Micom P643 complete test through relay test kit
มุมมอง 1.1K11 หลายเดือนก่อน
# Micom P643 complete test step by step#
Micom P643 communication by S1Agile and IP changing through front port]]]
มุมมอง 819ปีที่แล้ว
P643 IP config from front port# micom IP config P643 communication
How to read fault record in siemens relay-7SA522
มุมมอง 621ปีที่แล้ว
How to read fault record in siemens relay-7SA522
How to check fault record in abb relay
มุมมอง 2.4Kปีที่แล้ว
How to check fault record in abb relay REL670 | abb relay fault record#REL670 How to See Fault Records in ABB REL -670 Relay. हिंदी में पूरी जानकारी | How to find fault details in ABB relay | Abb relay fault details| relay fault details in abb | fault records in ABB relay| ABB PROTECTION RELAY-REL670| ABB relay.abb-REL670| fault record in PCM600
How to check LBB/BFR relay setting param of REL670 relay(ABB make) and compare its setting| Hindi
มุมมอง 264ปีที่แล้ว
How to check LBB/BFR relay setting param of REL670 relay(ABB make) and compare its setting| . abb relay setting in hindi| abb relay configuration |abb relay| abb relay setting | abb relay ref615 |abb relay reset| abb relay fault current| abb relay communication|abb relay testing|abb relay trip test |abb relay training|abb relay rel 670| abb relay goose configuration|abb relay rel670
How to reset NIC link fail/Memory Allocfail/Battery alarm/Sntp fail alarm in micom relay| Hindi
มุมมอง 5Kปีที่แล้ว
How to check NIC link fail/Memory Allocfail, Battery alarm, SNTP fail alarm in Micom relay | How to check MICOM alarm (DISTANCE relays)|setting| event| disturbance| measurement| alarm| | How To See fault in Micom p442 Relay| how Micom p442 relay alarm check and reset| MicomP442 alarm| nic link fail alarm| battery alarm| sntp fail| alarm| memory alarm
Siemens Digsi software installation- Part-1
มุมมอง 319ปีที่แล้ว
Siemens Digsi software installation- Part-1
MICOM FAULT RECORD CHECK THROUGH S1 AGILE SOFTWARE
มุมมอง 401ปีที่แล้ว
HOW TO CHECK MICOM FAULT RECORD THROUGH S1 AGILE SOFTWARE WITHOUT GOING TO HMI
MICOM ONLINE MONITORING OF OPTO SIGNAL (DDB)
มุมมอง 317ปีที่แล้ว
HOW TO MONITOR ONLINE DDB OPTO INPUT OUTPUT SIGNALS IN MICOM RELAYS
PSL COMPARE IN MICOM RELAY
มุมมอง 217ปีที่แล้ว
HOW TO COMPARE PSL COMPARE IN MICOM RELAY BY USING SOFTWARE
How to set relay setting of Micom P643 differential relay in Hindi
มุมมอง 2.4Kปีที่แล้ว
How to set relay setting of Micom P643 differential relay in Hindi
How to Configure setting parameter of Micom P643 relay
มุมมอง 689ปีที่แล้ว
How to Configure setting parameter of Micom P643 relay
How to create a manual triggering of DR in REL670 ABB Relay
มุมมอง 318ปีที่แล้ว
How to create a manual triggering of DR in REL670 ABB Relay
How to trigger manual dr in Siemens Siprotec 7SA522 relay
มุมมอง 214ปีที่แล้ว
How to trigger manual dr in Siemens Siprotec 7SA522 relay
Micom P442 DR Extraction through S1 Agile and Analysis
มุมมอง 360ปีที่แล้ว
Micom P442 DR Extraction through S1 Agile and Analysis
How to Extract DR from REL670 relay| How to check ABB relay DR
มุมมอง 959ปีที่แล้ว
How to Extract DR from REL670 relay| How to check ABB relay DR
How to extract DR from Siemens 7SA522 relay
มุมมอง 452ปีที่แล้ว
How to extract DR from Siemens 7SA522 relay
Online configuration checking in REL670 ABB Reay
มุมมอง 96ปีที่แล้ว
Online configuration checking in REL670 ABB Reay
How to check all ABB relay communication through PCM600
มุมมอง 582ปีที่แล้ว
How to check all ABB relay communication through PCM600
TIME SYNCHRONISATION OF ABB REL670 RELAY
มุมมอง 942ปีที่แล้ว
TIME SYNCHRONISATION OF ABB REL670 RELAY
Sir COS ( carier out of sevice ) kese dekhe pls explain it
Nice sir...please keep sharing valuable information
Nice
If you have given a demonstration of Loop tests and findings it will be best .. Please try in another video
Nice
Sir, Some buttons on the relay are not working (OK and Book button). What is the solution of this problem? Could you help me?
