- 8
- 73 581
StrucTech
India
เข้าร่วมเมื่อ 26 ม.ค. 2019
Structural analysis, ETABS,SAFE, Staad pro, RCDC, AutoCAD, design using excel and design of various other structures.
HIGH RISE BUILDING MODELING IN ETABS
Hello friends.,
in this video I have tried to show you how to do etabs modeling by using dxf
this is very fastest method to do etabs modeling for simple and complex geometry.
#fastest method to do etabs modeling
#etabs modeling
#building modeling in etabs
#building
#structural analysis in etabs
#HIGH RISE BUILDING IN ETABS
in this video I have tried to show you how to do etabs modeling by using dxf
this is very fastest method to do etabs modeling for simple and complex geometry.
#fastest method to do etabs modeling
#etabs modeling
#building modeling in etabs
#building
#structural analysis in etabs
#HIGH RISE BUILDING IN ETABS
มุมมอง: 1 998
วีดีโอ
ERROR WHILE IMPORTING ETABS TO RCDC
มุมมอง 2.5K2 ปีที่แล้ว
Hello Guys, I came across one problem while importing ETABS to rcdc so wanted to share the solution for same. #error while importing ETABS to rcdc #importing access file to rcdc #etabs to rcdc #general reading error #no value given for one or more parameters
Importing Etabs to RCDC
มุมมอง 1K2 ปีที่แล้ว
Hello Guys in this video I have shown how to import ETABS file to RCDC for designing structural elements #acces file to rcdc #etabs to rcdc
Staircase Design In Staad pro.
มุมมอง 6782 ปีที่แล้ว
In this video I tried explain how one can design a staircase using a staad pro. dog legged staircase staircase design using staad pro.
Seismic Analysis in staad
มุมมอง 7K4 ปีที่แล้ว
Hello Friends, This video will show u how to apply seismic/Earthquake force in staad pro. Cross checking results, validating staad pro. Results...100% results matched by manual and staad calculation... one mistake was there in excell due to which some difference was there in base shear..but i have corrected excel sheet so its matching 100% ..if u want please comment your mail id in mail box i w...
How to apply wind load in staad pro. correctly as per IS 875 Part 3: 2015
มุมมอง 43K5 ปีที่แล้ว
Hi friends check this must see video for wind load application in staad, as i have seen many applying wrong wind load. Mistakes done in load application. Please like subscribe and hit bell icon If you want this spreadsheet please comment your mail id i will mail it. Wind load calculation,excel sheet for wind load, spreadsheet for wind load,solidity ratio,force coefficient,cross checking wind by...
Design of RCC building in staad pro.
มุมมอง 15K5 ปีที่แล้ว
#StrucTechforstructures Design of G 2 storey building in staad pro., How to assign dead and live load in structural model (for wind and earthquake load i will make separate video).how to assign floor load, how to give beta angle, how to chane orientation of beam or column, What are the important design parameters to be given for designing a structure.
Modelling geometry in Staad pro.
มุมมอง 1.9K5 ปีที่แล้ว
#StrucTechforstructures Create node,create beam, translational repeat,mirror,circular repaete,strech, Staad editor, add beam by perpendicular option etc.
best staad analysis ever👍👍👍
Please provide excel sheet
Execellant Explanation
Plz provide me wind load Calculation sheet
Could you please share the autocad file
sir, In taking Cpe from table 5 i have one doubt. if the building is vertically rectangular front length side is A and opposite to that is C for 0 degree and in perpendicular for 90 degree, the top short side is B and bottom short side is D. accordingly we have to read cpe values from fig given in Table 5. if building is horizontally rectangular your front short side becomes B and opposite side is D for 90 and front length top and bottom side becomes A and C for 0 degree. is it correct to read cpe value. kindly clarify. nobody watch the figure given in table 5 to read cpe value. there is little comfusion in reading the figure.
