ความคิดเห็น •

  • @timematters800
    @timematters800 5 ปีที่แล้ว +9

    Thankyou for this video .. it's most definitely the best information i've found thus far on the internet regarding water pumps and how they're used. !

  • @bharatshahane5415
    @bharatshahane5415 3 ปีที่แล้ว +2

    Informative and well made video! Your effort appreciated, thank you!

  • @MrAmrit90
    @MrAmrit90 3 ปีที่แล้ว +1

    very informative video my doubt cleared as you have shown the inlet filter use

  • @mr.vikash9343
    @mr.vikash9343 4 ปีที่แล้ว +4

    Brilliant installation thank you sir ❤️

  • @shinyheart3373
    @shinyheart3373 5 ปีที่แล้ว +2

    Good! Instructions were clear. 👍

  • @magicianjoshiji
    @magicianjoshiji 5 ปีที่แล้ว +2

    Wow good dear I'm first time see

  • @mboowashafiq1496
    @mboowashafiq1496 5 ปีที่แล้ว +1

    Sir thank very much the video was just clear,,,I guess me to now I can install mine to

  • @conesillyvalley7182
    @conesillyvalley7182 5 ปีที่แล้ว

    Glad u showed "earth" connection to pump body. Yours is temporary connection for construction but for permanent connection shut off valve should be provided...

  • @RajeshRanaTH
    @RajeshRanaTH 4 ปีที่แล้ว +1

    Good knowledgeable video

  • @lostpung
    @lostpung 4 ปีที่แล้ว

    Excellent video and the details

  • @globalinfocom6351
    @globalinfocom6351 3 หลายเดือนก่อน

    Why they put rubber seal in discharge head..... Any idea

  • @pramodmali3950
    @pramodmali3950 3 ปีที่แล้ว

    Bhai hamare pass Crompton ka self priming 1hp ka pump hain.kya usme baar baar pani dalna padega kya?

  • @deepp60
    @deepp60 4 ปีที่แล้ว +2

    Very nice Bhai....
    Kya ye pump ground floor se first floor thak, Pani ko pahuncha saktha he kya???

  • @vd7261
    @vd7261 3 ปีที่แล้ว +1

    भाई 200 फिट दूर से सरकारी पाइपलाइन से पानी खीचने वाला और फिर अच्छे प्रेसर के साथ 3 मंजिल पे पहुचाने वाला पंप बताओ कोई, ड्रम में भरा पानी तो कोई भी मोटर खींच लेगा

  • @roopeshpk7871
    @roopeshpk7871 4 ปีที่แล้ว

    Good video.pls tell how many liter water per hour?

  • @rukmaniawasthi
    @rukmaniawasthi ปีที่แล้ว

    Kya cg mini sergeant 2 auto shut down hoti hai?

  • @sanjeev2838
    @sanjeev2838 2 ปีที่แล้ว

    informative, thanks

  • @nitinmarve8699
    @nitinmarve8699 4 ปีที่แล้ว

    Thank you sir for help😊

  • @gopinath-yl3fh
    @gopinath-yl3fh 5 ปีที่แล้ว +1

    Good One

  • @nitinmarve8699
    @nitinmarve8699 4 ปีที่แล้ว

    Kya ye pump ham sarkari nal se pani lene ke liye use Kar sak te he

  • @marotirashtrakut4618
    @marotirashtrakut4618 4 ปีที่แล้ว

    Sir pani jyada niche nahi 7&8 ft hai nikal na hai par kitna ft duri Tak pani flow hota hai

  • @sarveshm6779
    @sarveshm6779 5 ปีที่แล้ว

    nice video, man!!

