Gold Gas (Sunnie)
Gold Gas (Sunnie)
  • 77
  • 987 692
THE BEST BOILER SERVICE & BREAKDOWN TOOL BAG - LOAD OUT - WHAT I CARRY FOR EVERY JOB - GAS TOOL KIT
The most common message I get is about what I carry for maintenance so here's a quick video.
The Best Service / Breakdown Tool Bag And Loadout.
My latest tools, gadgets and equipment.
Key features - lightweight, compact, fits everything I need with its design, comfort and practical.
Featuring:
Regin, Unilite, Velocity, Silverline, testo, Wiha, Bahco, Knipex, Wira
MAKE SURE TO SUBSCRIBE TO GET FIRST DIBS IN COMPETITIONS AND SEE BRAND NEW VIDEOS COMING SOON!
See my channel for more boiler goodness, including the, 'how to put boiler into service mode' AND 'Boiler faults list history viewer' Series
Subscribe and click the bell to see new videos!
If there is a particular video regarding gas boilers you would like to see, please comment below
มุมมอง: 5 954

วีดีโอ

IT DOESN'T TELL YOU THIS IN THE MANUAL - ALPHA INTEC BOILER LOSS OF FLAME SIGNAL E38 E43 - ALL FIXES
มุมมอง 14K3 ปีที่แล้ว
ALPHA INTEC BOILER LOSS OF FLAME SIGNAL E38 E43 - ALL FIXES Do not attempt unless you are Gas safe or under the supervision of someone Gas safe. Attempting this without a Gas Safe ID can be dangerous to you and people around you. This is aimed at people who don't service much, new to this boiler or trainees. All this information is already widely available. MAKE SURE TO SUBSCRIBE TO GET FIRST D...
CHEAPER BOILER SPARES?! SAVE MONEY - IS IT RIGHT TO FIT OTHER BOILERS PARTS IN ANOTHER BOILER?
มุมมอง 1.4K3 ปีที่แล้ว
FITTING OTHER MANUFACTURERS SPARES IN ANOTHER BOILER. WHAT DO YOU THINK? ALL THE SPARES I FIT I HAVE CONFIRMATION THAT ARE THE SAME. Do not attempt unless you are Gas safe or under the supervision of someone Gas safe. Attempting this without a Gas Safe ID can be dangerous to you and people around you. This is aimed at people who don't service much, new to this boiler or trainees. All this infor...
GLOWWORM / BRITISH GAS F1 FAULT - GAS VALVE FACTORY RESET- NOISY BOILER IGNITION - TECHNICAL WEBSITE
มุมมอง 9K3 ปีที่แล้ว
GLOWWORM ULTRACOM / BRITISH GAS 330 F1 FAULT - GAS VALVE FACTORY RESET- NOISY BOILER IGNITION - ASK GLOWWORM TECHNICAL WEBSITE Do not attempt unless you are Gas safe or under the supervision of someone Gas safe. Attempting this without a Gas Safe ID can be dangerous to you and people around you. This is aimed at people who don't service much, new to this boiler or trainees. All this information...
GLOWWORM ENERGY HIGH FIRE LOW FIRE SERVICE MODE P01 0-100
มุมมอง 21K3 ปีที่แล้ว
