- 85
- 216 070
itz electrical
India
เข้าร่วมเมื่อ 21 ก.ย. 2021
Hello Friends Welcome to my Channel. Here your can watch and learn pratical things about Electrical Field. I also provide project oriented knowledge and also installation, testing and maintenance of electrical Equipments/ Devices/ Accessories. So keep watching my videos and share your love. Thank you 🙏
Contactor Noise kar raha he kese maintenance karen?
Contactor Noise kar raha he kese maintenance karen?
มุมมอง: 187
วีดีโอ
Part 1 | Under Voltage Protection Setting Calculation for transformer | Micom P127, ABB REJ601 relay
มุมมอง 1K3 หลายเดือนก่อน
In this video I am explaining about Under voltage protection setting calculation. This calculation is only applicable for numeric relay. The factors required to calculate the Under voltage protection setting are 1) PT ration 2) Under voltage value You can check following related video Part 1| Earth Fault Protection Setting Calculation for Transformer | Setting ABB REJ 601 Micom P127 th-cam.com/...
Part 1 | Electrical Interview Question & Answer for ITI, Diploma, B. tech | Electrical Contactor
มุมมอง 7224 หลายเดือนก่อน
In this video I am explaining interview questions and answers on electrical contactor. The questions and answers that I discussed in this video are 1) What is an Electrical Contactor? 2) How Electrical Contactor work? 3) What is auxiliary Supply in contactor? 4) How much Voltage is required to ON the contactor and which supply we should use AC or DC? 5) Contactor works on which Principle? Elect...
Part 1| Earth Fault Protection Setting Calculation for Transformer | Setting ABB REJ 601 Micom P127
มุมมอง 1.7K4 หลายเดือนก่อน
In this video I am explaining about earth fault protection setting calculation. This calculation is only applicable for numeric relay. The factors required to calculate the earth fault protection setting are 1) CT ration 2) Full load current 3) Earth fault current range I already uploaded a detailed video on earth fault protection setting Part 2 | Earth Fault Protection Setting | How to do eart...
Electrical Contactor working mechanism | How to open contactor | what is inside the Contactor
มุมมอง 1034 หลายเดือนก่อน
In this video I am showing what inside the electrical contactor and how each and every part works. Hear you can get practical exprience on contactor and it's working principle. For more interesting video please subscribe my channel. What is Electrical Contactor? How Contactor works? Partical video | NO, NC explained in detail th-cam.com/video/zAEp2GHUcRE/w-d-xo.htmlsi=DpZTfzRglUOeMc1n #electric...
What is Electrical Contactor? How Contactor works? Partical video | NO, NC explained in detail
มุมมอง 1074 หลายเดือนก่อน
What is Electrical Contactor? How Contactor works? Partical video | NO, NC explained in detail
Part 2 | Earth Fault Protection Setting | How to do earth fault protection setting in numeric relay
มุมมอง 1.2K4 หลายเดือนก่อน
In this video I am explaining about the earth fault protection setting. I discussed the following points, 1) What is earth fault ? 2) How earth fault occurs? 3) How to do earth fault protection setting ? 4) Interview Related Questions. There are 4 things to calculate the earth fault setting. I) CT ration which is connected with relay. II) Full load current of equipment. III) Earth fault Current...
Part-2 | Danfoss VFD parameter setting | VLT Automation Drive Parameter setting
มุมมอง 2.1K4 หลายเดือนก่อน
In this video I am explaining about the parameters setting of Danfoss VFD / VLT HVAC drive. Here I am showing some basic settings in 0- Operation/ Display : - Language Setting - Speed setting (RPM / Hz) 1- Load and Motor : - Motor Power in KW - Motor Voltage in Volt - Motor Frequency in Hz - Motor RPM 3- Reference/ Ramps - Motor Minimum Speed Reference Limit - Motor Maximum Speed Reference Limi...
