how to fix homage inverter fault 8 in urdu हिंदी | ups fault 8 | ups error 8

แชร์
ฝัง
  • เผยแพร่เมื่อ 30 ก.ย. 2024
  • get free help
    Join FB group and post your question i am also in group
    / 171260460137503
    paid help is also available on request
    in this video i will tell you
    how to repair fix homage ups inverter fault 8 in urdu hindi
    how to repair fix homage inverter tron due error 8 in urdu hindi
    how to repair fix fault 8 in homage inverter tron due
    have a look www.electronicabc.com
    How to repair fix dead ups or inverter any brand in urdu hindi
    • How to repair dead hom...
    How To Repair Fix inverter ups Fault 0 solution
    • How To Repair inverter...

ความคิดเห็น • 91

  • @asifinam272
    @asifinam272 2 ปีที่แล้ว

    Salam Bhai
    Mary pass homage neon1203 USP fault 8 day Raha hy. DC booster sec 300 v Bana Raha hy chr FETs theek Han if 3843 bhi change kr deya hy 10 ohm or 0.2 ohm resistance bhi theek hn aas pass ki resistors bhi theek hn koi component faulty Nahi mill Raha. Ap rahnumai farmayan.
    Is ups ma pahlay fault 07 Aya tha. Opto 817 Ka problem tha change kr deya ab fault 7 Nahi hy per fault 8 a Raha hy or ups 295 v out pa show karta hy.

  • @rahulpatelgujratahmedabad3497
    @rahulpatelgujratahmedabad3497 2 ปีที่แล้ว

    Good tiching karte hai 👍👌👍👍👌👌👍👍👌

  • @saniqazi5123
    @saniqazi5123 2 ปีที่แล้ว

    Bhai HomAge ka stabilizer ha uski ic kharab ha uske liye b koi video banaye

  • @faridunniaz6960
    @faridunniaz6960 3 ปีที่แล้ว

    sir mere pas chaina ka invarex 3+3 ka ups he jo on ni horaha he ac supply do to on ni hota par ac to ac nikalta he .na ac se or na dc se on hota he keya masala he

  • @ahameedqureshi7655
    @ahameedqureshi7655 2 ปีที่แล้ว

    Salam alekum rehmatollah e barkatolah sir app ki works shop kis jagha h karachi m

  • @TanveerAhmad-pd9ni
    @TanveerAhmad-pd9ni 2 ปีที่แล้ว

    Sir g jo part r value or tr npn pnp ha

  • @UmairKhan-it1op
    @UmairKhan-it1op 3 ปีที่แล้ว

    salam sir mere same ya he model ha lakin is ka fan har waqt chalta raheta ha

  • @irfanali5218
    @irfanali5218 7 หลายเดือนก่อน

    good jobe

  • @abdullahzeeshan4242
    @abdullahzeeshan4242 2 ปีที่แล้ว

    Fabulous

  • @kaptaanawan4073
    @kaptaanawan4073 7 หลายเดือนก่อน

    R 89 ki value kya hy

  • @jamilahmed1661
    @jamilahmed1661 6 ปีที่แล้ว

    Meri pas homage ups hai jo kharaab ho gaya hai mechinic ki pass le kar gaya lekin us ko samajh nahi aa raha .plz apna adrees den tu main aap ki pass bhijwadon .

    • @electronicabc
      @electronicabc  6 ปีที่แล้ว

      To reach at our shop via Google Maps click on link below
      goo.gl/maps/LEcsi7dzYuy
      shop 34 rabia duplex
      mosamiyat chowk university road karachi

  • @rahulpatelgujratahmedabad3497
    @rahulpatelgujratahmedabad3497 ปีที่แล้ว

    👍👍👌👍

  • @muhmadmuzamil2613
    @muhmadmuzamil2613 5 ปีที่แล้ว

    Imran ups rpering center jatoi

  • @ahmedali-fu3hj
    @ahmedali-fu3hj 5 ปีที่แล้ว

    Sir Mary pass homeage ups hay us mian 400 wate say ziada lode nahin uthata kis area ka fult hay check keron

  • @muhammadlatif4786
    @muhammadlatif4786 3 ปีที่แล้ว

    Hello sir,
    I have Homage UPS Tron UNO (HTU-1205). It has recently developed error A56. I am using Tubular Battery (Phoenix TX 1400) with it. I did clean the fan and whole UPS but still the problem persists. TH-cam videos refer to fix this issue by changing the battery settings to 10.5 under btu. But unfortunately I couldn't find this setting in HTU-1205 model. Would appreciate your kind support. Thank you.