  • @akulachar1149
    @akulachar1149 3 ปีที่แล้ว

    From 6:50 to till end which music is that, nice to hear

  • @voiceofpartha4963
    @voiceofpartha4963 3 ปีที่แล้ว

    Is pump ko instalation kare ka kharas kitna hota hai pipe milakar

  • @tahmeedkhan9126
    @tahmeedkhan9126 4 ปีที่แล้ว

    Mere ghar se mitha pani matlab nal ki line ki duri 50 feet hai ,waha pani ata hai per mere ghar ke nal me nai aata, yeh pump waha se pani khich sakta hai kya. Pls help

  • @assamesemusicsong8933
    @assamesemusicsong8933 2 ปีที่แล้ว

    It's use for tubel 100 foot please reply sir

  • @jaysarkar851
    @jaysarkar851 3 ปีที่แล้ว

    Bhai mere pass 1hp ki motor single phase ka hai.. Konsa tar use karu... Power 0.75 aur 180-240 voltage ka hai. Please reply

    • @tuhinde698
      @tuhinde698 3 ปีที่แล้ว

      1.5 sqmm acche company ka

    • @jaysarkar851
      @jaysarkar851 3 ปีที่แล้ว

      @@tuhinde698 thanks bhai

    • @jaysarkar851
      @jaysarkar851 3 ปีที่แล้ว

      2sqmm ka lu to kohi problm

    • @tuhinde698
      @tuhinde698 3 ปีที่แล้ว +1

      No problem

  • @m.rrahul8364
    @m.rrahul8364 3 ปีที่แล้ว

    0.5 hp ke motor me kitne mm ka wire use kre

  • @mboowashafiq1496
    @mboowashafiq1496 5 ปีที่แล้ว

    My question is about the discharge head and the rubber seal which must be removed or cut before operation,,,you didn't indicate et well

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว +1

      You have to cut the rubber seal, don't remove it or else water would leak through that joint,
      we weren't able to show that because the shopkeeper did that for us.

    • @mboowashafiq1496
      @mboowashafiq1496 5 ปีที่แล้ว

      Thank alot and please more videos cos I was looking for DC oll the time bt u brought it out just perfectly!!!

  • @AshishKumar-jt6ti
    @AshishKumar-jt6ti 5 ปีที่แล้ว

    Jo pipe apne us dram me dala waisa he pipe Hand pump me upar se dalkar water kich sakte hai kya?

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว

      Chapkal kya chees hain samajh mein nahi aaya?? Hand pump??

    • @AshishKumar-jt6ti
      @AshishKumar-jt6ti 5 ปีที่แล้ว

      @@tuhinde698 yes hand pump.

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว

      Nahi, hand pump se nahi hoga.

  • @chethanrgowdru
    @chethanrgowdru 3 ปีที่แล้ว

    Hello sir load for water ball is not required aaa

  • @ganesha4962
    @ganesha4962 4 ปีที่แล้ว +1

    what ? suction pipe is too long .This type of motor should always keep near water source to increase presssure. suction pipe should not more long any mechanic would suggest you.

  • @bikashjit007
    @bikashjit007 ปีที่แล้ว

    next time use your voice it would be better

  • @ChandraSQLVideos
    @ChandraSQLVideos 4 ปีที่แล้ว

    Good...

  • @kishanvind1425
    @kishanvind1425 2 ปีที่แล้ว

    हमारा टिल्लू पंप बार-बार पानी छोड़ देता है क्या करे

  • @jakiransari6852
    @jakiransari6852 5 ปีที่แล้ว

    Sir mere pass crompton ki haaf ho ki eek tullu pump hai usme dikkat hai ki voltage thodi kam hone pe pani nahi uthati hai aur side me eek usha company ki hai jo utni hi voltage me puri pani presure k sath deti hai.any solution sir please reply

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว

      Pump agar purana ho jaye to new pump ke jaise rate se pani nahi pump karti, uska impeller ghish jata hain. Agar impeller ghish gaya hain to change Karna parta hain.

  • @SantoshKumar-zq6in
    @SantoshKumar-zq6in 4 ปีที่แล้ว

    Good

  • @jamaicanpelpamk1158
    @jamaicanpelpamk1158 5 ปีที่แล้ว

    I have a 1hp pump and it didnt do shit. But I didnt prime anything because I didnt knw what that was for. Do I need to prime it before it works or priming doesnt matter ?