GLOWWORM ENERGY HIGH AND LOW FIRE (SERVICE MODE) Do not attempt unless you are Gas safe or under the supervision of someone Gas safe. Attempting this without a Gas Safe ID can be dangerous to you and people around you. This is aimed at people who don't service much, new to this boiler or trainees. All this information is already widely available. MAKE SURE TO SUBSCRIBE TO GET FIRST DIBS IN COMP...
ULTRACOM 2 COMING ON AND OFF ON IT'S OWN - TINY ECO PRE HEAT BUTTON - END USER CAN DO THIS!
มุมมอง 1.5K3 ปีที่แล้ว
THIS ONE IS FOR THE END USERS AS I'VE ATTENDED LOADS OF THESE AND IT'S A ONE MINUTE JOB. THE ECO BUTTON IS A PRE HEAT AND WILL HEAT YOUR HOT WATER THROUGH THE NIGHT AND WHILE YOUR'E AWAY AND IS A BIG WASTE OF ENERGY. UNLESS YOU GET THROUGH A LOT OF HOT WATER.
GLOWWORM ENERGY VIEW PREVIOUS FAULT / ERROR CODES HISTORY / MEMORY LIST
มุมมอง 9223 ปีที่แล้ว
IMPRESS THE CUSTOMER WITH YOUR KNOWLEDGE! HOW TO VIEW PREVIOUS FAULT CODES - SEE MY PLAYLIST FOR MORE BOILERS. HOW THIS IS HANDY: YOU GET BACKGROUND KNOWLEDGE ON THE BOILER AND YOU CAN TELL THE CUSTOMER IF THERE'S A PART POSSIBLY ON IT'S WAY OUT. EXAMPLE - IF THERE'S A CIRCULATION FAULT CODE YOU CAN CHECK FOR PUMP FAULTS, GIVE THE CUSTOMER A HEADS UP FOR FUTURE WORK, THEY MAY TURN AROUND AND SA...
WORCESTER GREENSTAR CDI VIEW PREVIOUS FAULT / ERROR CODES HISTORY / MEMORY LIST - CDI CLASSIC
มุมมอง 9K3 ปีที่แล้ว
IMPRESS THE CUSTOMER WITH YOUR KNOWLEDGE! HOW TO VIEW PREVIOUS FAULT CODES - SEE MY PLAYLIST FOR MORE BOILERS. HOW THIS IS HANDY: YOU GET BACKGROUND KNOWLEDGE ON THE BOILER AND YOU CAN TELL THE CUSTOMER IF THERE'S A PART POSSIBLY ON IT'S WAY OUT. EXAMPLE - IF THERE'S A CIRCULATION FAULT CODE YOU CAN CHECK FOR PUMP FAULTS, GIVE THE CUSTOMER A HEADS UP FOR FUTURE WORK, THEY MAY TURN AROUND AND SA...
GLOWWORM ULTRACOM VIEW PREVIOUS FAULT / ERROR CODES HISTORY / MEMORY LIST ULTRACOM CXI
มุมมอง 1K3 ปีที่แล้ว
IMPRESS THE CUSTOMER WITH YOUR KNOWLEDGE! HOW TO VIEW PREVIOUS FAULT CODES - SEE MY PLAYLIST FOR MORE BOILERS. HOW THIS IS HANDY: YOU GET BACKGROUND KNOWLEDGE ON THE BOILER AND YOU CAN TELL THE CUSTOMER IF THERE'S A PART POSSIBLY ON IT'S WAY OUT. EXAMPLE - IF THERE'S A CIRCULATION FAULT CODE YOU CAN CHECK FOR PUMP FAULTS, GIVE THE CUSTOMER A HEADS UP FOR FUTURE WORK, THEY MAY TURN AROUND AND SA...
WORCESTER GREENSTAR COMPACT VIEW PREVIOUS FAULT / ERROR CODES HISTORY / MEMORY LIST - COMPACT CDI
มุมมอง 7793 ปีที่แล้ว
IMPRESS THE CUSTOMER WITH YOUR KNOWLEDGE! HOW TO VIEW PREVIOUS FAULT CODES - SEE MY PLAYLIST FOR MORE BOILERS. HOW THIS IS HANDY: YOU GET BACKGROUND KNOWLEDGE ON THE BOILER AND YOU CAN TELL THE CUSTOMER IF THERE'S A PART POSSIBLY ON IT'S WAY OUT. EXAMPLE - IF THERE'S A CIRCULATION FAULT CODE YOU CAN CHECK FOR PUMP FAULTS, GIVE THE CUSTOMER A HEADS UP FOR FUTURE WORK, THEY MAY TURN AROUND AND SA...
VAILLANT BOILER VIEW PREVIOUS FAULT / ERROR CODES HISTORY / MEMORY LIST - ECOMAX ECOTEC VUW VCW PRO
มุมมอง 2.8K3 ปีที่แล้ว
