कितना ही कुछ करो लोड आता हे तो क्रैक आयेगा उससे कुछ फर्क नही पड़ता बनाओ दो क्या 3 मंजिला बनाओ बस बीम कॉलम सेम होना चाहिए और पार्टिशन दीवाल के आस पास होना चाहिए और कुछ नही
Helpful video ❤❤❤ Sir ek question tha Hamara ghr 2 manjila ha aur do column ka distance 17ft ha column size 10*12 aur 4pc 16mm and 4pc 12mm diya ha kya ye thik ha?
Pranam ji, West face 30*40 ke site ke leye rental Ghar banana hi G+3 , G Flore 3 bhk and other floor 1 bhk . Pls suggest plan for pillar and total exp. For G floor.
Bahut TH-cam per se poochha engineer se lekin koi video mein jawab nahin diya aap jarur jawab dena bhai kya comment ke jarie ya video mein jarur bata dena
Sir namskar sir please reply dijiy 2 manjil ghar me kalam size 9/9 ka diya gaya hia jisme 12 mm ka sariya laga hia dono kalam ka distance 11 fit hia kya sahi hia Please Ripley de
Sir jee Niche basement main Sara sariya tata tiskon ka Diya hoon kya uper Jo Ghar banayege usme dusare company ka sariya daal Sakte hai kya aur haa Sare coner main 15×10 ka collum Bana hai jisme 16mm ka 4 pis aur 2 pis 12 mm ka laga hua hai kya yeh sahi hai 🎉🎉🎉
G+2 ghar ke 1 column 4 steel saria 12 mm, distance ek column se dusre column ke tha 12 ft se bana diya ab future main kuch problem hoga kya?Please bataye
सर मैने जमीन मे 10 ईच 10 फिट पीलर दिलवाया जिसमे 4, 12 एमएम का रड और 2, 10 एमएम का लेकिन अब मेरा मन है कि उपर से सभी को 15 इंच उसी लोहे के साथ ले जाये क्या ये सही होगा pls जवाब दिजीये
Sir my coloumn size is 12 X 12" it's distance between coloumn to coloumn is 13' X 15' and rods size are 4 nos of 16mm & 2 nos of 12mm . It's debth is 4' X 4' X 7' . Mixture is 1:2:3 standard level. Just tell me 🙏 is it ok for G+1 storied building? And again on my other building the coloumn size is 12"X 12" it's distance is same 13' X 15' but rods size is 4 nos of 16mm by 4 nos of 12mm , both ring size is 8mm X 6" Centre to centre distance. Debth is 5' X 5' X 7' . Just tell me 🙏 is it ok 👍 for G + 2 storied building. Pls reply I am in confusion 😇
Sir namaste🙏 sir g+1 story house k ly coloum k size 9*9 Rakh k 4 steel (16mm)Dene se,, steel ki Dy k hisab se us me concrete k grip kam ho jayega,,,ek engineersir k video he u tub pe,,, ap k hisab se ky he,, plZ botayega🙏🙏
इंजीनियर साहब ! क्या छत लेंटर की ढलाई में टाप एवं बाटम में लंबाई एवं चौड़ाई में 10 एम एम का सरिया छड़ देना चाहता हूं , ठीक है । मैं छत ढलाई में टाप में 8 एम एम का सरिया छड़ देना नहीं चाहता । कृपया बतायेंगे ।
Sir ek aur chiz Ghar ka external wall pe rustic paint karaye ya koi damprooof karwaye. Please suggest kuki mera engineer rustic ko jyada preference de raha hai. Which is good considering money is not the factor Please reply sir
Very good video, keep doing this kind of videos sir 🙏🙏
10mm ka rode 9x9 ground floor me de sakte hain ki nhi
Very good informative video sir ! Sir if i am making a 2 storey buliding so do I have to provide double mass footing or not ! Thank you !
10×10 Kollam ka difference Kitna hona chahie
Sir bahut acha jankari diya apne
Sir g 1:33 min or 1:37 min pr jo column or wall ka joint h o aligned nhi h matlab jaha join hona chahiye waha nhi h to koe problem nhi hoga.
no
Get specially designed House structural Design at minimum cost .
