Aircon tutorial channel
เข้าร่วมเมื่อ 10 ก.พ. 2020
Paano kung walang adaptor na pang r410 or r32 refrigerant, may paraan ba?
Paano kung walang adaptor na pang r410 or r32 refrigerant, may paraan ba?
มุมมอง: 1 988
วีดีโอ
How to remove the corrosion in connector?
มุมมอง 2093 ปีที่แล้ว
How to remove the corrosion in connector?
R22 use for flushing and leak test in refrigerator repair.
มุมมอง 4.5K3 ปีที่แล้ว
R22 use for flushing and leak test in refrigerator repair.
Two copper pipes together in one rubber insulation is Correct?
มุมมอง 6K3 ปีที่แล้ว
Two copper pipes together in one rubber insulation is Correct?
How to repair refrigerant leak in Aircon?
มุมมอง 3223 ปีที่แล้ว
How to repair refrigerant leak in Aircon?
Refrigerant leak seen in service valve, what can I do?
มุมมอง 1.3K3 ปีที่แล้ว
Refrigerant leak seen in service valve, what can I do?
Corrosion and Oxidation of A/C Condenser made in Aluminum
มุมมอง 8413 ปีที่แล้ว
more info about metal you use
Bad results by using flexible hose as a drain line of Aircon.
มุมมอง 1.7K3 ปีที่แล้ว
Bad results by using flexible hose as a drain line of Aircon.
How to check the drain pump if it is working or not.
มุมมอง 15K3 ปีที่แล้ว
How to check the drain pump if it is working or not.
Right design of drain pipe for ceiling cassette type.
มุมมอง 2.2K3 ปีที่แล้ว
Right design of drain pipe for ceiling cassette type.
Air Bender for outdoor unit with small space
มุมมอง 2813 ปีที่แล้ว
Air Bender for outdoor unit with small space
How to clean Wall Mounted AC step by step?
มุมมอง 2793 ปีที่แล้ว
How to clean Wall Mounted AC step by step?
Lye or potassium hydroxide, used for cleansing.
มุมมอง 12K3 ปีที่แล้ว
Lye or potassium hydroxide, used for cleansing.
Low speed of fan motor caused the unsufficient cool of AC.
มุมมอง 9K3 ปีที่แล้ว
Low speed of fan motor caused the unsufficient cool of AC.
Dapat ganyan ang install ng piping hindi sya shout circle ok yan master tama yan ginawa mo
yung samin .5hp hanabishi eco frost series wala din drinage. nagwoworry ako kasi naririnig ko ung tubig sa loob baka kako masira yung aircon namin kaya pina drain ko sa asawa ko.
hindi rin siya natulo. tas nung nakaraan tumulo yung tubig sa likod tas kapag pinapatay yung aircon naririnig ko yung tubig sa loob. kaya nung binalik ng asawa ko yung ac pina- tilt ko ng kaunti
Gaano lang kahaba nang pipe ang pwede sa 1.5 hp .. yung maximum na haba po
Ok yan pro mas maigi may air vent sa unahan ng elbow just incase sa maintenance madali iflushing
SsD
MAster hm po pagpaayus ng ganyan trouble
boss Yung nabili ko na union .06hp window type Wala din butas ok lang ba yun salamat
Salamat po
Mgkno po mgpagawa ng capacitor?
kuya, hindi rin po maganda na gamitin ang flexible both sa drain and sa wire po kasi po ang flexible hose po madali po sha masira due to hindi talaga sha matibay at hindi sha pang outdoor. agree po ba kayo?
Dol Hindi ba masirap yong motor fan
Paanu nmn po yung tumuigas na vulcaseal pwd pb magamit ulit
Pipe sensor Po Walang kahitan sa board
Mas matibay ang aluminum welding.. Use flux core alurod then use aluminium flux
gud day sir,ask ko lang po ganito problema ng ac ko,mahina po ang buga ng fan sa labas,pag naka set naman ng 18 to 20 malamig sia pero pag naka set ng 23 to 26 mahina napo ang lamig nia tsaka ung fan sa labas mahina ang buga nia,anu po kaya ang problema sir,dpo sapat ung lamig ng 23 to 26 bagong linis narin ang ac,dati po kc pag nakaset ng 26 malamig na at malakas ang buga ng fan sa outdoor,ngaun humina na po ang buga
Hm po pg ganyan
Magkano po pagawa?
Salamat po, very informative❤️❤️new subscriber here.
Ok master more vedio pa ang galing mastet
Bro ano po size ng breaker at wire na gagamitin po pag 1.5 hp window type air con. thanks po
sa discharge po o sa suction ikakabit hose
Paanu pu pg ngkaron ng crack sa may gilid n mahaba samsung inverter pu ung ref ok lng b un?bkit pu kya bgla nlng ngkaron ng crack d nman pu nmin ntatamaan un salamat sa pg pansin
Kung nka-klebe nmn ang tubo malayo nmn bumalik ang tubig kahit na nka straight line lang sya
Salamat idol sa pgshare ng kaalaman
Hello Idol good afternoon, watching here Idol stay connected, ingat kayo palagi dyn GOD BLESS US ALL ✅👍❤
Pwede po ba kapag umuulan to
Pwede po ba panglinis ang degreaser sir
Muntik ko ng butasan aircon ko. Buti na lang napanood ko ito
❤❤❤ i love Technician. Doing like this the true legendary technician . Salute sayo sir..
Salamat po sa Dios ❤
Idol bakit po ganun same scenario naman saken pero Pag dumami na Ung tubig. Namamatay ung compressor tapos dina Bubukas ulet ung compressor sana masagot
Bro dapat po ba kaltasan kahit konti yun side ng angle bar .para po nakayuko say konti para WAG tumulo tubig sa loob.thanks po
number new sor
Parang kulang ung copper tubing standard kase 10' pero ok ung pag ka install nice.
dapat tlga d butasan pra. ung bakal s gilid ng radiator mbulok.. tas ska n ppasok ang ac technician..
ty idol
Parang di applicable sa LG kasi madami talaga tumutulo kaya sinasahod ko din tubig.
salamat po sa tutorial. hindi ko na bubutasan ang AC ko na .5 Carrier.
Sir anu maganda ipantakip sa butas na nabutasan anu pwede ilagay salamat po
saan ho kayo nag cleacleaning service ng aircon?
Dapat sa baba ang aircon, 3 - 5 ft. from the flooring lng
idol pa turo naman po ganyan din yong ng yari saakin mahina din ang buga ng out door fan same unit din po
Pwede ba Yan sa Inverter split type Aircon ? Kapag nasira na ang mother board ( PCB ).
pwede namang butasan yan boss pero di totally sa pinaka floor ng A/C may portion jan medyu mataas don ka magbutas alam ko me butas nayan kaso masyadong mataas nagtatalsikan sa loob mappasukan ng tubig yung fan motor kawawa bearing mojan pag nkapantay payung A/C mo sa harap sa totulo malas mo pag naabot yung mga wire ng may switch .
Pano po pag may tumatalsik ng konti sa harap
Taga saan po kayo
Kaya pala mahina ang lamig ng ac ko binutasan ko kasi... Pero pag walang butas may may konting ingay ako naririnig normal lang po ba yon... Salamat sa info.
the mindset of "pwede na yan"
sir sana masagot, ang epekto po ba niya ay mamatay ang fan pati yong indoor?
Good idea