basement bathroom roughin drain and venting2
Basement bathroom layout with rough-in drain and vent. A virtual tour.
มุมมอง: 370 113

วีดีโอ

basement bathroom roughin drain and venting 1
มุมมอง 22K6 ปีที่แล้ว
Basement bathroom rough-in plumbing, drain and vent layout - virtual. Also some basic plumbing rules.

ความคิดเห็น

  • @roohdeepsidhu1073
    @roohdeepsidhu1073 6 ชั่วโมงที่ผ่านมา

    The T which used for shower drain’s vent is not correct

  • @jadenandraos-fazari3930
    @jadenandraos-fazari3930 หลายเดือนก่อน

    Vent tees backwards, and the shower back vent tee is backward, also the vent leaving the roof has to be 3" not 2. Don't rough in like this plz 🙏

  • @eng-vf2gh
    @eng-vf2gh 6 หลายเดือนก่อน

    name of this animation program can you give us the name sir

  • @sulmyguzman3280
    @sulmyguzman3280 7 หลายเดือนก่อน

    what program's is this?

  • @omegaplumbing
    @omegaplumbing 7 หลายเดือนก่อน

    The mistakes are numerous. 1) toilet should wet vent shower and lavatory. (this would correct the other mistakes) 2) shower t-wye incorrect direction and a t-wye or santee is not a drainage fitting should be a wye. 3) toilet incorrect it 180 back on itself. 4) 1/4 bends on turns incorrect 5) 3x2 tee wye on its back incorrect for toilet 6) no cleanouts on 2 inch coming out ground 7) bushings should not be used but coupling reducers for servicing. 8) vent tees wrong direction 9) Washer box p trap too high off ground should be bewteen 6-12" inches 10) P trap too close to santee creates s trap. Should be twice the distance of the pipe being used 2" would be at least 4" pipe not hub to hub. 11) Washer box drain dumping on top of laundry tube drain not good practice for suds relief. 12) You cant wet vent these fixtures unless the drain pipe is 2 pipe sizes larger. The drain should be 3 inch then a 3x2 wye for the washer box, then a 2 inch santee on top of that serving laundry sink. 13) backwater valve should be on the main preferably outside and the access brought to grade.

  • @Macksbet
    @Macksbet ปีที่แล้ว

    i see two missing cleanouts and a very important missing vent, props to anyone who knows what im talking about. oh yeah and all those illegal fittings. edit: and on my way out i wondered if this room requires a floor drain, lolllllllllllll

  • @VamooseRooter
    @VamooseRooter ปีที่แล้ว

    This plumber needs help. Not me, the guy who drew this. Read the codebook

  • @IdahoSnake-A-Drain
    @IdahoSnake-A-Drain ปีที่แล้ว

    Trap Arm on Laundry trap to short, its an "S" trap basically.

  • @dannybaldivia2731
    @dannybaldivia2731 ปีที่แล้ว

    Lol wow I guess 🤦🏼😂🤣

  • @upstateplumbing9995
    @upstateplumbing9995 ปีที่แล้ว

    What a stupid way to run a toilet line

  • @cowboyatthesea
    @cowboyatthesea 2 ปีที่แล้ว

    loos looks shitty

  • @borispeck6879
    @borispeck6879 2 ปีที่แล้ว

    Sorry check your horizontal venting fittings ????

  • @DailyMotivationUniversity
    @DailyMotivationUniversity 2 ปีที่แล้ว

    Also short turn 90s on side is a no no ... who taught you should be slapped

  • @DailyMotivationUniversity
    @DailyMotivationUniversity 2 ปีที่แล้ว

    You got san tees on back and san tee on vent for shower on back and backwards do us a favor and dont fucking plumb

  • @marka.2715
    @marka.2715 2 ปีที่แล้ว

    I though the toilet couldn't flush past other fixtures?

  • @karlhalvorson
    @karlhalvorson 2 ปีที่แล้ว

    If that's a SketchUp model, I'd love a copy of it. How can i get one?

  • @karlhalvorson
    @karlhalvorson 2 ปีที่แล้ว

    Is that a sketchUp model? Can I get a copy?

  • @brandonisrael5935
    @brandonisrael5935 2 ปีที่แล้ว

    The sanitary tee coming off the shower, for the vent, should be flipped around. You should always flow down hill.

    • @kona6451
      @kona6451 ปีที่แล้ว

      yep and a few of the upper ones were backwards as well.