Feel free to Consult !!
Nice sir big fan
Thank you so much for your support! I really appreciate it.
sir ground floor ki diwaro m halke halke cracks aa rhe hai , kya 1st floor banana sahi rhega? plz reply krna
कितना ही कुछ करो लोड आता हे तो क्रैक आयेगा उससे कुछ फर्क नही पड़ता बनाओ दो क्या 3 मंजिला बनाओ बस बीम कॉलम सेम होना चाहिए और पार्टिशन दीवाल के आस पास होना चाहिए और कुछ नही
Sir ji 25*20 feet ka room hai steel aur column size kya hoga?
Sir septic tank kha pe bnayge ise site pe
sir column ka orientation kaise decide krte hai
Distance kye hisaab se sir
Thanku sir ❤❤
Sir... 9"/9" column m 6pc rode 12 ka laga sakte hai ????
Laga sakte hai ❤
Thank You Bhaiya 🥰🥰🥰
Mera aur ek sawal hai
Agar 9/12 column k liye 4/4 ka footing depth sahi hoga... ????
It's depends u r plot size.9/12 make it than u use 6 rods 12 mm rods
6 rood 12mm ka hi rakhe to koi dikkat hoga sir
कौन से सरिया डाले है आपके घर में जरा वीडियो दिखाना धन्यवाद
10by 18inch ka column banana hai to kitna inch ka ring banega or kitna rod hona chahiye tha
16 mm ka 4 rod and center Mai 12 mm ka 2 piece
Sir chhath dhali ma sariya kitna mm ka Dena thak hai
Helpful video ❤❤❤
Sir ek question tha
Hamara ghr 2 manjila ha aur do column ka distance 17ft ha column size 10*12 aur 4pc 16mm and 4pc 12mm diya ha kya ye thik ha?
Chat ke liye kon sa cement use kare
Bhai sahab main buniyad Ghar ki daal dalva Diya hun to abhi usmein join karna hai kaise tarika Hoga usko batana video
Sir plinth beam ke niche kya hai ground beam??
Sir Ji ... 2 way slab main slope kitna de , or jyadah slope dene ke nuksaan .. kya hai
Sir plot size kya h ??
Sir11x25= 268 sqft k house me with futting total material ka cost kitna aay ga only ground floor .
18 plus wali side column ki chal galat nahi huyi kya?
Sir please help me mera hause bn raha hai but one month se sariya rakha Gaya colam khada tha but barish hone se kya kharab ho Gaya hai
Deepak ji hamara home plan engineer bataa rahe hai ki 3 manzil makan ke liye footing 10mm ka sariya bahut hai.
kya 10mm ka use sahi rahega?
Nahi kam hai 16 ki 4 12 ki 2 totel 6 sariya padegi
Sir 4 manjil ghar ke liye aalam ka size kya hoga
35 by 55 ke hall ke liye kitna size ka coloum hona chahiye
10mm +8mm me kitna flour ho skta h????
Sir ji muze bhi ghar banane ka haiii plan banake doge kya charges rahega wo de dunga
Mp birlla chatek cement 43 grade me kasa ha lanter ke liya Our ser price kitna hai Uttar Pradesh ka
Sir, sirf G+1 ke liye Video bonao. Kyu ki Column Size, Plinth Beam Size, Steel Size Details lena hai
Ok
Sir 3 manjil ka Ghar bana rahe hai to 12mm ka 4 sariya da sakta hai
Nhi bhai
@@Balrajpatel1993 kitna mm ka laga ga
16mm ke 8 sariye
12mm 6 nos
10 inch by 12 inch column size
Bahut acche
Ye to aap ne ground floor ka bataya 1 st floor me or 2nd floor me .... Columns me kitna sariya lagaye
First floor par mujhe column khada karna hai to mujhe column ka vertical sariya cutting size bataiye.
super
Plinth dalne se pehle kya kya savdhani rkhni h
Sir hamne 9*9 ke column mein 12 mm ke 6 piece dale hai sahi hai kya please reply
Pranam ji,
West face 30*40 ke site ke leye rental Ghar banana hi G+3 , G Flore 3 bhk and other floor 1 bhk . Pls suggest plan for pillar and total exp. For G floor.
