How to wire Field Zone / Module Interface in Addressable FACP & Conventional Initiating Devices

แชร์
ฝัง
  • เผยแพร่เมื่อ 19 ธ.ค. 2024

ความคิดเห็น • 22

  • @batangrilesvlogs67
    @batangrilesvlogs67 2 ปีที่แล้ว +3

    Napakalaking tulong Ng pagbibigay kaalaman nyo po sir... Thank you po

  • @arifgani5326
    @arifgani5326 6 หลายเดือนก่อน +1

    Good pare

  • @aminmanagili6885
    @aminmanagili6885 3 หลายเดือนก่อน +1

    Good day sir,pwede mo ba ako gawan ng video kung paano mag interface ang fdas panel at earthquake device control panel.

  • @edinaguilar12
    @edinaguilar12 2 ปีที่แล้ว +2

    Thanks for sharing ur video sebding support here

  • @JohnmarkfuentesFuentes
    @JohnmarkfuentesFuentes ปีที่แล้ว +1

    Sir good morning po may tuturial po. Kayo paano magkabit ng flowswitch supervisory swict sama na yong damper motor sir salamat po and god blessed po sir

    • @RACkabayanTECH
      @RACkabayanTECH  ปีที่แล้ว +1

      Meron po check mo nalang sa mga videos ko😊

  • @mrdiaz1985
    @mrdiaz1985 ปีที่แล้ว +1

    Required po ba gumamit talaga ng zone module pag floor to floor? Ndi po ba pwedeng riser ng lang ng wire papunta sa upper floors? Ano po pinaka advantage niya sa sytem?

    • @RACkabayanTECH
      @RACkabayanTECH  ปีที่แล้ว

      Depende po sa system na gagamitin at taas ng building na pag iinstallan........... sana nakatulong😊

  • @brianemaamo8554
    @brianemaamo8554 2 ปีที่แล้ว +3

    tanung ko lng po sir,, required po ba tlga ang EXTRENAL POWER SUPPLY na 24V at saan po bang location naka.install yan,,,, di po ba ang SLC ay may 24V na din na supply....,,salamat po and godbless..

    • @RACkabayanTECH
      @RACkabayanTECH  2 ปีที่แล้ว

      Hi partner, regarding sa tanong mo🙂 yes partner need po ang external power supply na 24volts hindi po enough ang 24volts sa SLC na i power lahat ng initiating devices, kaya need ang external power supply...magkatabi lang po sa FACP depende po sa installation🙂 sana nakatulong👍

  • @JohnmarkfuentesFuentes
    @JohnmarkfuentesFuentes ปีที่แล้ว +1

    Good morning sir pwd po wlang 24vdc.mag aaditoional nlng ng slc at yong sa damper motor po sir paano po yong connection.salamat po sir and god blessed po

    • @RACkabayanTECH
      @RACkabayanTECH  ปีที่แล้ว

      Panoorin mo nalang partner ang video tutorial ko nyan kung mag wiring nyan sana nakatulong😊

  • @junmaleek265
    @junmaleek265 2 ปีที่แล้ว +1

    Sir, Wla po ako makkita yong main control panel connection. Kung paano yong signing nya gling sa mga module?

    • @RACkabayanTECH
      @RACkabayanTECH  2 ปีที่แล้ว +1

      Sir, bawat module po ay may corresponding address na naka configure sa FACP... Halimbawa sir yung first floor area! May mga nka install na initiating devices dyan.........isa sa mga yan ang mag activate yung device na nag activate magbabato ng signal doon sa module.......so yung module may address po yan! Yan po ang makikita sa FACP mo doon mo ma identify kung saan galing yung alarm makikita sa display ng FACP mo! Sana nkatulong partner! Ulitin mo lang sa panonood partner😊✌️

  • @arnaldosolon1824
    @arnaldosolon1824 5 หลายเดือนก่อน +1

    Bakit kailangan ng end of line resistor ang addresabale.sir

    • @RACkabayanTECH
      @RACkabayanTECH  5 หลายเดือนก่อน

      Walang EOL
      sa addressable FDAS system sir ang EOL ay para lang po sa conventional FDAS system salamat

  • @MusicLover-oj4yu
    @MusicLover-oj4yu ปีที่แล้ว +1

    Sir pwede po ba addressable device ang ilagay jan

  • @novievillegas6867
    @novievillegas6867 10 หลายเดือนก่อน

    sir, di ba parehas lang ang connection ng 24V at saka FZ module? ang difference lang sa drawing nyo, yung 24V circuit nya ay kinonekta ito sa wire, pero pwede naman itong idirect sa terminal block. then yung input ng FZ module, direkta na ito sa terminal block
    tama ba ako sir?