The Basics of Service Checker
This video explores all of the controls, functionality and buttons that are used in Daikin's Service Checker platform both Service Checker3 and Service Checker4. I cover the what items are being displayed and what they are referencing within the program to help you understand what you should be looking at based upon the issues or symptoms.
This video is a basic guide for those who are unfamiliar with the Service Checker program or need a refresher on what they are looking at within the program.
มุมมอง: 985

วีดีโอ

Compressor Cutter - Copeland Teardown #1
มุมมอง 5298 หลายเดือนก่อน
Compressor Cutter - Copeland Teardown #1
Service Checker Control Modes
มุมมอง 1.5K8 หลายเดือนก่อน
Service Checker Control Modes
Daikin VRV Capillary Tube Sizing
มุมมอง 986ปีที่แล้ว
How to locate and analyze VRV Oil Return Capillary Tube sizing. Remember that factory recommendation is to replace all capillary tubes with OEM parts found in our Parts Database. This video serves as an educational explanation as to what the specifications mean as well as how to minimize downtime in the field. This TH-cam channel is not affiliated with Daikin or it’s entities. This is a channel...
The 3 Pillars of Daikin Service Checker Analysis
มุมมอง 9Kปีที่แล้ว
The 3 pillars of Daikin Service Checker Analysis. This video focuses on how to use the basics of refrigeration to troubleshoot Daikin Service Checker Data. Regardless the number, high or low, we can determine what is happening within the system and investigate at a magnified level as to the issue. This TH-cam channel is not affiliated with Daikin or it’s entities. This is a channel focused on s...

ความคิดเห็น

  • @MelodyMan69
    @MelodyMan69 3 วันที่ผ่านมา

    Daikin Service Checker is rubbish when compared with the LG System. Look up LGMV (Multi View) and you will see.

    • @Username-ng8jy
      @Username-ng8jy วันที่ผ่านมา

      The mistubishi one is better than lg

    • @MelodyMan69
      @MelodyMan69 วันที่ผ่านมา

      @@Username-ng8jy Yes its good and covers about the same as LG do. I worked at Daikin 21 years and LG for 17 years but don't have hands on experience with the ME Product. Only stories from their Techs.

  • @shirvonseemungal7719
    @shirvonseemungal7719 หลายเดือนก่อน

    How do we measure subcool on a vrv

  • @travisburks628
    @travisburks628 หลายเดือนก่อน

    Can you repost the input mode list. I had it but I somehow lost it.

  • @mallkomoha6823
    @mallkomoha6823 2 หลายเดือนก่อน

    Can rebroadcast the video in metric please?? I mean in degree Celsius.

  • @BleedingEdgeHVACR
    @BleedingEdgeHVACR 2 หลายเดือนก่อน

    Sorry I’m confused is discharge superheat calculated by taking Discharge line temp-Discharge sat temp or Discharge line temp-Liquid sat temp?

  • @jorgevalladares179
    @jorgevalladares179 4 หลายเดือนก่อน

    Are the examples shown, reflect a system running on heat?

    • @RomanBaugh
      @RomanBaugh 3 หลายเดือนก่อน

      Heat, Cooling, heat recovery it’s all relevant as long as you know the correct locations of where to measure these temperatures.

  • @garypoplin4599
    @garypoplin4599 4 หลายเดือนก่อน

    1:34 - Where do you put your probes to get the numbers for calculating discharge superheat? My understanding of the discharge superheat calculation is discharge line temperature less liquid line pressure (converted to temperature). Is that right?

    • @RomanBaugh
      @RomanBaugh 3 หลายเดือนก่อน

      Discharge superheat is measured using discharge line temperature 6” down stream of compressor then subtracting it from liquid line temp converted to saturation temp. 180-110 = 70 DSH.