  • @mamir2424
    @mamir2424 5 ปีที่แล้ว

    Aslam alaikum
    Bhai jo bary risister lgey Han in ki valu Kia ha

  • @FawadKhan-yy2zy
    @FawadKhan-yy2zy 6 ปีที่แล้ว

    سلام بھائی جان۔
    میرے انورٹر میں مسئلہ یہ ہے کہ جب ہم اس سے بھی لیتے ہیں تو یہ چارج نہیں ہوتا یعنی چارجنگ رک جاتا ہے۔ یہ سولر سسٹم پر بھی اور بجلی سے بھی۔
    پہلے ایسا تھا کہ یہ آؤٹ پٹ اور ان پٹ دونوں چلتے تھے یعنی بیک وقت ہم ان سے بجلی لیتے بھی تھے اور یہ چارج بھی ہوتا رہتا تھا لیکن اب ایسا نہیں ہوتا۔ پیارے بھائی زرہ مجھے بھی گائیڈ کر دے کہ یہ مسئلہ حل ہو جائے۔ یہ بیک وقت چارج بھی ہوتا رہے اور ہم بجلی بھی ان سے استعمال کرتے رہیں۔
    شکریہ

    • @electronicabc
      @electronicabc  6 ปีที่แล้ว

      پیارے بھایی میں آپ کی بات نہیں سمجھ سکا مھربانی فرما کر تھوڑا وظاحت کر دیں اور ups بنانے والی کمپنی کا نام اور ماڈل نمبر بھی بتا دیں

  • @bluffmaster1894
    @bluffmaster1894 4 ปีที่แล้ว

    I have axiom 3002 can i send it to you for repairing
    it is dead and every body refused.

  • @muhammadayaz6536
    @muhammadayaz6536 6 ปีที่แล้ว +1

    Zabar 10 bhai jan

  • @amanalikhiyani2893
    @amanalikhiyani2893 6 ปีที่แล้ว +1

    V. Good

  • @ihsanwazir
    @ihsanwazir 6 ปีที่แล้ว

    salam,
    i am a ups mechanic, and currently i come across a ups which do not charge the battery. it gives output but do not charge the battery. so i want to ask that what would be the fault that i should mend. or simply tell me which tiny electrical component is to be repaired or changed.\\
    if you have an idea about this then kindly reply

    • @electronicabc
      @electronicabc  6 ปีที่แล้ว

      Please post your question with make and model number with pcb pictures in this group
      facebook.com/groups/171260460137503/
      We will try to gues

  • @aneeskhan4897
    @aneeskhan4897 6 ปีที่แล้ว

    Hi
    Mary pass homage hexa 2004 ups hai jo fault 8 show kar raha hai mainy , r89, r91, d22 change Kia ore baqee open check b keya magar pir b 300 voltage show karky fault 8 mai Chala jata hai please koee sallah dai shukrya

    • @electronicabc
      @electronicabc  6 ปีที่แล้ว

      Fault 8 ka matlab hai k ups k output voltage regulate nahin ho rahe output k voltage ko charging section regulate karta hai aap charging section ka mosfet + uc3843 check kren

  • @bigbos2678
    @bigbos2678 5 ปีที่แล้ว

    Sir mere pas APT INVEREX XP 10+10 24V hia mien ny Transistors check kiya thek hien bazahir kuch short nazar nahi aa raha per ups short bata raha hai.ap batoa kia karun?

  • @dilshadseher4455
    @dilshadseher4455 6 ปีที่แล้ว

    Bhai falt 7 kis cheez ka he or plz apna number b day

    • @electronicabc
      @electronicabc  6 ปีที่แล้ว

      Ups konsa hai aur model number kia hai ?

