- 72
- 28 531
Ferrarini Benelli
เข้าร่วมเมื่อ 22 เม.ย. 2012
Ferrarini & Benelli design and manufacture stations for Corona Surface treatment and Plasma treatment. The company's HQ is in Romanengo in the Italian province of Cremona.
Ferrarini & Benelli - DRUPA 2024
Want to know more about the Ferrarini & Benelli's experience at Drupa 2024?
After 8 years since the last edition took place, our team was ready for Drupa, one of the top events in the sectors of printing and converting worldwide!
We met new visitors and spoke to old friends, shared ideas and knowledge, spoke about the latest technical innovation and presented a brand new product, our sheetfed corona treatment system, Format!
After so much time has passed since the last Drupa edition, we finally had the chance to experience this incredible event again.
Enjoy the video and make sure to visit our booth at the next exhibition!
After 8 years since the last edition took place, our team was ready for Drupa, one of the top events in the sectors of printing and converting worldwide!
We met new visitors and spoke to old friends, shared ideas and knowledge, spoke about the latest technical innovation and presented a brand new product, our sheetfed corona treatment system, Format!
After so much time has passed since the last Drupa edition, we finally had the chance to experience this incredible event again.
Enjoy the video and make sure to visit our booth at the next exhibition!
มุมมอง: 36
วีดีโอ
Ferrarini & Benelli - Measuring a substrate's surface tension
มุมมอง 2217 หลายเดือนก่อน
Have you ever wondered how you can effectively check if the surface tension of a substrate has improved after treatment? You can check the surface tension before and after treatment and make sure that treatment has been effective. Here you can see our General Manager, Claudia Benelli, showing how the process of measuring the surface tension works, using our Dyne Test Pen, the non-toxic quick te...
Ferrarini & Benelli - Format treatment system at Drupa 2024
มุมมอง 687 หลายเดือนก่อน
At Drupa 2024 Ferrarini & Benelli presents the new Format treatment system to treat individual sheets of different sizes, format and thicknesses. During the exhibition samples of sheets were live tested and the effect of corona treatment was measured with the Dyne testing kit. Enjoy the video!
CORONA TREATMENT FOR EXTRUSION
มุมมอง 1089 หลายเดือนก่อน
Bikappa Rotary is the corona treatment system suitable for mounting on high-performance blown film extruders or flexo presses in line with extruders. Here is a Bikappa Rotary installed on an extrusion line.
EL TRATAMIENTO PLASMA DE FERRARINI & BENELLI
มุมมอง 133ปีที่แล้ว
El tratamiento plasma de Ferrarini & Benelli activa las superficies plásticas y las hace más receptivas a las tintas de impresión, barnices, colas y revestimientos (tanto de base disolvente como no disolvente) para garantizar una adhesión óptima durante el encolado, la impresión, el sellado y la codificación/marcado. El tratamiento plasma está diseñado para integrarse fácilmente en la línea de ...
PLASMA TREATMENT BY FERRARINI & BENELLI
มุมมอง 104ปีที่แล้ว
Plasma treatment by Ferrarini & Benelli activates plastic surfaces and makes them more receptive to printing inks, varnish, glues and coatings (both solvent and non-solvent based) to ensure optimal adhesion during bonding, printing, sealing and coding/marking. Plasma treatment is designed to integrate easily into the customer's production line, requires no special maintenance and is a sustainab...
IL TRATTAMENTO PLASMA DI FERRARINI & BENELLI
มุมมอง 85ปีที่แล้ว
Il trattamento plasma di Ferrarini & Benelli attiva le superfici plastiche e le rende più ricettive a inchiostri di stampa, vernici, colle e coating (a base solvente e non) per garantire un'adesione ottimale nelle fasi di incollaggio, stampa, verniciatura, sigillatura e codifica/marcatura. Il trattamento plasma è studiato per integrarsi facilmente sulla linea di produzione del cliente, non rich...
SISTEMA DE TRATAMIENTO CORONA MINI BIKAPPA
มุมมอง 31ปีที่แล้ว
Mini Bikappa es un pequeño tratador corona bilateral, adecuado para su montaje en extrusoras de burbuja de laboratorio. Es un sistema que se instala fácilmente en líneas de extrusión de burbuja de laboratorio o líneas piloto, que las empresas utilizan para: - probar masterbatches, aditivos, mezclas y polímeros reciclados - comprobar la calidad de la película producida - desarrollar películas mu...
MINI BIKAPPA CORONA TREATMENT SYSTEM
มุมมอง 26ปีที่แล้ว
Mini Bikappa is a small double-sided corona treatment system, suitable for installation on laboratory blown film extruders. This is system can be installed easily on blown film extruders or pilot extrusion lines, which are used by companies to: - test masterbatches, additives, blend and recycled polymers - check the quality of the film manufactured - develop high-performance multi-layer films -...