  • @jasonjohnsonHVAC
    @jasonjohnsonHVAC 5 หลายเดือนก่อน

    Great video

    • @RomanBaugh
      @RomanBaugh 5 หลายเดือนก่อน

      Glad you enjoyed it

  • @user-hc1in7io2t
    @user-hc1in7io2t 6 หลายเดือนก่อน

    How do I view the refrigerant piping diagram?

    • @RomanBaugh
      @RomanBaugh 5 หลายเดือนก่อน

      Unfortunately you will have to reference the refrigerant piping diagram in the Service Manual as Service Checker currently does not have an active flow diagram like other manufacturers.

  • @user-hc1in7io2t
    @user-hc1in7io2t 6 หลายเดือนก่อน

    How do I view the refrigerant piping diagram?

  • @user-gi9yj6ru5o
    @user-gi9yj6ru5o 6 หลายเดือนก่อน

    great bit of info from you as usual

    • @RomanBaugh
      @RomanBaugh 5 หลายเดือนก่อน

      Thanks!

  • @buggedmechanics
    @buggedmechanics 6 หลายเดือนก่อน

    Great video

    • @RomanBaugh
      @RomanBaugh 6 หลายเดือนก่อน

      Glad you enjoyed it

  • @Scottyboyhvacdude
    @Scottyboyhvacdude 6 หลายเดือนก่อน

    I cant believe ive looked at this for 14 yrs and had no idea what these control modes were. Many thanks bro

    • @RomanBaugh
      @RomanBaugh 6 หลายเดือนก่อน

      Glad I could help!

  • @hamdyhelal4000
    @hamdyhelal4000 6 หลายเดือนก่อน

    great info, thanks, can you share service manual no.

    • @RomanBaugh
      @RomanBaugh 6 หลายเดือนก่อน

      Yes I can

  • @jevonhoward
    @jevonhoward 6 หลายเดือนก่อน

    So I'm still on service checker 3. Is outdoor suction temp(line item 77) air entering outdoor coil? I would want to use suction pipe temp(line item 79) minus evaporator temp to calculate superheat correct? Do I not have operation mode on service checker 3?

    • @RomanBaugh
      @RomanBaugh 6 หลายเดือนก่อน

      What is the model of your equipment? Based upon the model it may have 2 suction temp sensors. Yes thats correct VRV4 and newer is the only models with Control Modes.

    • @jevonhoward
      @jevonhoward 6 หลายเดือนก่อน

      @@RomanBaugh REYQ144TAYDU

  • @anasal-muhur3587
    @anasal-muhur3587 6 หลายเดือนก่อน

    great, thank you

    • @RomanBaugh
      @RomanBaugh 6 หลายเดือนก่อน

      Glad you liked it!

  • @guuuuustaf
    @guuuuustaf 6 หลายเดือนก่อน

    Do you know the process of Daikin minisplit, how do they calculate evaporating temp and condensing temp. Since they do not have pressure transmitters. Only discharge probe, ev probe and condensing probes, and air thermistor probes. Do they calculate evaporating and condensing temperatures via the compressor load ampere, and also take into account the heatexchanger probes? Its bugging me for real. Hope you have somewhat of an answer.=)

    • @ryanbrown7134
      @ryanbrown7134 6 หลายเดือนก่อน

      Short answer is they don’t. Thermistor data is all that is used to control the motor speeds and valve pulses. At least that’s what is taught in the mini split class.

    • @guuuuustaf
      @guuuuustaf 6 หลายเดือนก่อน

      @@ryanbrown7134 Then how can they get correct sh and sc? Its been bugging me how are they actually know how to adjust the eev. Some of the data needed for correct sh, sc is unknown. They must use ampere drawn by the compressor too trying to get somewhat of correct ev pressure and condensing pressure... 😁

    • @ryanbrown7134
      @ryanbrown7134 6 หลายเดือนก่อน

      @@guuuuustaf It bothered me too when I first started working on them. They don’t monitor superheat or subcooling. They may have an algorithm that determines wet operation with compressor current and discharge temp but I doubt it. Even if they did, they wouldn’t tell us anyways. Other than the logic, mini splits are very simple units.

