Condair / Nortec Steam Cylinders - Why Your Steam Cylinder Needs To Be Replaced
Jay shows what the inside of a new and used steam cylinder looks like and why they need to be replaced.
For more information, or to get replacement parts, visit us at
www.nortechumidifierparts.com
มุมมอง: 36

วีดีโอ

AprilAire Orifices Overview
มุมมอง 7873 หลายเดือนก่อน
Jay gives an overview of the different AprilAire orifices. For more information, or to get replacement parts, visit us at www.airqualityparts.com
Trion Bypass Style Humidifier Troubleshooting - Water Will Not Stop Running
มุมมอง 1197 หลายเดือนก่อน
Jay shows you how to diagnose a Trion bypass style humidifier that will not stop running water. For more information, or to get replacement parts, visit us at www.trionparts.com
Second Wind UV Systems - Overview
มุมมอง 727 หลายเดือนก่อน
Jay gives an overview of Second Wind UV systems. For more information, or to get replacement parts, visit us at www.secondwinduv.com
GeneralAire 1137 Humidifier Troubleshooting - Water Won't Stop Running
มุมมอง 2878 หลายเดือนก่อน
Jay shows you how to troubleshoot your GeneralAire 1137 fan powered humidifier that won't stop running. For more information, or to get replacement parts, visit us at www.generalaireparts.com
GeneralAire 1137 Fan Powered Humidifier Troubleshooting - Water Leaking
มุมมอง 7448 หลายเดือนก่อน
Jay shows you the possible causes of water leaking in a GeneralAire 1137 pan powered humidifier. For more information, or to get replacement parts, visit us at www.generalaireparts.com
Trion CD90 Dehumidifier Unit Controls Overview
มุมมอง 3210 หลายเดือนก่อน
Jay gives an overview of the controls for the Trion CD90 dehumidifier. For more information, or to get replacement parts, visit us at www.trionparts.com
Trion CD90 Dehumidifier Maintenance
มุมมอง 3910 หลายเดือนก่อน
Jay gives an overview of the maintenance required for a Trion CD90 dehumidifier. For more information, or to get replacement parts, visit us at www.trionparts.com
Trion CD90 Dehumidifier - Leveling and Drain Control
มุมมอง 2510 หลายเดือนก่อน
Jay shows you how to level the dehumidifier and make a drain connection. For more information, or to get replacement parts, visit us at www.trionparts.com
Trion CD90 Dehumidifier - Whole Home Configuration 2nd Method
มุมมอง 3710 หลายเดือนก่อน
Jay shows you what a whole home configuration for a Trion CD90 dehumidifier may look like in your home. For more information, or to get replacement parts, visit us at www.trionparts.com
Trion CD90 Dehumidifier - Whole Home Configuration 1st Method
มุมมอง 6210 หลายเดือนก่อน
Jay shows you what a whole home configuration for a Trion CD90 dehumidifier may look like in your home. For more information, or to get replacement parts, visit us at www.trionparts.com
Trion CD90 Dehumidifier - Standalone Configuration 2nd Method
มุมมอง 5110 หลายเดือนก่อน
Jay shows you what a standalone configuration for a Trion CD90 dehumidifier may look like in your home. For more information, or to get replacement parts, visit us at www.trionparts.com
Trion CD90 Dehumidifier - Standalone Configuration 1st Method
มุมมอง 7010 หลายเดือนก่อน
Jay shows you what a standalone configuration for a Trion CD90 dehumidifier may look like in your home. For more information, or to get replacement parts, visit us at www.trionparts.com
Trion CD90 Dehumidifier Overview
มุมมอง 5610 หลายเดือนก่อน
Jay gives an overview of the Trion CD90 dehumidifier. For more information, or to get replacement parts, visit us at www.trionparts.com
GeneralAire DH75 Dehumidifier - Whole Home Configuration
มุมมอง 47310 หลายเดือนก่อน
Jay shows you what a whole home installation for GeneralAire DH75 or DH100 dehumidifier looks like. For more information, or to get replacement parts, visit us at www.generalaireparts.com
GeneralAire DH75 Dehumidifier - Enclosed Space Installation
มุมมอง 9910 หลายเดือนก่อน
GeneralAire DH75 Dehumidifier - Enclosed Space Installation
GeneralAire DH75 Dehumidifier - How To Program
มุมมอง 8910 หลายเดือนก่อน
GeneralAire DH75 Dehumidifier - How To Program
GeneralAire DH75 Dehumidifier - Unboxing
มุมมอง 2010 หลายเดือนก่อน
GeneralAire DH75 Dehumidifier - Unboxing
GeneralAire DH75 Dehumidifier - Maintenance
มุมมอง 11610 หลายเดือนก่อน
GeneralAire DH75 Dehumidifier - Maintenance
GeneralAire DH75 Dehumidifier - Connecting to WIFI
มุมมอง 9510 หลายเดือนก่อน
GeneralAire DH75 Dehumidifier - Connecting to WIFI
Skuttle A01-0814-148 Solenoid Valve Assembly Overview
มุมมอง 7910 หลายเดือนก่อน
Skuttle A01-0814-148 Solenoid Valve Assembly Overview
Honeywell 50041883-002 Solenoid Valve Assembly Overview
มุมมอง 16810 หลายเดือนก่อน
Honeywell 50041883-002 Solenoid Valve Assembly Overview
Honeywell 50041883-001 Solenoid Valve Assembly Overview
มุมมอง 7810 หลายเดือนก่อน
Honeywell 50041883-001 Solenoid Valve Assembly Overview
Honeywell 50027997-001 Solenoid Valve Assembly Overview
มุมมอง 8010 หลายเดือนก่อน
Honeywell 50027997-001 Solenoid Valve Assembly Overview
Honeywell 32006444-001 Solenoid Valve Assembly Overview
มุมมอง 3210 หลายเดือนก่อน
Honeywell 32006444-001 Solenoid Valve Assembly Overview
Honeywell 32001876-001 Solenoid Valve Assembly Overview
มุมมอง 9710 หลายเดือนก่อน
Honeywell 32001876-001 Solenoid Valve Assembly Overview
Honeywell 32001639-002 Solenoid Valve Assembly Overview
มุมมอง 22710 หลายเดือนก่อน
Honeywell 32001639-002 Solenoid Valve Assembly Overview
Trion Air Flow Sensors Overview
มุมมอง 3910 หลายเดือนก่อน
Trion Air Flow Sensors Overview
Trion G-212 Solenoid Valve Overview
มุมมอง 1410 หลายเดือนก่อน
Trion G-212 Solenoid Valve Overview
Trion G-149 Solenoid Valve Overview
มุมมอง 1810 หลายเดือนก่อน
Trion G-149 Solenoid Valve Overview

