Alex The Handyman
Alex The Handyman
  • 218
  • 1 841 538

วีดีโอ

HOW TO REPLACE A. GE MICROWAVE CONTOL BOARD. JNM3163RJ5SS
มุมมอง 90วันที่ผ่านมา
In this video I will take you step by step how to replace a GE microwave control board.
GET RID OF YOUR KITCHEN RANGE HOOD EXHAUST. INSTALL A MICRO HOOD INSTEAD.
มุมมอง 613หลายเดือนก่อน
In this video I will take you step by step how to remove your exhaust range hood and install a micro hood instead.
HOW TO REPLACE GALVANIZED PIPES AND VALVES UNDER THE SINK
มุมมอง 836หลายเดือนก่อน
In this video I will show you how to replace and remove galvanized pipes under the sink. www.homedepot.com/p/BrassCraft-1-2-in-FIP-Inlet-x-1-2-in-Comp-Outlet-1-4-Turn-Angle-Valve-G2R37X-C1/205214422?g_store=&source=shoppingads&locale=en-US&pla&mtc=SHOPPING-BF-APT-GGL-Multi-Multi-NA-NA-NA-PLALIA-NA-PRS-NA-NA-NBR-NA-PRO-NEW-RES_CONST&cm_mmc=SHOPPING-BF-APT-GGL-Multi-Multi-NA-NA-NA-PLALIA-NA-PRS-N...
HOW TO INSTALL FENCE POSTS WITH A POST DIGGER. 'WE USED FOAM INSTEAD OF CONCRETE.
มุมมอง 1772 หลายเดือนก่อน
In this video I will show you how to install fence posts step by step using a post digger. We used foam instead of concrete. WORK SMARTER NOT HARDER. www.homedepot.com/p/Sika-2-lb-PostFix-Fence-Post-Mix-Mix-In-The-Bag-Expanding-Foam-for-Supporting-Non-Structural-Posts-Mailbox-Sign-7116170/300934597?source=shoppingads&locale=en-US&pla&mtc=SHOPPING-RM-RMP-GGL-D22-Multi-NA-SIKA-NA-PMAX-NA-NA-INV00...
HOW TO INSTALL A RECEPTACLE (OUTLET) UNDER THE KITHEN COUNTER TOP FOR A DISH WASHER/COOK TOP/GD
มุมมอง 2302 หลายเดือนก่อน
In this video I will take you step by step how to install a receptacle or outlet for a Dish washer, cook top, or garbage disposal.
HOW TO CHARGE AN AC SYSTEM WITH REFRIGERANT WITH A RECOVERY MACHINE (BY WEIGHT)
มุมมอง 5212 หลายเดือนก่อน
In this video I will take you step by step how to charge and ac system with refrigerant with a recovery machine. ( by weight)
HOW TO RECOVER REFRIGERANT "FASTER"FROM AN AC SYSTEM
มุมมอง 4542 หลายเดือนก่อน
In this video I will take you step by step how to recover refrigerant faster from an AC system. www.supplyhouse.com/Appion-MGAVCT-1-4-Valve-Core-Removal-Tool?Shopping_Neutral_New_users&gad_source=1&gclid=CjwKCAjw9IayBhBJEiwAVuc3fqH0EoehvMYnkDl3om4abW_spf_BoCAssv4r1Dk76I5dtKkQIW5bChoCUkAQAvD_BwE trutechtools.com/MGABAS?gad_source=1&gclid=CjwKCAjw9IayBhBJEiwAVuc3fuB7DPV7gVjJ3mJKCgdrL3sfLprLbgNX7u...
