Let’s Have A Close Look At This, 4K quality, Mostly Electrician’s tools. Tool Look Channel, toollook channel.
A look at an electrical outlet in the Dominican Republic
A look at an electrical outlet in the Dominican Republic
มุมมอง: 72
วีดีโอ
Toughbuilt Stacktech (aka) the Darkside. Rolling chest, 3 drawer toolbox, organizer the best
มุมมอง 240หลายเดือนก่อน
Toughbuilt Stacktech StackTech™ is the world’s first auto-locking stacking tool storage solution. This modular toolbox system self-aligns to lock in a stackable position. With its built-in locking slider switch, it can be disengaged. It can be stacked for mobility purposes and it has a built in steel accessory rail for add-ons. -Stacktech Self Locking Toolboxes Rolling Tool Box Model #TB-B1-B-7...
Bosch Heated Vest USB Power Adapter GAA12V-21 GHV12V-2 12 volt
มุมมอง 109หลายเดือนก่อน
When used with the Bosch 12v battery in combination it will work as a power bank. GAA12V-21 Power Adapter GHV12V-2 Heated Vest Mcdodo right angle usb cable
Klein Tools at Lowes
มุมมอง 3605 หลายเดือนก่อน
Klein Hand Tools Klein Test Instruments and Klein Safety Gear Music: My Universe Artist: Nesterouk Site: pixabay.com/music/future-bass-my-universe-147152/
Ideal Electrician Tools w. Smart Grip and Tether Support, linesman, long nose, diagonal, & strippers
มุมมอง 2116 หลายเดือนก่อน
For more info, visit www.idealind.com For those who wonder…electricity can very dangerous and working with live voltage can lead to death. Consult with a licensed electrician to make changes Pliers 30-3430 Linesman w. Crimper 45-133 Long Nose Plier (Heavy Duty Stripper) 30-3028 Ideal Diagonal Plier 35-3038 Ideal Long Nose Plier 45-112 Ideal NM-B forged wire stripper Pouch and Accessories 37-100...
Best carry with multimeter. Compact, it packs Low Z, bar graph, capacitance, and NCV. The AEMC 5233
มุมมอง 2658 หลายเดือนก่อน
This one was tough, enjoy. Please note that the symbols for the dial selector do not light up. The effect is used to capture and highlight the talking points for educational purposes. -Feature AEMC 5233 Chauvin Arnoux Test Instruments Auto Ranging Multimeter, Low Z, True RMS, Bar Graph, NCV, Auto & Dual Off, Capacitance, Hertz, Duty Cycle -Other Test Instruments Supco Capdis (The Blue Marker) C...
Electrician Tool Vault Klein Knipex Ideal Fluke Channellock Bosch Dewalt Craftsman Lenox PC Greenlee
มุมมอง 2849 หลายเดือนก่อน
Another look at the brands sought after mostly by electricians and hvac technicians. Enjoy *For a good look, select the highest “Video Quality”* I set the power tool sounds to “denoise” to avoid any nuisance pitch coming from those using headphones and I kept background noise to a minimum. Without proper training electricity can be very dangerous. Consult with a licensed electrician. Here’s a l...