9 pillar is enough
More better if u make 12 pillars
Sir 16mm 6sarely lagaskati hi ka
Bahut TH-cam per se poochha engineer se lekin koi video mein jawab nahin diya aap jarur jawab dena bhai kya comment ke jarie ya video mein jarur bata dena
oh
2 manjil ke plith bim kitna ke de sir
Sir...21x21 size g+1 ke liye 9x12 pillars kitne lena..?
4 pillars is enough 9/12 .or 9/9 6 pillars need
Sir namskar sir please reply dijiy
2 manjil ghar me kalam size 9/9 ka diya gaya hia jisme 12 mm ka sariya laga hia dono kalam ka distance 11 fit hia kya sahi hia
Please Ripley de
Ek dum perfect hai brother
900" kitna mm column bar 2 manjila
भाई जी कलम एक जैसे ही खड़े करना चाहिए कि अलग-अलग
2700 sqft house me Kitna kharch aayega
45 lakh only ground floor
G+1 home construction ke liye, 15*10 coloum size main 4 pis 16mm steel use kar sakte hain keya?
Yes
12' by 12' size
Sir ji,2 floor banana hai to 4 rod 12 ke aur 2 rod 10 ke use karna sahi hai kya😊ya 6 rod 12 ke hi waparna chahiye, please bataiye❤❤
Brother depend on u r pillar size.if u r pillar is 9/15 than this condition 12 ke 4 PCs aur 10 ke 2 piece
beem bananake lebar ret je hai
10 mm ka sariya use hua h ground floor Me sb jagah
Next floor bna skta h ?
No
Sir jee Niche basement main Sara sariya tata tiskon ka Diya hoon kya uper Jo Ghar banayege usme dusare company ka sariya daal Sakte hai kya aur haa Sare coner main 15×10 ka collum Bana hai jisme 16mm ka 4 pis aur 2 pis 12 mm ka laga hua hai kya yeh sahi hai 🎉🎉🎉
Yes
16 fite/30 fite me kitna piller lagega
Feet likhne phele shiko bhai
यदि 18 फीट column की दूरी है तो बीच में तो column दे सकते थे।
G+2 ghar ke 1 column 4 steel saria 12 mm, distance ek column se dusre column ke tha 12 ft se bana diya ab future main kuch problem hoga kya?Please bataye
mujhe reply chaiye bhaiya
12 mm 4 number rod and 9*9 inch column, can I make G+1 pls reply
Hn ho jaega❤❤❤
It's good not bad u can
Ye Foundation plan G+2 ka hai ya G+1
Please can you share us depth of column. How many feet have to dig for base of pillars
4/4
4.5/4.5 more better
Sir jis tarah turki main bhokamp main building gir gayi to mujhe, lagta hai kalam ka size 18, 18 hona chahiye
No
Column to column distance g+2 rod used 16mm 6 pcs 12mm 2pcs ..colomn size 12×14 is it good
2 manjil yaani G+1 ya G+2
G+1
Sir 11*50house price
Hi 🤗🤗
Ek sawal tha jo 4 se 5 Manjil hoti hai agar uska column 14 inch k honge or diwar 9 Inch ki toh latak beam 9 inch se jada kaise de ?
16 mm ka 8no's sariya hona chahiye aur column size (9"x15")
Bhim ka size aur rod ka size kya rahega sir ji
What could be the size of columns and steel bar for g+3
सर घर का साईज कितना फिट बाय कितना है बताना चाईय सर हम समज सके सर
Room size 13*13 , for g+1 , column size 9*12 . Steel used 16mm 4no,12mm 2no , is it correct?
sir ji namaskar 25*50 ka ek naksha dijiye
4 pc12mm rod, column size 8×8 inch,column distance maximum 10.5 ft, can i make G+1storey?