AKS 38- Danfoss Level Controller Working Principle
มุมมอง 4124 หลายเดือนก่อน
AKS 38- Danfoss Level Controller Working Principle
Danfoss VFD Parameter setting | VLT HVAC Drive | Part - 1
มุมมอง 4554 หลายเดือนก่อน
Danfoss VFD Parameter setting | VLT HVAC Drive | Part - 1
PLC for Beginners | IO Card Part - 3 | Input Output Card brief explain
มุมมอง 2295 หลายเดือนก่อน
PLC for Beginners | IO Card Part - 3 | Input Output Card brief explain
Easy Way to Programming in Schneider Electric EM6436H programming | EM6436H Parameter setting Hindi
มุมมอง 2795 หลายเดือนก่อน
Easy Way to Programming in Schneider Electric EM6436H programming | EM6436H Parameter setting Hindi
etaSMART 12R APFC controller not working in Auto Mode | Step by Step check Part - 9
มุมมอง 2.9K6 หลายเดือนก่อน
etaSMART 12R APFC controller not working in Auto Mode | Step by Step check Part - 9
WIKA Pressure Sensor, Transducer, Transmitter explained | Working Principle Hindi
มุมมอง 1.3K7 หลายเดือนก่อน
WIKA Pressure Sensor, Transducer, Transmitter explained | Working Principle Hindi
OLTC Operation | On Load Tap Changer in Transformer | Part - 1
มุมมอง 9867 หลายเดือนก่อน
OLTC Operation | On Load Tap Changer in Transformer | Part - 1
3 Min Video Series V-01 | etaSMART 12R Parameter Setting in just 3 minutes
มุมมอง 4107 หลายเดือนก่อน
3 Min Video Series V-01 | etaSMART 12R Parameter Setting in just 3 minutes
PLC for Beginners | IO Cards part - 2 | Basic Details of Terminal Block
มุมมอง 2318 หลายเดือนก่อน
PLC for Beginners | IO Cards part - 2 | Basic Details of Terminal Block
Over Current Protection Setting Calculation in details | Part 2
มุมมอง 7K8 หลายเดือนก่อน
Over Current Protection Setting Calculation in details | Part 2
PLC for Beginners | IO Card Part - 1 | Input Output Card Basics, Installation
มุมมอง 1.1K9 หลายเดือนก่อน
PLC for Beginners | IO Card Part - 1 | Input Output Card Basics, Installation
How to clear all the energy and hi low parameters in WL4410 multifunction meter | Part 4
มุมมอง 49910 หลายเดือนก่อน
How to clear all the energy and hi low parameters in WL4410 multifunction meter | Part 4
How to Read WL 4410 Digital Multifunction Meter| WL 4410 part 3
มุมมอง 2K11 หลายเดือนก่อน
How to Read WL 4410 Digital Multifunction Meter| WL 4410 part 3
How APFC Controler On or Off the Capacitor bank | Part 8 | Capacitor Switching Sequence
มุมมอง 1.9Kปีที่แล้ว
How APFC Controler On or Off the Capacitor bank | Part 8 | Capacitor Switching Sequence
WL4410 Programming | Detail Programming of Multifunction Meter
มุมมอง 4.2Kปีที่แล้ว
WL4410 Programming | Detail Programming of Multifunction Meter
WL4410 | Wiring and Basic details of Digital Multifunction Meter | Part 1
มุมมอง 1.3Kปีที่แล้ว
WL4410 | Wiring and Basic details of Digital Multifunction Meter | Part 1
Power Cable every parts detail video | LT cable used in industries
มุมมอง 178ปีที่แล้ว
Power Cable every parts detail video | LT cable used in industries
How to check Cable is PVC insulated or XLPE insulated (XLPE -Cross Linked Polyethylene) | LV cable
มุมมอง 948ปีที่แล้ว
How to check Cable is PVC insulated or XLPE insulated (XLPE -Cross Linked Polyethylene) | LV cable
Fire Tube Boiler | Some Basic Parts of Boiler
มุมมอง 283ปีที่แล้ว
Fire Tube Boiler | Some Basic Parts of Boiler
Cable Jointing training | Heat Shrink Cable Joint | LV cable 3.5C 150 sq.mm
มุมมอง 30Kปีที่แล้ว
Cable Jointing training | Heat Shrink Cable Joint | LV cable 3.5C 150 sq.mm
FAN and HOOTER connect with APFC relay | Part 7 | EtaSmart 16R
มุมมอง 2.3Kปีที่แล้ว
FAN and HOOTER connect with APFC relay | Part 7 | EtaSmart 16R
Thanks videos
❤❤❤❤❤❤❤
Good Video Sir, handle se bhi tap change krna sikheye, Tap change krke voltage ke change ka calculation bhi bateyega Sir please
Required kvar - 2.7 dikha raha hai isko correct kaise karen
AK ws no do please usi me vejunga sir
Ap ko keyase picture veju
Mera ek problem hua he
If uv relay not energiesd due to any fault then how we manually up the liver of uv relay for acb charging. Your vedio is appreciable .I am Israr abbasi from Pakistan.