IMPRESS THE CUSTOMER WITH YOUR KNOWLEDGE! HOW TO VIEW PREVIOUS FAULT CODES - SEE MY PLAYLIST FOR MORE BOILERS. HOW THIS IS HANDY: YOU GET BACKGROUND KNOWLEDGE ON THE BOILER AND YOU CAN TELL THE CUSTOMER IF THERE'S A PART POSSIBLY ON IT'S WAY OUT. EXAMPLE - IF THERE'S A CIRCULATION FAULT CODE YOU CAN CHECK FOR PUMP FAULTS, GIVE THE CUSTOMER A HEADS UP FOR FUTURE WORK, THEY MAY TURN AROUND AND SA...
WORCESTER GREENSTAR I RANGE VIEW PREVIOUS FAULT / ERROR CODES HISTORY / MEMORY LIST 24I 25I 30I 32I
มุมมอง 6K3 ปีที่แล้ว
IMPRESS THE CUSTOMER WITH YOUR KNOWLEDGE! HOW TO VIEW PREVIOUS FAULT CODES - SEE MY PLAYLIST FOR MORE BOILERS. HOW THIS IS HANDY: YOU GET BACKGROUND KNOWLEDGE ON THE BOILER AND YOU CAN TELL THE CUSTOMER IF THERE'S A PART POSSIBLY ON IT'S WAY OUT. EXAMPLE - IF THERE'S A CIRCULATION FAULT CODE YOU CAN CHECK FOR PUMP FAULTS, GIVE THE CUSTOMER A HEADS UP FOR FUTURE WORK, THEY MAY TURN AROUND AND SA...
ARISTON BOILER EVO E COMBI VIEW PREVIOUS FAULT / ERROR CODES HISTORY LIST
มุมมอง 33K3 ปีที่แล้ว
IMPRESS THE CUSTOMER WITH YOUR KNOWLEDGE! HOW TO VIEW PREVIOUS FAULT CODES - SEE MY PLAYLIST FOR MORE BOILERS. HOW THIS IS HANDY: YOU GET BACKGROUND KNOWLEDGE ON THE BOILER AND YOU CAN TELL THE CUSTOMER IF THERE'S A PART POSSIBLY ON IT'S WAY OUT. EXAMPLE - IF THERE'S A CIRCULATION FAULT CODE YOU CAN CHECK FOR PUMP FAULTS, GIVE THE CUSTOMER A HEADS UP FOR FUTURE WORK, THEY MAY TURN AROUND AND SA...
GLOWWORM CXI HXI SXI PREVIOUS FAULT ERROR CODES - VIEW HISTORY - ACCESS PREVIOUS FAULT MEMORY
มุมมอง 5233 ปีที่แล้ว
IMPRESS THE CUSTOMER WITH YOUR KNOWLEDGE! HOW TO VIEW PREVIOUS FAULT CODES - SEE MY PLAYLIST FOR MORE BOILERS. HOW THIS IS HANDY: YOU GET BACKGROUND KNOWLEDGE ON THE BOILER AND YOU CAN TELL THE CUSTOMER IF THERE'S A PART POSSIBLY ON IT'S WAY OUT. EXAMPLE - IF THERE'S A CIRCULATION FAULT CODE YOU CAN CHECK FOR PUMP FAULTS, GIVE THE CUSTOMER A HEADS UP FOR FUTURE WORK, THEY MAY TURN AROUND AND SA...
GLOWWORM ULTRACOM 2 VIEW PREVIOUS FAULT / ERROR CODES HISTORY / MEMORY LIST
มุมมอง 6013 ปีที่แล้ว
GLOWWORM ULTRACOM 2 VIEW PREVIOUS FAULT / ERROR CODES HISTORY / MEMORY LIST
REMEHA AVANTA PLUS VIEW PREVIOUS FAULT / ERROR CODES HISTORY / MEMORY LIST 24C 28C BROAG
มุมมอง 21K3 ปีที่แล้ว
IMPRESS THE CUSTOMER WITH YOUR KNOWLEDGE! HOW TO VIEW PREVIOUS FAULT CODES - SEE MY PLAYLIST FOR MORE BOILERS. HOW THIS IS HANDY: YOU GET BACKGROUND KNOWLEDGE ON THE BOILER AND YOU CAN TELL THE CUSTOMER IF THERE'S A PART POSSIBLY ON IT'S WAY OUT. EXAMPLE - IF THERE'S A CIRCULATION FAULT CODE YOU CAN CHECK FOR PUMP FAULTS, GIVE THE CUSTOMER A HEADS UP FOR FUTURE WORK, THEY MAY TURN AROUND AND SA...
VAILLANT BOILER VIEW PREVIOUS FAULT ERROR CODES HISTORY / MEMORY LIST - ECOTEC ECOMAX PURE PLUS PRO
มุมมอง 6K3 ปีที่แล้ว