    • @guuuuustaf
      @guuuuustaf 6 หลายเดือนก่อน

      Haha okeey thank you for the answer=). may be therefore they often have two accumulator tanks beside compressor. Cause the sh cant always be 100%.They are indeed very simple. The logic as you say is the more tricky part. @@ryanbrown7134

    • @Jonathan-li1xh
      @Jonathan-li1xh 6 หลายเดือนก่อน

      If the units don’t have the pressure sensor , it should have thermistor at the evap and at the condenser coil . These temperature will be used for evap temperature and condensation temperature instead pressure reading converted into sat temperature.

  • @wojciechkobierski1913
    @wojciechkobierski1913 6 หลายเดือนก่อน

    Is there any manual that describes what exactly happens during each mode?

    • @RomanBaugh
      @RomanBaugh 6 หลายเดือนก่อน

      Yes all of these items are in the appropriate service manual for that model unit.

  • @bjaquez27
    @bjaquez27 7 หลายเดือนก่อน

    Thank you Roman. We been ordering for months now. Sometimes only get a solenoid valve and coil only. I always tell them send me the entire assembly.

    • @RomanBaugh
      @RomanBaugh 6 หลายเดือนก่อน

      Glad to help

  • @guuuuustaf
    @guuuuustaf 7 หลายเดือนก่อน

    Great explanation!

    • @RomanBaugh
      @RomanBaugh 6 หลายเดือนก่อน

      Glad it was helpful!

  • @dcfabrication2097
    @dcfabrication2097 8 หลายเดือนก่อน

    We appreciate you Roman

    • @RomanBaugh
      @RomanBaugh 6 หลายเดือนก่อน

      Thanks!

  • @DaneSetser-nn9xc
    @DaneSetser-nn9xc 8 หลายเดือนก่อน

    I’ve got a total of 9 systems of 4X heat recovery units. We have had multiple issues and lost compressors. Your video made me dive deep into these systems. One system in particular is running a high DSH 90-100. SSH is within range no higher that 32 sometimes drops less in five. Subcool is within range. I did an oil differential across the suction line and was getting 7F then jumped up to almost 40F. Do you have any more info. Also where did you get the 30 modes local Daikin rep doesn’t have it.

    • @RomanBaugh
      @RomanBaugh 8 หลายเดือนก่อน

      Sounds like oil traps within the building. High DSH levels with normal range SSH and Subcooling means your compressors are low on oil. Sounds like piping errors or discrepancies. Meaning there are piping rules broken causing oil to become trapped in the system. Your local Daikin Rep will not have that list, as I translated it from Japanese. Daikin Japan is the only one with the list prior to now.

    • @DaneSetser-nn9xc
      @DaneSetser-nn9xc 8 หลายเดือนก่อน

      Thank you I’ll start looking at the piping.

  • @robertbethell4795
    @robertbethell4795 8 หลายเดือนก่อน

    Opening up a compressor

    • @RomanBaugh
      @RomanBaugh 8 หลายเดือนก่อน

      Yes sir

  • @travisburks628
    @travisburks628 8 หลายเดือนก่อน

    Where can we find the operation code list? I have been looking through the service manual. Iis there something you can share?

    • @RomanBaugh
      @RomanBaugh 8 หลายเดือนก่อน

      I will be posting it soon with an updated version.

    • @travisburks628
      @travisburks628 8 หลายเดือนก่อน

      I really enjoy your videos.

    • @dawain
      @dawain 2 หลายเดือนก่อน

      Wow! I am in❤ w/ this Guy 🧠….

  • @hvacgirlo
    @hvacgirlo 8 หลายเดือนก่อน

    VRV legend Roman!!

