basic service of carrier package Unit 8 tonnage
basic service of carrier package Unit 8 tonnage
มุมมอง: 30
วีดีโอ
double tap water cooler capillary block,remove blockage flush system and gas refill R134a freon
มุมมอง 3723 หลายเดือนก่อน
double tap water cooler capillary block,remove blockage flush system and gas refill R134a freon
exchange of outdoor and indoor unit and doing gas R22 store ,learn how to do pump down
มุมมอง 8313 หลายเดือนก่อน
exchange of outdoor and indoor unit and doing gas R22 store ,learn how to do pump down
Samsung split aircondition outdoor getting heat after half an hour because of distributor junction
มุมมอง 2923 หลายเดือนก่อน
solve the problem of distributor junction blockage #hvac
Always capillary flush or change before changing a new compressor in refrigerator watch the video
มุมมอง 4403 หลายเดือนก่อน
Always capillary flush or change before changing a new compressor in refrigerator watch the video
Hitachi Old model DX Centralised type 4 ton AC leakage set and gas refill R22
มุมมอง 1343 หลายเดือนก่อน
Hitachi Old model DX Centralised type 4 ton AC leakage set and gas refill R22
before fitting the compressor flushing of system and changing the capillary
มุมมอง 8403 หลายเดือนก่อน
before fitting the compressor flushing of system and changing the capillary
HVAC Kuwait videos ,split ac condenser leak se and flushing mix videos
มุมมอง 324 หลายเดือนก่อน
HVAC Kuwait videos ,split ac condenser leak se and flushing mix videos
condenssor flushing by R 410a and change capillary before changing the compressor
มุมมอง 4404 หลายเดือนก่อน
condenssor flushing by R 410a and change capillary before changing the compressor
Flushing Outdoor unit of Split ac before changing the compressor through the petrol
มุมมอง 2934 หลายเดือนก่อน
Flushing Outdoor unit of Split ac before changing the compressor through the petrol
Flushing of Special type of Capillary in Outdoor unit of O General Split Air condition
มุมมอง 1604 หลายเดือนก่อน
Flushing of Special type of Capillary in Outdoor unit of O General Split Air condition
filling petrol in condenser coil for deep clean condenser
มุมมอง 20ปีที่แล้ว
filling petrol in condenser coil for deep clean condenser
split unit pump down practical alone if nobody with you
มุมมอง 292 ปีที่แล้ว
split unit pump down practical alone if nobody with you
Gas Charging of Split Air Condition in Hindi | Videos further on Proccess
มุมมอง 1627 ปีที่แล้ว
Gas Charging of Split Air Condition in Hindi | Videos further on Proccess
Rajesh Sir teaching about compressor in hindi
มุมมอง 2.4K8 ปีที่แล้ว
Rajesh Sir teaching about compressor in hindi
In hindi Part 2 explanation of interal part of compressor
มุมมอง 6K8 ปีที่แล้ว
In hindi Part 2 explanation of interal part of compressor
Rajesh sir explaining about compressor in hindi
มุมมอง 7718 ปีที่แล้ว
Rajesh sir explaining about compressor in hindi
Ek hi dil hai kitne baar jeetoge ❤❤❤
Very hard work brother
AC ka kaam to ker rahe ho per ghalat tareeky se. EK kaam ko Bana rahe ho dosra bigar rahe ho. Ji's terha tumne cooling quail ko zameen P rakhwa h. Neeche se quail K bend Ka satiyanass ker DIA tumne. Ya quail zaror leak honge. Ager koi naran foam neeche rakhte. Ya. Table P Lita K neeche naran kapra Rakh K safari kerte to tumhari Kya Jata. Customer k sath Khair khuwahi Rakho .
good bhai😮
good bhai😮
good bhai😮
good bhai
Nice
Very good bhai❤
Yes it is bro
Nice ❤❤❤
Many many thanks
❤❤❤
Hard work bro
Good
Thanks
Right brother❤
May fhad bursli hu
Ary rijvan bhai kay bana raha ho
nice sazetion .....sir
Backpressure 130 kiye fir bhi cooling nahi h
Parvej Alam ji System m gas kabhi bhi refil kijiye to vaccum kr k qki oil system m resist krti b jisse gas ka circulation perfectaly nhi ho pata
R32
Sir Daikin ki ac h Backpressure 145 volt 230 Ampere 7.9 Fan and compressor capacitor change ker diye h Service bhi ker diye h But returning nahi aa rahi h Kya problem hoga must reply me sir please....
Parvej Alam bhai aap phle ye batao ki R32 gas h ya R22 ?
Per returning nahi aa rahi h Jisse cooling nahi h Jabki puri machine wash ker diye h Backpressure 140.ampere 7.9 volt 230 h Ab Kya Kare ki return aa jaye Please reply me sir.....
Sir Ek Daikin ki 1.5tr ki ac Jiski condenser. Cooling coil. Blower wash ker diye h Fan and compressor capacitor change ker diye h
Please subscribe my channel for Update
Sir mera naam parvej h aapka whatsapp number mil jaye to bahut hi achchha hoga
Aap question comment box m poochh sakte h aur main uska answer jald jald upload krne ki kosis karunge
Sir good video
bahut badiyaa samjhaate hai sir
screw compresr ki mother kitne h.p. ki hoti his
screw compresr ki mother kitne h.p. ki hoti his
Ji jald hi upload hogi videos
nyc sir aur video upload kriye thanx
Thanks inshaAllah i'ill upload videos ASAP
nyc sir