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว

      Yeah you can try priming, our pump does not pump any water without priming.

  • @jontorino4645
    @jontorino4645 5 ปีที่แล้ว

    sir is this possible to pump water this way to a higher altitude like 600 meters away?

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว

      No it can't pump water to 600m altitude

    • @jontorino4645
      @jontorino4645 5 ปีที่แล้ว

      Tuhin De Can you suggest what kind of water pump could pump as far as 600m? Sorry my first question was wrong. I meant 600m far and an altitude at 50m?

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว

      Sorry can't help you in this, You can ask your local pump dealer for suggestions.

  • @aneeshmathai1298
    @aneeshmathai1298 5 ปีที่แล้ว +1

    Brother its work in a 9 meter well??

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว +1

      This pump is rated for an output of 1450 litres per hour from a depth of 6 metres and 450 litres per hour from a depth of 21 metres.
      The max we went so far is 5 metres and we didn't notice any problem.

    • @aneeshmathai1298
      @aneeshmathai1298 5 ปีที่แล้ว +1

      @@tuhinde698 thanks bro

  • @KuldeepSharma-je2tt
    @KuldeepSharma-je2tt 5 ปีที่แล้ว

    Thanks bhi jaan

  • @anupdutta9092
    @anupdutta9092 3 ปีที่แล้ว

    Thanks

  • @debarupasukla3387
    @debarupasukla3387 4 ปีที่แล้ว

    How to know this is coper or silver waring

  • @mechfort2k223
    @mechfort2k223 4 ปีที่แล้ว

    Around total cost how much

  • @renlentlesstourist7574
    @renlentlesstourist7574 5 ปีที่แล้ว

    Will this take the water out of a swimming pool?

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว

      Yes why not, my 750 litre water tank get emptied in under 15 minutes.

    • @renlentlesstourist7574
      @renlentlesstourist7574 5 ปีที่แล้ว

      @@tuhinde698 with a 0.5 pump!
      Perfect, thank you

  • @anukoolmaggera9
    @anukoolmaggera9 5 ปีที่แล้ว

    Sir jo pump ta uper Kala jha kuj ha
    Us ko utar Dana ha ha lai rakhna

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว

      Pump ke discharge side ka kala rubber seal round kar ke kaatna padega pump use karne ke pehle.

  • @ALOKKUMAR-ty6ju
    @ALOKKUMAR-ty6ju 5 ปีที่แล้ว

    Sir ye pump kitne fit tak pani utha sakti h

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว

      Company ke mutabik ye pump 6 meter niche se 1950 litre per hour ke hisab se aur 21 meter niche se 450 litre per hour ke hisab se pani charati hain.
      Aapka water source ka level agar iske beech main hain toh pump aaram se work karega.

  • @ajeetchaurasia3175
    @ajeetchaurasia3175 4 ปีที่แล้ว

    Aur kitane rpm ka h

  • @aishwaryanigam1111
    @aishwaryanigam1111 4 ปีที่แล้ว

    I did the same procedure but still motor has not started , can you tell me anything ?

    • @tuhinde698
      @tuhinde698 4 ปีที่แล้ว

      If humming sound is produced by the pump after powering it then there is a possibility that your pump is jammed, try to manually rotate the pump before switching it on

  • @debarupasukla3387
    @debarupasukla3387 4 ปีที่แล้ว

    Sir this motor waring is coper or silver

  • @shivamvidua4677
    @shivamvidua4677 4 ปีที่แล้ว

    It is 1 hp or 0.5 hp

  • @mramr3853
    @mramr3853 5 ปีที่แล้ว

    Bro I live in second floor and I bought an 1 HP pump
    Tell me where to mount it can I mount it on the second floor itself??

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว +2

      Yes you can mount the pump in second floor but height from the water source should not be greater than 6 meter as shown in 0:59.

