IES, Inc. iesweb.com
IES, Inc. iesweb.com
  • 216
  • 219 052
VF: Version 13 Upgrade Guide
VisualFoundation 13 introduces a variety of new features, including enhanced punching shear design and updates to bearing pressure calculations. Additionally, new design specifications, load combinations, and scripting commands have been implemented, as explained in this video.
▬▬ Contents of this video ▬▬
0:00 - Intro
0:12 - Punching Shear
1:12 - Group Punching Shear
1:57 - Bearing Pressure
3:01 - ACI 350
3:26 - Neglect Size Effects
3:50 - AISC 360-22
4:03 - Area Reduction Factor
4:58 - IBC 2024 & NBC 2020
5:21 - New Script Commands
6:24 - Outro
มุมมอง: 113

วีดีโอ

VF: Punching Shear Design
มุมมอง 3321 วันที่ผ่านมา
Punching shear design checks are performed at locations where concentrated loads are introduced into the foundation slab, such as at piles, column piers, and walls. VisualFoundation can perform unreinforced punching shear checks for individual objects, as discussed in this training video.
VF: Group Punching Shear Design
มุมมอง 3921 วันที่ผ่านมา
In VisualFoundation, punching shear checks are performed at locations where concentrated loads are applied to the foundation slab, such as piles, column piers, and walls. When these elements are spaced closer than the slab thickness, VisualFoundation combines them into a punching shear group. The punching shear design may be governed by either the main group or a subgroup, as explained in this ...
VF: ACI 350 Design
มุมมอง 4821 วันที่ผ่านมา
This video provides an overview of how to design environmental concrete structures according to the ACI 350 design specification in VisualFoundation.
VF: New Script Commands
มุมมอง 2021 วันที่ผ่านมา
VisualFoundation 13 includes various new script commands, discussed and demonstrated in this training video. A complete list of available script commands is found in help file. For more advanced programming, use external scripts, read into program as explained in external scripts training video. ▬▬ Contents of this video ▬▬ 0:00 - Intro 0:23 - Set Project Criteria 0:51 - Delete Loads 1:35 - Cus...
Transfer a Network License using ManageIT
มุมมอง 294 หลายเดือนก่อน
This video outlines the steps required to transfer a Network license from share directory to another using the ManageIT utility.
Activate a Network License using ManageIT
มุมมอง 444 หลายเดือนก่อน
This video outlines the steps to activate a network license using the ManageIT utility.
Transfer Single-User License
มุมมอง 234 หลายเดือนก่อน
This video outlines the steps required to transfer a Single-User license from one computer to another.
Activate Single-User License
มุมมอง 484 หลายเดือนก่อน
This video outlines where to locate your License ID and Activation Password within your Customer Portal and how to activate your Single-User license.
VA: Version 23 Upgrade Guide
มุมมอง 3635 หลายเดือนก่อน
Several new scripting, modeling, loading, analysis, design, and reporting features have been added to VisualAnalysis 23 which are discussed in this video. ▬▬ Contents of this video ▬▬ 0:00 - Intro 0:11 Script Design Commands 2:21 External Design Scripts 3:11 New Connections Export 3:33 New Building Codes 4:03 Design Selection Window 4:19 SDNF Import & Export 4:35 Copy Vertices 4:58 One-Way Rota...
VX: Version 7 Upgrade Guide
มุมมอง 1266 หลายเดือนก่อน
In VAConnect 7.0, three new connections have been added, existing connections have been improved, and the steel and concrete design specifications have been updated. ▬▬ Contents of this video ▬▬ 0:00 - Intro 0:11 - Startup Screen 0:43 - Update Design Specifications 1:39 - Double Angle Bolted Welded 2:48 - Double Angle Welded 4:04 - Double Angle Welded Bolted 5:09 - Connection Improvements 6:03 ...
VX: Double Angle Welded Bolted Design
มุมมอง 1076 หลายเดือนก่อน
Double Angle Welded Bolted connections are designed per the AISC 360 design specification and per the AISC Steel Construction Manual Part 10. In accordance with AISC part 10, the eccentricity on the supported side of the double-angle connection (i.e. the beam side) is neglected when a single vertical row of bolts through the beam does not exceed a distance of 3 inches from the face of the suppo...
VX: Double Angle Welded Design
มุมมอง 756 หลายเดือนก่อน
Double Angle Welded connections are designed per the AISC 360 design specification and per the AISC Steel Construction Manual Part 10. In accordance with AISC part 10, the eccentricity on the supported side of the double-angle connection (i.e. the beam side) is always considered since the double angles are welded to the beam. Furthermore, VAConnect accounts for the weld eccentricity on the supp...
VX: Double Angle Bolted Welded Design
มุมมอง 1036 หลายเดือนก่อน
Double Angle Bolted Welded connections are designed per the AISC 360 design specification and per the AISC Steel Construction Manual Part 10 & Part 12. In accordance with AISC part 10, the eccentricity on the supported side of the double-angle connection (i.e. the beam side) is always considered since the double angles are welded to the beam. Double Angle Bolted Welded connections can be design...
VX: Shear Tab & Double Angle Updates
มุมมอง 516 หลายเดือนก่อน
This video discusses the updates and improvements that have been made to the shear tab and double angle connections in VAConnect Version 7.
VARevitLink 22
มุมมอง 20711 หลายเดือนก่อน
VARevitLink 22
SB: Version 14 Upgrade Guide
มุมมอง 330ปีที่แล้ว
SB: Version 14 Upgrade Guide
CB: Version 7 Upgrade Guide
มุมมอง 205ปีที่แล้ว
CB: Version 7 Upgrade Guide
CB: External Scripts
มุมมอง 56ปีที่แล้ว
CB: External Scripts
CB: Script Command Line Basics
มุมมอง 118ปีที่แล้ว
CB: Script Command Line Basics
VA: Version 22 Upgrade Guide
มุมมอง 741ปีที่แล้ว
VA: Version 22 Upgrade Guide
VF: Version 12 Upgrade Guide
มุมมอง 368ปีที่แล้ว
VF: Version 12 Upgrade Guide
VF: Script Command Line Basics
มุมมอง 152ปีที่แล้ว
VF: Script Command Line Basics
VF: External Scripts
มุมมอง 113ปีที่แล้ว
VF: External Scripts
VF: Plate Diagrams
มุมมอง 188ปีที่แล้ว
VF: Plate Diagrams
VX: Version 6 Upgrade Guide
มุมมอง 1752 ปีที่แล้ว
VX: Version 6 Upgrade Guide
VX: Double Angle Bolted Design
มุมมอง 8352 ปีที่แล้ว
VX: Double Angle Bolted Design
VX: Stiffened Bolted End Plate Design
มุมมอง 3472 ปีที่แล้ว
VX: Stiffened Bolted End Plate Design
VX: Column Splice Design
มุมมอง 5352 ปีที่แล้ว
VX: Column Splice Design
VX: Beam Over HSS Design
มุมมอง 7212 ปีที่แล้ว
VX: Beam Over HSS Design