U have to replace hmi display
Cfg file download kaise krte hai
Very useful
Sir, what is the meaning of X & Y coordinate?
Sir, What is full form of DDB ?
Sir, What is the purpose of the Battery in Relay ?
For internal clock
Awesome Video Thanks Sir
Sir in P243 relay "TCS not healthy" fault how to reset can you plz?.
What is TCS
@@powersystemhub2811 TCS - "Trip circuit Supervision" - TCS unhealthy fault led glowing - by normal reset procedures the fault /fault led not get reset.any other way to reset sir?
Bhuthi badhya sir ji thanks micom relay ht motor ka mesure ment me motor ka reading galat dikha raha hai kya fault ho sakta hai
Nahin. Reading ka value check karo
Software plz send me link
Thankyou so much sir upload this video.
Thank you so much sir upload this video.
Why sound is not clear...otherwise good informative video and appreciate your efforts
Bhai thoda voice & content me improvement ki jrurat hai
Voice will improve if U subscribe this channel
one doubt regarding dwell time. If the dwell time setting is 300ms and the input becomes zero in 100ms . output will stay on for 300ms or just 100ms
300ms
Sir DPR RELAY KA BHI VIDEO DALIYE NA
Dear frnds Pls subscriber the channel for latest update
How to find IP Address of C264 by using front panel?
U can find through CMT tools
And fault current how to she
U can see it in view record option
Fault indication kaisa thaykna
Sir, . 2 amp kaise aaya aapne previous video me bataya ki. 2 pu means for single phase about 780 ma to inject as per calculation but yaha to direct. 2 A inject kiya
Pick up current ke liye 2A dena hai
Video is good, please make one information complete and more elaborative so that a chapter could be understood for beginners.
You idiot, the 670 is from war criminal company Hitachi.
Sir can you plz share Modbus address registers for P243 & P253 model relay?. Thanks.
Hi sir
Sir how to update the firmware can you plz?
Sir this software can use for both P40 & P50 agile plz?
Display became blank & button not working then how to check
Switch off relay power supply and check whether it's working or not. If not then there may be HMI as well as hardware fail issue . Then relay will be sent for repair
@@powersystemhub2811 yes ...done power off ..same problem .. relay may be damaged .. relay need to be replaced . Pls quide ..I have spare relay of model . I have project file of this relay in back up .. how I transferred this settings to new relay .. pls give me the full process. As it is 400 kV line & also have scada programming
Excellent
Sir vt fail ka alarm kaisey reset karein
VT fail alarm Kab aata hai out karne pe ya service condition me.
@@powersystemhub2811sir in service time
So good... Well explanation... Keep it sir
Thanks and welcome
Hindi me bhi vedio laye
Sir about P632 Setting configuration video
Ok
@@powersystemhub2811 thanku sir
About P343 ?
Sir, kindly make a video of 132kv or 220kv auto reclosure setting and PSL logic in micom P444 or P442.
Please share your email id
Thank's
Really helpful information 👍
Kamal Video Well explained
Very good. Thanks 🙏
Nice Sir 765 kv substation GIS me Line reactor or Bus reactor per full details video And working principle per video bana sir ji plz
LBB relay use and working plz sir ji
LBB is used to clear the fault if circuit breaker fails to open . I will prepare one theory video regarding this
In numerical relay what is the meaning of trigger L/H and trigger H/L and no trigger ?
L/H means when voltage is high or ur any input is from 0 to 1 on relay then ur DR will trig. H/L is just opposite I.e. 1-0
Now voice clear 👍
Great sir, all my doubt got cleared
Very nice sir