Wire Nuts, Ideal Wire Connectors, Wing Nut, Twister, InSure lever, pre twist, how to twist wires
มุมมอง 524ปีที่แล้ว
Wire Nuts, Ideal Wire Connectors, Wing Nut, Twister, InSure lever, pre twist, how to twist wires
Measure wire spools 🧵, with this cable length meter from UEI CLM100 Test Instrument
มุมมอง 14Kปีที่แล้ว
Measure wire spools 🧵, with this cable length meter from UEI CLM100 Test Instrument
3 Prong 4 Prong Dryer Outlet Receptacle Plug Nema 10-30R Nema 14-30R install wiring #dryer #dryers
มุมมอง 133Kปีที่แล้ว
3 Prong 4 Prong Dryer Outlet Receptacle Plug Nema 10-30R Nema 14-30R install wiring #dryer #dryers
Ideal Voltage Detector Tester, feat. Fluke Volt Alert, flashlight, high, low #idealindustries
มุมมอง 8Kปีที่แล้ว
Ideal Voltage Detector Tester, feat. Fluke Volt Alert, flashlight, high, low #idealindustries
Wera 168i #1 square 1000v⚡️insulated VDE #weratoolrebels #weratools #robertson
มุมมอง 6812 ปีที่แล้ว
Wera 168i #1 square 1000v⚡️insulated VDE #weratoolrebels #weratools #robertson
Electrician’s Tools to get, #idealindustries #ideal #kleintools #knipex #greenlee
มุมมอง 4462 ปีที่แล้ว
Electrician’s Tools to get, #idealindustries #ideal #kleintools #knipex #greenlee
Channellock Locknut Plier feat. GB Locknut Wrenches
มุมมอง 3.1K2 ปีที่แล้ว
Channellock Locknut Plier feat. GB Locknut Wrenches
Ideal Champion Limited Linesman, Strippers, Screwdriver 35-740
มุมมอง 4402 ปีที่แล้ว
Ideal Champion Limited Linesman, Strippers, Screwdriver 35-740
Old Work Electrical Boxes, Retrofit Boxes, or Remodel Boxes
มุมมอง 54K2 ปีที่แล้ว
Old Work Electrical Boxes, Retrofit Boxes, or Remodel Boxes
Ideal Twist a Nut Conduit Wiring Kit, Screwdriver, de-burrer reamer, tap tool #idealindustries
มุมมอง 2.2K2 ปีที่แล้ว
Ideal Twist a Nut Conduit Wiring Kit, Screwdriver, de-burrer reamer, tap tool #idealindustries
Klein Adjustable Stubby Screwdriver 32308 #kleintools
มุมมอง 1.4K2 ปีที่แล้ว
Klein Adjustable Stubby Screwdriver 32308 #kleintools
Klein Flip Sockets Nut Driver 32900 & 32907
มุมมอง 6392 ปีที่แล้ว
Klein Flip Sockets Nut Driver 32900 & 32907
Wire Strippers feat. #greenlee #idealindustries #kleintools
มุมมอง 2.3K2 ปีที่แล้ว
Wire Strippers feat. #greenlee #idealindustries #kleintools
Ideal 61-557 LoZ Voltage & Continuity with GFCI & NCV Tester
มุมมอง 4.7K2 ปีที่แล้ว
Ideal 61-557 LoZ Voltage & Continuity with GFCI & NCV Tester
Ideal 61-357 LoZ Bar Graph NCV 1000v⚡️ Multimeter Test Instrument
มุมมอง 3.4K3 ปีที่แล้ว
Ideal 61-357 LoZ Bar Graph NCV 1000v⚡️ Multimeter Test Instrument
A few from Lenox, Jab Saw, Cutter, Knife, & Snips
มุมมอง 3.9K3 ปีที่แล้ว
A few from Lenox, Jab Saw, Cutter, Knife, & Snips
Southwire Touchscreen Electrician’s Work Glove “Glove1”
มุมมอง 753 ปีที่แล้ว
Southwire Touchscreen Electrician’s Work Glove “Glove1”
Kobalt Stainless Roller Cabinet Tool Chest 893826
มุมมอง 1.2K3 ปีที่แล้ว
Kobalt Stainless Roller Cabinet Tool Chest 893826
Crescent Apex eShock-Guard⚡️1000v Isolators
มุมมอง 4.6K3 ปีที่แล้ว
Crescent Apex eShock-Guard⚡️1000v Isolators
It's sometimes lost in the translation that these old 10-30 plugs were designed for buildings that had no ground wire. They used the neutral to perform double duty, to give a neutral leg for circuits that required only 120 V inside the appliance and they used that leg for grounding the chassis frame. The problem with that was the way the cabinet of the appliance could become charged with voltage applied to the neutral wire, even from another appliance sharing that same neutral. When modern homes began including a ground wire, the intent was to make these obsolete so there would be no chance a neutral bond at the old appliance. Along came the 6-30 receptacles, which used two hots and a ground (no neutral). This worked great for welders and other devices that didn't require that half voltage neutral leg, it avoided any chance of inadvertent bonding of the neutral wire, and it provided a legitimate equipment ground that never had normal voltage or current applied. To prevent the two styles from being inadvertently mixed, they made the plug designs incompatible with each other.
