- 210
- 197 870
360° Engineer
เข้าร่วมเมื่อ 24 ก.ย. 2021
Highly motivated and progressive Engineer with a long-standing background in the field of industrial Engineering.
Throughout the course of my career, I have perfected my system installation, operation, maintenance, testing and diagnostics and troubleshooting abilities in Engineering. I am a capable and consistent problem-solver skilled at prioritizing and managing projects with proficiency. In my role, I contributed leadership, critical thinking, and electrical system modification toward team efforts and business improvements. I am progressive minded and in tune with new developments in my field. I have proven to be effective and collaborative with strong problem-solving talents. I enjoy sharing my skills in videos
Throughout the course of my career, I have perfected my system installation, operation, maintenance, testing and diagnostics and troubleshooting abilities in Engineering. I am a capable and consistent problem-solver skilled at prioritizing and managing projects with proficiency. In my role, I contributed leadership, critical thinking, and electrical system modification toward team efforts and business improvements. I am progressive minded and in tune with new developments in my field. I have proven to be effective and collaborative with strong problem-solving talents. I enjoy sharing my skills in videos
Rotor Angle Stability in Power System || Steady State & Transient Rotor Angle Stability
Rotor Angle Stability in Power System || Steady State Rotor Angle Stability || Small Disturbance Rotor Angle Stability || Transient Rotor Angle Stability || Large Disturbance Rotor Angle Stability
มุมมอง: 130
วีดีโอ
Power System Stability | Rotor Angle Stability -Steady State&Transient | Voltage&Frequency Stability
มุมมอง 18221 ชั่วโมงที่ผ่านมา
Power System Stability || Rotor Angle Stability - Steady State & Transient || Voltage Stability || Frequency Stability
Protection for Grid Parallel Operation || Trip or Island for Grid Disturbances/Faults/Contingencies
มุมมอง 12614 วันที่ผ่านมา
Protection for Grid Parallel Operation in Industries (Part-1) || Trip or Island for Faults, Grid Disturbances, In-House Contingencies
Handling of Nickel Cadmium (Ni-Cd) batteries || Do's, Don'ts & Precautions while working on Battery
มุมมอง 812 หลายเดือนก่อน
Handling of Nickel Cadmium (Ni-Cd) batteries || Do's, Don'ts & Precautions while working on Ni-Cd Battery
Operation & Maintenance of Nickel Cadmium (Ni-Cd) batteries || Faults and Their Remedial Actions
มุมมอง 1232 หลายเดือนก่อน
Operation & Maintenance of Nickel Cadmium (Ni-Cd) batteries || Factors which Affect Performance Ni-Cd batteries|| Probable Faults and Their Remedial Actions || Maintenance Schedule of Ni-Cd Battery Bank
Commissioning of Nickel Cadmium (Ni-Cd) batteries | Filled and charged/discharged,Dry and discharged
มุมมอง 1313 หลายเดือนก่อน
Commissioning of Nickel Cadmium (Ni-Cd) batteries || Commissioning of Filled and charged condition Ni-Cd batteries || Commissioning of Filled and discharged condition Ni-Cd batteries || Commissioning of Dry and discharged condition Ni-Cd batteries
Installation of Nickel Cadmium (Ni-Cd) batteries | Filled and charged/discharged, Dry and discharged
มุมมอง 1283 หลายเดือนก่อน
Installation of Nickel Cadmium (Ni-Cd) batteries || Installation of Filled and charged condition Ni-Cd batteries || Installation of Filled and discharged condition Ni-Cd batteries || Installation of Dry and discharged condition Ni-Cd batteries
Nickel-Cadmium (Ni-Cd) Battery Basics | H,M & L type | Pocket (PP), Sintered (SP) & Fibre Plate (FP)
มุมมอง 2724 หลายเดือนก่อน
Nickel-Cadmium (Ni-Cd) Battery Basics || H, M & L type || Pocket (PP), Sintered (SP) & Fibre Plate (FP)
What is Biological Oxygen Demand (BOD) in Water ? | Importance of BOD in Effluent & Sewage Treatment
มุมมอง 976 หลายเดือนก่อน
What is Biological Oxygen Demand (BOD) in Water ? | Importance of BOD in Effluent & Sewage Treatment Plant || Measurement of BOD
What is Dissolved Oxygen (DO) in Water ? || Factors Effecting Oxygen Saturation Point of Water
มุมมอง 926 หลายเดือนก่อน
What is Dissolved Oxygen (DO) in Water ? || Importance of Dissolved Oxygen (DO) in Water || Factors Effecting Oxygen Saturation Point of Water || How to increase dissolved oxygen in water ?
What is Oxidation Reduction Potential (ORP) ? || Effect of pH on ORP || Where and How ORP used for?
มุมมอง 1147 หลายเดือนก่อน
What is Oxidation Reduction Potential (ORP) ? || What is Oxidation & Reduction Reactions ? || Potential due to Half reactions (Oxidation or Reduction) || Effect of pH on ORP || Where and How ORP used for?