VAILLANT BOILER VIEW PREVIOUS FAULT ERROR CODES HISTORY / MEMORY LIST - ECOTEC ECOMAX PURE PLUS PRO
ALPHA INTEC E-TEC INTEC 2 ECO VIEW PREVIOUS FAULT / ERROR CODES HISTORY / MEMORY LIST
มุมมอง 1.9K3 ปีที่แล้ว
ALPHA INTEC E-TEC INTEC 2 ECO VIEW PREVIOUS FAULT / ERROR CODES HISTORY / MEMORY LIST
IDEAL COMBI SUMP REPLACEMENT - EASY - LOGIC ESPRIT I24 - SPECIAL TOOL - BOILER REPAIR
มุมมอง 6K3 ปีที่แล้ว
IDEAL COMBI SUMP REPLACEMENT - EASY - LOGIC ESPRIT I24 - SPECIAL TOOL - BOILER REPAIR
ALPHA BOILER CD CDR HIGH FIRE LOW FIRE SERVICE MODE - PCB GAS VALVE ADJUSTMENT
มุมมอง 6K3 ปีที่แล้ว
ALPHA BOILER CD CDR HIGH FIRE LOW FIRE SERVICE MODE - PCB GAS VALVE ADJUSTMENT
GLOWWORM EASICOM HIGH FIRE LOW FIRE SERVICE MODE - HOW TO PUT GLOWWORM INTO SERVICE MODE HIGH FIRE
มุมมอง 4.6K3 ปีที่แล้ว
GLOWWORM EASICOM HIGH FIRE LOW FIRE SERVICE MODE - HOW TO PUT GLOWWORM INTO SERVICE MODE HIGH FIRE
VAILLANT HIGH FIRE LOW FIRE P01 P02 P0 - SERVICE MODE HOW TO PUT INTO HIGH FIRE P1 P2 PUMP PURGE
มุมมอง 21K3 ปีที่แล้ว
VAILLANT HIGH FIRE LOW FIRE P01 P02 P0 - SERVICE MODE HOW TO PUT INTO HIGH FIRE P1 P2 PUMP PURGE
BAXI ECOBLUE HIGH FIRE LOW FIRE SERVICE MODE - CH MAX DHW MAX MODE - BAXI 303 ON - BAXI SERVICE 303
มุมมอง 5K3 ปีที่แล้ว
BAXI ECOBLUE HIGH FIRE LOW FIRE SERVICE MODE - CH MAX DHW MAX MODE - BAXI 303 ON - BAXI SERVICE 303
IMMEDIATELY DANGEROUS NEW OLD BOILER - WHY YOU NEED A CARBON MONOXIDE ALARM & YEARLY SERVICE
มุมมอง 2K4 ปีที่แล้ว
IMMEDIATELY DANGEROUS NEW OLD BOILER - WHY YOU NEED A CARBON MONOXIDE ALARM & YEARLY SERVICE
(HD) ANNUAL BOILER SERVICE - MANUFACTURER INSIDE TIPS GASKET CHANGE MUST ALPHA INTEC BOILER SERVICE
มุมมอง 2.3K4 ปีที่แล้ว
(HD) ANNUAL BOILER SERVICE - MANUFACTURER INSIDE TIPS GASKET CHANGE MUST ALPHA INTEC BOILER SERVICE
NEGATIVE FAN PRESSURES - WORCESTER & ALPHA - HOW TO IMPROVE AND WHAT TO DO - ALL READINGS
มุมมอง 1.7K4 ปีที่แล้ว
NEGATIVE FAN PRESSURES - WORCESTER & ALPHA - HOW TO IMPROVE AND WHAT TO DO - ALL READINGS
My Service & Breakdown Boiler Repair Tool Bag Box- Service Load Out, Service Kit 5000 Boiler Service
มุมมอง 7K4 ปีที่แล้ว
My Service & Breakdown Boiler Repair Tool Bag Box- Service Load Out, Service Kit 5000 Boiler Service
BOILER SERVICE - ARISTON E COMBI - HOW TO SERVICE A BOILER - THE ULTIMATE SERVICE!
มุมมอง 16K4 ปีที่แล้ว
BOILER SERVICE - ARISTON E COMBI - HOW TO SERVICE A BOILER - THE ULTIMATE SERVICE!
ARISTON FAULT ERROR 501 S01 ERR SP1 SP2 - CUSTOMER / END USER EASY FIX - NO GAS
มุมมอง 31K4 ปีที่แล้ว
ARISTON FAULT ERROR 501 S01 ERR SP1 SP2 - CUSTOMER / END USER EASY FIX - NO GAS
NOISY TUMBLE DRYER FIX - HOTPOINT, INDESIT, CREDA, ARISTON, EXPORT, PROLINE, CLATRONIC .. - SQUEAKY
มุมมอง 78K4 ปีที่แล้ว
NOISY TUMBLE DRYER FIX - HOTPOINT, INDESIT, CREDA, ARISTON, EXPORT, PROLINE, CLATRONIC .. - SQUEAKY