Thanks for modaling sir. May you complete modal sir such as Analysis, Design And Detailing each member of High rise building
sir ploblem with importing etabs file to rcdc ... UNABLE TO READ ANALYSIS
well explained sir in your example u have considered wind in +ve x -direction how we have applying them in -ve x- direction please reply sir
Only change range and taken a factor negative
The option etabs database to access is inactive for me Even after installing access database 2016 it's not working Kindly help
Presentation is very cumbersome and boring. Make another excel sheet for calculating external and internal wind pressure by giving height, width input. And explain by giving text explanation as well and not switching too many times from one page to other.
how to apply gust factor
Hi...bro iam facing some problem during the run analysis
Please help! I have realized that when I release moments in staad pro secondary beams, RCDC is unable to read the correct beam length data. Also in instances where the beams meet without a column and/or grid line, RCDC throws excessive increase in the beam length. Please what could be causing this anomaly. A 3 meter beam in staad pro becoming 8 meters in RCDC is quite alarming
Generate হচ্ছে না
Please share the excell sheet
Can you provide this dxf file
Better than all the rest. Always move with backups and explanation. Keep it up.😁
Briliant.
Hai, any online classes for Stadd pro
Hi Nagaraju, I wish I could take classes but due to shortage of time it is not possible for me. Hope you guys understand
I've tried so much time to export the same from etabs but still, there is "UNABLE TO READ ANALYSIS FILE".I am using ETABS v19.1.0, RCDC v10.0.0 & Microsoft Office version is 2019 How to solve this error?
Can you share your etabs model
Same problem unable to read analysis data.
@@mohitmenaria2238 can you share your etabs file will check and revert
@@structech2535 i can share my etabs file please help
Sir How to check column/beam is safe or failure?
excel sheet
Sir shear me excel sheet wind and seismic also
Please share excell sheet
Will the approach remain same for Open Steel structure? or can we consider Wind in X only with 1 coefficient factor?
🙏🙏🙏
Sir you explained very clear and clarify all steps well that's why I hope all students understand easily
Cpe for wall "C" calculation is correct r wrong.. It is +0.8-(-0.2)=+1
Sir Please send the Excel sheet to my mail hariharalakshmanan@gmail.com
Please send me Excel sheet to my email id "newguest277@gmail.com" ASAP
Sir Please send me the spreadsheet to this mail. bhanuprakashckm@gmail.com
Sir staircase and foundation missing pls upload G+२ building design alalysis we need for project
Same thing can you show for pitched roof?
Study correctly and explain correctly. do not tend the viewer in total confusion. waste of time
Thanks sir..I need this..thank you very much
Dear Sudhir, Very good informative video. In your video I see that you have not considered the negetive values obtained in excel sheet while inputting values in wind load dilog box. Please clarify.thanks in advance
You have made such a nice video. Everything is very clear there. I request you to please upload a full detailed video over Response Spectrum Analysis in an Unsymmetrical RCC Structure. And please send me the Excel sheet of Wind load calculation and seismic load calculation. shivagupta0591@gmail.com Thanks
Hello Sir, very nice. thanks
Great video! Btw should we use the Cp values with an angle of 90° for WZ as well?
Very nice
So useful good clarity can you pls mail the spread sheet to space.makers@gmail.com
You are great! please share the excel with me. ascana1990@gmail.com
It is same for etabs software?
Sir isame jo height li h vo pure building ki li h ki floor ki li h ki windows ki li h ????
Sir, please kind to provide me the excel sheet?
you have explained so nicely. Excellent.
Please provide the IS code... Please brother
Hi friend,your video is very useful to learn many basic things.even if forget something just watching the video it can be refreshed.good job,if you don't mind please send me that excel sheet which you have prepared for generation of wind loads, my mail id is salimjohnp@gmail.com. thank you
Good work. Only thing is that the load is applied in +ve X direction only in this vedio. Do we need to apply all the four directions or +ve Z direction is sufficient. Anybody please clarify.