Guycho M Gruendler
เข้าร่วมเมื่อ 11 ก.ค. 2017
วีดีโอ
Fort Bluff Sewer/septic pool bathroom & cardinal staff house
มุมมอง 49ปีที่แล้ว
Fort Bluff Sewer/septic pool bathroom & cardinal staff house
Septic blockage and repair.
มุมมอง 143 ปีที่แล้ว
Septic back up into home troubleshooting and repair.
Deer Lick 371A septic
มุมมอง 163 ปีที่แล้ว
Sewer dain seems to no longer be connected to the septic tank.
Smoke test on plumbing drain system
มุมมอง 2694 ปีที่แล้ว
I did not find any leaks and after piping this one vent to the exterior the smell went away.
Overview: 2PSI natural gas piping overview
มุมมอง 11K4 ปีที่แล้ว
Overview: 2PSI natural gas piping overview
Mini-Split blower motor rebuild and replacement
มุมมอง 1564 ปีที่แล้ว
Mini-Split blower motor rebuild and replacement
Rheem Tankless water heaters troubleshooting
มุมมอง 28K4 ปีที่แล้ว
Rheem Tankless water heaters troubleshooting
Can you still regulate the flame on that? 2 tanks are getting heavy! lol
Change tips to change temp
H103? Error code?
What a mess.
Returns look awful small indeed for three ton.
The little barrier in the tank which affords the solids to drop and water to flow over is callwd a baffle or weir, yes?
The B tank is way to heavy to lug. I used the MC tank like you have. Not sure which turbo torch and tip I had but it was pretty much identical looking to yours.
Thanks bro...
I'd like to have a big threader, cutter, tripod, cutting dies and oil can.. but running copper tubing seems much more compatible ft or 2 lb systems since you don't really have to worry about pressure drops or leaks... as much..
Agreed…. Until you have a large BTU load.
i have a question if you can help me please , im istalling a new range and i don’t know if i have to install a regulator for the range or no ? i gonna have to apliances in the line one the furnarce and now the new range , the furnarce oh ready have a small regulator,,,,
Depends on your gas pressure…. If you don’t know call a pro. Sorry for the delay.
The sell an adapter to go to a b tank with that also
Where can I get that manual? When i turn my hot water on I get a flashing code of AO 61.
I use the X-4B with the A14 tip on everything to 1-1/8" and works great
I can't believe they can leave it like that I mean it's just sticking right out of this grass looks like an accident waiting to happen. I'm surprised the city approves of that I mean it seems like a lawn mower possibly rupture that or something running into it
It’s a steel riser it would take a pretty good size lawnmower to damage it…. If they are installed in an area where they are subject to damage such as in front of where someone might park a car then yes you have to put a steel or concrete column.
Really bad units stay away from Goodman, berought a new install second week when it got colder turned the heat on and unit keeps vibrating with a humming noise, installer says is 5he inducer motor and it will take about 2 months to get it...really disappointing...DO NOT BUY GOODMAN...bad customer service
Do you run your pressure test with the valves just turned off at The Regulators or do you plug off all your valves and then pressure test?
Sorry for the delayed response, I turn the service valves off and test with 10psi after that I drop the psi to 5psi and test low side with bubbles.
Benefits for a service repair plumber ? Compared to mapp and turbo torch??
thanks for posting this 800 number made a huge differece
gas leg is installed at the wrong location
You must (per code)install on before the regulator you could I guess also install one closer to the unit but that seems redundant to me.
I want to access the network via laptop. I have a bunch of garbage programs and entries I can't edit via the LXTB. Does anybody know exactly what I will need? Software, network cables etc.
So you got the turbotorch kit with the b tank connection and the adapter from b tank regulator to mc? Or did you just get the MC kit no adapter?
Hi, which type of tank is that please
Mc tank
Where did you get the tank.holder
Could you check error code 13 for Rheem tankless water heater. I have code 13 error and do not know how and what to proceed in terms of knowing what to fix. Thank you.
Did u ever find out what the code 13 was
Where in the hell can I get this manual?!?! I desperately would love one for the Rheem Rtex 27 kw tankless unit..
Call tech-support and request they send you a copy
@@guychomgruendler3430yes im having trouble on mine says h103 just instaled
Nice work!
Thanks
My helper just got one i just used it today so far i like it different than oxy acetylene gotta get used to that but its definitely nice being half the weight
Will this clear a code 29 ??
Call there tech support they are supper helpful 1 (800) 432-8373
Thank you so much for this information! I've have a college building with one of these old LX panels and there is no information that I've been able to find except yours. I would be interested in hiring you for a consultation by phone or email if you would be available. valentine.jim0@gmail.com Thanks again!
and good luck finding these switches. they did stop making them their are very few of these left at Hubble
Just a reminder, don’t buy proprietary products.
Thanks for the post. I just got the same one yesterday and started brazed up 7/8. Worked great! Your video was one of a few that confirmed my purchasing decision. I would love to see your rig after the storage you added.
WHAT?! I CANT HEAR YOU OVER THE TORCH! :)
Louis did a great job would absolutely use again, Saved a lot of money by ordering online compared to a local contractor
Nice job, new subscriber
Does it take a while to heat 7/8”
Plumbjitsu: I use it on 7/8” all the time works fine.
Used one for over 25 years, love it.