The same deal with the nema 6-15r and 6-20r for 240v air conditioners. They ran on knobs at first and now they have digital displays sooo…they must be borrowing from the ground wire for neutral purposes on these air conditioners. It explains why they all use plastic faces.
This piece is 1000x better than the Klein volt/con tester.
1000% agree
The best only one nut screw driver is made by klein tools. It has sockets around the adjustible length 1/4 inch shank and storage in the handle for standard 1/4 inch bits. You can also remove the shank and use it in an impact driver.
I have a video on those impact rated Klein flip sockets that you’ve described. Check it out.
🥇💯❤
Thank you
Mike Holt discussed this on his channel: th-cam.com/video/y7rsHclQ5KE/w-d-xo.htmlsi=Ri1ImR2tzkSPMVut
They’re gone already
Yup, all gone
Great video! Amazing edition! Very informative!
Much appreciated, thanks
How primitive, grounding switches. Why not make them d9 that they do not need grounding?
Yes of course, right away. It looks like someone is proposing that we abandon the methods of grounding our primitive light switches…to perhaps convert to the much newer and sophisticated foreign norms, so that we can keep up with the times of our superiors in lighting technologies and rid ourselves of the peasantry.
thank you, almost went back in safety standards. My house has a 14-30 plug for the dryer and the one i picked up had a 10-30 plug.
Thanks
very informative👍🏽
Glad it was helpful!
Nice!
Thanks, these are definitely the carry with choice
Great video. Thanks.
Thank you and thanks for watching
Thank you so much for this.
You’re welcome
You are a master at making instructional videos brother.
Love the feedback. Thanks so much.
I have this screwdriver. It’s one of my favorites. Typical Lenox quality which is very good. I just learned the magnetic bit holder pulls out making it even shorter.
To me this one is the best, I always bring this one along. The switch is so easy to work.
Dumping the wire nuts on your table gave me some serious anxiety. Everything was better when I heard that two stroke Jimmy purring. 😊
Haha thanks. Glad you liked it.
Channellock are the best
When working with the plastic boxes, I've gotten into the habit of running the screw for the ears all the way down and then back out, before I install it. This loosens it up just a bit, and makes it much less likely the ear will flip over while trying to tighten it down.
Hehe, same here
you have the hairiest knuckles i have ever seen. BTW great video
Thanks
Whats yoir favorite color. Thats the difference.
Pretty much
Great idea, thank you
Thanks to you for watching
That’s clever. 👊🏾✨
@@yahmanmlthanks, much appreciated
If my electric dryer comes with a green wire screwed too the case do i just add the ground comming from a 4 wire updated cord? Nice video. Looking for this answer for hours .
Sometimes the jumper wire is green instead of white. The process doesn’t change for the 4 prong installation; that “green jumper” would still go in the center of the terminal block with the “white neutral wire” of the 4 prong power cord. For 3 prong power cords, DO NOT remove the “green jumper” or “white jumper” from the dryer’s metal frame.
@@toollookchannel thank you very much im so glad i came across your channel. Smoking hot lol
Thanks, look up TH-cam channel “Lorraine furniture and appliance”, the video is called “How to install a 4 prong power cord on an electric dryer”.
Use it with a torque wrench not an impact driver to be on the safe side
I meant to ask you earlier, WHERE did you get this huge selection of boxes? Did you get all of them at a REAL electrical supplier in a big city? Out here in central PA the real suppliers have surrendered to the big box stores, who carry only a narrow selection, and usually half of it is out of stock at any given time. I remember when I was about ten years old, how much I enjoyed looking through my grandfather's catalog of plumbing fittings ... wow, what a selection! Your video was almost that much fun. Thanks again for your excellent work putting it together!
I purchased the Gardner Bender, Southwire, and Cantex boxes at my local Lowe’s, (there’s good variety there). I ordered the Legrand box and one old work steel box. Everything Carlon was from Home Depot.