    • @RomanBaugh
      @RomanBaugh 8 หลายเดือนก่อน

      I dont know about all that. Just a guy who is passionate about VRV/F

  • @cedric0057
    @cedric0057 8 หลายเดือนก่อน

    I have worked for Daikin for many years in France and have never had this information. I've been seeing this number and trying to say "what does that mean" for a long time. Many thanks for your work and for sharing. good game.

    • @RomanBaugh
      @RomanBaugh 8 หลายเดือนก่อน

      I am glad you liked the video! More to come!

  • @tom24057
    @tom24057 8 หลายเดือนก่อน

    More VRV content would be great Roman!!? 😅😅

    • @RomanBaugh
      @RomanBaugh 8 หลายเดือนก่อน

      You got it!

    • @tom24057
      @tom24057 8 หลายเดือนก่อน

      @@RomanBaugh awesome. Here in the UK Daikin aren’t forthcoming with this information. Even their Multichecker training courses are average at best

  • @ashleydavies7863
    @ashleydavies7863 9 หลายเดือนก่อน

    Are the temperature figures in Fahrenheit or Celsius? As I'm in the UK

    • @RomanBaugh
      @RomanBaugh 8 หลายเดือนก่อน

      Fahrenheit good sir

  • @marcoferreira226
    @marcoferreira226 9 หลายเดือนก่อน

    I have a question are your Temps F or C?

    • @RomanBaugh
      @RomanBaugh 8 หลายเดือนก่อน

      Fahrenheit

  • @LC-qi5ff
    @LC-qi5ff ปีที่แล้ว

    How does overcharge cause low oil in compressor?

    • @tom24057
      @tom24057 10 หลายเดือนก่อน

      Flushes out oil

    • @RomanBaugh
      @RomanBaugh 8 หลายเดือนก่อน

      System never runs the compressor over half speed causing velocity to be low not allowing refrigerant to bring oil back from the indoor units. Couple that with liquid flood back then compounds the issue removing any remaining oil from the compressor.

  • @user-wz6fw5sm7f
    @user-wz6fw5sm7f ปีที่แล้ว

    Hi Roman, great video could you advise of these figures you refer to in deg C i.e. DSH range (27 to72), SSH range (3.6 to 32) & LSC range (11)

    • @RomanBaugh
      @RomanBaugh 8 หลายเดือนก่อน

      Fahrenheit my friend

  • @omegma87
    @omegma87 ปีที่แล้ว

    Thank you.

  • @prowesstv
    @prowesstv ปีที่แล้ว

    Bro got me locked in for the deep dive then only has two videos 😅😅

    • @RomanBaugh
      @RomanBaugh 8 หลายเดือนก่อน

      The wait is over

  • @WallaceRoseVincent
    @WallaceRoseVincent ปีที่แล้ว

    Wish you had the actual parts on hand.

    • @RomanBaugh
      @RomanBaugh 8 หลายเดือนก่อน

      Of course we all do, however as a technician we have to just wing it sometimes

  • @jeffendrulat3530
    @jeffendrulat3530 ปีที่แล้ว

    Thanks Roman..... Best 20 minutes that I spent today!

  • @Didik-cq8wy
    @Didik-cq8wy ปีที่แล้ว

    Trimaksih bos

  • @ping_me1vp
    @ping_me1vp ปีที่แล้ว

    That's soo excellent thanks a million

  • @nguyennam880
    @nguyennam880 ปีที่แล้ว

    Looking forward to you sharing your knowledge related to data analysis checker. Thanks you.

