  • @audiomotivation296
    @audiomotivation296 4 ปีที่แล้ว +2

    What you need to do to make when in the end machine make backtack the needle and that other thing lift it should be when you press 6 twice but they lock that option what i need to do to on lock that option? Its efka variocontrol 850

  • @Simpen84
    @Simpen84 3 ปีที่แล้ว

    What parameter settings are you using to get the solid stop of the needle in the up/down position? Ive got the AB321A/DC1550 on my Seiko SLH-2B-FH-1 and the needlebar kind of bounces up and down a little bit after each stop. Makes me wonder if the motor have enough holding power to actually brake the heavy handwheel and bring it to a stop? Transmission ratio is set at 242, due to the 63mm motor pulley and the 260 mm handwheel, this reduced the amount I can adjust in parameter 219 (braking power at stop of drive). I assume the normal range of 0-55 has been reduced due to the 4.21:1 transmission ratio since I can only bring para 219 up to 14. Thanks in advance.

  • @thomasdesilets7102
    @thomasdesilets7102 4 ปีที่แล้ว

    how we disable the stitch counting ??? on the 810 its too easy but not on 820

    • @camatronsewing
      @camatronsewing  4 ปีที่แล้ว

      It should be the same procedure on the 820. If you go to the EFKA book , the instructions are the same for both panels

  • @mdhafejurrhaman2230
    @mdhafejurrhaman2230 5 ปีที่แล้ว

    how to reset this variocontrol 820???