Probir Kumar Saha
Probir Kumar Saha
  • 34
  • 300 891
Hose Test at Site for Façade or Structural Glazing
Hose Test at Site for Façade or Structural Glazing
มุมมอง: 42

วีดีโอ

Share(3)
มุมมอง 403 ปีที่แล้ว
Share(3)
#short Interior desing of Dom
มุมมอง 223 ปีที่แล้ว
Interior desing of Dom My Popular videos: th-cam.com/video/TbK8E2iI1dg/w-d-xo.html​ th-cam.com/video/2jb6jKQd3RE/w-d-xo.html​ th-cam.com/video/SlIwJ4U7WYA/w-d-xo.html​ th-cam.com/video/A2buYUje2do/w-d-xo.html​ th-cam.com/video/Fq7lbsutuxc/w-d-xo.html​ My Blogs: probireng.blogspot.com​ probireng.wordpress.com​ SUBSCRIBE ➡️th-cam.com/channels/j5s.html... (New video every Friday!) TRANSLATE THIS V...
A Sweet Home
มุมมอง 643 ปีที่แล้ว
A Sweet Home My Popular videos: th-cam.com/video/TbK8E2iI1dg/w-d-xo.html​ th-cam.com/video/2jb6jKQd3RE/w-d-xo.html​ th-cam.com/video/SlIwJ4U7WYA/w-d-xo.html​ th-cam.com/video/A2buYUje2do/w-d-xo.html​ th-cam.com/video/Fq7lbsutuxc/w-d-xo.html​ My Blogs: probireng.blogspot.com​ probireng.wordpress.com​ SUBSCRIBE ➡️th-cam.com/channels/j5s.html... (New video every Friday!) TRANSLATE THIS VIDEO! Do y...
How to Survey a Super flat slab leveling
มุมมอง 4883 ปีที่แล้ว
How to Survey a Super flat slab leveling: Computer Generated Survey Report download link: drive.google.com/file/d/1NFdsOxOVHXtAMn9p3GVobcLhEIUy0doy/view?usp=sharing Hi Viewers, Today I am going to show you how to conduct a “super flat slab” survey. Using instruments. If you find this video is useful, please subscribe to my channel. Hit the bell icon, to get notification for my next video. Click...
Presidency University Picnic 2006 Part 5
มุมมอง 953 ปีที่แล้ว
Presidency University Picnic 2006 Part 5 Parting Glass by Audionautix is licensed under a Creative Commons Attribution license (creativecommons.org/licenses/by/4.0/) Artist: audionautix.com/ The video I recommend! Presidency University Picnic 2006 Part 1 th-cam.com/video/oGC0Gcu7eUM/w-d-xo.html Presidency University Picnic 2006 Part 2 th-cam.com/video/LFNGwvpzYPg/w-d-xo.html Presidency Universi...
Presidency University Picnic 2006 Part 4
มุมมอง 763 ปีที่แล้ว
Presidency University Picnic 2006 Part 4 Parting Glass by Audionautix is licensed under a Creative Commons Attribution license (creativecommons.org/licenses/by/4.0/) Artist: audionautix.com/ The video I recommend! Presidency University Picnic 2006 Part 1 th-cam.com/video/oGC0Gcu7eUM/w-d-xo.html Presidency University Picnic 2006 Part 2 th-cam.com/video/LFNGwvpzYPg/w-d-xo.html Presidency Universi...
Presidency University Picnic 2006 Part 3
มุมมอง 733 ปีที่แล้ว
Presidency University Picnic 2006 Part 3 Parting Glass by Audionautix is licensed under a Creative Commons Attribution license (creativecommons.org/licenses/by/4.0/) Artist: audionautix.com/ The video I recommend! Presidency University Picnic 2006 Part 1 th-cam.com/video/oGC0Gcu7eUM/w-d-xo.html Presidency University Picnic 2006 Part 2 th-cam.com/video/LFNGwvpzYPg/w-d-xo.html Presidency Universi...