WHAT TO DO WHEN YOU HAVE LONGER AIR CONDITIONER LINE SET.
มุมมอง 4922 หลายเดือนก่อน
In this video I will show you step by step what to do when you have longer line sets on an air conditioner.
HOW TO LEAK TEST AN AC SYSTEM WITH NITROGEN PRESSURE
มุมมอง 4.9K3 หลายเดือนก่อน
In this video I will show you step by step how to leak test an AC system with nitrogen pressure. www.amazon.com/Regulator-Connection-Heavy-Duty-Self-reseating-NAKAO/dp/B08SJBVS45/ref=asc_df_B08SJBVS45/?tag=hyprod-20&linkCode=df0&hvadid=507714472492&hvpos=&hvnetw=g&hvrand=8837598213913646555&hvpone=&hvptwo=&hvqmt=&hvdev=c&hvdvcmdl=&hvlocint=&hvlocphy=9021511&hvtargid=pla-1295324872303&psc=1&mcid...
HOW TO RECOVER REFRIGERANT FROM AN AC UNIT.
มุมมอง 5653 หลายเดือนก่อน
In this video I will show you step by step how to properly recover refrigerant from an AC unit. This method is the most used and the slowest. www.amazon.com/Robinair-RG3-Twin-Cylinder-Portable-Refrigerant/dp/B00NMOYPVG/ref=sxin_16_pa_sp_search_thematic_sspa?content-id=amzn1.sym.15bb851a-7b12-4426-b7a1-b84d50f201d9:amzn1.sym.15bb851a-7b12-4426-b7a1-b84d50f201d9&crid=FPOHCNANXNQC&cv_ct_cx=robinai...
HOW TO USE A HVAC CHEATER CORD
มุมมอง 1K3 หลายเดือนก่อน
SAFETY DISCLAIMER I JUST WANT TO LET YOU KNOW THAT DOING THIS IS NOT SAFE. IT ENERGIZES EVERYTHING INCLUDING THE REFRIGERANT LINES AND MIGHT BE DANGEROUS FOR YOU OR ANY BODY WORKING ALONG THIS UNIT. THIS IS A NASATY TRICK OF THE TRADE SO IF YOU CAN .... DONT DO IT. IF YOU ARE GOING TO DO IT ANY WAYS TAKE ALL THE PRECAUTIONS. IF THERE IS WATER PRESENT OR RAINING DO NOT DO IT. In this video I wil...
HOW TO SNAKE STEP BY STEP A 2 IN DRAIN WITH A RIDGID K400 3/8 SNAKE AUGER
มุมมอง 5593 หลายเดือนก่อน
HOW TO SNAKE STEP BY STEP A 2 IN DRAIN WITH A RIDGID K400 3/8 SNAKE AUGER
HOW TO REPLACE A FRIGIDAIRE MICROWAVE/HOOD FUSE
มุมมอง 6633 หลายเดือนก่อน
HOW TO REPLACE A FRIGIDAIRE MICROWAVE/HOOD FUSE
GE DISH WASHER BEEPING 3 TIMES. DOOR LOCK AND CONTROL BOARD REPLACED.
มุมมอง 6184 หลายเดือนก่อน
GE DISH WASHER BEEPING 3 TIMES. DOOR LOCK AND CONTROL BOARD REPLACED.
ELECTRIC BURNER TOO HOT IN LOW SETTING. HOW TO RELPLACE THE INFINITY SWITCH.
มุมมอง 1904 หลายเดือนก่อน