ความคิดเห็น

  • @tauseefsiddiquicanada
    @tauseefsiddiquicanada 17 ชั่วโมงที่ผ่านมา

    Very good. Learned a lot.

  • @tauseefsiddiquicanada
    @tauseefsiddiquicanada 17 ชั่วโมงที่ผ่านมา

    Nice

  • @downhillskier989
    @downhillskier989 วันที่ผ่านมา

    When I go to test mode the humidifier on light flashes all the time, unit never kicks on

  • @jdub3561
    @jdub3561 2 วันที่ผ่านมา

    You don't show which direction the new filter goes. One side has two holes and the other side has a large opening.

  • @adrianbulfon8430
    @adrianbulfon8430 2 วันที่ผ่านมา

    Is there a rough flow rate that we would expect?

  • @schutzhund3933
    @schutzhund3933 4 วันที่ผ่านมา

    Can I replace the electric filter with a media filter instead?

  • @tsongojones2667
    @tsongojones2667 6 วันที่ผ่านมา

    Thanks! All of your videos are clear and complete and well produced. Helped me a lot with my Aprilaire 700 problems.

  • @johnmiller240
    @johnmiller240 7 วันที่ผ่านมา

    Your video skips the insertion (or verification) of the plastic screen filter into the new Solenoid.

    • @jayguliano3144
      @jayguliano3144 6 วันที่ผ่านมา

      A new solenoid valve ships with the strainer screen preinstalled.