ความคิดเห็น

  • @boxercup1
    @boxercup1 3 วันที่ผ่านมา

    Brilliant, £4.75 on Amazon, thank you 🙏 👍🏻

  • @AlanGorvett
    @AlanGorvett 4 วันที่ผ่านมา

    Boiler lights then goes out

  • @philipoakley5498
    @philipoakley5498 5 วันที่ผ่านมา

    Helped greatly. I'd had the funny flashing box (top left corner; bottom right corner) with a 94 number apparently inside it. Didn't appear to match any fault code nor was the flashing 'box' in the manual, so a bit stumped. Your video was clean and clear on getting the tru old code. Had to watch your finger for the final 'get back to normal' step 😅. All good.

  • @andrewscourfield7530
    @andrewscourfield7530 หลายเดือนก่อน

    Great information thanks

  • @morkyykrom7109
    @morkyykrom7109 หลายเดือนก่อน

    +++

  • @ciaralea4423
    @ciaralea4423 หลายเดือนก่อน

    How do you unravel the clips on top of heat exchanger. I really struggle

  • @daviddoonan5884
    @daviddoonan5884 หลายเดือนก่อน

    How do you unlock this valve

  • @martingill6996
    @martingill6996 2 หลายเดือนก่อน

    Nice one 👍🏼

  • @simonwilson6022
    @simonwilson6022 2 หลายเดือนก่อน

    It’s a great feeling when you’ve done all that and the fan pressure test is worse than before you fucking started, new heat exchanger here we come.

  • @katwoodytham8314
    @katwoodytham8314 2 หลายเดือนก่อน

    how do you change selector knob if broken

  • @MbeforetheS
    @MbeforetheS 2 หลายเดือนก่อน

    Legend, you’ve just saved me a fortune. After 3 weeks of no hot water I replaced pcb (thankfully a cheap eBay second) and still failed. Put on my big girl pants to have a go myself in the depths of the scary boiler beast and Venturi was completely blocked. Quick cocktail stick and pipe cleaning and now fires again, better than before. Very grateful you enabled me to fix myself with zero boiler knowledge. Thank you!