    • @debranjanmandal4743
      @debranjanmandal4743 5 หลายเดือนก่อน

      ​@@tuhinde698can 0.5 hp pump upto second floor??

  • @babuganesh2252
    @babuganesh2252 5 ปีที่แล้ว

    Water pump Pani Kaise uthate Hain

  • @sanjitkumarpattanayak3647
    @sanjitkumarpattanayak3647 4 ปีที่แล้ว

    Thank you

  • @m.sowbakyalakshmi6456
    @m.sowbakyalakshmi6456 5 ปีที่แล้ว +1

    Suction la 3/4 podalama

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว

      Can you repeat your question in English or hindi pls??

    • @m.sowbakyalakshmi6456
      @m.sowbakyalakshmi6456 5 ปีที่แล้ว

      @@tuhinde698 input hose 3/4 or 1 size

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว +1

      We used:
      Input pipe - 1 inch
      Output pipe - 3/4th inch
      Input and output head of the pump are of 1 inch, so we installed a reducer to make the output head 3/4th inch.

    • @m.sowbakyalakshmi6456
      @m.sowbakyalakshmi6456 5 ปีที่แล้ว

      @@tuhinde698 thank-you

    • @mechfort2k223
      @mechfort2k223 4 ปีที่แล้ว

      Hindi theriyathu poda 😂😂😂😂

  • @dhurbajyotiborah6713
    @dhurbajyotiborah6713 5 ปีที่แล้ว

    Mere water pump ka upar ke jo nut hai uska washer tut gaya ab kya karna hoga bhai please help

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว

      Washer matlab black color ka jo O ring hain wo agar kharab ho gaya ho to woh alag se pump ke shop mein mil jayega,
      Agar nahi milta hain toh aapko Teflon tape wrap karke nut ko tight karna hoga .

  • @ashirp22
    @ashirp22 5 ปีที่แล้ว

    I DID EVERYTHING AS YOU HAVE SHOWN, BUT PUMP IS NOT DELIVERING WATER. WHAT MAY BE THE PROBLEM PLEASE?
    IT IS CROMPTON 1 HP

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว

      If it is a new pump then you don't have to find the problem, Crompton will do that for you because it's in warranty contact your dealer ASAP.
      If it is old then reprime the pump properly and check for any leak in the suction hose.
      It will take time depending upon the distance and height of your pump from the water source, to avoid damage of the mechanical seal during this initial dry operation priming is a must.

    • @ashirp22
      @ashirp22 5 ปีที่แล้ว

      @@tuhinde698 THANK YOU

  • @girigoku
    @girigoku 4 ปีที่แล้ว

    tq bro

  • @mannysir3342
    @mannysir3342 5 ปีที่แล้ว

    Sir mene yahe moter li hai or sari process ki bt kam nahi kar raha hai kya arthing karni jaruri hai

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว

      Bina earthing ke bhi kaam karega, aap acche se check karlo agar phir bhi nahi chalta toh warranty claim karlo.

    • @mannysir3342
      @mannysir3342 5 ปีที่แล้ว

      Thnks sir mene aaj he ye motter li hai aap ki ye vidio dekhne ke bad....Bt sir khali motter chal rahi hai.. pani kuch bhi nahi khinch raha hai...30 min tak moter chala li

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว

      Aap ne motor ke andar pani dala toh dala hain na??? Jo 3:35 mein dikhaya hua tha.

    • @mannysir3342
      @mannysir3342 5 ปีที่แล้ว

      @@tuhinde698 ha sir sub kuch try kar diya aap ki vidio ko 20-30 bar dekh liya

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว

      Toh phir manufacturing defect ho sakta hain, aap warranty claim karlo.

  • @ranjeetmahto3572
    @ranjeetmahto3572 5 ปีที่แล้ว

    Kitna prise hai sir

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว

      Rs.2450/-, proper gst bill ke sath.

  • @akshaygole9857
    @akshaygole9857 5 ปีที่แล้ว

    same ye hi motor hai hamare pas. earthing nahi diya hai. garam hoke band ho jati hai..