    • @johnmiller240
      @johnmiller240 6 วันที่ผ่านมา

      Thanks for the info

  • @nublina09
    @nublina09 8 วันที่ผ่านมา

    Can I put a disposable air filter in this, if so does the button have to be on or off? I just moved into a new home and the button is on with a disposable filter. I went to remove it and shocked myself.

  • @TheSueb
    @TheSueb 8 วันที่ผ่านมา

    Thank you, great video!!

    • @jayguliano3144
      @jayguliano3144 8 วันที่ผ่านมา

      You are welcome. We spend a LOT of time generating these videos and work hard to make them consumable for homeowners and contractors alike.

  • @nephetula
    @nephetula 9 วันที่ผ่านมา

    Great video! But I think it's also good to mention the plastic inlet strainer, and the sintered bronze filter that's in the inlet side of most solenoid valves. If either of these gets clogged with rust, or calcium and lime, the flow through the valve can be impeded and you will think the solenoid valve isn't operating.

  • @EchoBravo2
    @EchoBravo2 12 วันที่ผ่านมา

    @OnTimeMall thanks for sharing the info! In 3:00 you mentioned that if too much water going out of solenoid valve, it could overflow the pad and cause leakage. Is a very high water pressure going into the solenoid valve can also cause the leakage or the solenoid valve able to suppress the pressure? I have a SharkBite with a tap to control the water pressure.

    • @jayguliano3144
      @jayguliano3144 12 วันที่ผ่านมา

      The replaceable nylon orifice controls the water volume. This is talked about at 2:52 in the video. High water pressure going to the solenoid valve is not usually an issue. You don't regulate the water volume with a hand valve ahead of the humidifier.

  • @SpockLogic66
    @SpockLogic66 16 วันที่ผ่านมา

    You explained the procedure perfectly. Also, the video shots were clear and easy to follow. No wasted words; just a concise tutorial. Well done!

  • @cubsmyers7471
    @cubsmyers7471 16 วันที่ผ่านมา

    The air cleaner control was not working on my Aprilaire 5000 Model 501, I found one and replaced. It sill is not coming on. The blue light does come on, and was on before I replaced it. Any ideas on why the Air Cleaner Control is not coming on?

    • @jayguliano3144
      @jayguliano3144 16 วันที่ผ่านมา

      That digital display is now obsolete. If your issue is the digital display, we cant help you. If the indicator light on the air cleaner is not on, watch the video a couple of times to determine if the problem is with the door or the filter frame.

  • @mrpickle23
    @mrpickle23 17 วันที่ผ่านมา

    it always leaks.. no matter what you do or replace.. which is why hvac companies stopped installing these -- they always leak and fail

  • @chicagowsox212
    @chicagowsox212 18 วันที่ผ่านมา

    I noticed my frame has a pretty big amount of space at the top and it seems like water is splashing up and running down the access panel door and then leaking out and rusting the door screw. I pushed the frame up as high as it will go while still having the bottom connect into the drain. Fingers crossed because this is getting annoying. I also turned the water supply valve down (closed it a little) to try to slow the water pressure down

    • @Jayguliano
      @Jayguliano 17 วันที่ผ่านมา

      Water volume is regulated by an orifice at the solenoid valve. You don’t control it with your hand valve. It’s common for the feed hose to spring a leak as well. The drain should have a trickle of water running down it that is just above a drip. It should not run out like a garden hose. The pad frame should fit fairly close. Orifices do wear out over time and plug or get larger and allow too much water to flow

  • @chicagowsox212
    @chicagowsox212 18 วันที่ผ่านมา

    Thanks for the vid. Mine has been leaking out of the front door panel. Seems like water pressure is too high but it wasn’t too high when it was installed about 14 months ago. I change the pad 3 times per winter due to a lot of lime in the water. Even with a fresh pad it’s dripping out and the screw that holds the door on is all rusty. I’ve tried to turn the water pressure down. That helps a little but not all the way. Drain tubing is clear and free. So annoying!!!

    • @Jayguliano
      @Jayguliano 17 วันที่ผ่านมา

      It’s possible for water pressure to change. Water pressure in the winter are often higher since no one is watering the plants or washing their cars in the driveway. A whole house pressure regulator solves that issue.