ELECTRIC BURNER TOO HOT IN LOW SETTING. HOW TO RELPLACE THE INFINITY SWITCH.
CEILING FAN LIGHTS DONT WORK OR FLICKERING. TROUBLESHOOTING. REPLACED WATT LIMITER.
มุมมอง 4324 หลายเดือนก่อน
CEILING FAN LIGHTS DONT WORK OR FLICKERING. TROUBLESHOOTING. REPLACED WATT LIMITER.
HOW TO REPLACE A KOHLER TOILET FLUSH VALVE SEAL
มุมมอง 21K5 หลายเดือนก่อน
HOW TO REPLACE A KOHLER TOILET FLUSH VALVE SEAL
REFRIGERATOR NOT COOLING ENOUGH. REPLACED FAULTY CONDENSER FAN MOTOR.
มุมมอง 6055 หลายเดือนก่อน
REFRIGERATOR NOT COOLING ENOUGH. REPLACED FAULTY CONDENSER FAN MOTOR.
DISH WASHER NOT WORKING. IT SHUTS OFF AFTER 2 MIN. PRESSURE SENSOR FAULTY
มุมมอง 975 หลายเดือนก่อน
DISH WASHER NOT WORKING. IT SHUTS OFF AFTER 2 MIN. PRESSURE SENSOR FAULTY
WATER HEATER INSTALLATION WITH RIDGID MEGA PRESS AND PRO PRESS.
มุมมอง 6665 หลายเดือนก่อน
WATER HEATER INSTALLATION WITH RIDGID MEGA PRESS AND PRO PRESS.
HOW TO REPLACE B AND G PUMP COUPLER AND MOUNTS (100 SERIES)
มุมมอง 3585 หลายเดือนก่อน
HOW TO REPLACE B AND G PUMP COUPLER AND MOUNTS (100 SERIES)
HOW TO REPLACE A WATER MAIN VALVE INSIDE A HOUSE WITH THREADED FITTINGS.
มุมมอง 4875 หลายเดือนก่อน
HOW TO REPLACE A WATER MAIN VALVE INSIDE A HOUSE WITH THREADED FITTINGS.
HOW TO INSTALL A CERAMIC FLOOR STEP BY STEP USING THE RUBI CYCLONE LEVELING SYSTEM.
มุมมอง 4156 หลายเดือนก่อน
HOW TO INSTALL A CERAMIC FLOOR STEP BY STEP USING THE RUBI CYCLONE LEVELING SYSTEM.
HOW TO REPLACE A WATER HEATER TEMPERATURE/PRESSURE RELIEF VALVE.
มุมมอง 2.1K6 หลายเดือนก่อน
HOW TO REPLACE A WATER HEATER TEMPERATURE/PRESSURE RELIEF VALVE.
WHITE RODGERS 1311-102 STEP BY STEP REPLACEMENT.
มุมมอง 7946 หลายเดือนก่อน
WHITE RODGERS 1311-102 STEP BY STEP REPLACEMENT.
HOW TO REPLACE A COPPER PIPE THAT WASNT COPPER . IT WAS BRASS!!!! YIKES!!!!
มุมมอง 4087 หลายเดือนก่อน
HOW TO REPLACE A COPPER PIPE THAT WASNT COPPER . IT WAS BRASS!!!! YIKES!!!!
HOW TO REPLACE A BOILER PRESSURE VALVE. SAFETY AND HOW IT WORKS.
มุมมอง 6177 หลายเดือนก่อน
HOW TO REPLACE A BOILER PRESSURE VALVE. SAFETY AND HOW IT WORKS.
WATER HEATER VS BOILER TEMPERATURE/PRESSURE RELIEVE VALVE. I REPLACED BOTH.
มุมมอง 2257 หลายเดือนก่อน
WATER HEATER VS BOILER TEMPERATURE/PRESSURE RELIEVE VALVE. I REPLACED BOTH.
BOILER LOW VOLTAGE THERMOSTAT WIRING PROBLEM. EASY FIX
มุมมอง 2437 หลายเดือนก่อน
BOILER LOW VOLTAGE THERMOSTAT WIRING PROBLEM. EASY FIX