Presidency University Picnic 2006 Part 2
มุมมอง 733 ปีที่แล้ว
Presidency University Picnic 2006 Part 2 Parting Glass by Audionautix is licensed under a Creative Commons Attribution license (creativecommons.org/licenses/by/4.0/) Artist: audionautix.com/ The video I recommend! Presidency University Picnic 2006 Part 1 th-cam.com/video/oGC0Gcu7eUM/w-d-xo.html Presidency University Picnic 2006 Part 3 th-cam.com/video/bYcSJBso1XU/w-d-xo.html Presidency Universi...
Presidency University Picnic 2006 part 1
มุมมอง 833 ปีที่แล้ว
Presidency University Picnic 2006 part 1 Parting Glass by Audionautix is licensed under a Creative Commons Attribution license (creativecommons.org/licenses/by/4.0/) Artist: audionautix.com/ The video I recommend! Presidency University Picnic 2006 Part 2 th-cam.com/video/LFNGwvpzYPg/w-d-xo.html Presidency University Picnic 2006 Part 3 th-cam.com/video/bYcSJBso1XU/w-d-xo.html Presidency Universi...
Beautiful Atish Bazi show
มุมมอง 6923 ปีที่แล้ว
Beautiful Atish Bazi show
How to clean kitchen ventilated ceiling automatically
มุมมอง 1263 ปีที่แล้ว
How to clean kitchen ventilated ceiling automatically
Car rollover safety awareness at a construction site
มุมมอง 913 ปีที่แล้ว
Car rollover safety awareness at a construction site
Façade or Structural Glazing LaboratoryTest
มุมมอง 1973 ปีที่แล้ว
Façade or Structural Glazing LaboratoryTest
Nationwide lockdown begins in Oman
มุมมอง 5104 ปีที่แล้ว
Nationwide lockdown begins in Oman
How to add your friend s channel and video
มุมมอง 3.6K4 ปีที่แล้ว
How to add your friend s channel and video
how to upload videos to youtube 2020
มุมมอง 3344 ปีที่แล้ว
how to upload videos to youtube 2020
Plaster pull out test
มุมมอง 17K4 ปีที่แล้ว
Plaster pull out test
PREPARATION FOR FLOOR CRACK RECTIFICATION
มุมมอง 7444 ปีที่แล้ว
PREPARATION FOR FLOOR CRACK RECTIFICATION
The beauty of Omani dates
มุมมอง 7524 ปีที่แล้ว
The beauty of Omani dates
CONCRETE PILE CLEAR COVER
มุมมอง 4K4 ปีที่แล้ว
CONCRETE PILE CLEAR COVER
Footing or Pile cap concreting
มุมมอง 3.8K4 ปีที่แล้ว
Footing or Pile cap concreting
RCC Pile concreting cast in situ method
มุมมอง 31K7 ปีที่แล้ว
RCC Pile concreting cast in situ method
Wall Plastering using mortar and pump
มุมมอง 6567 ปีที่แล้ว
Wall Plastering using mortar and pump
Floor tiles epoxy grouting works
มุมมอง 31K7 ปีที่แล้ว
Floor tiles epoxy grouting works
Super Flat Slab step by step full video
มุมมอง 124K8 ปีที่แล้ว
Super Flat Slab step by step full video
Concrete Slump test
มุมมอง 1.8K8 ปีที่แล้ว
Concrete Slump test
MOR test
มุมมอง 15K8 ปีที่แล้ว
MOR test
Re-bar bend-rebend test at laboratory
มุมมอง 63K9 ปีที่แล้ว
Re-bar bend-rebend test at laboratory