12 mm ka 9 inch coloum me 6 saria dal sakte hai ki nahi
Daal saketay hai brother more if not no problem
Ager pillars size 9/9 hoga tow 4 hi kafiii hai ya enough hai 12 mm ka steel rod
More better
Kalam my 20 mm ka sariy Diya hu 15 9 ka kalm sir
36 foot chaudai 26 foot lambai teen bedroom kitchen latrine bathroom gadi parking
सर मैने जमीन मे 10 ईच 10 फिट पीलर दिलवाया जिसमे 4, 12 एमएम का रड और 2, 10 एमएम का लेकिन अब मेरा मन है कि उपर से सभी को 15 इंच उसी लोहे के साथ ले जाये क्या ये सही होगा pls जवाब दिजीये
Sir my coloumn size is 12 X 12" it's distance between coloumn to coloumn is 13' X 15' and rods size are 4 nos of 16mm & 2 nos of 12mm . It's debth is 4' X 4' X 7' . Mixture is 1:2:3 standard level. Just tell me 🙏 is it ok for G+1 storied building?
And again on my other building the coloumn size is 12"X 12" it's distance is same 13' X 15' but rods size is 4 nos of 16mm by 4 nos of 12mm , both ring size is 8mm X 6" Centre to centre distance. Debth is 5' X 5' X 7' . Just tell me 🙏 is it ok 👍 for G + 2 storied building. Pls reply I am in confusion 😇
Okay👌 and 12 x 12' column is okay for g+2 building bt if possible use 14 x 9 inch column
Formula dijiye sir
सर स्टील कैसे कैलकुलेट करतें है कॉलम या बीम में
Video coming soon
Calculation bataye
Sir namaste🙏 sir g+1 story house k ly coloum k size 9*9 Rakh k 4 steel (16mm)Dene se,, steel ki Dy k hisab se us me concrete k grip kam ho jayega,,,ek engineersir k video he u tub pe,,, ap k hisab se ky he,, plZ botayega🙏🙏
no issue
इंजीनियर साहब ! क्या छत लेंटर की ढलाई में टाप एवं बाटम में लंबाई एवं चौड़ाई में 10 एम एम का सरिया छड़ देना चाहता हूं , ठीक है । मैं छत ढलाई में टाप में 8 एम एम का सरिया छड़ देना नहीं चाहता । कृपया बतायेंगे ।
ok de sakte hai
यह मकान कभी 3 मंजिल का बनायेगा तो क्या होगा। क्या तीसरी मजिंल नही बना पायेगा।
मिस्री ने 6 सरिया 12 ऍम ऍम की और 9*9 इंच के कॉलम डाले हैं, क्या मैं 2 डबल स्टोरीज़ (जी+1) बना सकता हूँ? कृपया उत्तर दें।
सर ऐसे हि विडियो हमने बनाया सायद आपको पसन्द आए
Chajja me kitne mm ka sariya Dena chahiye
10mm
Ok
Sir hamara column ka layout aisa hai for 3 storey building:
C1: 10*15( 4 - 16MM + 4 - 12MM)
C2: 10*15( 6 - 16MM + 2 - 12MM)
C3: 10*18( 6 - 16MM + 4 - 12MM)
Sir theek hai na.
❤ that's also good 👍👍👍
Sir ek aur chiz
Ghar ka external wall pe rustic paint karaye ya koi damprooof karwaye. Please suggest kuki mera engineer rustic ko jyada preference de raha hai.
Which is good considering money is not the factor
Please reply sir
14 fhit my hai to
20x35 ka naksha batao
ok sar
12mm ka
6 sariya hia
Sir koi contact no. H to send kijiye
16 mm 8p dea hu humlog,
Pankaj tripathi 😂
Abe kya kya bol raha hai khud hi samjha Raha hai😂
12😂😊❤
huu
Contact no dije
Dear sir
Best for public 😮
Please contact number dijiye
ok
Sir apka number plz
sir aapka phone number dena
plan banwana h
M9523101369
@@CivilEngineerDeepakKumar
Jayakrushnabehera
@@CivilEngineerDeepakKumar0:01