Repair Automation Products And Electronic Products
เข้าร่วมเมื่อ 13 ม.ค. 2017
Burada çeşitli elektronik ve otomasyon ürünlerinin tamir ve çalışma videoları olacaktır
วีดีโอ
#DELTA_VFD_B_SERIES #MOTOR #DRIVER #OCC_FAULT
มุมมอง 4764 ปีที่แล้ว
#DELTA_VFD_B_SERIES #MOTOR #DRIVER #OCC_FAULT
#Delta_A2_4_5_kW_servo_driver_AL01_fault
มุมมอง 5154 ปีที่แล้ว
Igbt modülü değişimi,AL01 hatası araştırma esnasında,ilk motor sargıları ölçülür daha sonra kablo kontrolü emin olunduktan sonra driver kısmında ölçümler yapılarak hata tespit edilir.
#Delta #A2 #Servo #Repaired Ale 01 part 2
มุมมอง 3.8K5 ปีที่แล้ว
#Delta #A2 #Servo #Repaired Ale 01 part 2
#Delta #A2 #servo #drivers #ALE01 FAULT Part 3
มุมมอง 2.1K5 ปีที่แล้ว
#Delta #A2 #servo #drivers #ALE01 FAULT Part 3
i have some case alarm AL001, but i cant find dioda DZD83 on mother board, at my mother board just find dd83, its same or no, please reply my comment
Can you help me
Yes, listen to you
Merhaba güç kartının arka tarafında bulunan dd13 diyotunun karşısındaki r207 ile baslayan aşağıya doğru 3 adet olan smd dirençlerin değerleri yandığı için okunmyor yardımcı olabilirmisiniz?
I have a problem E 02 with 3kw servo same model delta A2 I can't handle it. Can you help me?
E 02 , low voltage ör high voltage fault, i dont remember it, i return to you, ok
How to fix error 02
in4733 is also okey to put?
İt must be 18volts zenerdiode
Num ji
Cau you help me
Wellcome listen to you
Yes
@@repairautomationproductsan3576 i have servo delta asd-a2-0421-mn alarm al001 I can't find any thing
@@MahmoudAhmed-i4eigbt module control please
Hi sir ... I m have issue with B2 ... Al001 ...
Hi sorry for late answer, The igbt module changed İts problem solved
Sir , i have delta A2 servo drive 100watt and alarm AL001, is it zener diode problem? Or other component?
Hi.If there is no short circuit in the trigger pins of the IGBT module, the DZD83 zener diode on the main board needs to be replaced.
Sir pls help delta A2 1.5 kw power supply is on display alarm 06 show what is the reson in power card control card already change but reson same
Sorry control card change but error same show
@@ServoVFDlocha Have you tried it with another engine?
alarm 06 and alarm 09 are faults caused by the encoder of the motor. I think the servo drive is solid in my experience
Encoder checking please
Without encoder cable connect and power cable uvw show 06 alarm
Pls help delta a2 drive some time ok working and them power supply off wait 2 mint and drive power supply on alarm 01 show what is the reason
For the al001 alarm, first of all, if the IGBT is solid, DZD41 zenerdiode on the power bd, if not, change the pc929 optocouplers, but most importantly, try with another CPU bd and start changing the components.ok
I have already changed pc929, 7840and igbt my drive model is asd-a2-0721-u 750 watt dzd41 diode not found in power card
Can you give me your e-mail address, I have a power board with 721-m extension, I can explain it through it, ok
Not DZD41 ,,İT MUST BE DZD83 🆗
Ok Tks
Hi
Hi friends
@@repairautomationproductsan3576 yes I have AL003 Servo motor. Asd a2-3023m.
I'm listening you
@@bunpisith Lowe voltage alarm , isn't it
@@bunpisith The DC bus capacitors and the IGBT module are probably bad
Pls contact Whatsapp number
Delta ASD A2 7543-M servo drive ALARM AL001 pls help repair parts name send
Delta ASD A2 7543-M servo drive ALARM AL001 pls help repair parts name send help
Please, I am listening you
Delta ASD A2 7543-M servo drive ALARM AL001 pls help repair parts name send
Yes please
Hello! I have one ASD-A2-0721-U drive that received 400v instead of 220v. The power board is burnt. Can I replace the power board with a new one and keep the original parameters of the drive?
Hi
The answer to the second question is that there is no need to change any other parameter on the cpu board, but the power bd and the connection socket should be compatible with each other.
The igbt module and capacitors will not be suitable for 400v because only one of these elements will not work properly.
@@repairautomationproductsan3576 Hi thanks for your answer! The drive will be powered with 220v as it should be. 400v was a mistake. My question is: I bought a new drive, exactly the same model as the first one. Can I just replace the burnt power board inside it with the power board of the new one? What should I check first?
I am just trying to save the parameters of the drive because I don't have access to the parameter set from the manufacturer of the turret servo drive...
Al 031 how to find?...
İncorrect wiring of the motor cable, u,v,w gnd or the connection between both is breakdown
First the ight module should be checked, and then the photo couplers located on the trigger legs of this module should be replaced,of course,CPU bd should also be changed an tried
@@repairautomationproductsan3576 ok sir thank you
Nice music
Number of diode please for repla sed
Dzd83 my friend
Dear sir, I also use ASDA-A2 4.kW 220v too. I've faced this problem much time, Do you think what is the main problem that could cause this alarm? I've not yet solved this problem, do you any solution for me? Thanks brother.
Hello Brother. The first source of this problem is the igbt module. If it is broken, you should check the diode and resistors in the trigger legs, if there are tiny cards in the trigger legs as in the video, the transistor on them is defective. If you are sure of the integrity of the motherboard, the CPU board should be tested, you should do these tests with a solid and one-to-one motor because if the motor windings are short-circuited, you will not get the repair result correctly
Sorry for the late reply, I can't deal with the channel content nowadays
What did you replace it with
You should replace it with a 5.1 volt zener diode
good job. r you only servo drıver repaired .isn't it
güzel bie çalışma olmuş
very good job
Very helpful 👍 Thanks
Don't matter my friend
@@repairautomationproductsan3576 please send email address or contact Number i will share the problem of servo driver
Sir you have what s up number pls Share sir
Sir b2 servo drive show Al001 what part required to change
In these servos you should first suspect the photocoupler on the trigger legs and the capacitors, then it might be Igbt. If you ask me I try CPU board first
Merhaba. Al003 hata veriyor. bilgi verirmisiniz
Bu kod size ne zaman geliyorsa o yönde ilerlemek lazım, kondansatör olabilir röle olabilir softstarter olur. Modül olur tamam mı sssssss kardeş
@@repairautomationproductsan3576 tm abi teşekkur ederim
Which part removed? Diode
Dzd83 friend
Ashif bhai your problem is solved
Peki B2 servo motor Ale24 veriyor ,bu konuda Bilgi verebilir misiniz
Delta otomasyon ürünlerinin tamiri ile ilgili sorularınızı bekliyorum.I am waiting for your questions regarding the repair of Delta automation products.
Yes but
Pls Share your what's up number
You have any other massager pls Share
Merhaba güç kartının arka tarafında bulunan dd13 diyotunun karşısındaki r207 ile baslayan aşağıya doğru 3 adet olan smd dirençlerin değerleri yandığı için okunmyor yardımcı olabilirmisiniz?
Bugün yardımcı olacağım