    • @RomanBaugh
      @RomanBaugh 8 หลายเดือนก่อน

      The wait is over

  • @karaors8970
    @karaors8970 ปีที่แล้ว

    Nice bro.🤳🛠️🧿👍

  • @phillipcase8036
    @phillipcase8036 ปีที่แล้ว

    Thank you for your informational video it shows these units can be worked on and we just need to dig deeper

  • @HVACR_VINYLS
    @HVACR_VINYLS ปีที่แล้ว

    Another roman video. Oh shit yeh 💪

  • @HVACR_VINYLS
    @HVACR_VINYLS ปีที่แล้ว

    Hey Roman. When I’m using my service checker on a VRV 4. I have noticed the eev pulses have 2 sets of data. Eg it has upper heat exchanger eev pulses, and then upper heat exchanger eev US pulse. What does the US dictate? I don’t use it in my diagnosis, I’m just curious to what it refers too.

    • @RomanBaugh
      @RomanBaugh ปีที่แล้ว

      Yes there are two different sets, however do not us the (US) valve pulses as they are not for our market and will be misleading.

    • @HVACR_VINYLS
      @HVACR_VINYLS ปีที่แล้ว

      @Roman Baugh thanks legend. Appreciate it

  • @Scottyboyhvacdude
    @Scottyboyhvacdude ปีที่แล้ว

    How long before you have to take this down?

    • @tom24057
      @tom24057 ปีที่แล้ว

      Why?

    • @RomanBaugh
      @RomanBaugh 5 หลายเดือนก่อน

      Still up Scott 😂

    • @Scottyboyhvacdude
      @Scottyboyhvacdude 5 หลายเดือนก่อน

      @@RomanBaugh I only say that because there's been some other helpful daikin content that was taken down. I don't understand the secrecy. We as technicians need any tools we can get, thank you!!

  • @epicone2449
    @epicone2449 ปีที่แล้ว

    More videos please. Good job 👍🏼 I thought VRV 3 and VRV 4 have different ranges in permissible values

    • @RomanBaugh
      @RomanBaugh 8 หลายเดือนก่อน

      No same ranges as they share similar compressors.

  • @cchurch816
    @cchurch816 ปีที่แล้ว

    Also sensors and transducers. How to verify they work right

    • @jorgevalladares179
      @jorgevalladares179 4 หลายเดือนก่อน

      Without getting into the math, Daikin has two apps that can help you convert that. Daikin tech and Daikin services, it’ll convert dc voltage to pressure (vise versa) and temps to ohm (vise versa). Then get gauges or temp probes and see if they correlate.

  • @cchurch816
    @cchurch816 ปีที่แล้ว

    But keeping them videos comming.

  • @cchurch816
    @cchurch816 ปีที่แล้ว

    U sound like u think all techs have basic schooling in refrigeration theory.

    • @epicone2449
      @epicone2449 ปีที่แล้ว

      You need to know the basics before diving into VRV. Like experienced in service on package units or split systems

    • @cchurch816
      @cchurch816 ปีที่แล้ว

      ​@@epicone2449 looked for the dsh, sc and sh on a daikin fit heat pump couple days using the daikin btsc app. The symbols arnt matchin on the app. Reverted to just using to probes. Went after the dsh and sh in heating mode. Looked normal. Last tech suspected low charge after the tstat error history shows low pressure trip. Found the data wire was grounded at the equipment chasis and corrected it.

  • @johnchiarello1375
    @johnchiarello1375 ปีที่แล้ว

    Great video

  • @alanwang2900
    @alanwang2900 ปีที่แล้ว

    Great video! Thanks for sharing. Are these numbers different when unit in heating mode? I always see outdoor coil iced up after the main eev, and from service checker, it shows the valve 3000 pls

    • @RomanBaugh
      @RomanBaugh ปีที่แล้ว

      The measurements discussed in this video are universal between all modes, however where we are measuring these temperatures changes. Measuring subcooling in cooling mode is using different temperature measurement locations than in heat mode.

    • @alanwang2900
      @alanwang2900 ปีที่แล้ว

      @@RomanBaugh thanks, hope you could do a video the troubleshooting when unit is in heating mode. 🙏

  • @americanpatriot9942
    @americanpatriot9942 ปีที่แล้ว

    Can we use this same method with all vrfs systems? Thanks in advance also great info god bless!