ZONES IN BATHROOMS - BS7671 WIRING REGULATIONS AMENDMENT 2 - CONFORMING TO PART P & THE REGULATIONS

แชร์
ฝัง
  • เผยแพร่เมื่อ 8 ม.ค. 2025

ความคิดเห็น •

  • @basejumper01
    @basejumper01 7 หลายเดือนก่อน +1

    Yet another excellent video from Learn Electrics which has helped clarify in further details the content of BS7671 wiring regs. Thank you for this upload it has been really helpful for my 18th edition studying

  • @martinburgess2322
    @martinburgess2322 ปีที่แล้ว +4

    Appreciate your content. Well explained as always👌👍😎

  • @olusegunakande9508
    @olusegunakande9508 ปีที่แล้ว +1

    The is excellently well clarified & will be really helpful to me in my coming exam

    • @learnelectrics4402
      @learnelectrics4402  ปีที่แล้ว

      All the best with the exam. yes, they love to put catch you out questions in exams. Good luck, its a great trade to be in.

  • @hussmortada
    @hussmortada ปีที่แล้ว

    Thank you so much, I learnt a few new things today as is the usual with your videos. Well done!

    • @learnelectrics4402
      @learnelectrics4402  ปีที่แล้ว

      Great to hear and next weeks video is on Shower zones. Thanks for watching, appreciated. Dave.

  • @greatrixbrad
    @greatrixbrad ปีที่แล้ว +1

    Excellent video, as ever!
    I’m curious how the zones would be measured in an L-shaped bathroom with a shower/bath at one end? I guess the 2.5m would go diagonally to the corner, and then follow along the edge of the wall? I’ve seen an example where following the wall would allow a socket 2.5m from the shower but if the 2.5m can pass directly through the wall (shortest path, regardless of obstacle) the distance would be less than 2.5m. I guess the former would be more correct, not least because in this circumstance a socket would be totally out of sight/inaccessible from the shower because it is around a corner….

    • @learnelectrics4402
      @learnelectrics4402  ปีที่แล้ว

      Think of it this way. Everywhere a 0.6m piece of string can reach and still be in contact with the bathtub is zone 2.
      And everywhere a 2.5m string can reach and still touch the bath is the outside zone area.
      The string can go round corners, round partitions, anywhere you want. As long as it maintains contact with the bath. So you could end up with a funny looking shape for the zones as you suggest.
      Hope this helps, we have a video on shower zones coming up soon and it is covered in that.

  • @praveensundaram9636
    @praveensundaram9636 3 หลายเดือนก่อน

    Thanks, your video really useful ❤

  • @user-qi8tv2sj4m
    @user-qi8tv2sj4m 11 หลายเดือนก่อน

    Really good video I learnt a lot thanks

  • @Electric-First
    @Electric-First ปีที่แล้ว +1

    Great as always 👏

  • @ElectricEssenceLtd
    @ElectricEssenceLtd ปีที่แล้ว

    Great Video as always

    • @learnelectrics4402
      @learnelectrics4402  ปีที่แล้ว

      Thanks again, your comments are always appreciated. Dave.

  • @Smtvideo
    @Smtvideo ปีที่แล้ว

    Hi, thank you for the videos they are really helpful. I am training to become a qualify electrician and they have been helping me throughout. I have one question most of your videos are giving page numbers on the blue book. If you can make a vid with the latest number page that will be very helpful ( Like the most important pages) Thank you again

    • @learnelectrics4402
      @learnelectrics4402  ปีที่แล้ว +1

      If it has a blue book on the starting slide for the video, it relates to the blue book.
      If it has a brown book on the video then page numbers are for the brown book.
      Go to LearnElectrics.com and put Amendment 2 into the search box and you will get a list of links direct to the Brown book, including questions and answers for the exam. Good luck. Dave.

    • @Smtvideo
      @Smtvideo ปีที่แล้ว

      @@learnelectrics4402 Thank you so much, you have been very helpful

  • @highgatehandyman6479
    @highgatehandyman6479 ปีที่แล้ว

    Excellent content as usual.
    Got a question re low voltage SElV 'circuits' .. if a shaver socket is supplied by 240v . But is in zone two. And is ipx4. Is it allowed ? Even though just behind it is 240v? Not all switches and sockets are fitted well to the wall and look like water could get behind..

