 4 ปีที่แล้ว

    Great tips,
    What is average warranty on pumps with different manufacturers?

    • @RCworstwater
      @RCworstwater  4 ปีที่แล้ว

      With sewage pumps it can range from 1-3 years, with the most common being a 1 year warranty.

  • @oseusa3063
    @oseusa3063 4 ปีที่แล้ว

    Hey Chris I have an MQ ST-2005A and the motor gave out and I want to fix it, what should I do, buy a new motor $380 plus shipping or have it repaired, Thanks love the Vids

    • @lukeWiz44
      @lukeWiz44 4 ปีที่แล้ว +1

      OSE USA if it's the motor, and your sure it's not the switch, you need to replace it. There is no way to repair the motor as it is most likely corroded beyond repair. Hope this helps.

  • @rothros
    @rothros 3 ปีที่แล้ว

    What type of pump are you showing in front of you? I’m trying to replace a new pump.

  • @bus-fun-addict
    @bus-fun-addict 2 ปีที่แล้ว

    Hunk-a-junk peice a pump! Beautiful!

  • @pgfisher8652
    @pgfisher8652 2 ปีที่แล้ว +1

    Great video. I’m looking at buying a house down a hill approximately 30 feet below the city sewer line and 450 feet off the road. This house has a outside sewage sump basin and pump as you described. Is the 30 elevation rise and 450 run to the road a reason to be concerned with this type of system? Thanks for any info.

  • @mytube30005
    @mytube30005 4 ปีที่แล้ว +2

    Is the Grinder Pumps the same thing as sewage pump? I bought a what they called "Sewage Check Valve" for using with my basement pump (looks like the green pump in the video) but it printed on the check valve "Not for use with grinder pumps". So, I'm confused. Would someone please explain? Thank you!

    • @RCworstwater
      @RCworstwater  4 ปีที่แล้ว +1

      Grinder pumps utilize a cutter on the bottom to macerate solids before they are pumped. Sewage pumps simply pass the solid whole through them. Sewage pumps usually have a 2" discharge whereas grinders have a 1.25" discharge since they are just passing slurry through them.

  • @timalderton5055
    @timalderton5055 2 ปีที่แล้ว

    What's the average life-expectancy of a Myers SRM4 sewage pump?

  • @highway2run
    @highway2run 2 ปีที่แล้ว

    You da man!

  • @500hardcore
    @500hardcore 4 ปีที่แล้ว

    Can I use a Zoeller m267 pump, for a bathtub, 2 sinks, washer, and floor drain?

    • @kevrides5706
      @kevrides5706 2 ปีที่แล้ว

      What pump did you end up going with?

  • @beckywilliams9953
    @beckywilliams9953 3 ปีที่แล้ว

    Our builder installed a Liberty 281-2 pump for our sewage. Since we are very very concerned about this being actually a sump pump rather than a sewage pump I would really like to know what your thoughts are. We have had sceptic tanks always and never had a pump. Our concern is this thing is never going to last more than a few months if that long since it seems to be a sump pump rather than a sewage pump. We would really like to have your input. Why he installed the system ss he did is a puzzle since we actually had plenty of space for the lines behind the home rather than him running them up a hill 15 foot or more.

    • @kevrides5706
      @kevrides5706 2 ปีที่แล้ว

      How is your system working today?

  • @Shoesforshoob
    @Shoesforshoob ปีที่แล้ว

    If our alarm had gone off and followed the steps to plug the pump directly, then the alarm stops. So we assume it's cleared and doesn't require further repair? Thanks for your tips.

    • @RCworstwater
      @RCworstwater  ปีที่แล้ว +1

      You may need a new pump switch.

  • @pabloleal1180
    @pabloleal1180 3 ปีที่แล้ว

    Please help,, I have 2 drummond 1/2 horsepower submerg pumps,,, both have broken impellers,, unable to find replacements,, model 63323... can you help me find replacement impellers... thx... I bought from harbor freight,, they gave me refund but need impellers,, pumps seem to work fine...

  • @murph55
    @murph55 4 ปีที่แล้ว

    do you offer a amp meter for the control box?

    • @RCworstwater
      @RCworstwater  4 ปีที่แล้ว

      We do not sell meters, but you can find them relatively cheap (less than $20) at your local box stores. Look for the clamp-on amp meters

  • @info8947
    @info8947 4 ปีที่แล้ว

    What is the formula for H.P.=feet height ? [how much hp is needed to lift 5' high?]

    • @RCworstwater
      @RCworstwater  4 ปีที่แล้ว

      HP and pressure a pump can produce are not directly related because the pressure/flow capacities differ depending on the model, impeller type, volute clearances, RPM, etc.. Give us a call if you need help sizing a pump: 855.329.4519

  • @ranat5526
    @ranat5526 3 ปีที่แล้ว

    My basement pump failed after 10 years of usage in Pakistan. I fitted a Chinese pump and it broke down after 6 months now I am looking for answers as locally bullet proof pumps are no-longer on the market.

  • @dannyfoy6461
    @dannyfoy6461 5 ปีที่แล้ว

    My lift pump is just running all the time I unplugged it to turn it off did not want to burn out the pump any suggestions on why it is running
    Reply

    • @traskstoneworks
      @traskstoneworks 4 ปีที่แล้ว +2

      Could be you float switch is hung up.