ความคิดเห็น

  • @natep1661
    @natep1661 8 ชั่วโมงที่ผ่านมา

    What is the part number for the replacement ball valve?

  • @patodosamigos
    @patodosamigos 10 ชั่วโมงที่ผ่านมา

    Thanks!

  • @xavierroy12
    @xavierroy12 10 ชั่วโมงที่ผ่านมา

    Thank you, helped me find my AC's filter :)

  • @bangzoom8180
    @bangzoom8180 22 ชั่วโมงที่ผ่านมา

    This literally saved me $150-200. Much obliged.

  • @Samlol23_drrich
    @Samlol23_drrich วันที่ผ่านมา

    You’re up to 7k subs? Congratulations- you deserve it. Some of the best, most clear explanations on you tube. Hope you get all the way to 100k!

  • @user-hq8jr1ib3r
    @user-hq8jr1ib3r 3 วันที่ผ่านมา

    This was very helpful! Thanks!

  • @bunnibravo4647
    @bunnibravo4647 3 วันที่ผ่านมา

    Look, when a person enjoys their job, you know they’re good at their job and can be trusted. Subbed!

  • @Lcast81
    @Lcast81 5 วันที่ผ่านมา

    Hi, my gas line supply valve has a male flare end (the opposite of the one in this video) & the safety+plus fitting has the same so I can not connect it. Should I add a coupling? Or where can I find a safety+plus fitting with a female end?

  • @dennisgardner4010
    @dennisgardner4010 5 วันที่ผ่านมา

    Great explanation. Thank you!

  • @weaverron3751
    @weaverron3751 5 วันที่ผ่านมา

    thank you great job didn't know what the little washer was for till you .

  • @ChuckZeppelin
    @ChuckZeppelin 5 วันที่ผ่านมา

    Great Video! Thumbs up buddy! Thanks for posting!

  • @rico1074
    @rico1074 6 วันที่ผ่านมา

    Can you explain how to wire taco controller with white rogers zone valves?

  • @PolaCaKe890
    @PolaCaKe890 6 วันที่ผ่านมา

    Omg change that panel sir

    • @alexthehandyman3494
      @alexthehandyman3494 6 วันที่ผ่านมา

      Done!!! That was replaced!!! Thank so much for your comment.

  • @freddymedina9871
    @freddymedina9871 7 วันที่ผ่านมา

    Excuseme can I do the same for a propane tank. Can i use the same gas conector.?? Please let me know

  • @uu4u124
    @uu4u124 8 วันที่ผ่านมา

    Hello all, Can someone please me if the tiny gap (when placing the new flange over the pipe) between the outside of the old drain pipe and the inside of the new cast iron flange is sealed? Wont it leak? Or can it be sealed with a wax ring over it? Thanks

  • @jasonnance4223
    @jasonnance4223 8 วันที่ผ่านมา

    Do i need to prime the new pump or just drop it in and go? Thanks

    • @alexthehandyman3494
      @alexthehandyman3494 8 วันที่ผ่านมา

      Hello, unlike the shallow well pumps, this submersible dont have to be primed. thanks for watching.

  • @josemederos6096
    @josemederos6096 9 วันที่ผ่านมา

    What happens if it turn on red but no flames

    • @alexthehandyman3494
      @alexthehandyman3494 9 วันที่ผ่านมา

      More than likely the ignitor. It gets red but not hot enough. Oder ignitors still get hot but not strong enough . Check gas valve coils .

  • @pbananaandfriends
    @pbananaandfriends 9 วันที่ผ่านมา

    Thank you so much!!1

  • @russells737
    @russells737 10 วันที่ผ่านมา

    Very good job and great camera work. Thank you.

  • @zekenzy6486
    @zekenzy6486 11 วันที่ผ่านมา

    Great video. Thank you for sharing. May I ask, where do you order part ? is it on amazon , ebay, or somewhere's else ?

    • @alexthehandyman3494
      @alexthehandyman3494 11 วันที่ผ่านมา

      Hello, I get most of my appliance parts at GRP Genuine Replacement Parts. Thanks so much

  • @davidv775
    @davidv775 11 วันที่ผ่านมา

    Thankyou for your help

  • @steveanderson4447
    @steveanderson4447 12 วันที่ผ่านมา

    My water was barely working. The owner before me shut off the water softener/ iron removal so he could have water. I didn't live there until 6 months later. When I turned on the power breakers sparks happened. Turned out the pump was only getting half power. After getting full power to pump I could run the water softener/ iron remover ! Then every year There were more problems because the system was old. Pump, Tank, pressure regulator, leaks, faucets. Shallow well. About 8 years of repairs.