    • @electronicabc
      @electronicabc  6 ปีที่แล้ว

      Axpert ups fault codes
      www.electronicabc.com/tutorials/ups-inverter/axpert-ups-inverter-fault-codes/

    • @electronicabc
      @electronicabc  6 ปีที่แล้ว

      See Invermax ups fault codes
      www.electronicabc.com/tutorials/ups-inverter/invermax-ups-inverter-fault-codes/

    • @electronicabc
      @electronicabc  6 ปีที่แล้ว

      See Homage ups fault codes
      www.electronicabc.com/tutorials/ups-inverter/homage-ups-fault-codes/

  • @ssharpeyes
    @ssharpeyes 4 ปีที่แล้ว

    very help full error 3 aya inverter mai .... toh sab FET change krdia hain ... abhi on toh ho rha hai ... but bakup pr nahe jaa rha hai ... kindly help

  • @ImranAli-np9ol
    @ImranAli-np9ol 5 ปีที่แล้ว

    Bhai apki shop kaha ha mujy inverter repair karwana ha plz shop adrees plz

  • @ZaighamAliAyub
    @ZaighamAliAyub 6 ปีที่แล้ว

    Bhai mainay sb cheezain change ki hai par ab volt 310 de rha hai error 8 ata hai model hexa 2004 hai

  • @SajidKhan-wo6wg
    @SajidKhan-wo6wg 6 ปีที่แล้ว

    Ap NY muje lahore ka numb nahi deya

  • @funtime2700
    @funtime2700 5 ปีที่แล้ว

    inverter mai error 8 ata hai hai phir off jar kenin karo tu theek ho jata hai phir pora din chalta

  • @kamranlahoretv4162
    @kamranlahoretv4162 3 ปีที่แล้ว

    Nice video. Good information

  • @RashidKhan-my4jg
    @RashidKhan-my4jg 5 ปีที่แล้ว

    Excellent video you are genius sir and make more videos about different faults of homage ups.thanks

  • @imadali3343
    @imadali3343 6 ปีที่แล้ว +1

    Ups part input mode and backp mode

    • @electronicabc
      @electronicabc  6 ปีที่แล้ว +1

      Please wait i will tell everything . Stay with us

  • @MuhammadRizwan-jw4vp
    @MuhammadRizwan-jw4vp 6 ปีที่แล้ว

    sir bht hi zuberdust ap realy apny profession m bht alla ormahir hn very thnkfull to u this very usefull information sirrrr

  • @alisufyan869
    @alisufyan869 6 ปีที่แล้ว

    sir inwarx ka purana model hai bekap par output voltage zada derha hai sab smd thek hai MOSFET bhi thek hai 2 MOSFET 740 tabdil kiye the ups output voltage 245 de raha hai ab

    • @electronicabc
      @electronicabc  6 ปีที่แล้ว +1

      Check charging mosfet + uc3843 + replace 499k resistors near bridge diode

  • @jamilahmed1661
    @jamilahmed1661 6 ปีที่แล้ว

    Shabbir bhai buhut shukria .

  • @jamilahmed1661
    @jamilahmed1661 6 ปีที่แล้ว

    Bhai apna contact no plz .

  • @asadkhan-gh1vn
    @asadkhan-gh1vn 6 ปีที่แล้ว

    falt 0.1 ka bata do meherbani kr k bhai je ...............

  • @imtiazahmad8541
    @imtiazahmad8541 5 ปีที่แล้ว

    Sir cyber power inverter Mn fault E09 ko kaisay Tk krtay hein

  • @sultanakhtar9833
    @sultanakhtar9833 6 ปีที่แล้ว

    Lony ka fault num 5 and 1 btaden plz

  • @fastcom2858
    @fastcom2858 4 ปีที่แล้ว

    Great sir .thanks

  • @shafiqkhan7186
    @shafiqkhan7186 5 ปีที่แล้ว

    Good video very nice

  • @hafizahmad5036
    @hafizahmad5036 5 ปีที่แล้ว

    ASSALAMO ALAIKUM TO ALL FRIEND

  • @rdxkhan6008
    @rdxkhan6008 5 ปีที่แล้ว

    Sir apki website open nahi hoti

  • @intelligentlife7790
    @intelligentlife7790 6 ปีที่แล้ว

    Inverex xp solor pro 2800 06 error

  • @asadkhan-gh1vn
    @asadkhan-gh1vn 6 ปีที่แล้ว

    inverter on ho k 200v sy 400v tk jata hy or falt 01 deta hy

    • @electronicabc
      @electronicabc  6 ปีที่แล้ว

      Inverter ka charging section kaam nahin kar raha ho ga is liye high volt aate hon ge charging section chek kren

