- 153
- 347 346
ZOYI ZOTEK multimeters
เข้าร่วมเมื่อ 24 ต.ค. 2022
Experience precision with ZOYI/ZOTEK Instruments. From cutting-edge instrumentation to essential tool accessories, our innovative designs and manufacturing ensure top-notch quality. Elevate your work with our professional-grade products and expert guidance. Join us as we pave the way to a better future.
Internet influencers, claim your complimentary samples today. Contact us to unlock excellence!
zotekmultimeters@gmail.com
Internet influencers, claim your complimentary samples today. Contact us to unlock excellence!
zotekmultimeters@gmail.com
วีดีโอ
How to update the firmware on ZOYI ZT-MD1?
มุมมอง 6942 หลายเดือนก่อน
How to update the firmware on ZOYI ZT-MD1?
How to adjust the vertical data on an oscilloscope
มุมมอง 6634 หลายเดือนก่อน
How to adjust the vertical data on an oscilloscope
How to use the trigger system of an oscilloscope?
มุมมอง 6744 หลายเดือนก่อน
How to use the trigger system of an oscilloscope?
How to use ZT-703S Oscilloscope Multimeter?
มุมมอง 9K5 หลายเดือนก่อน
How to use ZT-703S Oscilloscope Multimeter?
How to update firmware for ZOYI ZT-703S?
มุมมอง 1.4K5 หลายเดือนก่อน
How to update firmware for ZOYI ZT-703S?
ZOYI MULTIMETER SHELL PRODUCTION PROCESS
มุมมอง 836 หลายเดือนก่อน
ZOYI MULTIMETER SHELL PRODUCTION PROCESS
Когда вы получаете посылку с ZT-102L.
มุมมอง 28810 หลายเดือนก่อน
Когда вы получаете посылку с ZT-102L.
How to Use a Multimeter When You Get the ZOYI ZT-219
มุมมอง 1.5Kปีที่แล้ว
How to Use a Multimeter When You Get the ZOYI ZT-219
ZOYI ZT-QB1 Clamp Multimeter Tutorial: How to Use and Measure Like a Pro
มุมมอง 1.2Kปีที่แล้ว
ZOYI ZT-QB1 Clamp Multimeter Tutorial: How to Use and Measure Like a Pro
A multimeter has the function of an oscilloscope, just a color screen multimeter for money
มุมมอง 1.3Kปีที่แล้ว
A multimeter has the function of an oscilloscope, just a color screen multimeter for money
Looks good however how it works in reality , that is something we should check.
Appealing futuristic style. Nice item!❤
Интересный приборчик. А кнопки где режимов?
請貴公司考慮於下次版本升級時,考慮除原有L,C,R,Q,D再納入X(電抗:XL感抗與XC容抗)及Z(總阻值)二個輔助參數!因為fniris ST-1就有這兩個好用參數顯示的😊
好的。谢谢建议😀
Definitely cool. Something to FLIP over!
Muhahaha 👍 Paul you Crack me up.Nice work ZOTEK/ZOYI !
can an arbitrary waveform be generated that can be loaded from a PC?
If ya want a pocket meter small like this. Least get ya a Sanwa PM3 or something like that. Basically same size. Lil folding book case. An atleast some quality from the Japanese Sanwa brand. Vs this non existent brand. An no telling what the rating truly even is etc. this is junk
frmware version 1.42 still has a lot of bugs related to auto range. The function still often sets the wrong waveforms and after pressing the auto range key, the sample HD function turns off by itself. when are you working on releasing the next version of the firmware?
Thanks for sharing an overview of the Fair. Your product range is wide, trendy, and practical. ❤
@@pault6533 Many thanks for your support 🤗
Thank you very much
I'd love to test it in detail, and who knows, maybe I'll even buy it. But with so many multimeters already in my possession, it's hard to justify. To be honest, the multimeter I use the most right now is the Aneng 8008. Out of all the instruments I own, Aneng has proven to be the most precise.
UPDATE. Oct 2024. With the new 1.4.2. firmware update we now have a third trace available in the form of "FFT" (FAST FOURIER TRANSFORM) availability in glorious RED colour. It replaces the FORMAT position in the fourth menu which was used to delete the stored screen shots. It changes the "X" axis from time to frequency and as such changes the display to that of a a spectrum analyser. Frequency is plotted along the x-axis and amplitude is plotted along the y-axis. FFTs often look like a series of mountain peaks. The horizontal location of peaks indicates which frequencies are strongly present in the W/F. The valleys show which frequencies are absent. I tried this with the built in calibration sig gen on all the available W/Fs and it shows the strongest frequency is the prime 1 KHz followed in the case of square waves by diminishing amplitude peaks at each successive square wave. Quite useful when checking audio problems etc. The second change in the menu is in the 2nd row, what used to be the trigger position, is now "SAMPLE" with two choices, HD & PEAK.
Thermography,how precise is for finding smd components faults , overheating?
Non-contact voltage detectors are a welcome tool in every electrician's kit, but only if they are 100% reliable, which no electronic measuring instrument truly is. Electronics always fail at some point. That's why I always keep the good old voltage tester with a small light bulb in my toolkit as well.
that device should be tested more deeply and detailed .
is it true what ker9837 says below regarding auto finding signal in oscilloscope mode. Almost purchased this unit two days ago was very much interested in reviewing it and testing it independently. It looks that lack of no enough money at my account gave me more time to make this question. If problem is real , can it be addressed and fixed in firmware update ? Does device supports firmware updating by user ?
How to reset settings pls
It's very annoying that the screen turns off every two minutes.