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว

      Aap ekbar pump mein pani daal (priming) ke chalaiye.
      Jab pump properly prime kiya hua nahi rehta hain tab usme suction create nahi ho pata hain, aur pani pump me se nahi flow karne ke karan pump overheat hota hain, jisse mechanical seal damage hone ka khatra rehta hain.
      Hamare pump mein bhi earthing ke liye koi alag se wire diya hua nahi hain, sirf body earthing ke liye ek screw diya hua tha. Hamne usme se earthing wire nikala hain.
      Body earthing ek safety feature hain, Pump ke performance ke sath iska koi lena dena nahi hain.

  • @imdathimdath2399
    @imdathimdath2399 5 ปีที่แล้ว

    I buy new motor not working but I see if video is working thank you

  • @panchanansahu1463
    @panchanansahu1463 3 ปีที่แล้ว

    Cost?

  • @amitkumar2525
    @amitkumar2525 3 ปีที่แล้ว

    Is it still working fine

    • @tuhinde698
      @tuhinde698 3 ปีที่แล้ว

      Yes, still working fine.

    • @amitkumar2525
      @amitkumar2525 3 ปีที่แล้ว

      @@tuhinde698 did you repaired it in past
      which moter would you suggest me to purchase

    • @tuhinde698
      @tuhinde698 3 ปีที่แล้ว

      didn't need repairing of any parts

  • @rkvines9381
    @rkvines9381 3 ปีที่แล้ว

    Binding copper or Aluminum

  • @lachhmansingh6392
    @lachhmansingh6392 4 ปีที่แล้ว

    Mene kl motr li h yr usme bar bar pani dalna prta h 1 gnty bad pani uthati h kya kru

    • @tuhinde698
      @tuhinde698 4 ปีที่แล้ว

      Nrv mein kachra phasa hoga, uskey wajah se nrv close nahi ho raha hain aur pani nikal jaa raha hain suction pipe se. Nrv check karke dekhiye.

    • @lachhmansingh6392
      @lachhmansingh6392 4 ปีที่แล้ว

      @@tuhinde698 nrv kya seal ko nrv bolty h?

  • @abhimanyukumarsingh6352
    @abhimanyukumarsingh6352 4 ปีที่แล้ว

    Pump kaisa tha

  • @ajeetchaurasia3175
    @ajeetchaurasia3175 4 ปีที่แล้ว

    Price kitani h bahi

  • @MURALI230
    @MURALI230 5 ปีที่แล้ว +1

    Mounting screw type Bolo na even i want to mount my motor pump

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว

      screw se nahi nut and bolt se mount kiya hain pump, aap apne requirement ke according size buy kijiye, stainless steel ka bhi nutbolt buy kar sakte hain usme rusting ka problem nahin rehta.

  • @siddappagosabal4140
    @siddappagosabal4140 3 ปีที่แล้ว

    🤝🌹👍

  • @RohitKumar-ro4gv
    @RohitKumar-ro4gv 5 ปีที่แล้ว

    My pump is heating due to high voltage any solution??

    • @kiranpatil3262
      @kiranpatil3262 5 ปีที่แล้ว

      Use stabilizer for pump what hp are you using??

  • @dhurbajyotiborah6713
    @dhurbajyotiborah6713 5 ปีที่แล้ว

    Sir mere 0.5 hp pump pani nahi utha raha hai agar pump me pani dalta hu toh nilkalta hai fir off karne ke baad nahi nikalta hai.
    Please help

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว

      Pump ke input/suction end pe nrv(non returning valve) laga hua hota hain, shayad wo kharab ho gaya hain, wahi chese pani ko pump ke suction side se nikalne se rokti hain. Ekbaar use badalke dekhiye.