SISTEMA DI TRATTAMENTO CORONA MINI BIKAPPA
มุมมอง 16ปีที่แล้ว
Mini Bikappa è una stazione di trattamento corona bilaterale di piccole dimensioni, adatta ad essere montata su estrusori in bolla da laboratorio. Si tratta di un sistema facilmente installabile su linee di estrusione in bolla da laboratorio o linee pilota, che vengono utilizzate dalle aziende per: - testare masterbatches, additivi, miscele e polimeri riciclati - controllare la qualità del film...
GENERADOR DIGITAL EVO SMART - TRATAMIENTO CORONA
มุมมอง 136ปีที่แล้ว
El generador digital Evo Smart diseñado y fabricado por Ferrarini & Benelli es un generador trifásico con una innovación tecnológica sin precedentes. Evo Smart alcanza la potencia necesaria para tratar cualquier sustrato plástico a las más altas velocidades de línea dentro de las numerosas aplicaciones del tratamiento corona: extrusión, recubrimiento por extrusión, laminación, revestimiento e i...
Ferrarini & Benelli - Nuestra misión
มุมมอง 15ปีที่แล้ว
Nuestra misión es ofrecer soluciones innovadoras en tratamientos superficiales, para cada material, en cada aplicación y ayudar a los clientes a elegir el mejor modelo para cada necesidad, apoyándoles desde la fase de diseño de la máquina hasta la asistencia técnica. Nuestras soluciones: tratamiento corona, que aumenta la tensión superficial para mejorar la adhesión de tintas, colas y revestimi...
EL TRATAMIENTO CORONA DE FERRARINI & BENELLI
มุมมอง 923ปีที่แล้ว
EL TRATAMIENTO CORONA DE FERRARINI & BENELLI
IL TRATTAMENTO CORONA DI FERRARINI & BENELLI
มุมมอง 113ปีที่แล้ว
IL TRATTAMENTO CORONA DI FERRARINI & BENELLI
TINTAS DE PRUEBA, ROTULADORES Y MARCADORES CORONA: KIT PARA MEDIR LA HUMECTABILIDAD DE UN SUSTRATO
มุมมอง 532ปีที่แล้ว
TINTAS DE PRUEBA, ROTULADORES Y MARCADORES CORONA: KIT PARA MEDIR LA HUMECTABILIDAD DE UN SUSTRATO
Veuillez découvrir les nouveautés du traitement Corona présenté au salon K 2022
มุมมอง 552 ปีที่แล้ว
Veuillez découvrir les nouveautés du traitement Corona présenté au salon K 2022
Ferrarini & Benelli en la feria K 2022: entrevista a nuestros agentes de Comercial Andexport
มุมมอง 1622 ปีที่แล้ว
Ferrarini & Benelli en la feria K 2022: entrevista a nuestros agentes de Comercial Andexport
Ferrarini & Benelli al K 2022: trattamento Plasma
มุมมอง 892 ปีที่แล้ว
Ferrarini & Benelli al K 2022: trattamento Plasma
Ferrarini & Benelli al K 2022: Generatore Digitale Evo Smart
มุมมอง 312 ปีที่แล้ว
Ferrarini & Benelli al K 2022: Generatore Digitale Evo Smart
Ferrarini & Benelli at the K 2022 show: Plasma treatment
มุมมอง 652 ปีที่แล้ว
Ferrarini & Benelli at the K 2022 show: Plasma treatment
can you guid me how to make dyne level chking ink.... for marker.
we can supply dyne level markers, if you’re interested you can contact our sales dept sales@ferben.com
What a strange creature.
Isn't there a mistake in the video? It says that (especially 2:06) that "surface tension is at least 38 dyne/cm" which next changes into wetting. As far as I know, the less surface tension we have, the more surface energy we have, where energy surface equals to the wetting. Please, correct me if I am wrong :)
can you help me, that how to make ink for dyne marker
we can supply dyne marker, if you need you can contact our sales dept sales@ferben.com
what you’re saying is not correct. The higher is the surface energy of a material, the higher is the west ability. Then you have to consider that the surface energy of a material is different from the surface tension of a liquid. The surface energy of the surface must be higher than the surface tension of a liquid in of at least 10 points if you want the liquid to wet the material’s surface.
@@ferrarinibenellithis is exactly what I meant - in order to achieve proper adhesion, the surfaces energy has to be higher than surface tension of the liquid. Nevertheless on the video you have mixed the tension with wetting I think.
@@ReavenLaux I understand what you mean. Actually the words ‘surface tension’ and ‘surface energy’ have the same meaning if referred to a substrate (always measured in dyne/cm). Thank you for your accurate comment.
promosm 😳
Hola, envía un correo electrónico a tech@ferben.com nuestros técnicos te enviarán las instrucciones. Gracias
Saludos!
Saludos amigos, trabajo con una laminadora nordmeccanica y usamos el tratamiento corona F&B, quisiers saber como se hace la limpieza de la retratadora, rodillo de cerámica, electrodos, erc. Muchas gracias!
Saludos desde Perú!!!
Muy buenas máquinas, saludos!
Gracias, saludos!
I need electrical drawing
Tecnología de punta.