I’m guessing that’s the default value for battery savings. Should be adjustable in the settings
@@TheConner322 Ok I found it, set BL time to off. Thanks.
Please fix the auto shutdown so that the tweezers don't turn off while being used.
Will you be releasing v1.8 to add Rs export soon? This column is missing in the data.
Hindi me kariy
Отлично например!
Is there going to be an update that fixes the Auto function on the oscilloscope? With the latest software, seven times out of ten it won't recognize the signal and you have to manually search the correct signal. So this function is useless. Altought most used function on oscilloscopes.
Is there going to be an update that fixes the Auto function on the oscilloscope? Seven times out of ten it wont recognize the signal and you have to manually search the correct signal.
XEAST XE-703s confirmed to be compatible with ZOTEKs ZT-703s firmware ;-)
Some diodes not detected in the circuit( Multimeter defines them correctly.
Mujhe buy karna hai I'm india
I've been using this unit for several years, after decommissioning my old Voltcraft/Metex M80 due to the lack of contrast on its LCD display. I picked it from the Aneng brand, but it's exactly the same as the ZT-X model, even labeled ZT-X on the PCB. Generally, I'm very pleased with the quality and functionality of this unit, but it also has a few shortcomings. For example, it should have an internal boost SMPS converter for the LED backlight, as this would help maintain the backlight even when the batteries are heavily used. Another shortcoming is the lack of a REL (relative) function for small resistance measurements to compensate for probe resistance, which is a standard feature in mid-range multimeters from other brands. Additionally, it incorrectly registers an AC offset in DC voltage measurements. When measuring in the mV/AC mode selected manually and then connecting to, for example, 20VDC, the unit reboots immediately. :( Despite these issues, the ZT-X meter is a very good piece of equipment but could benefit from minor improvements, such as an inductance counter and ESR checking while measuring capacitance. Currently, I'm testing a newly purchased ZOYI ZT-703S unit, and aside from minor issues with housing fit, it's really a great piece of equipment, especially considering its price. Best wishes to the whole ZOTEK team!
Thank you so much for your feedback and support of our products. Your insights are greatly appreciated, and I'll be sure to share them with our R&D team. We hope you'll stay tuned for our upcoming product releases. Wishing you all the best!
EBTN
Nice bar graph!
3AA cells is a good because 1.2 V rechargeable cells work better than a meter that only accepts two. This meter has a very good REL feature because it works across most functions, not just C or R. Mine is extremely accurate too!
Прикольно!!!! Занятный приборчик. А куда вы пропали с Алиэкспресс? Как купить вашу продукцию в России?
Hello! I suggest to add the Inductance measurement to all multimeters. The three passive components in electronics are resistor (R), capacitor (C) and inductor (L). In relation to the frequency, an inductor can also be measured with capacitor masurement, but needs a bit of calculation after the measurement. Thank you for considering!
This equipment got diode anode and cathode test problem. How to solve it.
Please add a brief beep when a diode is detected.
Good idea!
How is its accuracy compared to branded multimeters
The series resistance is not logged. Please add "Rs" column to the data export. Currently "No. Type Level Frequency Value D" are exported. Also, OL (Over Limit) is logged as ØL (the number zero).
It would be great if you showed the calibration process😅
zotektools.com/firmware-update/
This link goes to a multimeter firmware. I think you wanted us to go to /firmware-update-md1 for the file 🌹
Update details: 1. Added the functionality to save and export measurement data. 2. Improved the accuracy of low resistance measurements. 3. Corrected spelling errors in English words.
Thank you for adding description how to activate and use data export @1:04. This is a very good upgrade!
@@pault6533😀
Hello, Can you add a automatic data hold function to the multimeter, in the future updates? So that, when i probe someting, i dont have to look the screen and it would hold the highest value until reset. There is already the hold button. Thanks
Website please
zotektools.com/firmware-update/
zotektools.com/products/zoyi-zt-md1/
THIS IS THE LINK OF FIRMWARE UPGRADE.
I really like this device, but the "D" values it provides are incorrect. Does your v1.6 firmware upgrade fix this? Please provide a link to the firmware files.
Please try to upgrade first. If there is still any problem, please contact me. Thank you very much!
How do I find the firmware upgrade? Does this fix the incorrect D values for capacitance?
zotektools.com/products/zoyi-zt-md1/
This is the link of firmware upgrade. zotektools.com/products/zoyi-zt-md1/
The D-value measured by MD1 will not be inaccurate; however, there will be slight differences in the D-values for each bridge. The firmware update optimizes the measurement speed for high resistance values.
@@zotekmultimeters4774 Thank you for adding the file today. The user manual PDF link is working now too.🌹
@@zotekmultimeters4774 Thank you for explaining the differences in D. As for R, v1.5 did not work very good above 1Mohm. With v1.6, it measures very well. I also tried a 20Mohm resistor. The display showed the correct value for Rs=20.0M, but displayed OL in the main window. Language still incorrectly spelled Languege in the menu.
You even hate rest of the world, every1 know a little of English language. But you have to use AI voice to follow subtitle. Look at me I am bad in English language but still can talk , can understand and indeed people understand me.
You are right. Using AI voice is not a good idea. I noticed that your channel is about technical reviews. Are you interested in reviewing our products?
@@zotekmultimeters4774 there was no notification about your replay to my comment. Have no idea how and why I returned to this video and checked comments. Yes I am interested in reviewing your products and already contacted zotek via official mail. We made some agreement about how it will go with me testing and reviewing your products.
This taught me nothing.
Обладаем таким девайсом. Сказка! Он волшебный.
Hola tengo la V55 alguien tiene la V58????
Well, that's not possible, you have to use the second generator in the OutPut Setting MENU