    • @katedunn-m8n
      @katedunn-m8n 25 วันที่ผ่านมา

      We have exactly same issue did you try the suck the tube thing first or just clean the Venturi straight away?

  • @pnmbmw
    @pnmbmw 3 หลายเดือนก่อน

    Do you have an annual service video for the Baxi neta-tec combi 33ga, Thanks

  • @attiqahmed3400
    @attiqahmed3400 3 หลายเดือนก่อน

    Will the fga not pick up that Co around the site glass ?

  • @deeche-j8n
    @deeche-j8n 3 หลายเดือนก่อน

    my manual air vent is leaking water continuously, any ideas why? Gonna call the plumber tomorrow

  • @ismails8155
    @ismails8155 4 หลายเดือนก่อน

    Thanks mate, explained in detail, very helpful

  • @deancbk3910
    @deancbk3910 4 หลายเดือนก่อน

    for those whose tubine is stuck solid. 1. remove pump (2 screws). That will give you space. 2. Use 18 mm six sided socket (from toolstation). standard 18 mm 12 sided will slip. 3. get a breaker bar, or extended rachet. (spray some wd40 on flow turbine) you should be able to get off.

  • @visioncrystal8234
    @visioncrystal8234 4 หลายเดือนก่อน

    could be a better video

  • @malcolmclarke2832
    @malcolmclarke2832 5 หลายเดือนก่อน

    That's a proper service there, cheap engineer just checking operation and clean trap

  • @tk4270
    @tk4270 5 หลายเดือนก่อน

    We had groaning noise each time boiler fired up, which has now disappeared after engineer from Ideal replaced burner because we weren't getting any hot water.

  • @tamaraj8616
    @tamaraj8616 5 หลายเดือนก่อน

    Thank you so much, worked a treat. 🎉

  • @helipilot7055
    @helipilot7055 6 หลายเดือนก่อน

    Got red and green lights flashing, changed the PCB but still the same cant reset?

  • @charliefox6987
    @charliefox6987 6 หลายเดือนก่อน

    good vid mate , ive recently qualified so this sort of content is well handy

  • @thomasbell6655
    @thomasbell6655 6 หลายเดือนก่อน

    This video gave 0 information regarding the noise cure

  • @jameswilson2899
    @jameswilson2899 6 หลายเดือนก่อน

    Great videos mate, they are a great help.

  • @sniper_gameshot5520
    @sniper_gameshot5520 6 หลายเดือนก่อน

    Once a took it out service mode just getting message c-On and number you know why

  • @neo_265
    @neo_265 6 หลายเดือนก่อน

    Thanks for sharing. I’ve got a Baxi Platinum and an 18mm socket fits well but the whole cartridge is seized in the manifold…..I’ve tried a lot of force but it’s not moving. Any tips? Thanks.

  • @mikebro2557
    @mikebro2557 6 หลายเดือนก่อน

    I turned the square plastic bearing block round on the back of the machine but the scraping noise is still present as if the front of the drum is rubbing on metal, but further investigation shows there is a felt lining between the front rim of the drum and the plastic door housing, looks like I will have to buy a new one 😢 thanks for video anyway 👍

  • @chumber05
    @chumber05 7 หลายเดือนก่อน

    Great support,thank you for uploading videos

  • @MaxEpsom
    @MaxEpsom 7 หลายเดือนก่อน

    Do you have to replace the gaskets when you talk fan off and main heat exchanger off

  • @ethanhoward5084
    @ethanhoward5084 7 หลายเดือนก่อน

    Hi, I have an ariston e combi evo. Do you know if a smart thermostat would be compatible with it, and which one? At the moment we have no thermostat and can only control the heating through on/off on the boiler. Thanks

  • @candymanoooooo
    @candymanoooooo 7 หลายเดือนก่อน

    Just has our boiler serviced by heatforce who fitted the boiler 3 years ago and they didnt do half of what you did when they serviced it as i was there the whole time, it has a TF1 Sigma filter should he cleaned this as he didnt do anything we paid a lot for the service and he didnt seem to do much for the ammount we paid

  • @MrAps-jh2qb
    @MrAps-jh2qb 7 หลายเดือนก่อน

    Amazing 👍

  • @bryngrant1531
    @bryngrant1531 8 หลายเดือนก่อน

    Great tips 👍

  • @macpatel7810
    @macpatel7810 8 หลายเดือนก่อน

    Another great video fella. Not sure how i missed it previously..

