powMR 60A ✓ REPAIR ✓ RÉPARATION

แชร์
ฝัง
  • เผยแพร่เมื่อ 27 ส.ค. 2024
  • 48622698/41008637

ความคิดเห็น • 26

  • @jojodalentour7546
    @jojodalentour7546 7 หลายเดือนก่อน

    Eskize m wi. Ou di tout tenten sof reparasyon an ou pa fè nan videyo sa a . M pa tande kote ou anonse dezyèm videyo a. Ta dwe gen metòd wi.

  • @jimmysaintil3800
    @jimmysaintil3800 2 ปีที่แล้ว

    Bonjou.
    Silvouplè ban m dat n'ap gen fòmasyon sou enstalasyon pano solèy epi di m sa w panse sou pwodui sa: ondilatè solèy (pwodui enphase).

  • @colojames7186
    @colojames7186 2 ปีที่แล้ว

    Pou kou elektwonik lan , ou t gen yon kit ou tap vann pou nou t k fè pratik Dim nn lap tou ladanl?

  • @evenspointdujour8306
    @evenspointdujour8306 2 ปีที่แล้ว

    Indutance ou we yo ak condensateur sa yo yo jwe rol lissage pour inductance lan et filtrage pou condensateur an

  • @enfopeyim7430
    @enfopeyim7430 2 ปีที่แล้ว

    Konbyen tan yon regulatè kap fe ap fonksyone sal poko deranje

  • @jimmysaintil3800
    @jimmysaintil3800 2 ปีที่แล้ว

    Konbyen janvye kou a ap fèt?

  • @bosjosephacaau8054
    @bosjosephacaau8054 2 ปีที่แล้ว

    Slt slpv knbyen HT you regilatèr knsa slvp

  • @bosjosephacaau8054
    @bosjosephacaau8054 2 ปีที่แล้ว

    Mw ta renmenw fè you video su li pum ta knn knbyen kòb mw ka HT tel

  • @boluwatifeoladeinde-gh7li
    @boluwatifeoladeinde-gh7li ปีที่แล้ว

    Identify d13 component pls

    • @ClaytechPro
      @ClaytechPro  ปีที่แล้ว

      What u need exactly?. D13

  • @aceblack9077
    @aceblack9077 ปีที่แล้ว

    Ki kote ou ta konseye on moun al repare on Regulateur konsa

    • @ClaytechPro
      @ClaytechPro  ปีที่แล้ว

      Ki sal genyen

    • @aceblack9077
      @aceblack9077 ปีที่แล้ว

      @@ClaytechPro
      Li bay ecran blue selman
      Li pa mache, anyen

  • @joabjoseph7153
    @joabjoseph7153 ปีที่แล้ว

    M besoin yon flex powmr ht wi bro svp fem jwenn li bro?

  • @PVflying
    @PVflying ปีที่แล้ว

    Hi! I’m sorry I don’t know French, I hope it’s ok to write in English 👍 These PowMr 60A controllers have a software fault where they drop into PWM mode (mode 7 on the display) and you need to switch off the PV input and reconnect it to get back to mode 4 (MPPT). Did anyone find a solution? I’m wondering about adding an automatic resetting circuit which disconnects the PV input via a mosfet SSR but I don’t know where to find the control signal from. I need a signal which goes high or goes low when the unit changes to mode 7 🤔

    • @ClaytechPro
      @ClaytechPro  ปีที่แล้ว

      Send me pic when display mode 7 wa.me/message/CRO4UGRFPS3KI1

    • @stokeeic
      @stokeeic ปีที่แล้ว

      I have also the problem with my device. What do you have make to solve the problem?

    • @PVflying
      @PVflying ปีที่แล้ว +1

      @@stokeeic I didn’t fix it yet, but I noticed that when it happens the voltage at PV input drops to around 40V (normally it is 50-60V). If I leave it alone then it drops further during the next hours,m down to 24V. I’m thinking I will create a small circuit which switches PV input off (via SSR solid state relay) if PV voltage is 40V or below. But the circuit must switch off only briefly (for a few seconds) then reconnect.

    • @stokeeic
      @stokeeic ปีที่แล้ว

      @@PVflying I've been thinking something similar circuit. Unfortunately, a short break is not always enough. Sometimes the input capacitor remains charged and the charge controller continues to measure a voltage. Then I have to interrupt the performance for about 1 minute. I will work with an optocoupler on the gate to pull it to source from the input Mosfet in the mppt charger. Unfortunately, you can tell the poor quality of theUnfortunately, you can tell the poor quality of the. I

    • @PVflying
      @PVflying ปีที่แล้ว

      @@stokeeic thank you for the information. There is another TH-cam video you should look at, I’ll give you the name instead of a link because I don’t know if a link will work. It’s called “MakeSkyBlue 40A solar MPPT charge controller, auto reset I had to build” by user “Opera”. My experience has been that my PowMr unit will always reset with a break of a few seconds in PV input and my PV panels are already wired via a SSR which my BMS uses to switch charging on and off, so I just need a reliable way to sense the lockup condition and switch off my SSR for a few seconds. Maybe your idea of picking up the input from the PowMr PWM circuit will work.

  • @noeljustin300
    @noeljustin300 ปีที่แล้ว

    Se 2 tranjustor 4diod

  • @mikekevenchavannes1739
    @mikekevenchavannes1739 ปีที่แล้ว

    Svp mwen paka gen numéro whatsapp poum explikew yon problem mwen jwen o nivo de Regulatè pam lan