    • @dhurbajyotiborah6713
      @dhurbajyotiborah6713 5 ปีที่แล้ว

      @@tuhinde698 nrv matlab jo zameen ke neche rehe wala pipe laga hota hai

    • @dhurbajyotiborah6713
      @dhurbajyotiborah6713 5 ปีที่แล้ว

      @@tuhinde698 nrv matlab foot valve

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว

      Nrv 1:54 mein dikhaya hua hain. Foot valve suction pipe ke end pe lagta hain jo pipe zameen ke niche jata hain use lagane se suction pipe me hamesha pani rehta hain aur foot valve mein bhi nrv lagaya hua hota hain.

  • @waseemsaifi6507
    @waseemsaifi6507 5 ปีที่แล้ว

    Sir ye motor 50 ft tk pani pahuchayegi
    Or quality btaye

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว

      Company kehti hain ye pump 21 metre (65 ft) niche se pani 450 litre per hour ke rate se nikalegi, maine 15 feet tak test kiya hain pani ka flow thoda sa hi ghata tha.
      Quality toh thik hi hain ab tak toh koi major problem nahi aaya.
      Humara pump avg. mein 20-25 min tak chalta hain aur highest 40-45 min chalaya tha koi heating issue nahi aya.
      Bas 1 hi problem hota hain kyunki yeh pump construction purpose ke liye use hota hain isi liye daily basis pe run nahi hota hain, agar 2-3 din bad start karne gaya toh motor jam ho jata hain kyunki humarein borewell ke pani mein iron ka level bohut jyada hain. Aur pump me bhi daily atleast 30 sec tak chalane ke liye instruction diya huan hain.

  • @udaya4123
    @udaya4123 5 ปีที่แล้ว

    Sir this is high speed pump or low speed pump????

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว

      2750 rpm high speed pump

  • @PankajKerketta8
    @PankajKerketta8 3 ปีที่แล้ว

    06:05 Music name please...

    • @MrRs505
      @MrRs505 2 ปีที่แล้ว

      Yeah..I like to know to

  • @HabelHossain
    @HabelHossain 5 หลายเดือนก่อน

    Balsira ata ko videos ho

  • @john4mHyd
    @john4mHyd 4 ปีที่แล้ว

    We need mcb

  • @vivekvv9136
    @vivekvv9136 5 ปีที่แล้ว

    Bhai footwalve water fill nahi he

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว

      Footvalve nahi lagaya hua hain suction pipe pe, pipe ke end pe water filter lagaya hua hain.

  • @shyamalmukherjee9843
    @shyamalmukherjee9843 5 ปีที่แล้ว

    Wire connection are not clear sir. Can you please explain it again?

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว +1

      Pump e generally 2 to tar thake, ekta positive arekta negative, earthing er alada kono tar dewa thake na, kintu earthing na thakle short circuit hole pump dhorle shock khawar bhoy thake.
      Tai amra alada ekta tar body te dewa screw er sathe attach korechi 1:10 ar sei tar er arekta end 3 pin plug er earthing pin er sathe connect korechi(plug er uporer boro pin ta) ar pump er wire gulo(positive + negative) extend kore 3 pin plug e lagiyechi (plug er nicher choto 2 to pin).
      Plug er positive ar negative pin interchangable kintu earthing wire boro pin e tei lagate hbe, jodi earthing wire bhul kore plug er choto pin er sathe connect kora hoy tahole pump touch korlei current lagbe.

    • @shyamalmukherjee9843
      @shyamalmukherjee9843 5 ปีที่แล้ว

      @@tuhinde698 Amar pump a 3 ta wire ase ekta red, ekta black r ekta green. Amar earthing er lega screw nai. Toh ki ami 3 pin top a direct 3 ta tar lagaya dile hwa jaibo along with earthing???

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว +1

      Haan hoye jabe ar green ta holo earthing er tar. Amar pump er body te company er thekei earthing er screw dewa chilo, jehetu apnar pump e earthing er wire agey thekei dewa ache tai company ar alada kore earthing er screw deyni

    • @shyamalmukherjee9843
      @shyamalmukherjee9843 5 ปีที่แล้ว

      @@tuhinde698 Really thank you sir a lot. I found your video to be very informative.

