WoW! Warriors of Warmth Plumbing Happy to help
United Kingdom
เข้าร่วมเมื่อ 26 ก.ย. 2013
WoW! are a team of charity heating engineers, donating their trade to fight fuel poverty with the support from heating manufacturers. Jonathon Hallam the man behind WoW! is a lecturer & Heating engineer offering free training across the country. For revision ppts, handouts and learning material please visit the warriorsofwarmth website. Thank you for viewing, thank for subscribing & thank you for donating your trade & materials
For further information or free training material visit;
warriorsofwarmth.co.uk/
Thank you sponsors.
Alpha heating
Lawton tubes
Stelrad
John Guest
Many thanks
Jonathon Hallam
All work undertaken has been for free to gain educational footage or visual aids
For further information or free training material visit;
warriorsofwarmth.co.uk/
Thank you sponsors.
Alpha heating
Lawton tubes
Stelrad
John Guest
Many thanks
Jonathon Hallam
All work undertaken has been for free to gain educational footage or visual aids
วีดีโอ
Old copper Combination Fortic cylinders!
มุมมอง 97หลายเดือนก่อน
Old copper Combination Fortic cylinders!
Fault finding Viessmann compact vitodens 100
มุมมอง 3862 หลายเดือนก่อน
Fault finding Viessmann compact vitodens 100
New heating boiler installation and up grade
มุมมอง 3503 หลายเดือนก่อน
New heating boiler installation and up grade
How to test synchronous motorised valves & pumps
มุมมอง 5643 หลายเดือนก่อน
How to test synchronous motorised valves & pumps
Servicing & fault finding on gas multi point
มุมมอง 3133 หลายเดือนก่อน
Servicing & fault finding on gas multi point
Glow worm, compact, fault finding, servicing! No hot water, No heating
มุมมอง 2.1K6 หลายเดือนก่อน
Glow worm, compact, fault finding, servicing! No hot water, No heating
Explaining Hydrostatic pressures in heating & hot water systems
มุมมอง 4556 หลายเดือนก่อน
Explaining Hydrostatic pressures in heating & hot water systems
Maintenance jobs around a hotel in the Peak District
มุมมอง 3566 หลายเดือนก่อน
Maintenance jobs around a hotel in the Peak District
Doncaster scouts (Carcroft) charity project
มุมมอง 1556 หลายเดือนก่อน
Doncaster scouts (Carcroft) charity project
Installing a Navien boiler in a loft space
มุมมอง 2417 หลายเดือนก่อน
Installing a Navien boiler in a loft space
Making a copper coil, spring, bending copper using only water
มุมมอง 1.4K7 หลายเดือนก่อน
Making a copper coil, spring, bending copper using only water
Calculating servicing installing cold boosted systems
มุมมอง 1497 หลายเดือนก่อน
Calculating servicing installing cold boosted systems
How to size air conditioning units, rule of thumb
มุมมอง 747 หลายเดือนก่อน
How to size air conditioning units, rule of thumb
Plumbers safe electrical isolation, proving device & voltage indicator
มุมมอง 2217 หลายเดือนก่อน
Plumbers safe electrical isolation, proving device & voltage indicator
Free plumbing, gas, refrigeration learning materials on our website
มุมมอง 1278 หลายเดือนก่อน
Free plumbing, gas, refrigeration learning materials on our website
How to service, test, fault find & clean solenoid valves and resistance readings
มุมมอง 5988 หลายเดือนก่อน
How to service, test, fault find & clean solenoid valves and resistance readings
Is range rating still needed if the Opentherm thermostat is modulating the flow temperature?
@@DunkingJaffaCakes no, plus that's usually hot weather compensation on too
Amazing work from all involved.
@@katieearl789 thanks Katie, ur awesome x
Great video thanks a lot.
Hi when you buy a replacement heater element with it come with a fiver washer ? Also what jointing compound to use ? Thanks
@@yuriflynn2477 yes put boss white either side of the washer NOT the thread
i want to buy a home..but it has a gas fireplace....I want to remove it after i buy the home and replace it with a pellet stove..how can i do this safely?
Were do you find this product for sale?
@@mrnu1147 friend bought this from Online might of been Victoria plumb?
Great Video what happened to the FGA test you promised to do at the intro?
