- 1 133
- 306 308
điện
เข้าร่วมเมื่อ 14 ส.ค. 2020
Share electrical, PLC Rockwell, powerflex 753,525, inverter, servo, burner, weight, loadcell .. .. và kinh nghiệm xử lý
connect encoder dot printer keyboard doesn't work
connect encoder dot printer keyboard doesn't work
มุมมอง: 1
วีดีโอ
Change Powerflex 753 110kw 14.004 new 16.002
มุมมอง 1019 ชั่วโมงที่ผ่านมา
Change Powerflex 753 110kw 14.004 new 16.002
solenoid valve sometimes working sometimes doesn't
มุมมอง 714 วันที่ผ่านมา
solenoid valve sometimes working sometimes doesn't
display list selector in factory talk views studio
มุมมอง 20หลายเดือนก่อน
display list selector in factory talk views studio
Eurotherm 3204 measure not right process variable
มุมมอง 83 หลายเดือนก่อน
Eurotherm 3204 measure not right process variable
powerflex 755TL 336kw test motor 90kw 176A
มุมมอง 154 หลายเดือนก่อน
powerflex 755TL 336kw test motor 90kw 176A
control damper SQ25( 410160) close 100%
มุมมอง 74 หลายเดือนก่อน
control damper SQ25( 410160) close 100%
Upload and download Sew servo Ipos program
มุมมอง 364 หลายเดือนก่อน
Upload and download Sew servo Ipos program
Bootp IP for powerflex 525 card on board
มุมมอง 124 หลายเดือนก่อน
Bootp IP for powerflex 525 card on board
Powerflex 4M terminal 2 forward, terminal 3 reverse, terminal 5 slow speed
มุมมอง 85 หลายเดือนก่อน
Powerflex 4M terminal 2 forward, terminal 3 reverse, terminal 5 slow speed
22- comm-e card Ethernet for powerflex 40
มุมมอง 1615 หลายเดือนก่อน
22- comm-e card Ethernet for powerflex 40
No please
Thay biến tần 525 có car internet 25 - com e2p . làm sao để biến tần mới nhận car này vậy bạn
@@thientruong722 bạn backup 1 bản của biến tần cũ sao đó download xuống biến tần mới. Nếu cùng công suất của firmware biến tần sẽ nhận được. Nếu có khó khăn thì nhăn tin cho mình. Chúc bạn thành công nhé.
Hi. Cũng được ah Bạn. Nhưng phải vệ sinh mặt kính sách và thường xuyên.
cho hỏi cái này đặt ngoài mặt kính được không a
Dạ e chào a, e muốn hỏi nếu mình muốn tắt ngõ ra out1 luôn thì có được ko ạ ? Mình chỉ dùng ngõ alarm thôi a
Bạn xem lại đi trong video nó ngắt output 1 luôn ah.
@share_electrical dạ ý e là tắt luôn đó a, tắt out1 và dãy số chạy từ 0-100 lun á, cái đó trên dc1020 này mình làm đc chứ ạ
@@anhtuuc7402đúng rồi ah. Cái thanh Bar graph từ 0 đến 100 là hiển thị theo output ah .output tắt thì nó cũng tắt.
chào a, hiện e cũng đang vướng cái con dc1020 vụ set alarm, cho e hỏi e muốn set nhiệt độ trên 60 báo còi, xuống 40 tắt còi thì làm như thế nào a nhỉ?
Nhiệt độ cài đặt bình thường bạn vẫn cài đặt là 40⁰C hay bao nhiêu ? Nhiệt độ từ 60 đến 40 là báo còi.
Nhiệt độ cài đặt bình thường bạn vẫn cài đặt là 40⁰C hay bao nhiêu ? Nhiệt độ từ 60 đến 40 là báo còi.
@@share_electrical à cái này e chưa biết a, e tính cài 60 cho ngõ ra alarm, tức là theo e hiểu là 60 nó sẽ xuất alarm , sáng đèn al1 trên dc1020 đó a, còn sau đó nó phải xuống 40 độ thì ngõ ra alarm mới tắt, đèn al1 hêt sáng ạ, mong a chỉ giúp em
Vậy bộ DC1020 bạn chỉ sử dụng để báo alarm ah hay vừa alarm vừa sử dụng để điều khiển nhiệt.
@@share_electrical dạ a cứ hiểu như sau: e có 1 con dc1020 đang dùng để điều khiển 4-20 1 van tuyến tính r a nên e dùng gõ alarm như 1 output relay ạ. Khi output relay có tác động sẽ kích sáng đèn con relay R.alarm. Lúc này tiếp điểm relay đóng lại, sẽ đồng thời báo còi và mở 1 van on off để cấp nước vào bồn ạ, nhiệt độ nước trên 60 độ sẽ báo còi và mở cho van điện cấp nước sạch và trung hòa bồn,khi xuống 40 thì tắt còi và tắt van điện ak
What is the solution !
Module 1756 EN3TR fault .i recycle power supply then it's working.
Hi. Display 0 inverter not ready. Check 24v operation X10 terminal 9, 10. I hope that helpful for you..
I am having issues with the same type of converter not changing from 0.to 1 Please I need support.from you sir
Encordor bị hỏng phải ko huynh đai
@@thienlong6692 dây encoder bị đứt dây tín hiệu. Mình Kéo lại dây mới.