  • @sindhelectronics5286
    @sindhelectronics5286 6 ปีที่แล้ว

    good video sir

  • @nayyerabbss5088
    @nayyerabbss5088 6 ปีที่แล้ว +1

    good video

  • @sharjrrlkhan9802
    @sharjrrlkhan9802 5 ปีที่แล้ว

    Salam sir
    Ek problem hey us k solution k lea aap ki help chahta hon.
    Hum electronics ki appliances use krtay hn or inhen us supply say powerup karna lazim hota hey jis k earth or neutral k dirmian 0.7volt say ziadah potential na ho.
    Lekn ab jesay hi UPS backup pr jata hey to earth neutral k darmian voltage 90 tk punch jatay hn.
    Ups 6kva
    Company : APC

  • @Meharjiii
    @Meharjiii 6 ปีที่แล้ว

    Bhai ups F2 de ra hy problem btaeye

  • @muhammadRizwan-vm4dg
    @muhammadRizwan-vm4dg 6 ปีที่แล้ว

    or agr ya sb kuch dekne ke bad bi agr foult8 show kare phr or agr ups ke time ok ho jata hai or charging ke time wapas transters jala deta ha to kia karna chahiye

    • @electronicabc
      @electronicabc  6 ปีที่แล้ว

      Jaise hi time mila main ups tutorial pe videos bnaon ga jis se aap khud expert ho jayen ge

  • @ZaighamAliAyub
    @ZaighamAliAyub 6 ปีที่แล้ว

    Hai g change kia

  • @Bahria-Times
    @Bahria-Times 6 ปีที่แล้ว

    Error 9 ko kese fix kareinge, ac output nahi phaik raha inerex ka hai

    • @electronicabc
      @electronicabc  6 ปีที่แล้ว +1

      Chek irf740 and irf3205 and sg3525 and smd resostors near irf740

  • @ZaighamAliAyub
    @ZaighamAliAyub 6 ปีที่แล้ว

    bhai jan 0 fault ata hai homage 1000 matrix main mainay 4 fet change b kiye hain ab output daita hai par sath e bnd ho jata hai aur 0 fault de daita hai

    • @electronicabc
      @electronicabc  6 ปีที่แล้ว

      Without load output volt chek kar k btayen meter k wire plut kar lgain phir voltage chek kren donon rukh pe voltage chek kar k btayen

    • @ZaighamAliAyub
      @ZaighamAliAyub 6 ปีที่แล้ว

      bhai jan 300 tak jatay hain aur sath e bnd ho jata hai

    • @electronicabc
      @electronicabc  6 ปีที่แล้ว

      Charging section main fault hai. Charging section charging k ilawa AVR ka kaam bhr karta hai. Try to replace uc3843 . Kia charging theek karta hai ?

    • @ZaighamAliAyub
      @ZaighamAliAyub 6 ปีที่แล้ว

      g main pe ok hai mainay invertor walli side se uc 3845 change kia pr koi farq ni pra

    • @ZaighamAliAyub
      @ZaighamAliAyub 6 ปีที่แล้ว

      us ki chargin walli sidde pe b uc 3845 laga hai main wo b change kr k daikhta hn

  • @asadkhan-gh1vn
    @asadkhan-gh1vn 6 ปีที่แล้ว

    me ny 3843 ic bhi chang kr di hy phir bhi high voltage falt nhi ja raha pless bta do

    • @electronicabc
      @electronicabc  6 ปีที่แล้ว

      Charging section he output volt control karta hai charging section ko achi tarah chek kro smd transistor mosfet resistors waghera

    • @asadkhan-gh1vn
      @asadkhan-gh1vn 6 ปีที่แล้ว

      R 163 01C 10K resistors 20k show kr rhi thi ka3525 ky pas wo me ny chang ke or voltage normal ho gay ab set ok ho gya hy aap ki video bhot achi hain jwab deny ka skrya sar or zyada video banaen

    • @asadkhan-gh1vn
      @asadkhan-gh1vn 6 ปีที่แล้ว

      Thank you

  • @adilkhan-yk5fm
    @adilkhan-yk5fm 6 ปีที่แล้ว

    Bhai mera ncr company is ups hy wo flat ke light or beep dyraha hy mujy uska masla or so ke shop kahan hy he he batayen meny thek karwana hy plz

  • @rizwananwar4082
    @rizwananwar4082 6 ปีที่แล้ว

    Bahi infini 3 kw ki Repiaring pa koi Video banain

  • @muhammadmunir9637
    @muhammadmunir9637 6 ปีที่แล้ว

    good job i am munir abbasi