ความคิดเห็น

  • @oraby2020
    @oraby2020 16 วันที่ผ่านมา

    great job. kindly, how much distance between expansion joints ? and there was a control joint by saw cut after concrete get hard ?

    • @probirkumarsaha
      @probirkumarsaha 16 วันที่ผ่านมา

      There were expansion joints around 10m distance. No control joints were there by saw cut after concrete get hard.

  • @sanju.123dance5
    @sanju.123dance5 5 หลายเดือนก่อน

    Its Really a amazing work👏🏻 i need more information about this pull off test.Sir can u please let me know??

    • @sanju.123dance5
      @sanju.123dance5 4 หลายเดือนก่อน

      Please reply backsir

  • @nicholasbrunetti2956
    @nicholasbrunetti2956 7 หลายเดือนก่อน

    12 foot wide is at the maximum for FF 100/fl65 floors......

  • @bicbouy4126
    @bicbouy4126 10 หลายเดือนก่อน

    Guy checking laser screed is set at right height at the start isn’t even holding the laser height stick plumb, he tells the operator 2 millimetres up when his height stick is out of plumb by about 2 millimeters. Guy needs a spirit level bubble on his height stick

  • @Forgotthatshit
    @Forgotthatshit 11 หลายเดือนก่อน

    Hi. What is plaster pull out equipment specification and how i can buy it?

  • @pilingdrill
    @pilingdrill ปีที่แล้ว

    Good job

  • @mythistory6019
    @mythistory6019 ปีที่แล้ว

    Any contacts of the agency to conduct this test in Bangalore ?

  • @daelster
    @daelster ปีที่แล้ว

    Good music

  • @jodelmaralvessaraiva5780
    @jodelmaralvessaraiva5780 ปีที่แล้ว

    Vou parai

  • @joshuaandrew691
    @joshuaandrew691 ปีที่แล้ว

    Dear Mr. probib kumat, good informative video. Also, Please tell what is the name of pull out test equipment, current reading and required reading with unit. Thanks.

    • @sanju.123dance5
      @sanju.123dance5 5 หลายเดือนก่อน

      Sir do u get any information about this equipment??

  • @alexandermadwrite2154
    @alexandermadwrite2154 2 ปีที่แล้ว

    But how do you do it on Mobile

  • @calebcoffman6897
    @calebcoffman6897 2 ปีที่แล้ว

    Yikes 9” slump is absolutely terrible even with fly ash and being a flowable mix with fibers, even a high range mix design typically won’t call for that high of a slump, that’s terrible. Good luck on those breaks

    • @calebcoffman6897
      @calebcoffman6897 2 ปีที่แล้ว

      Then again the testing procedure for slump was done wrong, he was tamping the first layer and hitting the bottom of the slump cone, plus he only did a maybe 3 second pull which doesn’t constitute a proper slump test, he did do the test within 2 min 30 secs, so at least he did one thing right.

  • @chautrongan6183
    @chautrongan6183 2 ปีที่แล้ว

    Thank Sir 👍😊

  • @mr.alankar3059
    @mr.alankar3059 2 ปีที่แล้ว

    half of test explained sir... how to cut plaster in circle shape, its deep how to fix dolly in that grove, which adhesive required how many times to set adhesive after that you explain next procedure

    • @probirkumarsaha
      @probirkumarsaha 2 ปีที่แล้ว

      Thanks for your comments. Plaster cut in circle shape buy pull up test. Dolly fixed by glue at least 24 hours. At this moment I have forgotten the adhesive name.

  • @constructionknowledge6012
    @constructionknowledge6012 2 ปีที่แล้ว

    Nice video

  • @kiplane5229
    @kiplane5229 2 ปีที่แล้ว

    Can I add a video I’ve posted to my friends channel which is opposite of what your doing..your taking her video to yours but I want to give my video to his softball channel

  • @robertchu1179
    @robertchu1179 2 ปีที่แล้ว

    Can someone plz tell me what does RCC means, it’s full name

    • @probirkumarsaha
      @probirkumarsaha 2 ปีที่แล้ว

      RCC means "Reinforcement Cement Concrete"

    • @robertchu1179
      @robertchu1179 2 ปีที่แล้ว

      @@probirkumarsaha thank you so much

  • @kenbrown9228
    @kenbrown9228 2 ปีที่แล้ว

    X

  • @tusharshinde2121
    @tusharshinde2121 2 ปีที่แล้ว

    How much minimum values required for pullout test withunit of measurements

    • @naveedjan8715
      @naveedjan8715 2 ปีที่แล้ว

      if it is pre-mixed plaster, refer to manufacturer material data sheet. it varies but average 0.3 MPa minimum. For in situ plaster refer to British Standards.

  • @hitendrarayamajhi7262
    @hitendrarayamajhi7262 2 ปีที่แล้ว

    If in case joints needed to be placed due to break in concreting works, What should be its position? What should be needed to be done in such case?