  • @rajalakshmimuniraji6523
    @rajalakshmimuniraji6523 5 ปีที่แล้ว

    price

  • @DevendraSingh-pg3cf
    @DevendraSingh-pg3cf 4 ปีที่แล้ว

    Mujhe is motor ke pipe market main hi nahi mile 😤😤😤😤

  • @mohdrislam1436
    @mohdrislam1436 5 ปีที่แล้ว

    Tillupamp jhute se water kyon deta hai

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว

      Aapka problem samjh mein nahi aaya, phir se batayenge pls.

  • @flp....
    @flp.... 3 ปีที่แล้ว

    Hlo

  • @ManoharKumar-bf2se
    @ManoharKumar-bf2se 5 ปีที่แล้ว

    Is ka body earth samajh nai ay hai ak bar fir sa samajhau

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว

      Earthing wire kisi bhi appliance ke outer body mein current aane se rokti hain, agar short circuit ya loose connection ke wajah se outer metal body ke sath positive wire touch ho jaye toh outer body current ho jayega aur appliance ko pakadne pe humein shock lagega.
      Agar earthing diya huan hain toh wahi current earthing se pass ho jata hain aur humein current nahin lagta.
      Iss pump mein earthing ke liye koi wire alag se diya nahi gaya tha bus ek screw diya tha jisme 3 pin plug ka earthing wire connect kiya hain, usko hi body earthing bolte hain.

  • @sekumezu
    @sekumezu 3 ปีที่แล้ว

    very weak motor

  • @rahulgaming2607
    @rahulgaming2607 5 ปีที่แล้ว

    Tullu pump upar pani thik khinta hai but niche ka pani nahin khinchta hai

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว

      Maine 25 feet tak pani charaya hain, thoda sa hi flow ghata tha, bohut niche se khichne ki liye jyada hp ka pump lagta hain.

  • @ttkshorts5499
    @ttkshorts5499 5 ปีที่แล้ว

    70 fit niche se pani khich lega

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว +1

      Aap ko dusra koi bada pump lena chahiye, ye pump shayad khich dega but pressure bohut kam ho jayega.
      Company ke mutabik 21 meter tak pani utha lega yeh pump lekin tab flow 1950 litre per hour se ghat ke 450 litre per hour ho jayega.

    • @ttkshorts5499
      @ttkshorts5499 5 ปีที่แล้ว

      @@tuhinde698 mera 1.5inch ka hol hai aur water lavel 55 hai to isme koi upay hai sir

  • @lalthafamkimachhangte5780
    @lalthafamkimachhangte5780 5 ปีที่แล้ว

    sir plese can u tell me clearly the wiring process

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว +1

      The water pump came with 2 wires, one is for neutral/ground and another is for positive/ phase you have to connect these two wires to a 3 pin plug/top's positive and negative pins. For earthing purposes the manufacturer didn't provide any wire, so you have to connect a wire to the 3 pin plug's earthing point and connect another end of that wire to the screw situated at the base of the pump 1:10.

    • @lalthafamkimachhangte5780
      @lalthafamkimachhangte5780 5 ปีที่แล้ว

      thank u very much.

    • @lalthafamkimachhangte5780
      @lalthafamkimachhangte5780 5 ปีที่แล้ว

      sir..one more question ,there is no screw at the base of the pump in mine..should i made it by myself or what??

    • @tuhinde698
      @tuhinde698 5 ปีที่แล้ว

      Yes you can connect earthing in any body screw of the pump.

    • @lalthafamkimachhangte5780
      @lalthafamkimachhangte5780 5 ปีที่แล้ว

      okay2 .thnks

  • @AmitKumar-qd5ph
    @AmitKumar-qd5ph 4 ปีที่แล้ว

    Sound of the video is irritating seriously

  • @benemubi
    @benemubi 5 ปีที่แล้ว +1

    Thanks