This was over 15years ago, the FGA I mention in other vids sorry dude
oes anyone know where a can get a 3/8" supa tap washer please?
Make one from larger washer or leather
@@warriorsofwarmth Thanks. ,I guess you don't know what a Supa tap washer is? I can probably bodge a new insert . But I'm trying to find a replacement first.
@@BUGGY71 it's just a normal washer
Great stuff Jonhathon, by their fruits shall you know them, as someone once said :)
Thanks Mark
Well done, you guys have done a great job. Well deserved 🍺
Thanks 🙏 very grateful for the feedback
You know a true engineer when he's over the moon with a few new gadgets XD
Love it, deffo could pull off the advertising plumbing channel angle 👍
dude needs an unvented cylinder!
lolz hilarious. I'm a Makita guy myself, lost so much money on fake batteries i just take the hit and buy decent OEM ones, it saves money long term.
Me too
Righteous & happy :) Dewalt are shaking in their boots haha. Nice 👍 Yup, those knockoffs are really tempting 😓I was looking at a "Mirka" orbital sander, almost pulled the trigger on it but thought better not risk it. I feel like changing my mind now 😂
Thing is it all helps achieve ur full collection
Love it
Thanks 🙏 very grateful for your feedback
😊
Why does it have 5 pipes if it’s system boiler
Some Viessmann boilers have DHW primaries so they can modulate lower for the heating and ntc modulation for the dhw demand
@@warriorsofwarmth why would it want it to modulate lower for heating surely the zero governor is in place for modulation and doesn’t it turn off automatically when it reaches temperature needed
@@UFSLDN because the boiler has tow flow temperatures
Great and simple explaination Johnathan, cheers.
Now look at the Navien oil boiler? Completely different from competitors
Johno, my customer has 15mm primary flow and returns going to a vented hot water cylinder, could I use these if I wanted to changed to unvented, your fan Roo.
Yes many use 15mm, it's only requiring a small flow rate any way
@@warriorsofwarmth That's really great, thanks Johno. What about the cold inlet and hot out, can they be 15mm ? or must they be 22?
@@robbie2awesome 22mm ideally for H & C flow rates
@@warriorsofwarmth Thank you Johno, you are a scholar and a gentleman!
Couldn't you get the same (and better) results by cleaning them in an Ultrasonic cleaner?
This method is cheaper for plumbers who have the chemicals already
@@warriorsofwarmth Fair enough, but better results with ultrasonics & if so, less worry of problems if re used, so maybe cheaper and better in the end.
Great, thank you, saved me a heap of time watching this video! 🎉
Glad I can add support
The whole point of putting down Beading or Quadrant is to replace Silicone. Why would you apply silicone again along with the Beading or Quadrant? You will still have the issue with black mould if you do this. Also, this has got to be one of the most annoying tunes ever
Would you recommend just using adhesive behind and no silicone ON the quadrant?
Great content👌 I'm having drama with a Betacom 3. Changed Diverter cartridge, but heating circuit is still half open on HW demand..I'm now thinking faulty Harness🤔(i.e. is it not fully moving to HW) or Dirt in the hydrobloc...I'm stumped😮
Check demand
@@warriorsofwarmth all good there, recognises demand, fires up, heat goes around Plate and down the Flow....HW is warm at best, isolate the Flow= Instantly Hot.
Totally agree on the fuel poverty, i see some shocking poverty. Scares me how little safety net there is these days and the government paints a picture of people milking it....the reality is the polar opposite
Can I ask where the gas pressure test point is on the sustain....i can't find it on the gas valve
Look on the gas isolation valve underneath
Yeah seen that one, normally there's one on the gas valve itself, I went to a f28 fault two days ago and couldn't find the pressure point on the gas valve to see if it was opening up
What to do when F13 flashing on the screen?
Temperature sensor? Maybe no airlock too?
@@warriorsofwarmthThank you for your answer. shall I switch the boiler off and check if that help? Or it won't change anything and I should call engineer? Anything else what I could try on my own?
@@karolinalilith7273 yes u should really
do they do a floor level exit macerator? shame it goes up only to go under ground
Hi mate, I have hot water but heating doesn't come on when set temp on thermostat. Any ideas thanks
Sorry not an engineer. Thought in case a settings fault.
Could be the diverter valve or nondemand
Ok. Now please someone tell me some names of brands that has weather compensation.