    • @probirkumarsaha
      @probirkumarsaha 2 ปีที่แล้ว

      Thank you for your comment. Could you please elaborate your question for my better understanding?

    • @hitendrarayamajhi7262
      @hitendrarayamajhi7262 2 ปีที่แล้ว

      @@probirkumarsaha Sir. I mean to say that if in any case when we cant do the whole quantity of concrete continuously which is required for the pile cap and if we are under the circumstances where we have to beak the concreting work and introduce a joint in any way, then in such case what should be the position of the joint and what type of joint (vertical or horizontal) is needed to be introduced in the pile cap ?

    • @probirkumarsaha
      @probirkumarsaha 2 ปีที่แล้ว

      @@hitendrarayamajhi7262 Thank you. The joint is called Construction joint. Before the 2nd pour concreting some bonding agent can used before pouring. The joint could be made rough by chipping before the the 2nd pour.

  • @govigobi
    @govigobi 2 ปีที่แล้ว

    Where it's mentioned for vertical distance mention in IS2911

  • @rakeshmondal7990
    @rakeshmondal7990 3 ปีที่แล้ว

    Spacing this cover block as per is per meter

  • @Lisa-yy4or
    @Lisa-yy4or 3 ปีที่แล้ว

    I don't have any friends in youtube this helping to me

  • @ashishchaudhari7048
    @ashishchaudhari7048 3 ปีที่แล้ว

    Sir, if you explain about readings and reference range of pull out test is much appreciated.

  • @dabrosfloorsurveysltduk1789
    @dabrosfloorsurveysltduk1789 3 ปีที่แล้ว

    This procedure shown at 17:00 can lead to delamination issues.

  • @Prashant-sr6fj
    @Prashant-sr6fj 3 ปีที่แล้ว

    Hi i am PhD research scholar at IIT Bombay. can you please send me the equipment specification, I want purchase this. @probir saha

    • @probirkumarsaha
      @probirkumarsaha 3 ปีที่แล้ว

      Hi, Extremely sorry. At present I am not in position to help you. Anyway I will try to help you.

    • @Prashant-sr6fj
      @Prashant-sr6fj 3 ปีที่แล้ว

      @@probirkumarsaha thanks for your reply. i am waiing for the machine specification. or please give me the suppliers information.

  • @joylincy6580
    @joylincy6580 3 ปีที่แล้ว

    Thanks for the video.

  • @SATISHYADAV-tx8ho
    @SATISHYADAV-tx8ho 3 ปีที่แล้ว

    Re bend ka kaha per hai

    • @SATISHYADAV-tx8ho
      @SATISHYADAV-tx8ho 3 ปีที่แล้ว

      Re- Bend IS 1786-2008 ME JO DIYA HAI WAHI WALA ULTA KARKE PRESS NAHI KARNA HAI MAIDRIL SE HI 157.5 ME LANA HAI.SIR KAISE HOGA

  • @kevin_prathi
    @kevin_prathi 3 ปีที่แล้ว

    Is there any test to check the plastering work in wall (inner wall plastering and outer wall plastering)

    • @probirkumarsaha
      @probirkumarsaha 3 ปีที่แล้ว

      Yea, the same test for inner and outer wall

    • @kevin_prathi
      @kevin_prathi 3 ปีที่แล้ว

      @@probirkumarsaha thank you

  • @moathunter5504
    @moathunter5504 3 ปีที่แล้ว

    Why is he using a Helmet for this work ?

    • @probirkumarsaha
      @probirkumarsaha 3 ปีที่แล้ว

      Hi, It was a Project's HSE requirement.

  • @nkg00007
    @nkg00007 3 ปีที่แล้ว

    Clicking on cuztomize channel will take me to youtube studio...Please update this video

  • @Oaik_knowledge
    @Oaik_knowledge 3 ปีที่แล้ว

    Hi bhya kaise ho. Can I talk to u Plz come on my WhatsApp 9759746678

  • @raffiehydermirza1803
    @raffiehydermirza1803 3 ปีที่แล้ว

    Equipment name and how many samples to be taken and is it also same for gypsum?

