MassHunter Qualitative Analysis - Ep07 - exporting results in CSV, PDF, custom workflows
มุมมอง 1912 หลายเดือนก่อน
using DA reprocessor and custom workflow builder for automating acquisitions (importing formulae from a worklist)
MassHunter Qualitative Analysis - Ep06 - Compound Discovery with TOF MS/MS data in a workflow
มุมมอง 2812 หลายเดือนก่อน
How to confirm identification of molecular features using MS/MS. See video Ep05 in the series for creating MS/MS inclusion list.
MassHunter Qualitative Analysis - Ep05 - Compound Discovery with TOF MS data
มุมมอง 1572 หลายเดือนก่อน
Using Molecular Feature Extraction (MFE) - estimating background noise, formula prediction using molecular formula generation (MFG). Using databases to assign IDs and exporting for MS/MS
MassHunter Qualitative Analysis - Ep04 - RNA Oligo UV purity determination
มุมมอง 1162 หลายเดือนก่อน
Manual reviewing and automated workflow of RNA Oligonucleotide UV data, verifying delay times and determining the purity of the peak using different approaches. Includes some tips on integration algorithms.
MassHunter Qualitative Analysis - Ep03 - Navigation
มุมมอง 1482 หลายเดือนก่อน
how to extract Base peak chromatograms (BPCs), Extract ion chromatograms (EICs), instrument curves from data files.
MassHunter Qualitative Analysis Ep02 - Navigation and Extract ion chromatograms.
มุมมอง 3552 หลายเดือนก่อน
Extracting spectra, different ways of creating extracted ion chromatograms (EICs), subtracting background spectra, using the Mass caliper, Mass isotope calculator. Basic EIC extraction from MS/MS data files, basic fragment interpretation.
MassHunter Qualitative Analysis Ep01 - Basic Navigation
มุมมอง 4282 หลายเดือนก่อน
Qualitative Analysis - Ep01 - Navigation Part 1. Basic navigation, opening files, zooming, layouts, basic subtracting of spectra.
FIY: Fabricate It Yourself - Camera mount adapter (ONSHAPE part design, Cura slicing)
มุมมอง 646 หลายเดือนก่อน
Informative video on how to start fabricating a camera mount adapter that will repurpose existing action camera accessories. An M6 bolt is used instead of ¼” screw, as this was readily available. We delve into the Onshape part design and Cura slicing. See the link for the basic design in Onshape: cad.onshape.com/documents/1050dbd8a0cf5437b7817899/w/f9da46b6c147699889c8469b/e/72558fab94499ff4b72...
Openlabs CDS Chemstation installation configuration and licensing
มุมมอง 2Kปีที่แล้ว
How to install Openlab CDS Chemstation, configure an instrument, and load license
Qualitative LC MS HRMS Part 2 - Fragment confirmation for confidently confirming compounds
มุมมอง 248ปีที่แล้ว
A subsequent follow-on discussion of confirming MS/MS or fragmentation of diazepam in High Resolution Mass Spectrometry (HRMS).
Qualitative LC MS HRMS - interpreting mass accuracy and isotope patterns
มุมมอง 1.7Kปีที่แล้ว
Brief evaluation of LC-MS high resolution mass spectrometry (HRMS) data with discussions around mass accuracy (or error) and what we can infer from isotopologues.
Agilent LC-MS 6545 QTOF HILIC Target Suspect screening
มุมมอง 5622 ปีที่แล้ว
This video outlines the procedure to utilise Personal Compound Databases and Libraries (PCDL) to screen for compounds in a sample. The data was acquired using a Agilent 6545 QTOF in All Ions mode using normal phase chromatography on a HILIC-Z column.
Agilent 8890 GC-MS SIM Quant Data
มุมมอง 3.3K2 ปีที่แล้ว
Agilent 8890 GC-MS SIM Quant Data
Quantitative Analysis GCMS
มุมมอง 10K2 ปีที่แล้ว
Quantitative Analysis GCMS
Agilent 8890 GC MS Qualitative Analysis TMS derivatization
มุมมอง 1.7K2 ปีที่แล้ว
Agilent 8890 GC MS Qualitative Analysis TMS derivatization

ความคิดเห็น

  • @jorgecabrera9406
    @jorgecabrera9406 9 วันที่ผ่านมา

    Thanks for video, can you upload the carpet fot this chromatogram please

  • @syednoman3617
    @syednoman3617 2 หลายเดือนก่อน

    how do you choose qualifier and quantifier ions?

    • @openlabsolutions
      @openlabsolutions 2 หลายเดือนก่อน

      Typically we use the most abundant fragment as quantifier, it will be collision energy dependent, however it was optimized on your system. A qualifier is also carefully chosen not to interfere with other analogues or isomeric/isobaric species.

  • @komalhayat417
    @komalhayat417 4 หลายเดือนก่อน

    Is this some software? Because i do lcms that doesn't show such interface and options

  • @narthanaasenavarayan7564
    @narthanaasenavarayan7564 6 หลายเดือนก่อน

    Hi I have chromatography graph of lcms data but i cannot list out the compouds can you help me find it i am a Research Scholar

  • @ruthbarrientos9239
    @ruthbarrientos9239 ปีที่แล้ว

    Thank you so much 😊