ความคิดเห็น

  • @Dorilio
    @Dorilio 2 หลายเดือนก่อน

    Hello, I have the error "There are no load combinations that match the design group's "specification" (ASD vs. LRFD) parameter. Please edit the design group's parameter or use the load case manager to edit the load combinations." I already tried to put "custom" in my load combinations but it doesn't fix it, can you help me solve it?

  • @SayedMujeeb-t7d
    @SayedMujeeb-t7d 3 หลายเดือนก่อน

    PLEASE ADD BRITISH CODES ALSO

  • @AchourSoumia-nx5hm
    @AchourSoumia-nx5hm 10 หลายเดือนก่อน

    Xwozianvgmsglh

  • @MrSimsek34
    @MrSimsek34 ปีที่แล้ว

    How to assign a flexible diaphragm in VA. thank you

  • @andymiller9859
    @andymiller9859 ปีที่แล้ว

    Can this be modeled in Visual Analysis and associated loads exported into VA Connect?

  • @strosa2406
    @strosa2406 ปีที่แล้ว

    Does your software support SI units?

  • @schex9
    @schex9 ปีที่แล้ว

    How do we add a Moving Load Case to a Custom Load Combination?

  • @josephpatrick384
    @josephpatrick384 2 ปีที่แล้ว

    🤗 þrðmð§m

  • @الفنانالحقيقي
    @الفنانالحقيقي 2 ปีที่แล้ว

    how could i get this software?

  • @edyquintana3179
    @edyquintana3179 2 ปีที่แล้ว

    Complicated issue in this software, I use other analysis software but this software is not practical on the load issue. Tema complicado en este software, yo utilizo otros softwares de analisis pero este software no es practico el tema de las cargas.

  • @Struct2009
    @Struct2009 2 ปีที่แล้ว

    a split area command would be helpful.

  • @Struct2009
    @Struct2009 2 ปีที่แล้ว

    Will it show wood armer moments?

  • @alevzanderg
    @alevzanderg 3 ปีที่แล้ว

    exelente

  • @roberthaley4224
    @roberthaley4224 3 ปีที่แล้ว

    How to the checks and calculations change when you add a thermal break in between the end plate and column?

  • @DVain
    @DVain 3 ปีที่แล้ว

    I had an issue when I imported a light-gauge shape from shapebuilder into VA and the Design of the model wouldn't work. The model was stable but it would just say the member is "Not Checked" Edit: Looks like I have to choose a "Design Type" that isn't "Analysis Blob" when exporting Edit2: But there are no Design Types that match a built-up light-gauge shape

  • @emadnadi5206
    @emadnadi5206 4 ปีที่แล้ว

    no out of plane ??????

  • @sadida1748
    @sadida1748 4 ปีที่แล้ว

    is there any explanation of buckling that may happen in composite beam?

    • @DomaineStickem
      @DomaineStickem 3 ปีที่แล้ว

      Buckling shouldn't occur until after the composite beam has been loaded beyond capacity right? And design plays a pretty strong factor in ensuring buckling doesn't occur at all. Everything from the strength of concrete, the number/size of anchors, steel bean selection and tributary width plays a crucial role. Check AISC 10th edition chapter 3 for details on composite beam moment capacity and anchor strength