POLATOM
POLATOM
  • 10
  • 33 284
POLATOM - About Us
National Centre for Nuclear Research Radioisotope Centre POLATOM is manufacturer and distributor of the isotopic goods applied in medicine, research and development, industry and environment protection. Activity of the company contributes to development of the nuclear medicine, biochemistry, radiochemistry, molecular biology and other fields, which apply radioactive isotopes.
Radioisotope Centre POLATOM has been certified for conformance with the following quality standards:
- Good Manufacturing Practice (GMP)
- PN-EN ISO 9001:2009 + and the criteria of Internal Coompliance System
- Accreditation for Calibration Laboratory meets requirements of PN-EN ISO/IEC 17025:2005
มุมมอง: 135

วีดีโอ

POLATOM - O nas
มุมมอง 1392 ปีที่แล้ว
Narodowe Centrum Badań Jądrowych Ośrodek Radioizotopów POLATOM jest polskim producentem i dystrybutorem preparatów izotopowych wykorzystywanych w medycynie, nauce, przemyśle i ochronie środowiska. Prowadzi również badania naukowe oraz prace rozwojowe. Mają one charakter aplikacyjny i dotyczą radiofarmacji, chemii i techniki jądrowej a także takich dyscyplin naukowych jak radiochemia, biochemia,...
POLATOM - Elution of the Poltechnet generator
มุมมอง 4342 ปีที่แล้ว
POLATOM - Elution of the Poltechnet generator
POLATOM DOTATATE PL
มุมมอง 3424 ปีที่แล้ว
Procedura znakowania zestawu DOTATATE chlorkiem lutetu-177
POLATOM DOTATATE ENG
มุมมอง 5325 ปีที่แล้ว
POLATOM DOTATATE ENG
POLATOM 2016
มุมมอง 9757 ปีที่แล้ว
Opis
ПОЛАТОМ ПОЛГЕНТЕК Тс-99м ГЕНЕРАТОР - ИНСТРУКЦИЯ ПО ЭКСЛУАТАЦИИ - RU
มุมมอง 4999 ปีที่แล้ว
ПОЛАТОМ ПОЛГЕНТЕК Тс-99м ГЕНЕРАТОР - ИНСТРУКЦИЯ ПО ЭКСЛУАТАЦИИ - RU
POLATOM POLGENTEC Tc-99m GENERATOR Instrukcja PL
มุมมอง 2.3K9 ปีที่แล้ว
Instrukcja elucji generatora technetowego
POLATOM POLGENTEC Tc-99m GENERATOR MANUAL ENG
มุมมอง 27K9 ปีที่แล้ว
POLATOM POLGENTEC Tc-99m GENERATOR MANUAL ENG

ความคิดเห็น

  • @Cinimod105
    @Cinimod105 ปีที่แล้ว

    Would it be advisable to swab the septum with alcohol swab before inserting the vial? Assuming sufficient time is given for the alcohol to evaporate completely.

  • @osaidkhawaja4000
    @osaidkhawaja4000 2 ปีที่แล้ว

    hi .. how can we contact you directly too discuss a very important matter.

  • @jupa7166
    @jupa7166 5 ปีที่แล้ว

    "Zamknij opakowanie z zestawem do elucji" - jak dla debili... A przecież technik który przygotowuje z tego preparat musi mieć łeb na karku. A tu: "Zamknij pudełeczko, nie zapomnij o oddychaniu" :-)

  • @TheStoneTapeSimulacrum
    @TheStoneTapeSimulacrum 5 ปีที่แล้ว

    what a fucking stupid voice

  • @luckychipeya5024
    @luckychipeya5024 8 ปีที่แล้ว

    why double needle for the saline port

    • @sherrydepp176
      @sherrydepp176 2 ปีที่แล้ว

      Second needle is for air vent which helps flow of saline to vacuum vail via column

  • @JoeWong81
    @JoeWong81 9 ปีที่แล้ว

    Why did you say not to disinfect the vials that touch both the saline and eluate needles?

    • @sudo_nym
      @sudo_nym 9 ปีที่แล้ว

      Joe Wong IPA is like kryptonite for TC-99

    • @JoeWong81
      @JoeWong81 9 ปีที่แล้ว

      Sudo Nym Really? How so? I am a tech for a company called Lantheus and they tell me to swab the bacterial stats, saline vials, and collect evac vials right before eluting... is that incorrect? Thank you very much

    • @sudo_nym
      @sudo_nym 9 ปีที่แล้ว

      T99m can act like a catalyst. A reaction can occur with the dehydrogenation of IPA This can affect T99m 'grow back' and therefore yield. Not really a problem until it enters the fluid path, so it's generally safe to sanitise the tops of the 0.9% w/v saline vials, as well as the vacuum vials just prior to elution. So, for sanitising it's fine, but don't introduce IPA to the fluid path!

    • @sudo_nym
      @sudo_nym 9 ปีที่แล้ว

      Just allow it to dry first.

    • @sudo_nym
      @sudo_nym 9 ปีที่แล้ว

      From Lantheus' ''TechneLite' yield chart (online) ''Caution: Excessive use of bactericides containing alcohol may adversely affect Technetium Tc99m yield.''