  • @scramblerman2536
    @scramblerman2536 9 หลายเดือนก่อน

    Terrible video !

  • @mark5282
    @mark5282 9 หลายเดือนก่อน

    Entering the engineer mode when setting the output is this the percentage output or the temperature. I want to use this for balancing so as to have a constant output. Modulation is great not just when you are trying to set a drop which keeps changing.

  • @ivarssmocs4220
    @ivarssmocs4220 9 หลายเดือนก่อน

    Hi, i have ariston combi clas evo he boiler , when i try on test mode change from heating to hot water and open hot water pipe nothing happened , heating working perfect, but no hot water😢

  • @b1h2u3p4
    @b1h2u3p4 9 หลายเดือนก่อน

    Didn't work for me as previous person used loctite couldn't even undo it with grips

  • @aghasahib4703
    @aghasahib4703 9 หลายเดือนก่อน

    203 code ?

  • @pstrese8287
    @pstrese8287 9 หลายเดือนก่อน

    many thanks for your video, it's the only one I found that actually explains draining the boiler, and not the whole system. Need a little help from you or anyone else that can help me with this query. The screws that you turned to stop the hot and cold water flow has imbedded screws. Do I need to loosen the inner screw before shutting of the flow to the taps? I need to replace the heat exchanger.

  • @tigerman558
    @tigerman558 9 หลายเดือนก่อน

    Suprima 100L Same problem get spark but no start up. Checked the venturi valve as video but the 100L looks nothing like yours. Only 1 cm long within fan and opening full dia size 3mm. Is that correct?

  • @ryanbeauchamp3075
    @ryanbeauchamp3075 9 หลายเดือนก่อน

    😊

  • @PeaceBeTheJourney.
    @PeaceBeTheJourney. 9 หลายเดือนก่อน

    My Alpha cd32 burner was only firing for 50 seconds before switching off every 4 minutes. Radiators are all hot. The burner short cycles even when warming the system from cold. The upper pcb dial is turned to full burn. Is this dial used to enter service mode or to safely turn down the burner and reduce cycling on and off?

  • @jadepantlin4322
    @jadepantlin4322 9 หลายเดือนก่อน

    My boiler keep displaying 0 and won't come on with water or heattint

  • @malcolmbramhall5382
    @malcolmbramhall5382 10 หลายเดือนก่อน

    I have a six year old Alpha intec boiler and it has broken down with the same thing once a year, every year since installation. The diverter valve goes. Is this a problem on all Alphas? I could do with knowing how to change one when the warranty runs out.

  • @MrHsHotPot
    @MrHsHotPot 10 หลายเดือนก่อน

    This worked for me! So a big thank you for making this video has this has saved me from having no hot water or central heating over Christmas. 👍

  • @chantellea777
    @chantellea777 10 หลายเดือนก่อน

    What happens if you have an e10 error you've added water pressure to the green area to about 1 and boiler still doesn't kick in

  • @rizayusefi1165
    @rizayusefi1165 10 หลายเดือนก่อน

    Great video! Thanks 🙏

  • @mAsadiq
    @mAsadiq 10 หลายเดือนก่อน

    Have a green star 30 cdi. All the lights are flickering. What could be the fault? Thanks

  • @krzysztofdrzymala
    @krzysztofdrzymala 10 หลายเดือนก่อน

    Hello, I have a Vibe 25a gas stove. I have a problem with turning on the stove.The furnace has a problem with starting. When I hit the integrated circuit board, the furnace starts.The question is which relay is responsible for starting the furnace.