@@share_electrical thấy hiện tượng là nghi ngờ rồi
Hi. Cuộc đời đưa đẩy mình tiếp xúc với thiết bị gì thì học cái đó. Bạn học ngành gì?
Cho em hỏi Anh học nghành gì vậy ạ
Hj. Mình học ngành điện ah. Bạn học ngành gì? Hy vọng chúng ta có thể trao dồi kiến thức cho nhau 😊😊
Anh học về nghành gì vậy ạ
Your video helped a water plant resolve this issue. Thanks.
How to fix
@@maddmuaz4558 hi. Normal VFD output UVW connect to UVW motor but I connect V to earth ground so VFD fault. I reconnect motor then it's working.
Have the same problem. How did you solve it?
Có con revison 7.0 làm sao thay con dang sử dụng 6 .0
@@thientruong722 Bạn thay đổi revision của biến tần trong studio 5000. Sau đó download xuống PLC. Trước đó bạn nhớ upload chương trình PLC và cả biến tần luôn nhé. Chúc bạn thành công..
How to solve the this fault?
@@Aamirshah11-m7m turn off power supply. If can not Clear the fault change new follow meter.
How did you fix this problem?
@@rickybyrd-mh1nh i changed vfd bigger than motor. Then it's working.
Thanks
Để kết nối và nhận card rời này thì cần set gì không vậy anh
@@tuan2782 bạn set địa chỉ ip sau đó off nguồn thì biến tần sẽ nhận card.
@@share_electrical cảm ơn anh nhiều
Instruction Storage Error e bị lỗi này là bị sao v a. Khắc phục đc k ạ
@@hongminh1960 em chưa bao giờ xử lý lỗi này ah. Nên cũng không rõ.
@@share_electrical ok, cảm ơn a
Merhaba hangi ülkeden yaşıyorsunuz
Like this
Tienes alguna solución para un powerflex 753 aparece no activado y Pérdi DPI prto 2
Port 6 Adapter error
I'm facing the same issue. What's the solution
Ethernet cable from VFD had problem.
boa noite tenho uma smc flex com uma placa de comunicalçao ethernet estou usando um micro850 gostaria de ter leitura de correntes das fases, consegue me ajudar obrigado...
anh có thể chỉ thêm khúc sau đồng bộ lại chương trình được không ak
Hj bạn. Khi đã cài đặt địa chỉ IP cho biến tần xong. Xem firmware trên biến tần và studio 5000 phải giống nhau. Nếu studio không nhận biến tần. Sau đó offline và mở biến tần trong chương trình studio 5000 lên và thực hiện đồng bộ giữa biến tần và file trong studio 5000. Nếu bạn có khó khăn thì có thể nhắn tin cho mình. 0933052412. Chúc bạn thành công và hạnh phúc trong cuộc sống..
Problemas en sensor de la llama o en valvula de gas para llama piloto
How con download
a cho em xin file cài đặt được không ạ
Hi bro I have same problem you can give me any solution
Hi. Good morning. You try to clear the fault if it can not clear. Check the cable. Check the terminal 5 và 6. It must be 24vdc.
I have same problem (SAFF).It is can not clear this after checking terminal 5 and 6.Can you give advice it.
P r o m o S M ✅
lỗi gì bạn?
Lỗi về Ethernet ah
How you solve this error?
Promo_SM
Vậy mình có cách nào không anh 😢
Hi. Good morning 1. Nếu chương trình không cần xử lý thật thật nhanh thì bỏ nó luôn. 2. Cho thời gian xử lấy lâu hơn tý. Hiện tại là 0.6ms. mình viết thêm timer 1.5ms sau đó test lại thử xem có ảnh hưởng gì không. 3. Ở đây mình sử dụng Ethernet. Kéo dây Ethernet từ VFD về trực tiếp PLC hoặc module mở rộng gần nhất có thể. Sẽ hạn chế bớt mất truyền thông. 4. Nếu vẫn không được thì không sử dụng Ethernet luôn. Cho VFD chạy theo terminal với tín hiệu analog. Hi vọng có thể giúp ít cho bạn. Chúc bạn thành công...
@@share_electrical cảm ơn anh nhé !
What is the difference between 0point mv and channel mv
How can i calibrate
Bạn sử dụng biến tần powerflex 753 luôn ah. Bạn chụp hình mình xem thử nhé.
Mình ko làm mất đk cái notenable
Ban sử dụng biến tần gì vậy. Có thể chụp cho mình tấm hình không?
Mình chuyển sau nó báo security enable
How to change motor direction
Còn đèn pointbus status đó báo đèn đỏ luôn không nháy. Lỗi bộ chuyển đổi bị tắt bus thì mình làm sao vậy anh
Anh chèn nhạc không nghe được tiếng rồi 😅
Can you hellp me Fault # 16 NO Load A thanks
Hello . I have default n15 Bypass over c ? I don't what cause and solution?
Bấm reset xong nó tự chạy auto ha bấm phím xanh(1) nó mới chạy auto v bn
Hj. Nó tự chạy theo chương trình điều khiển ah. Chạy thông qua Ethernet ah..
Reset song bật chạy lại báo lỗi
how to solve?