Testando o sistema de combate à incêndio hidrantes
มุมมอง 21K6 ปีที่แล้ว
METAL SERVICE MANUTENÇÃO INDUSTRIAL e instalação de sistemas de combate à incêndio hidrantes spliker e centrais
METAL SERVICE MANUTENÇÃO INDUSTRIAL CONTATO 16 992850619.ZAP OU 993832802
มุมมอง 276 ปีที่แล้ว
METAL SERVICE MANUTENÇÃO industrial
Title
มุมมอง 16 ปีที่แล้ว
Created by VideoShow:videoshowapp.com/free
23 de janeiro de 2018
มุมมอง 157 ปีที่แล้ว
23 de janeiro de 2018
Fogão alenha
มุมมอง 57 ปีที่แล้ว
Fogão alenha
METAL SERVICE. serviços de manutenção predial industrial
มุมมอง 627 ปีที่แล้ว
Created by VideoShow:videoshowapp.com/free

ความคิดเห็น

  • @taynaraoliveira1283
    @taynaraoliveira1283 ปีที่แล้ว

    Vídeo muito bom, melhor que isso só dois disso rsr

  • @paulocesar7620
    @paulocesar7620 2 ปีที่แล้ว

    Opa , amigo se eu regula o presostato da bomba jokei pra ligar com 2 kilos e desliga com 4kilos qual seria a regulagem do presostato da bomba principal para ela entrar quando abrir a mangueira e desligar quando eu fecha a mangueira

  • @GuilhermeDias-ys6pw
    @GuilhermeDias-ys6pw 3 ปีที่แล้ว

    Belo trabalho, apenas uma observação: a válvula de retenção de 2 1/2'' utilizada nesta instalação está incorreta. Existem dois tipos de válvulas, as que são utilizadas em trechos horizontais e as utilizadas em trechos verticais. Neste caso o correto seria a utilização de válvula de retenção vertical.

    • @andrebaggio1034
      @andrebaggio1034 3 ปีที่แล้ว

      Concordo com você Guilherme!! eu que trabalho com laudos de sistemas preventivos, nessa situação já ia sugerir uma adequação no sistema.

  • @laurapiris862
    @laurapiris862 3 ปีที่แล้ว

    Ótima explicação

  • @sergioaraujo7808
    @sergioaraujo7808 3 ปีที่แล้ว

    Passe o esqiem deste sistema.

  • @casafepattybielclarisse7223
    @casafepattybielclarisse7223 3 ปีที่แล้ว

    O cavalete de Bomba segundo a IT22, deve ser conforme item C.2 da mesma IT, desta forma que esta feito como faz pra testar individualmente as bombas? é possivel?

  • @Pitbullabpt
    @Pitbullabpt 3 ปีที่แล้ว

    Amigo ele tem que ta ligado direto no automático?

    • @jogadorlivre
      @jogadorlivre ปีที่แล้ว

      O correto é estar ligado no automático pra fazer esse monitoramento, mas se necessário (teste ou falha) pode ativar no modo manual

  • @renansantos3491
    @renansantos3491 4 ปีที่แล้ว

    E se não tiver água na bomba faz o que?

    • @jogadorlivre
      @jogadorlivre ปีที่แล้ว

      com a instalação de uma chave de fluxo, o motor desliga

  • @lucinacruz3592
    @lucinacruz3592 4 ปีที่แล้ว

    Olá Se a casa de bomba estiver com algum problema e sempre ficar no manual Quando tiver algum sinistro Ela vai demorar pra entrar em combate?

    • @MrMarquinho33
      @MrMarquinho33 3 ปีที่แล้ว

      Lucina no caso da bomba estiver no manual, ela terá que ser acionada pelo o bombeiro ou brigadista uma vez que esta se encontra no modo manual dependendo de um acionamento externo, a orientação é tanto a principal quanto a jockey permaneçam no automático ok espero ter ajudado

  • @juliocesarfernandesteixeir3040
    @juliocesarfernandesteixeir3040 5 ปีที่แล้ว

    Bacana

  • @sanchez8023
    @sanchez8023 5 ปีที่แล้ว

    Excelente explicação, de forma simples porém o conteúdo foi muito bom, pena que a camera as vezes mudou de posição, sei da dificuldade de filmar e manusear as válvulas, mas tirando esse detalhe a nota é 9,5, parabéns, quanto ao desligamento automático da bomba principal realmente é ideal desligar de forma automática, porém em alguns casos tem que desligar manualmente, a legislação de SP exige, sabendo do risco que poderá causar caso ninguém a desligue. obrigado parabens

  • @michaelfelipe9044
    @michaelfelipe9044 5 ปีที่แล้ว

    seu numero

  • @2217Jonathan
    @2217Jonathan 5 ปีที่แล้ว

    O desligamento da bomba principal não deve ser só manual no painel da bomba?

    • @lucasperes4394
      @lucasperes4394 5 ปีที่แล้ว

      Não, pois quando se termina o combate ao incêndio a pressão na rede tem que subir automaticamente pq volta a fechar a rede. Se não tem ninguém utilizando a rede a pressão se manterá subindo até que ocorra falha na bomba, caso não desligue automaticamente, por isso a bomba desliga sozinha quando a pressão chega em determinada pressão, sendo feito o controle por meio do pressostato.

    • @casafepattybielclarisse7223
      @casafepattybielclarisse7223 3 ปีที่แล้ว

      @@lucasperes4394 Segundo a IT 22- CBMSP de SP, seguindo o item C.1.15.2 As automatizações da bomba de pressurização (jockey) para ligá-la e desligá-la automaticamente e da bomba principal para somente ligá-la automaticamente devem ser feitas através de pressostatos instalados conforme apresentado na Figura C.2, e ligados nos painéis de comando e chaves de partida dos motores de cada bomba. A bomba de Combate ou como conhecida principal, deve apenas ligar de forma automática e não desligar!

    • @AndreSantos-ho5pp
      @AndreSantos-ho5pp 2 ปีที่แล้ว

      Verdade

    • @allangarcia9014
      @allangarcia9014 ปีที่แล้ว

      @@casafepattybielclarisse7223 " e desligados nos painéis..."