  • @TheSpatulaCity
    @TheSpatulaCity 2 ปีที่แล้ว

    1:29 Not enough horizontal pipe after P trap? I'm not a plumber but I've learned that there needs to be at least a length of pipe equivalent to double the pipe diameter after a P trap. Otherwise it can act like an S trap and siphon the water out of the trap and leave sewer gases inside.

    • @Macksbet
      @Macksbet ปีที่แล้ว

      this whole diagram violates several plumbing codes from both books. it should be deleted from youtube so noone gets taught the wrong way to do plumbing

  • @thomasclint007
    @thomasclint007 2 ปีที่แล้ว

    Lots of mistakes Don't learn from this design.

  • @evaldopires3630
    @evaldopires3630 2 ปีที่แล้ว

    This video is more like find the mistakes. Do we get some gift for it? I've found 8 mistakes

  • @Kenisproactivehere
    @Kenisproactivehere 2 ปีที่แล้ว

    Almost a great video BUT...it moves too fast to read clearly. Thanx

  • @joshuamoore24_7
    @joshuamoore24_7 3 ปีที่แล้ว

    The santees are not are supposed to be there, you need combos with a long turn and the flow pointing to the direction of the grade downward flow of the main. Plus the toilets supposed to have a three inch vent stack and a clean out, then if the dfu's(drainage fixture units) allow reduce it to two inch above the clean out. The Santee's in the on the vent piping are pointing the wrong direction also. The flow of the sewer gas is supposed to point to the vent pipe end above the roof. This must be a point out what's wrong with this plumbing diagram video.

  • @tapswitchmanager7359
    @tapswitchmanager7359 3 ปีที่แล้ว

    Summary of rules in video: 1. Max distance from trap to vent: 2x pipe diameter in feet. 2. One horizontal drain 90 allowed before the trap. 3. Horizontal to vertical drop: Use a tee footing. 4. Horizontal to horizontal: Use a Y footing. 5. Vertical to horizontal drain: Use a Y footing, or a long turn 90, or a combo tee fitting. 6. ½ Inch water lines can supply three fixtures (e.g. single faucet vanity + water close + single valve tub) 7. ½ inch water lines tap off of ¾ or 1-inch lines with ½ inch pipe, to fixtures. 8. IF more than three fixtures, tap ¾ or 1-inch lines with ¾ inch. Then tap off ¾ to ½ to fixtures. 9. Full body showers require ¾ in supply to valves. 10. 3 or more toilets require a 4-inch drain pipe from the lowest toilet. 11. Shower drains can use 1 ½ drains pipes (convenient for tub to shower conversions). 12. Horizontal drains: Never go larger to smaller in downstream direction. 13. Never install drain or supply lines where they can free. 14. Sharkbite fittings will require planned access 15. Any trap that doesn’t have easy access needs to be a glue trap. 15.1. I think a glue trap is the one-piece PVC type trap (typically under floors and other inaccessible places) , as opposed to “union traps” (typically accessible under sinks).

  • @jasveerbrarganga914
    @jasveerbrarganga914 3 ปีที่แล้ว

    All vent are wrong

  • @turtleturtle4909
    @turtleturtle4909 3 ปีที่แล้ว

    Can you share this file? This is sketch Up, yes?

  • @Magnum-vr5yl
    @Magnum-vr5yl 3 ปีที่แล้ว

    Vent tee’s are backwards

  • @brucedeleskey8540
    @brucedeleskey8540 3 ปีที่แล้ว

    This is the way it should be shown 1 2 3. If you don't understand this. Don't try this because you're a dangerous

  • @josephshuler1874
    @josephshuler1874 3 ปีที่แล้ว

    San tee is backwards

  • @jcoby555
    @jcoby555 3 ปีที่แล้ว

    Bán kênh không bạn

  • @hyster2568
    @hyster2568 3 ปีที่แล้ว

    Wet venting, tees are backwards. Another thing, you can’t use a santee on its back. You’re suppose to use a combo

  • @vincentchato519
    @vincentchato519 3 ปีที่แล้ว

    All the venting is wrong just saying

    • @jwil4905
      @jwil4905 2 ปีที่แล้ว

      The venting is fine. Some of the fittings are wrong.

  • @LubaLuba1
    @LubaLuba1 3 ปีที่แล้ว

    But how can add a new shower drain to existing toilet drain on concrete slab ?? The cast iron pipe for the toilet come up from below so I need to cut before toilet flange but do I need to make a large hole / diameter??Thank you!