    • @chicagowsox212
      @chicagowsox212 17 วันที่ผ่านมา

      @@Jaygulianooh man thank u for that. This is driving me crazy. I knew something was wrong when it started leaking. You wouldn’t believe how much lime our city well water has. I wonder if the part is bad that u were just talking about. Could clogging of the solenoid cause too much water pressure?

    • @mrpickle23
      @mrpickle23 17 วันที่ผ่านมา

      same here// no clue what to do

  • @bryang9601
    @bryang9601 20 วันที่ผ่านมา

    Wow! Best instructional and trouble shooting video on TH-cam.

  • @jayguliano3144
    @jayguliano3144 20 วันที่ผ่านมา

    Watch the video several times. You either have an orifice that needs to be replaced because the hole in it is too large, a cracked feed tube, or the internals inside the cabinet are not assembled correctly. Pull the cover off and look inside, like in the video, to ensure it is correctly assembled and the feed tube is connected at the top. Most of the time, the problem is a cracked feed tube.

  • @joeellerbach2095
    @joeellerbach2095 20 วันที่ผ่านมา

    Great video, my 760 is leaking at the bottom. Sounds like it is probably allowing too much water through the orifice

  • @castleranch738
    @castleranch738 21 วันที่ผ่านมา

    My goodness…one of the best instructional videos on TH-cam! We recently purchased a home that has one of these but when we opened, there was nothing inside except for the two mesh pre-filters. How can we go about finding out what we need in order to benefit from having this unit? Thank you in advance!

  • @larrybrown2470
    @larrybrown2470 22 วันที่ผ่านมา

    Thank you for the detailed instructions. A friend of mine passed away and when I talked to his daughter she said she hadn’t changed the furnace filter. When I went over to look at it I found a Bryant electronic air cleaner. I had no idea what to do with it until I washed your video.

    • @Jayguliano
      @Jayguliano 22 วันที่ผ่านมา

      Fantastic we are glad to help.

  • @prawnis
    @prawnis 22 วันที่ผ่านมา

    thx skibby

  • @chon_jung
    @chon_jung 22 วันที่ผ่านมา

    Simple and straightforward. Thank you

  • @Stangmaster
    @Stangmaster 24 วันที่ผ่านมา

    Saddle valves go against building codes, and will not pass home inspection. Insurance may not cover water damage caused by valve failure.

  • @Stangmaster
    @Stangmaster 24 วันที่ผ่านมา

    Saddle valves go against building codes, and will not pass home inspection. Insurance may not cover water damage caused by valve failure.

  • @user-my4px4tg2q
    @user-my4px4tg2q 26 วันที่ผ่านมา

    Does the rotating direction matter? Thanks.

    • @Jayguliano
      @Jayguliano 26 วันที่ผ่านมา

      No The motor often changes direction each time it restarts.

  • @gearhead-do1xh
    @gearhead-do1xh 28 วันที่ผ่านมา

    Hi great video. My honeywell seems to only run water between 0 and 25‰ on the dial then it turns off. Did they install the humidistat correctly? I thought I should be able to turn it higher and hear the click/water turn on at my desired humidity?

    • @Jayguliano
      @Jayguliano 27 วันที่ผ่านมา

      There are 3 terminals on most analog duct mount humidistats. If your unit never worked properly they may have used the wrong 2 terminals. One is common, one is normally open and the other is normally closed. Basically one is common, one is for a dehumidifier and one is for a humidifier.

  • @fitzpatrickgf
    @fitzpatrickgf 29 วันที่ผ่านมา

    Hello! I have an old Allied Products Division of Carrier Corp. Electronic Air Cleaner, similar to the one you have. I purchased my home in 2016 and all the inner cells and pre-filters were missing from the unit. The power was disconnected from the unit to the furnace , but I was able to get a few wires reconnected to see the power light did come back on. I was first considering buying a whole new updated unit, but if it was possible to track down replacement cells and prefilter parts, would you have any ideas where I could find these parts? The inside cover shows it as a Listed Electrostatic Air Cleaner 472H Model: 313X114100. Product: 313X114101 Serial# U751417. Other numbers listed 2-04602 H . If I don't see a response, I'll try the number you have listed. Thank You!