What is CAT (Category) rating of a test instrument? | CAT I, CAT II, CAT III, CAT IV Ratings of Inst
มุมมอง 2227 หลายเดือนก่อน
What is CAT (Category) rating of a test instrument ? || CAT I, CAT II, CAT III, CAT IV Ratings of Instruments
Generator Protection Relay - Micom P343 | Metering, Configuration, Protection Settings,Event&Records
มุมมอง 1.9K7 หลายเดือนก่อน
Generator Protection Relay - Micom P343 || How to Scroll or View Various Features - Metering, Configuration, Protection Settings, View Events, Fault Records & Disturbance Recorder, Display, Digital Input & Output Labels
Chloride Industrial Systems (CIS) Make UPS | Metering, Control of Rectifier, Inverter, Bypass,Faults
มุมมอง 2987 หลายเดือนก่อน
Chloride Industrial Systems (CIS) Make UPS || Metering, Control of Rectifier, Inverter, Bypass, Faults, Warnings || Reset of Faults || Boost Operation
Siemens Protection Relay - SIPROTEC 7SJ | Metering,Configuration, Protection Settings, Event&Records
มุมมอง 1.4K8 หลายเดือนก่อน
Siemens Protection Relay - SIPROTEC 7SJ || Annunciation, Measurement, Control, Settings, Test/Diagnosis || How to Scroll or View Various Features - Metering, Configuration, Protection Settings, View Events & Records, Display
Feeder Protection Relay - Siemens 7SR | Metering, Configuration, Protection Settings, Event &Records
มุมมอง 9338 หลายเดือนก่อน
Feeder Protection Relay - Siemens 7SR | Metering, Configuration, Protection Settings, Event &Records
Feeder Protection Relay - Micom P143 || Metering, Configuration, Protection Settings, Event &Records
มุมมอง 5858 หลายเดือนก่อน
Feeder Protection Relay - Micom P143 || Metering, Configuration, Protection Settings, Event &Records
Gutor Make UPS || Control of Rectifier, Inverter, Bypass & Boost Operation, Metering, Alarms, Faults
มุมมอง 1.2K8 หลายเดือนก่อน
Gutor Make UPS || Control of Rectifier, Inverter, Bypass & Boost Operation, Metering, Alarms, Faults
Easergy P3U Protection Relay Communication, Logic & Matrix - Schneider Make || Esetup Easergy Pro
มุมมอง 1.5K8 หลายเดือนก่อน
Easergy P3U Protection Relay Communication, Logic & Matrix - Schneider Make || Esetup Easergy Pro
Esergy P3U Protection Relay - Schneider Make || Protection Settings, Control, Test -Function, BI, BO
มุมมอง 4179 หลายเดือนก่อน
Esergy P3U Protection Relay - Schneider Make || Protection Settings, Control, Test -Function, BI, BO
Sensitive Earth Fault (SEF) Protection of Transformer || Standby Earth Fault (SEF) Protection
มุมมอง 2.9K9 หลายเดือนก่อน
Sensitive Earth Fault (SEF) Protection of Transformer || Standby Earth Fault (SEF) Protection
Transformer Restricted Earth Fault (REF) Protection Stability Checking & Sensitivity Testing
มุมมอง 1.7K9 หลายเดือนก่อน
Transformer Restricted Earth Fault (REF) Protection Stability Checking & Sensitivity Testing
Restricted Earth Fault (REF) Protection of Transformer || REF Protection Philosophy & Relay Settings
มุมมอง 1.1K9 หลายเดือนก่อน
Restricted Earth Fault (REF) Protection of Transformer || REF Protection Philosophy & Relay Settings
Transformer Differential (Biased) Protection Stability Checking & Sensitivity Testing
มุมมอง 1.7K10 หลายเดือนก่อน
Transformer Differential (Biased) Protection Stability Checking & Sensitivity Testing
Transformer Differential Protection || Biased Differential Protection Settings & Philosophy
มุมมอง 7K10 หลายเดือนก่อน
Transformer Differential Protection || Biased Differential Protection Settings & Philosophy
CT Connections to Relay || Current Flow in CT Secondary & Relay Circuit During Normal & Fault cases
มุมมอง 67810 หลายเดือนก่อน
CT Connections to Relay || Current Flow in CT Secondary & Relay Circuit During Normal & Fault cases
What is Power Factor (PF) || What is Active & Reactive Power ? || Significance in Electrical Systems
มุมมอง 27610 หลายเดือนก่อน
What is Power Factor (PF) || What is Active & Reactive Power ? || Significance in Electrical Systems
Substation in Industries Consists of ? | LIB,HT/MCC/PCC/PMCC/EPCC/EPMCC Panels, MLDB/ ELDB/ LDB etc.