  • @julianpena144
    @julianpena144 12 วันที่ผ่านมา

    Will a bad flame sensor prevent the igniter to heat up/get hot? Just ordered a flame sensor on same model bcuz of a broke male connector. I'm just wondering if a broken sensor could be the reason the igniter doesn't turn on/heat up

  • @Samlol23_drrich
    @Samlol23_drrich 12 วันที่ผ่านมา

    Nicd job

  • @AllanKobelansky
    @AllanKobelansky 12 วันที่ผ่านมา

    Surprisingly repairable. The real issue is what was it on the control board that failed. Often it’s a capacitor that has failed. Easy to replace if you have soldering skills and can identify failed capacitors. Other than a manufacturing defect, there isn’t much a consumer can do to abuse the control panel.

    • @Samlol23_drrich
      @Samlol23_drrich 12 วันที่ผ่านมา

      I have a similar GE Profile, except its freestanding. Over the 12 years or so I've had to replace door switches, and the magnetron. You're right- parts available and fairly straight forward info out there. Now fixing circuiit boards at the component level? I've got 100% record. 100 percent of the time I need to buy a new board after trying to de-solder and replace.

    • @AllanKobelansky
      @AllanKobelansky 12 วันที่ผ่านมา

      @@Samlol23_drrich very funny comment. I’m more comfortable with a soldering iron than a screw driver. Then again, I’m an EE and not an ME.

    • @alexthehandyman3494
      @alexthehandyman3494 12 วันที่ผ่านมา

      @@AllanKobelansky That's very true Allan, I dont know if I threw away that board. Im going to troubleshoot that capacitor and try to replace it, just for fun. Thank you so much.

    • @AllanKobelansky
      @AllanKobelansky 12 วันที่ผ่านมา

      @@alexthehandyman3494 take a hi res picture of the board. If you’d like a pair of experienced eyes. Otherwise, look for bulging capacitors. Look for any burn marks on the board. Good luck.

  • @EvelynDimla-g6y
    @EvelynDimla-g6y 13 วันที่ผ่านมา

    Can I ask?

  • @user-jw9it9to2x
    @user-jw9it9to2x 13 วันที่ผ่านมา

    You solved a one year old problem for me and saved me a few hundred bucks. Plus my son thinks I'm a cool dude 😂! Bravo!

  • @joshbigman1745
    @joshbigman1745 13 วันที่ผ่านมา

    Thankyou

  • @sc666666
    @sc666666 13 วันที่ผ่านมา

    It looks like the stove might’ve been previously wired with a four prong. The grounding strap looks like it’s been removed. From what I understand with a three prong you need to replace that grounding strap from the ground Screw to the neutral.?

    • @alexthehandyman3494
      @alexthehandyman3494 13 วันที่ผ่านมา

      This was a brand new range. You can use a 3 or 4 prone cord. Just connect the forth green wire on the green screw. That's it. What you describe it sounds like wiring a sub panel where you remove the bonding bar between ground and neutral.

    • @sc666666
      @sc666666 12 วันที่ผ่านมา

      @@alexthehandyman3494 mine came new with a thin metal strip connecting the two poles. Instructions said for a three wire just hook up the three wires. For a four wire to remove that connection and hook the fourth wire to the ground.

  • @jeffkwasny4793
    @jeffkwasny4793 14 วันที่ผ่านมา

    U 4 got to grease the o rings

  • @knightrdrx
    @knightrdrx 15 วันที่ผ่านมา

    works for me..couldn't figure out how to litf it up ..i was twisting and puling

  • @markumisasi5142
    @markumisasi5142 16 วันที่ผ่านมา

    Sir, I want to ask, if the dryer heater is too hot the machine won't start, whereas if the dryer is cold the machine can start...what's the cause?

    • @alexthehandyman3494
      @alexthehandyman3494 16 วันที่ผ่านมา

      If the dryers ducts are not cleaned, the thermostat and / or limits will get hot faster because the heat is not going away to the exhaust thus the dryer will stop prematurily until the thermostat or limits cool down, then it will start again. If ducts are clean it can be that thermostat and limit are tired and old and needs replacement.