    • @jayguliano3144
      @jayguliano3144 29 วันที่ผ่านมา

      It became too difficult to deal with Carrier for air cleaner parts, so we dropped this product line. There are a few Carrier air cleaner parts on our site, but Carrier obsoleted many of these products. If it were my home, I would replace the unit. As the units got older, the cost of the Carrier brand parts went through the roof for the few items that were still available.

    • @fitzpatrickgf
      @fitzpatrickgf 29 วันที่ผ่านมา

      @@jayguliano3144 One more question? Are there still these types of Electromagnetic Cleaners with internal cells and pre-filters made by the products you sell or another manufacturer that I can possibly swap out for a new one? I'm not so sure about the Electronic Air Cleaners with the big filters on them, due to the higher air flow restriction causing more run time, wear and tear on the furnace and A/C. It would seem like the Cell type filters had a better air flow to them.

  • @richardc8129
    @richardc8129 29 วันที่ผ่านมา

    Where can I get the Manual Mode resistor for the AprilAire 700 or 700M?

    • @jayguliano3144
      @jayguliano3144 29 วันที่ผ่านมา

      That item has gone obsolete, and we don't have any left in stock. The resistor was roughly 46,000 ohms, so you should be able to buy a ressiter on the internet to use as a substitute.

  • @akautocollisionltd.7480
    @akautocollisionltd.7480 หลายเดือนก่อน

    Great video

  • @rbusky
    @rbusky หลายเดือนก่อน

    Great video, thanks!

  • @glennhutchinson3227
    @glennhutchinson3227 หลายเดือนก่อน

    why didn't you just take the front cover off to access the solenoid wiring inside there?

    • @jayguliano3144
      @jayguliano3144 หลายเดือนก่อน

      When you remove the cover the power to the solenoid valve is disconnected. There is a plug built into the cover that connects to those yellow wires.

  • @deann2609
    @deann2609 หลายเดือนก่อน

    Very good video - if you have an online store, you should put links to the parts in the transcript

  • @teshomewondafrash5312
    @teshomewondafrash5312 หลายเดือนก่อน

    Enviroaire whole house humidifier replacing the water pad

  • @HeatherBryant-rj4sq
    @HeatherBryant-rj4sq หลายเดือนก่อน

    Which side does the air filter go on?

    • @jayguliano3144
      @jayguliano3144 หลายเดือนก่อน

      If you are asking about the aluminum mesh prefilter it goes on the end opposite the furnace. If you watch the video carefully, I mention the direction of the airflow. Air goes through the prefilter, then the collector cells, then the post filters (if there are any), and then into the furnace.

  • @Rudolph-h7b
    @Rudolph-h7b หลายเดือนก่อน

    Thanks for your video. Helped out alot!

  • @Jayguliano
    @Jayguliano หลายเดือนก่อน

    It sounds like it’s wired wrong. It should only get power when the furnace blower is running and the humidistat is calling for humidity at the same time

  • @KhusbirsinghVij
    @KhusbirsinghVij หลายเดือนก่อน

    Air water purifier magnet jewellerly made electronic clean Ozone features fresh air so many uses multi use product

  • @dippitydoinit
    @dippitydoinit หลายเดือนก่อน

    I messed with my unit for 2 hours trying to figure out why it wasn't turning on the water. The only thing I can figure is the humidistat is bad.

    • @jayguliano3144
      @jayguliano3144 หลายเดือนก่อน

      If you have a volt meter, you can test for roughly 24 Volts of AC power coming out of the humidistat headed to the humidifier. It should absolutely work in test mode to run the humidifier. There are more videos on our website that you can find based on your humidifier model number that MIGHT help you further.

    • @dippitydoinit
      @dippitydoinit หลายเดือนก่อน

      @@jayguliano3144 Thanks. I tested and I was not getting voltage to the valve but that's because the unit isn't telling it to turn on. I got the unit to work randomly while frantically turning the knob from test to off repeatedly. It turned the water on once but hasn't worked since.