U should remove the uv relay and start ACB
wrong calculation , your CT ratio is 60/5=12 not 60/1=60
👍
Accha
Sir relay m setting kr k b ta do
Dono taraf kitna kat te he
Hi
plz show the pressure display panel for this tranducer ,
Hallo
hi sir i have one problem in apfc how to contact you
Et aultra 8t +8R auto mode work karat nee
well explained, need more videos like this
Please send Overvoltage protection calculation video with time delay TMS for 33 kv /3.3 kv
Very helpful video
We have etasmart 12R, we have kept 800/5A CT, when we powered on ALL capactors switching ON with out load on busbar, apfc controller showing lag, actual measurements it was showing 160,200A, without load, please guide me on this...
We have etasmart 12R, we have kept 800/5A CT, when we powered on ALL capactors switching ON with out load on busbar, apfc controller showing lag, actual measurements it was showing 160,200A, without load, please guide me on this...
Check step by step my all 9 video on etasmart controller. You can find a playlist on it. After watching all those video you can get your solution
Thanks you sir
Nice
Menimu ketne Load par on karygi
App ke ct ratio per depend karta he aur app ka minimum capacitor ka value per bhi
app ka CT agar 2000 Amp ka he toh 2000x0.015 = 30 Amp that is 30 amp load ke uper app ka etasmart controller work karega. Similarly app ka CT agar 1000 Amp ke ho toh 1000x0.015 = 15 amp load ke uper work karega
And make sure if your load is very low like 50 amp- 100 amp then you should have low rating capacitor bank like 1 kvar, 2 kvar, 3 kvar and 5 kvar other wise your powerfacor will not maintained
Over compensation fault aa raha hai please solution
Useful demo. You didn't discharge the cable after meggering.
CT ratio 60/1, 0.7 & CT ratio 60/5 for same 0.7??. I>0.7In for CT retio 60/1, I>0.7In for CT ratio 60/5.?? Same setting?? Not clear it. Please explain. Thanks.
Thanks sir
Sir,Kitna amp ka CT lagana chahiye
Hello.what is IF?
SIR,AUTO MODE AUTOMATICALLY ONE CAPACITOR RUNNING.BUT WE HAVE NO NEED.HOW TO RECTIFY THE PROBLEM
Check my apfc controller videos part -1 to part - 7 , you get your solution
Reduce the turbulance and Glycerine liquid
Need setting of undervoltage
Ok
@itzelectrical plz provide we a RET 615 REALY
Hyy
I-THD valve change option not available in 16r realy pl help
Watch my part 5 and part 6 video on etasmart controller in my playlist
How to set multiplying factor please explain
How set multiflying factor
There is no option for multiplying factor as we set CT and PT ratio, the controller algorithm will automatically calculate the multiplying factor
@@itzelectrical sir can you share your contact no we have some query about these meter
Where you facing the problem tell me, I will guide through comment
Cable jointing yek jagah pe nhi hona chahiye
Yeh jo joint kia he wo 3M jointing kit jo ham use kar rehehen uske guidelines ke hisab se hi kia he
Kit ke saath ek manual ata he usi me jese bataya he usi hisab se hi jointing kia he mene
Are xlb ko bina nikale usko round save me hammer se pitna tha wo khud round hojata perfect na ki grand krna h jahan grand ki suvidha nhi h wahan kya kroge jangle jhad me
Mene to wohi kaha he incase round hone ke baad bhi cable insert na ho toh grind karne ke lie warna nehi
Very useful video, please make more...
Waiting for next video
Will be uploaded at the end of this month
Híi sir please send me number mobile
Password bhul gaya to kya kare
Sir very nice explain ❤🎉
Mast content hai 😊
Mera idhar I0>, I0>> aisa hain
Very informative sir❤
Bhai abhi tum joint Sikh ke aao Is field mein tum abhi naye Ho Calender se ghisa nahin jata hai Keral ghusane ke liye Keval round Kiya jata hai Disha nahin jata hai 😂😂😂😂
Yes you are right but some time it's very difficult to insert the cable and during shutdown you have to do the jointing in minimum time so this is the way you can do the jointing in less time.
And if your thimble size is small this is the way to jointing.
Aur mene round karne ka baat bhi kiya hun, and bataya hun agar round na ho and thimble na ghuse tabhi grinder karna