    • @markumisasi5142
      @markumisasi5142 16 วันที่ผ่านมา

      @@alexthehandyman3494 thank you sis, I want to ask again... if you have replaced the coil but the flame doesn't come out, what's the cause? Is there a problem with the flame sensor?

  • @wesmitebehighyxbx3451
    @wesmitebehighyxbx3451 16 วันที่ผ่านมา

    My air conditioner recently started only working as a fan and stays at 82, I've changed the filters and may have moved my thermostat wire out of place... I haven't tried to wash inside of it with a hose yet though, but please help! I'll send a picture if you can help at all

    • @alexthehandyman3494
      @alexthehandyman3494 16 วันที่ผ่านมา

      if. the thermostat bulb got out of place then is not. in contact with evaporator. That means it will run longer and never satisfy the temperature. So the room will be colder that needed. I think your problem is a different one.

  • @Claire-dw9mb
    @Claire-dw9mb 16 วันที่ผ่านมา

    So helpful, thanks!

  • @DavidAfriyie-ev8tp
    @DavidAfriyie-ev8tp 17 วันที่ผ่านมา

    Beautiful and precised explanation

  • @js887744
    @js887744 18 วันที่ผ่านมา

    how do you clean/maintain the drain hose on these units? I'm in a condo. I have no idea where it comes out of the condo building!

  • @sbond1963
    @sbond1963 18 วันที่ผ่านมา

    Unfortunately, the new mixer I have does not show hot or cold side. I can’t tell because when it came out, it just fell out.

  • @mxslick50
    @mxslick50 19 วันที่ผ่านมา

    As an electrician with 45 years of experience I would like to caution you and other HVAC professionals: Using your cheater to bootleg a neutral via the ground of equipment is seriously hazardous. Electricity seeks ALL paths back to it's SOURCE, including neutrals and grounds. (That is why, even in a properly designed and wired system, it is possible to shocked from a neutral wire as your body WILL divert a portion of the voltage to ground through you.) Grounds are never intended to be energized (as a neutral normally would be on a 120v circuit) they are there as a fault clearing path, to bond together equipment and metallic structures to the same electrical potential (preferably zero), and to help ensure equipment cannot get voltage on it due to faulty components. Every time you guys use that cheater, you are energizing the entire AC unit and anything metallic attached to it. (Want proof? Next time you use a cheater, take one of your meter leads and attach it to the unit you tied the cheater to. Take the other lead and touch that to any other unit (A/C, exhaust fan, etc.) nearby, you WILL read some voltage. Anything over 3 volts is a hazard.) That exposes anyone touching anything connected to it via a metallic path to potential and possibly lethal shocks. Anything that gets touched WILL divert some of the current though the person touching it. I have attended jobs where someone was severely shocked (and a few fatalities) from this exact scenario. I have also been shocked many times with neutrals simply because I was a partial current path with low enough resistance to get belted. And yes, I have used the same cheaters and have also gotten bit doing it. Your pump will most likely fail because the current it draws can burn open some part of the ground wire, fittings or connections. You now potentially have a completely ungrounded A/C unit, which will leave you open to liability. The solutions? One, use your battery powered vac pump, two, buy a 240v vac pump (they are out there) and connect it normally via the two hots and ground in the unit, three buy a surplus step down transformer rated at 1kva (will weigh about 20lbs and won't be too big) to step down to 120v for your pump, or four run the necessary lengths of extension cords to a regular 120v receptacle. STOP using the cheater, one day it will get you and you may not survive it. Final note: What is the #1 killer of electrical tradespersons? Shocks (and/or the resulting falls from getting shocked) due to complacency. They get away with tickling the dragon for so long, until the dragon strikes back. The end results are not pretty.

    • @armandorodriguez6447
      @armandorodriguez6447 6 วันที่ผ่านมา

      To hell with those cheater cords, not in the business of making units live. On route to Lowes and picking up heavy gages extension cords. Brother I thank you for posting this a million times and still that's not enough cause my life us priceless 💜 everyone that reads this,listen to this electrician he knows what he's talking about

  • @prepare3envelopes
    @prepare3envelopes 20 วันที่ผ่านมา

    4:46 could have removed the red wire all together and just attached the black wire to the blue wire. One less point of failure.