Absolutely EXCELLENT video! You showed me several box types I've never seen before (because the big box stores don't carry them). These are real problem-solvers. VERY informational content. (And no meaningless music, no ego-driven blather, just the exact content I needed.) Thank you again for posting this! You're a real champion!
Thanks for sharing your excellent feedback; so much gets edited out from these takes in favor of timing and which parts don’t feel like they go with the pace of the the content.
1:08😆
Great video great explanation great information I like the way you highlighted everything too
Thank you
4:05
I really like how you enhanced the talking points with graphics. I also liked how you ghost wired the plug. I think you did a great job explaining the information.
Thanks, I still look back at this video. Much appreciated
It would have to be a 4 prong
The Cantex box is just... dumb. Blue one is a far better design. Thank you for demonstrating both common options.
You’re welcome. The earlier Carlon boxes had the same template system as the Cantex. I believe at one point Carlon was selling more and Cantex may still be going through their old stock.
Thank you, man. Your video was super useful.
Good to know it and thanks for the feedback
I have a 4 wire 220 volt wire with 3 black wires and an exposed wire. 1 ribbed black wire, 1 solid black, 1 solid black with a faint red line, and 1 bare. Is the ribbed wire my Neutral? Mahalo in advance.
The best way to know is to use a test instrument, or to look for the sources at the panel
Awesome video! Much Mahalos 🤙
Thanks
This video is top shelf, seriously the first one I came across, trying to answer my question and you did such an excellent job, describing the problem and how to remedy it. Thank you!
Thanks for the feedback and glad to know that you got an answer from this content
I LIKE !!!!!!!!!!😀😀😀😀
Thanks…these take a while. Much appreciated.
Excellent video
Thank you, it’s very much appreciated
Very informative, thanks.
You’ve got it
Thanks for the instruction. Question: I need to replace a 240v/30amp 4 prong outlet to a 120v/30amp RV plug. Can I simply cap the extra hot wire and attach the other 3 (hot/ground/neutral) and call it good? Would there be any issue with the currently installed 2 pole breaker
It’s a bit messy, because now you’ll have a 2 pole breaker instead of a 1 pole….it’ll work. They also sell plug n play adapters
klein decline
Their revenue is up
just what i needed to know. going with the blue box
No problem; blue ftw
Excellent video. Helped me out. 5 ⭐️
Thanks, much appreciated.
The thermocouple at the end of the video is for newer versions such as version V that directly support the thermocouple. You need the Fluke 80TK temperature module for the Fluke 87.
That’s extremely helpful, thanks. I didn’t get the right thermocouple and the prices of those 80tk have skyrocketed.
I have an original Fluke 87. I purchased it around 1989 or 1990. I had to replace the elastomer strips that connect the PCB to the LCD display. This was a problem with the original version where the display would fade from bad contacts.
Wow you’re the original owner, that’s great. I had this same problem with the ghost screen when it arrived. I had luck by dismantling it and wiping the pin contact for the lcd with a Q-tip. It doesn’t always work and elastomer strips would’ve been my next step.
Awsome thanks
You’re welcome
Channellock the best
What do I do if I have the 10/2? 2 hot and a ground, no neutral white? Leviton 3 prong surface mount receptacle
Great question. I would consult with a licensed electrician if you’d like to have it serviced, or make any changes.
I’m relocating a range and was going to buy a new box and outlet. But I found an outlet Im and box in my garage (abandoned shop 220v) that matched up with my range… now I understand how to ground that box 👍🏼
That is awesome! If you get stuck, always ask the licensed professionals
Bro… flatline ---
Do you have to attach to opposite ends of the cable? That's not going to help for some spools where the other end is buried in the spool. I've seen videos of some of these that can tell the spool length by attaching to cable on the same end.
I saw a video like that and maybe I’m wrong about this…I believe the instruments you looked at are good for measuring smaller low voltage cables accurately, such as coax, or ethernet. The cable length meter in this video allows you to work with almost any gauge. A good pair of needle nose, or long nose pliers are very helpful.