    • @Pipeleier
      @Pipeleier 3 ปีที่แล้ว

      You need a jackhammer and a plumbing contractor

  • @kylepace4302
    @kylepace4302 3 ปีที่แล้ว

    Why is the vent tee backwards?

  • @jwblount7802
    @jwblount7802 3 ปีที่แล้ว

    So the only T you people noticed that was backwards was on the drain system at the shower and not notice that all of the T's in the vent system is facing the wrong way of air flow!

  • @besearchingforwisdom6267
    @besearchingforwisdom6267 3 ปีที่แล้ว

    Really? Why the stupid music?

  • @MicoAlilaya
    @MicoAlilaya 3 ปีที่แล้ว

    Done subscribe - sir/maam plz subscribe and support my channel - AutoCAD contents th-cam.com/channels/RgdELUzvBQmFfmF0djLufA.html

  • @danlovins3155
    @danlovins3155 3 ปีที่แล้ว

    Please don’t use this drawing!!!There are some major mistakes on it. Sanitary tees backwards, wet venting, sizing of pipe.

    • @azycray4801
      @azycray4801 3 ปีที่แล้ว

      Agreed, this looks like a homeowner did it. Also the short turn elbows on the w/c horizontal.

    • @alang8243
      @alang8243 3 ปีที่แล้ว

      @@azycray4801 Would the toilet horizontal drain layout be OK if the short turn 90's were long sweep 90's?

    • @azycray4801
      @azycray4801 3 ปีที่แล้ว

      @@alang8243 Yes, however I would always try and minimize changes in direction. So those 2 elbows equal 180 degrees of turn before joining the shower drain. Depending on where the walls were gong to go this may have been the best they could do but normally a little thought can limit the change in direction to less than 180. If a main sewer snake ever has to be run from this W/C location, it will make the job much easier, especially if it has to be run a long distance or cutting roots out front. Of course a clean out installation is always preferable but not always available.

    • @alang8243
      @alang8243 3 ปีที่แล้ว

      @@azycray4801 Hey thanks for the info. I'm laying my drain lines out right now for a basement bathroom, and I have a similar pattern in order to get the vent under the wall. It flows to a BWV that connects to my main 4". That 4" line has a cleanout in a good location for "roto-rooting" in the future.

    • @8thyearApprentice
      @8thyearApprentice 2 ปีที่แล้ว

      I was looking at the directions of those vent tee's.....and the laundry line needs to be below the utility sink drain on top of the shitz you said .. nice catch plummma

  • @MrDarren5012
    @MrDarren5012 3 ปีที่แล้ว

    Why would you run the toilet with two 90s? Why not just a 45 strait to main drain? Same with shower

  • @alanm2842
    @alanm2842 3 ปีที่แล้ว

    the laundry sink and washing machine need to go through the back water valve

  • @fredpastuh7518
    @fredpastuh7518 3 ปีที่แล้ว

    Mistake in shower vent T?Or no?

  • @skycladraven1248
    @skycladraven1248 4 ปีที่แล้ว

    What software did you use to create this video?

    • @jinliangchen2757
      @jinliangchen2757 ปีที่แล้ว

      It might be a sketchup built in feature

  • @russron1
    @russron1 4 ปีที่แล้ว

    The san tee for vent needs to slope towards the waste line not the p trap

  • @jesusortiz6842
    @jesusortiz6842 4 ปีที่แล้ว

    Thanks for sharing with us. Could I install 2vent lines o 1 is enough. O is not allowed to add 1 extra in 1 circuit?

    • @Pipeleier
      @Pipeleier 3 ปีที่แล้ว

      With a little thought I'm sure there is a way to horizontally wet vent this bathroom using the toilet vent for the shower vent and the lavatory drain

  • @jongaston1254
    @jongaston1254 4 ปีที่แล้ว

    Love the example. Nice job. Hate the music.

  • @jaredfink725
    @jaredfink725 4 ปีที่แล้ว

    what is the music? so dope

  • @julliancarrillo6430
    @julliancarrillo6430 4 ปีที่แล้ว

    45° bro

  • @jutka19550603
    @jutka19550603 4 ปีที่แล้ว

    Toalet, vagyis WC 110 mm tehát 4 inch !

  • @joshuanorris9785
    @joshuanorris9785 4 ปีที่แล้ว

    cool diagram thank you!