มุมมอง 30511 หลายเดือนก่อน
Substation in Industries Consists of ? | LIB,HT/MCC/PCC/PMCC/EPCC/EPMCC Panels, MLDB/ ELDB/ LDB etc.
What is Substation? | Why Substation required in Industries? | Compare with your home Electrical sys
มุมมอง 15811 หลายเดือนก่อน
What is Substation? | Why Substation required in Industries? | Compare with your home Electrical sys
Soft Starter for AC motor || Different Types of Soft Starters and its applications in Industries
มุมมอง 245ปีที่แล้ว
Soft Starter for AC motor || Different Types of Soft Starters and its applications in Industries
Sir , Can you prepare a video regarding the BHEL make DAVR micro terminal operation and setting
Sir Please prepare a video regarding the Micro terminal operation and how to do settings from it.
Awesome Sir❤
Generator synchronizing check protection video
Please send sir manual and drawing.pdf file
Your topic selection is excellent . Pls upload such types of videos in near future 👍
Thank you for the appreciation!
Kindly make a video series on how to study Load flow study, Short circuit study , Electromagnetic transients study etc .
Very good sir
Many many thanks 😊
Appreciating your efforts. Highly useful contents. Thank you...360
Many many thanks 🙏
What is the power swing in the Grid side ?
Why three winding transformer used for Grid ?
For Zero sequence current
Super 💯❤❤❤
Sir please tell me how to check igbt driver pulse
Network status b red colour come problem kya
Sir alarm kaise hatega
I am very thankful to you sir for creating such knowledgeable videos with such dedication....
Many many thanks, glad you are finding the content helpful!
Hi. I am Vietnamese. I am currently working with electrical equipment. I am trying to access this device but without success. I hope you can help.
Thank you sir...very useful information.
Pdf milega kya sir iska
Sir in differential protection we always use star point towards object?
Kindly make a video on Synchronous motor and excitation panel schematic drawing
Kindly make a video on Low tension panel sliding contact details
Also kindly make a video on Synchronous motor and excitation panel schematic and power wiring diagram and tells detail about excitation panels
Kindly make different types of soft starter videos
Kindly make a video on Battery bank load test
Kindly make a video on how to identify DC earth fault in a substation with complete standard operating procedure. Your explanation skills are excellent
NI-CD battery load test video banaye sir
can trans in English please
Why battery capacity reduce when battery temperature less than 20 C
Is there any fault coordination between fuse and semiconducting power divices ?
Battery load test video
If ripple Current more as per rating then what steps we have to follow for reduction of ripple current or voltage Also what factors effect more ripple current
Some time we have seen that ACO healthy led lamp glow but when we checked auto changeover then auto change over not happen . What’s the issue ?
May be not taken all the conditions for healthiness of Auto changeover (Conditions mentioned in the video)
@@360Engineer01 ok
In our power plant 3 GT of 20 MW , 3 TG of 10 MW and 1 TG of 15 MW is there . During normal operation 3 GT And 1 TG of 15 MW in running in Synchronised condition to cater total load of 60 MW . If system frequency is 51.3 Hz and we want to decrease this frequency at 50.2 hz . Then how can we proceed? Kindly explain
Normally if GT's selected in droop mode, reduce MW of single or multiple GT's to bring the desired frequency. Note: Power System topology (SLD) to be checked. If there is Tie Transformer b/w GTG & STG, Ensure no overload on Tie T/F.
@@360Engineer01 in droop mode if we reduce MW then frequency will increase . In our plant 2 tie transformer dither of 20 MVA between GT and TPS . How tie transformer will get over load during frequency decrease?
Emotron vsm vfd error a27 kaise thik hogi
Veriable torque kya hota hai sir
❤❤❤
Sir best content kindly share your contact number for communication.we have static Excitation max similar kind of system.
However, there are many reasons to not get selected, but the above reason is predominant.
Sir, Could you make detailed informative videos for VFD & its associated Parameter Setting, Connection Schemes, Trouble shooting, Maintenance, etc... Bcz , in most of interviews that i faced - the demand is for VFD, IM-T/F Protection, Maintenance, IMCCs & other panel's Automation. That's why A candidate who has 2-2.5 years of experience lags to get job in company
Could you make detailed video playlist for VFD-Operation, Setting, Trouble shooting, Maintenance.
Excellent
Thank you so much 😀
Sir, Please explain how to work STTPMSU FUNCTION?
Thank you 🙏 for such valuable content.
Good presentation
Hiii sir, Kindly give your contact detail. like...mobile number, Micro Teams id
Battery impedance test video
How to decide which capacity of fuse we will use in Type 2 coordination scheme . Suppose we have 30kw motor fed from Switch fuse unit . How much rating of fuse we will select . Kindly explain
Already explained in following video, please do watch th-cam.com/video/QwN2_CJ_8uc/w-d-xo.html
Excellent
Thank you so much 😀
Excellent