Capacitor Kvar to Farad & Microfarad | KVAR to uf conversion formula | electrical calculations| kvar
ฝัง
- เผยแพร่เมื่อ 3 ก.ย. 2019
- capacitor kvar to farad & microfarad - KVAR to uf conversion formula - electrical calculations - electrical dost
Hi
I am Aayush Sharma Welcome to our youtube channel Electrical Dost.
About this video-
Dosto Aaj Ki Is Video Me Maine Aapko how to convert kvar to farad and microfarad Batane Ki Koshish Ki Hai Or Kuchh electrical tips jaise how to change capacitor value KVAR to uf, types of value of capacitors, MFD full form, electrical industries work and Electrical interview questions answers Share Kiya Hai Ummeed Hai Aapko Ye Video Bahut Pasand Aayegi (hindi)
Thank you so much..........
..................................................................................................................
Our some other videos -
mcb and mccb difference
• mcb and mccb differenc...
..
..
mcb vs rccb difference
• mcb vs rccb difference...
..
..
Dol starter power and control.
• Dol starter in hindi d...
..
..
how to read motor nameplate.
• motor nameplate in hin...
..
..
cable size calculation
• Cable size calculation...
..................................................................................................................
Queries Solved:
1) KVAR to Microfarad
2) kvar to mfd
3) kvar mean in electrical
4) kvar to uf conversion formula
5) kvar to farad formula
6) capacitor kvar to farad
7) electrical video in hindi
Email - Aayushsharma0713@gmail.com
#Capacitor #KVAR #mfd #farad
#formula #electrical #kvar
Don't forget to SUBSCRIBE electrical dost for more Trusted electrical videos. - วิทยาศาสตร์และเทคโนโลยี
Zabardast explain kiye ho Bhai math bhi samjha Diya
Pehla video dekha hu Bhai TH-cam pad aisa!
thanx to help in every topic. i hope you can always help in next topic.
very comfrtable answer
Hi, I like your lecture. Thanks
Very good.
Sir ji good
good video
❤️❤️❤️
I've seen in star delta starter connection star take more current than delta is it possible in any case then explained please
Thanks
Is the capacitor bank calculated for individual motor or total connected load?..in the sld is it shown for individual motor or entire connected load
Efficiency
I ask about PF & efficiency ..why pf is decreasing with increase in efficiency. Infact it should increase..pls reply
Sorry...but explanation is wrong...because micro fared doesn't equal to 10^6.....it's actually equal to 10^ - 6
Isiliye 10^6 se multiply kiya gya h...microfarade me convrt krne k liye...
Yes bro
Sir mera question ye h ki 10 hp 3 phase motor jiska PF 0.5 h ,ke liye kitne KVAR ka capacitor lenge ye kitne uf ka capacitor lenge.
Aap ke video sahi h par mujhe ye doubt hai ki KVAR ki value pe capacitor puchase karna hai ki uf ki video par.?
Please prepare a video about synchronize
Sir only farad ki value karke bhi batao
he is explain little bit wrong but calculation is right . As we divide and multiply with that quantity in which we are converting so ,by dividing it it 1x10^-6 will be 1x10^6 if it goes in numerator side.
Sir micro faraid to 55.5 aaye faraid kitne aaye ye bhi bataiye
Sir If the Capacitor bank is using for 3phase loads(motors) then the value of 'V' will be 415 ? Please clear.
Yeah
Vfd par video banawo dost
Hey, yeh calculation mein V agar 415 V hote toh kya hoga yeh 1-P ke liye hai please ans soon 10 raysto -6
Damn i wish i could understand what you are saying
Accha three phase capacitor bank hai 5 kvar ki uska uf nikal ne k liye jo voltage square se divide karenge woh 230 volt le na 415 volt le?
415
Bhai plz kaho. 1.549kvar ka kya MFD banta hai...
Sir 1kvar =16.44uf, that why mentioned in 440 voltage in formula, that is right answer sir....
How this formula came please explain
3 phase capacitor ka MFD calculate karne ke liye voltage √3 lenge kya ? Sir please bataye
No
Nano & pico fd ka formula bhi dijiye sir
Calculation = 2*3.14*50*240*240=18086400
Right
2*3.14*240*240=18,086,400
Sir company me jo capacitor bank lagane ke fayde or Na lagane se kya problem ho saktihai
Sir i m also in electrical fild
Aap agar capacitor bank lagaoge to apka power factor acha ho jayega
Or current ki jo need he vo kam ayegi
Or electrical bill bhi kam ayega thoda
Or agar na lagaya to power factor jitna down hoga utna current badhega
Or bill jyada ayega or jyada current ki vajah se wire bhi thoda garam hoga
Aap apni need ke mutabik calculation krke capacitor bank ya fir only solo capacitor laga skte he
How to find earthing cable
2×3.143×50×240×240 = 18103680...
Bhai agar 3 phase supply hoga to voltage ke place par kya likhenge.aapne to 240 likh diya.lekin wo aaya kaha se ye nahi explain kiye
Ki 1 phase me kaise calculate kare aur 3 phase me kaise kare
पूरा बेस से बताइये
3ph ka hi hai na
Kvar see amp kese nikale
aap nea elctrical mea BE keya hea
2×3.14×50×240×240= 18086400
Not 18103680
Sir capacitor ki value me MFD ka matlav kya h
Mfd means micro farade vo capacitor ki capacity dikhati he
For example home use vale fan me 2.50 mfd ka capacitor hota he.
3.3 uf ketla kvr
1.5lakh milega
240 v kyu
415 v karana chahiye
Sir from which numbers you have divided 1000000 those are wrong your numbers will be 18086400
10-⁶
why you are confusing the viewers, 1 Farad is equal to 10 rest to the power minus 10 but what you say? And second, your value is not correct according to our calculation.3rd --- write fist kvar =----------------, 4th --, tell to viewers microfarad is equal to------------------ etc., please don't the mixture of words.
Sir aapne 10 ka kuch kiya nahi
Formula ni matlab chahiye tha
Answer hai 0•0016778*10^-8
Sir thik se समझ मे नही आया
Sir, aap to pehele ye har 10 sec me vdo re-start jaisa hona bandh kijiye.
Calculation galat ha sir upon vali
Bhai calculation galat he tumhari
Calculation wrong hai
Uf ki jagah mf Kyo nahi likha rahta hai