  • @amccargo9809
    @amccargo9809 หลายเดือนก่อน

    my unit is running even when the furnace is stop

  • @MinneapolisDavid
    @MinneapolisDavid หลายเดือนก่อน

    Now show us how to hook up the outdoor sensor. 10,000 videos on the device but not how to install the temp sensor.

    • @jayguliano3144
      @jayguliano3144 หลายเดือนก่อน

      The temp sensor is mounted outdoors. Installation is a matter of drilling a 3/16-inch hole through the wall, mounting it at that hole, pushing the wire through the wall, and caulking the hole. The sensor needs to be high enough so as to not be buried in snow. Preferably on the North side of your home so it's not hit by the sun much. Some installers drill a small hole in the side of the fresh air duct going to their 90% efficiency furnaces and push the sensor into that hole. They then put a hose clamp around the pipe to hold it into place. The wire from the sensor can be easily extended to any reasonable length using bell wire. There is nothing special about the sensor wire.

  • @brianc4629
    @brianc4629 หลายเดือนก่อน

    Great video - thank you!

  • @whitebear6213
    @whitebear6213 หลายเดือนก่อน

    What type of post filter is recommended

  • @onjisan
    @onjisan หลายเดือนก่อน

    Thanks for this! I was researching how to get a new replacement inside cabinet part since all of the plastic clips were breaking off when I ran across this replacement option! Will be getting one asap!

  • @Rocky-xx2zg
    @Rocky-xx2zg หลายเดือนก่อน

    A Challenge to wire correctly. JMO

    • @jayguliano3144
      @jayguliano3144 หลายเดือนก่อน

      This control needs power 24/7 so it does wire differently than the basic analog-style humidistat.

    • @Rocky-xx2zg
      @Rocky-xx2zg หลายเดือนก่อน

      @@jayguliano3144 I saw that Jay. And I see where the Outdoor Temp wires need to be attached. But, It has added slots than my old 768 that I'm not familiar. I don't know were to find the wires source to place in the slots. I'll have to call in a Pro. I did not expect this, I thought it would be a ' one for one' replacement.

  • @GeorgeSewell-r6w
    @GeorgeSewell-r6w หลายเดือนก่อน

    What a great video. After watching hundreds of repair videos on a wide variety of topics, I think this is the best one I have ever seen. I now know what to look for in humidifier that is leaking water out the bottom.

    • @jayguliano3144
      @jayguliano3144 หลายเดือนก่อน

      Thanks, We spend a lot of time and money to create help videos that are consumable for homeowners and technicians. It takes hours to generate each minute of video.

  • @knarefyi6793
    @knarefyi6793 หลายเดือนก่อน

    Great video but most probably it’s a lime scale block- take the solenoid apart along with the top pipe and soak in vinegar for a few hours/ overnight. It will fix the issue. I think the power test is redundant. Stand near the humidifier and switch off the system, switch it back on at the highest humidity setting- if you hear a click- the solenoid is working if not, you know it has to be replaced.

    • @jayguliano3144
      @jayguliano3144 หลายเดือนก่อน

      We never recommend taking the solenoid apart since there are a collection of small pieces inside it. Some models can not be taken apart. Some seals, gaskets, and O rings inside certain valves do not reseal properly after they have aged.

    • @joshmcca
      @joshmcca หลายเดือนก่อน

      @@jayguliano3144so just buy another one?

  • @megieslamin3193
    @megieslamin3193 หลายเดือนก่อน

    great video. Thank you!! Question - if cells are still a bit damp, will light be off even if unit turned on?

    • @jayguliano3144
      @jayguliano3144 หลายเดือนก่อน

      When the cells are wet the unit will be shorted out and will not operate properly. The light will not be on and it may make snapping sounds.

    • @bradjames5184
      @bradjames5184 หลายเดือนก่อน

      Yes give it some time. Run the unit with the filter off for awhile to help dry the before using it

  • @martinlord8837
    @martinlord8837 หลายเดือนก่อน

    For someone with the above setup, is MERV 11 appropriate or should we stick with MERV 8? Filtering smaller particles with MERV 11 is all good for air quality but if reduces air flow it may not be worth it.