    • @learnelectrics4402
      @learnelectrics4402  ปีที่แล้ว

      If it is the BS EN 61558 then yes. It is 240V in and 240V out, but the output is electrically separated. Its not SELV, its SLV.

  • @bil-k6h
    @bil-k6h หลายเดือนก่อน

    Can you have a light switch with ipx4 rating in the outside the zones area?

    • @learnelectrics4402
      @learnelectrics4402  หลายเดือนก่อน

      Yes you can. Thanks for watching.

    • @bil-k6h
      @bil-k6h หลายเดือนก่อน

      @@learnelectrics4402 Does the regulations require it to be ip rated? Or is a normal switch fine as long as its outside of zone 2. Or as a minimum the ip20 for water ingress protection?

  • @SimplyFootball1
    @SimplyFootball1 ปีที่แล้ว

    Really love your content. How do you create your art work?

    • @learnelectrics4402
      @learnelectrics4402  ปีที่แล้ว

      Thanks for the compliments, appreciated. How? Lots of hard work and many years of finding the methods. thanks for watching.

  • @onefortheroad1
    @onefortheroad1 3 หลายเดือนก่อน

    Can a shower wall isolator switch be installed in the outside the zones area?

    • @learnelectrics4402
      @learnelectrics4402  3 หลายเดือนก่อน

      Absolutely yes, best place for it.

    • @onefortheroad1
      @onefortheroad1 3 หลายเดือนก่อน

      @@learnelectrics4402 thanks, you said in once if your earlier videos that it needs to be installed outside the bathroom so I wasn’t sure

  • @jco92
    @jco92 ปีที่แล้ว +1

    Light switches in a bathroom are OK as long as they are 0.6m from zone 1?

    • @learnelectrics4402
      @learnelectrics4402  ปีที่แล้ว +1

      Ceiling pull switches or SELV

    • @jco92
      @jco92 ปีที่แล้ว +1

      Isn't that outside of zones though, making a light switch acceptable?

  • @vasilios.v
    @vasilios.v ปีที่แล้ว

    so just to clarify electric towel rails can installed on zone 1 & 2 ?

    • @learnelectrics4402
      @learnelectrics4402  ปีที่แล้ว +1

      Take a look at On Site Guide, Table 8.1, p104. If appropriate IP rating for the zone, then yes.

    • @vasilios.v
      @vasilios.v ปีที่แล้ว

      @@learnelectrics4402 thank you so much for the reply. I really appreciate it

  • @testingtechnicians6751
    @testingtechnicians6751 ปีที่แล้ว

    Another new topic is covered 🎉

  • @ParamjeetPoet
    @ParamjeetPoet 6 หลายเดือนก่อน

    Is any reg for loo/toilet wc only /sink and toilet only

    • @learnelectrics4402
      @learnelectrics4402  5 หลายเดือนก่อน +1

      Does it have a bath or a shower? That is the only question. No bath, no shower, then the zones do not apply. Hope this helps, Dave.

    • @ParamjeetPoet
      @ParamjeetPoet 5 หลายเดือนก่อน

      @@learnelectrics4402 no bath, no shower

  • @AviKhali
    @AviKhali 3 หลายเดือนก่อน

    Does the toilet itself come under zone 0?

    • @learnelectrics4402
      @learnelectrics4402  3 หลายเดือนก่อน

      If the toilet is in the zones measured from the bathtub then it comes under whichever zone it is in.
      Everything is measured from the bathtub or shower basin.

  • @abrahamuk7403
    @abrahamuk7403 ปีที่แล้ว

    Thank you

  • @brianhewitt8618
    @brianhewitt8618 ปีที่แล้ว

    👌

  • @fatihdemir9609
    @fatihdemir9609 2 หลายเดือนก่อน

    Excellent video! Passed my 18th edition watched all your videos top man👍🫡

    • @learnelectrics4402
      @learnelectrics4402  2 หลายเดือนก่อน +1

      Nice work, well done. It's a good trade to be in, taken me around the world working. Thanks for watching. More to come.