  • @hughjones6300
    @hughjones6300 20 วันที่ผ่านมา

    I have replaced many posts. I remove the old post. I then use a large auger bit in my drill to loosen rotted remains. I then pull out rotted debris and use my shop vac to clean out the hole. Then you have an existing concrete hole to put the new post in. No need for new concrete. Works every time.

    • @alexthehandyman3494
      @alexthehandyman3494 20 วันที่ผ่านมา

      thank you so much for your input!! Greetings!!

  • @ShotofLuxury
    @ShotofLuxury 21 วันที่ผ่านมา

    ✔️💯Nice, easy, quick & Str8 to the point‼️🎯Thank you‼️💎

  • @stevenaskari
    @stevenaskari 22 วันที่ผ่านมา

    Hi Alex. I have a coin op speed queen washer with model number SWTT21WN. Unfortunately it does not agitate or spin. When we put coin inside the machine, it feels up with with water and it just sits. I know the belt is good because I replaced it about 6 months ago and I just replaced the pump. Do you have any ideas what it might be?

  • @Jett1873
    @Jett1873 22 วันที่ผ่านมา

    Ty!

  • @rickforine1312
    @rickforine1312 23 วันที่ผ่านมา

    Nice

    • @alexthehandyman3494
      @alexthehandyman3494 23 วันที่ผ่านมา

      Thanks. Just to let you know I Have about 20 something videos on Speed Queens

  • @Steven-xx8wg
    @Steven-xx8wg 23 วันที่ผ่านมา

    I'm looking at going into multi-family right now and thank you so much for not only troubleshooting the original problem, but also how you /would/ troubleshoot the other components.

    • @alexthehandyman3494
      @alexthehandyman3494 23 วันที่ผ่านมา

      My Pleasure , I have tons of videos on appliances furnaces boilers etc etc.

  • @MaribelRamirez-gd3so
    @MaribelRamirez-gd3so 23 วันที่ผ่านมา

    👋👋 Hello, where are you located, I need your services asap I need help fixing my well. I have to turn the breaker on and off everytime we need to use water because the pump won't shut off on its own I've already replaced the switch and the control box like five times because it keeps burning out the capacitor.

    • @alexthehandyman3494
      @alexthehandyman3494 23 วันที่ผ่านมา

      Hello Maribel, I m sorry to hear that. I am by Elmhurst IL. But I am swamped!! Good luck.

  • @macarloskenny
    @macarloskenny 24 วันที่ผ่านมา

    Excellent video. What area is your business located?

    • @alexthehandyman3494
      @alexthehandyman3494 23 วันที่ผ่านมา

      Dupage County Illinois. Chicago West suburbs

  • @sallydavidson4471
    @sallydavidson4471 24 วันที่ผ่านมา

    There are many items in our homes that don't require a professional. Garage door springs can be deadly if you don't know what you're doing. I had mine replaced by a "professional" who also worked as a Chicago Fire Fighter. It worked ok but broke about 2 years later. I then called a real professional who told me that the reason the first replacement didn't last was that spring wasn't strong enough for my door. He showed me the difference too. It's now been about 9 years and it's still working great! 🪵🫵🫵

    • @alexthehandyman3494
      @alexthehandyman3494 23 วันที่ผ่านมา

      thank you so much for your comment. Im glad your garage is still working fine!!

  • @deniseperkins946
    @deniseperkins946 24 วันที่ผ่านมา

    This was very helpful today! Thank you so much.😊

    • @alexthehandyman3494
      @alexthehandyman3494 23 วันที่ผ่านมา

      Hello Denise, thank you so much. Dont forget to like and subscribe.

  • @horsth9566
    @horsth9566 24 วันที่ผ่านมา

    Nicely done. Really appreciate your taking the time to explain all the details. Thank you!