  • @alihapali
    @alihapali 5 ปีที่แล้ว

    can you recommend a small sewage pump please

    • @RCworstwater
      @RCworstwater  5 ปีที่แล้ว

      Check out our video: th-cam.com/video/cmxSpE9HMw8/w-d-xo.html

  • @elbowmacaroni2319
    @elbowmacaroni2319 2 ปีที่แล้ว

    I replaced the float switch and drilled a 3/16 vent hole in the pipe just above the waste water pump and below the check valve to prevent air lock. The pump is approx. 11 years old, 1/2 HP> It pumps very slow while the water is spraying from the vent hole inside the tank. The plumbing from the tank runs across the whole length of the west wall of the basement and the south wall exiting the basement in the corner of the south and east wall. About 35 -40 ft. of 2 " pvc pipe. Does this sound like the plumbing could be plugged up or the pump is wearing out? .

  • @andrewengland971
    @andrewengland971 4 ปีที่แล้ว

    How does a sewer line hold pressure when it’s vented?

    • @RCworstwater
      @RCworstwater  4 ปีที่แล้ว +1

      The weight of the water is usually the only thing "holding" pressure. In sewage systems it is an open loop so no pressure builds up anywhere but the lowest points.

    • @andrewengland971
      @andrewengland971 4 ปีที่แล้ว

      I’m just trying to understand the pressure gauge. Doesn’t make any sense to me. Pressure would build if you had a belly or more but idk

    • @RCworstwater
      @RCworstwater  4 ปีที่แล้ว +1

      @@andrewengland971 Oh, gotcha. The idea with the pressure gauge is to close a ball valve in the discharge pipe and run the pump. With the loop closed the pressure on the gauge should rise to the max pump pressure, so if it doesn't you know you've got an issue with the pump.

    • @andrewengland971
      @andrewengland971 4 ปีที่แล้ว

      R.C. Worst & Co., Inc. right makes a lot of sense now lmao

  • @toycelica185
    @toycelica185 3 ปีที่แล้ว

    👍🏻

  • @annamarieromano3882
    @annamarieromano3882 4 ปีที่แล้ว

    Do you sell refurbished septic pumps?

    • @RCworstwater
      @RCworstwater  4 ปีที่แล้ว

      Our bargain cave is mostly older stock (6 months+), but we may have one or two that we fixed shipping damage on in there: www.rcworst.com/clearance

  • @jeanboy8322
    @jeanboy8322 2 ปีที่แล้ว

    Someone is selling a water/sewer pump station, should I buy it? I'm just looking for an investment. I don't really know anything about a pump station.

  • @markglisson7723
    @markglisson7723 4 ปีที่แล้ว

    can you hook a toilet directly sewage pump

    • @RCworstwater
      @RCworstwater  4 ปีที่แล้ว

      No, you need a tank of some sort.

  • @RRaucina
    @RRaucina ปีที่แล้ว

    No need for ball bearings top or bottom in the typical USA made effluent pumps. They are oil filled and the top bearing is just a bushing or a bore in the cast iron. The bottom bearing would be a kingsbury type bearing running in oil and far superior to any ball bearing. they are essentially zero friction and outlast the motors.

  • @troytruong8170
    @troytruong8170 5 ปีที่แล้ว +1

    If u could open it up Nd fix one

    • @RCworstwater
      @RCworstwater  5 ปีที่แล้ว

      We'll add it to the list!

  • @drewbush6535
    @drewbush6535 ปีที่แล้ว

    👋👍

  • @HelloSailorboy
    @HelloSailorboy 4 หลายเดือนก่อน +1

    Re tip 7. Another way to state it is: Deposit nothing in your toilet that hasn’t been eaten first!

    • @GY6SCOOTERCHAT
      @GY6SCOOTERCHAT 3 หลายเดือนก่อน +2

      What about toilet paper?

    • @jeffb215
      @jeffb215 หลายเดือนก่อน

      Thanks

  • @davejoseph5615
    @davejoseph5615 ปีที่แล้ว

    When the drain field is located uphill from the tank do you want a large high-capacity lift pump? Do you really want to quickly pump hundreds of gallons to the drain field? Drain fields are going to degrade over time and accept water more slowly.

    • @benc1927
      @benc1927 ปีที่แล้ว

      Needs to be powerful enough to lift to the rated height. The pumps have a lift ratings, will burn out the pump early if exceeding it

  • @misfitz2883
    @misfitz2883 4 ปีที่แล้ว +1

    You kind of sound like Pete Davidson

  • @tonnair1210
    @tonnair1210 3 ปีที่แล้ว

    my plumber said he gonna install this outside the house not at the basement because its going to stink is that right?

    • @RCworstwater
      @RCworstwater  3 ปีที่แล้ว

      All sewage pump installations should be airtight and vented. If there is a smell it means it was not installed properly.

    • @bus-fun-addict
      @bus-fun-addict 2 ปีที่แล้ว +1

      Correct! Install it outside if possible. If you have a problem you will be glad its out of your living space. 25 years ago this was common practice with few exceptions. The new way of doing many things are often profit driven and do with no concern for the big picture. Put the pump outside!

  • @JoeRocket-sf6qs
    @JoeRocket-sf6qs 4 ปีที่แล้ว

    No plumber I know will pull that pump.

  • @JohnDoe-du1no
    @JohnDoe-du1no 5 ปีที่แล้ว +2

    Propaganda

  • @MrBillpops
    @MrBillpops 3 ปีที่แล้ว

    Worst self promoting vedio. Not a single word about pumps with integral float switches and NO piggyback plug. Or how to repair the problem of the float switch constantly failing due to calcium build up. Thus putting weight on it so it does not rise up and turn on the pump.

    • @RCworstwater
      @RCworstwater  3 ปีที่แล้ว +1

      If you have questions about a specific situation feel free to call us: 855.329.4519