  • @rkbisheswar2024
    @rkbisheswar2024 3 ปีที่แล้ว

    Kindly let me know the your testing strength

  • @qillaainur2877
    @qillaainur2877 3 ปีที่แล้ว

    flat floor good ....

  • @gladiator2017
    @gladiator2017 3 ปีที่แล้ว

    @probir Saha - do you know any govt authorized quality testing firm which conducts this in kerala ? I am facing some plastering issue in my apartment and builder is saying plastering is fine. I want to understand how to verify that. Also is there any govt lab in kerala which takes plastering sample and do some testing to measure the cement/sand ratio.

    • @probirkumarsaha
      @probirkumarsaha 3 ปีที่แล้ว

      Hi, Sorry I don't know.... Thanks for your question.

    • @gladiator2017
      @gladiator2017 3 ปีที่แล้ว

      @@probirkumarsaha do you know the standard value for the pressure required in India for apartments when the plastering test succeeds ?

    • @probirkumarsaha
      @probirkumarsaha 3 ปีที่แล้ว

      Hi, I think this docs may help you. www.mpwrd.gov.in/documents/18/b6596087-233a-49ad-9c2e-b4fb39237994

    • @probirkumarsaha
      @probirkumarsaha 3 ปีที่แล้ว

      mddaonline.in/downloads/MDDALINKS/pdf/nbc.pdf

  • @janbellopez164
    @janbellopez164 3 ปีที่แล้ว

    Good work,i am concrete riding trowel from phillipines super flat crew

  • @nabeenkumardora1959
    @nabeenkumardora1959 3 ปีที่แล้ว

    What is the spacing of cover blocks vertically?

    • @probirkumarsaha
      @probirkumarsaha 3 ปีที่แล้ว

      Please have a look this video, 5min 29 sec, vertical spacing 1m we have considered. th-cam.com/video/2jb6jKQd3RE/w-d-xo.html

  • @vivekgupta7104
    @vivekgupta7104 3 ปีที่แล้ว

    What is the is code can any one recommend

  • @AHoney-xl9ux
    @AHoney-xl9ux 3 ปีที่แล้ว

    How much plaster strength required in N/mm2 ? What is acceptance criteria?

    • @probirkumarsaha
      @probirkumarsaha 3 ปีที่แล้ว

      The test will work reliably over an adhesion strength range between 0.2 and 50 N/mm2.

  • @habibkhan8410
    @habibkhan8410 3 ปีที่แล้ว

    Dear Sir can you provide the Contact details of testing agency in DEHLI NCR india.

    • @probirkumarsaha
      @probirkumarsaha 3 ปีที่แล้ว

      Testing agency I know in Oman only.

  • @To8Noob
    @To8Noob 3 ปีที่แล้ว

    me like and sub ignore the hater from dislike :D

  • @lethukuthuladerrick5522
    @lethukuthuladerrick5522 3 ปีที่แล้ว

    Perfect teaching. I now understand keep it up thank you

  • @akhtarali-qv3en
    @akhtarali-qv3en 3 ปีที่แล้ว

    Thanks for latest update

  • @drogogaming8302
    @drogogaming8302 4 ปีที่แล้ว

    why shear links are not provided in pile cap

  • @TonzandPinkz
    @TonzandPinkz 4 ปีที่แล้ว

    This is RAK Ceramics and the one who tested the tiles is my friend😁😁😁

    • @m-2728
      @m-2728 2 ปีที่แล้ว

      Rak ceramics this is best company in the UAE

  • @arjunapoxegroutwork8877
    @arjunapoxegroutwork8877 4 ปีที่แล้ว

    Apoxe & Grouting work 9601191392

  • @dancristurean3680
    @dancristurean3680 4 ปีที่แล้ว

    Hello, Good work! I also want to buy a device for measuring flatness, the one that appears at minute 16; 28 and 34. Can you tell me his name or the name of the company where I can buy it from? If you can also for curing equipment? thank you , Dan

  • @emmalee2520
    @emmalee2520 4 ปีที่แล้ว

    we supply various compression testing mahcine and universal test machine. Whatsapp 0086 13363667903

  • @jaidulsekh3883
    @jaidulsekh3883 4 ปีที่แล้ว

    Agar pile kajer khobor nai dada