All of them, should offer it
Worked in power plants for 40 years generating electricity. Retired for 8 years now.
Wish I had a career working in power plants, domestic is hassle!
Nice one mate 👍
Its really interesting, maybe Ill do f-gas and heat pumps.
I've seem more of these controllers in plant rooms than when on my fgas and air source heat pump course. Maybe the course I went on was bad😂. Seem similar controllers on pumps and pressurisation units. There's some free air source heat pump courses. As for fgas the best priced one I've seen is in potters bar. Ellis training.
Great explanation 👍🏻
Thanks I appreciate ur feedback
I thought this video was about how to score goals with headers to have a low loss rate. 😢
my man, you are legend!
Sorry it took so long been a tough week
@@warriorsofwarmth Johno what does the outcome of 1.89 litres refer to? Is it the capacity that the system needs in order to maintain a delta T of 20 C or something else, please forgive my ignorance, your fan Roo
That figure will help u select a LLH
@@warriorsofwarmth I can see they are all rated just like boilers, some listing the maximum flow rate and others listing the pipe size. Its relatively simple now, I need 1" pipe size and at least 45Kw with a max flow rate around 1.89 L/min, thanks man!
lesson 3 Mr Dao
2 weeks after its dry and peeling off
Did u dry the surface?
I've got me water regs today so this is a very helpful video well in for posting it pal five stars
Thanks dude! Hope u passed
After poking the gas hole with a needle still not working no gas at all coming out…
Read the MI ? Stroll through fault finding chart, could be the supply tube or tap
@@warriorsofwarmthok it works but very very faint fire very weak
Excellent 👌🏻 🎉
Thanks Paul I appreciate ur feedback
Johno, I need your help, how do I size a low loss header, there is no information on it anywhere. My customer has a gigantic house, 33 radiators, he put a massive pump on it to drive it to all rooms because his boiler on its own was too wussy to over come the resistance, well ok, but the consequence is that there is not enough delta t across the flow and return so the boiler modulates at a lower than optimal temperature. I phoned Vaillant, they suggested a low loss header to create a neutral point and provide hydrolic separation, ok thats fine, but how to size the thing? No one knows, all engineers I know are dunces, no one on the internet can help, you are our only hope, your fan Roo.
What size kw boiler? Boiler flow and return temperature please?
boiler is Vaillant light commercial, 44 Kw , S-pan, unvented cylinder and rads, lots of rads. Design temp delta t is 20 Celsius. It has an internal pump and an external more powerful pump that the householder installed in an attempt to overcome the resistance to the heating circuit. Vaillant propose hydrolic seperation i.e a low loss header. Thanks so much for taking the time Johno.
What's ur flow and return temp
@@warriorsofwarmth 70-50
Tomorrow I'll make a video
Love these vids you do.
Thanks I really appreciate it
Thanks for the info. Nice close up shots there. Cheers
Thanks for the great feedback enjoy the rest of ur week
Tip on using a rad tail to fit a tap was outstanding
Johno, how do I size a low loss header. My customer has a light commercial Valiant boiler, 44 KW, it needs a low loss header as there is not enough differential temperature across the installation to make it ramp up to max temp. Any ideas, your fan Roo.
Great video. Thanks
Thanks for the feedback
Johno, where are the vids on heat pump installation, I am going to do the course and would like some solid direction.
When is your course? Are u doing Fgas or heat pump course?
Where are u based z?
The land of the free and the home of the brave, Glasgow, Scotland :D@@warriorsofwarmth
I could do both, but probably will do Heat pump course first. Will do it where i did my core gas and ACS, Clyde College, Glasgow.@@warriorsofwarmth
I have an apprentice, he's in his third year at Forth Valley College and he's always going on about emerging technology and telling me to do a heat pump installers course. I thought you might have some vids on whats involved. There are other ones on the internet but I canny trust them like i can trust you. If you have the time and inclination Johno, please make a heat pump installation vid, your fan Roo.
🤘😎🤘
Hope ur both well
The way I fit them.
Is the burner failure common on Intergas boilers? I know they have a slightly amended design as the burners now have a new part number.
The burner seal has been up graded
@@warriorsofwarmth Thx. I am aware of that from red to black in colour. But the burner now has a new part number. Are you saying there is no change with the burner, being the same old early failure job?