Tempo Communications
Tempo Communications
  • 320
  • 773 082
Tempo FCL200 - HOW TO Replace the Cutting Disc
In this video we will replace the cutting disc on the Tempo FCL200.
The FCL200 is used for cutting and preparing fiber optic cables.
BUY The FCL200 HERE:
www.tempocom.com/products/fcl200-optical-fiber-cleaver/
__________
Facebook: pg/TempoComms/
Instagram: tempocomms
LinkedIn: www.linkedin.com/company/tempocomms/
__________
Further questions? Email or call us at our Vista, CA location. We'd love to hear from you:
Sales@tempocom.com
800-642-2155
มุมมอง: 49

วีดีโอ

Tempo 920CL - HOW TO Replace the Cutting Disc
มุมมอง 15วันที่ผ่านมา
In this video we will replace the cutting disc on the Tempo 920CL. The 920CL is used for cutting and preparing fiber optic cables. BUY The 920CL HERE: www.tempocom.com/products/920cl-optical-fiber-cleaver/ Facebook: pg/TempoComms/ Instagram: tempocomms LinkedIn: www.linkedin.com/company/tempocomms/ Further questions? Email or call us at our Vista, CA location. We'd l...
Tempo FCL200 - Reemplazo del disco de corte
มุมมอง 2121 วันที่ผ่านมา
En este vídeo sustituiremos el disco de corte en la Tempo FCL200. El FCL200 se utiliza para cortar y preparar cables de fibra óptica. Compre el FCL200 aquí. www.tempocom.com/products/fcl200-optical-fiber-cleaver/ Facebook: pg/TempoComms/ Instagram: tempocomms LinkedIn: www.linkedin.com/company/tempocomms/ Preguntas? Envíenos un correo electrónico o llámenos a nuestra...
Tempo 920CL - Reemplazo del disco de corte
มุมมอง 4421 วันที่ผ่านมา
En este vídeo sustituiremos el disco de corte en la Tempo 920CL. El 920CL se utiliza para cortar y preparar cables de fibra óptica. Compre el 920CL aquí. www.tempocom.com/products/920cl-optical-fiber-cleaver/ Facebook: pg/TempoComms/ Instagram: tempocomms LinkedIn: www.linkedin.com/company/tempocomms/ Further questions? Email or call us at our Vista, CA location. We'...
Tempo's Spike Marker Adapters | Secure Them to ANY Utility Line or Buried Wires!
มุมมอง 83หลายเดือนก่อน
Tempo's Spike Marker Adapters | Secure Them to ANY Utility Line or Buried Wires!
Test The WHOLE Fiber Optic Bundle, With This Bare Fiber Adapter!
มุมมอง 133หลายเดือนก่อน
Test The WHOLE Fiber Optic Bundle, With This Bare Fiber Adapter!
Get PERFECT Optical Power Meter Readings with THIS!
มุมมอง 2462 หลายเดือนก่อน
Get PERFECT Optical Power Meter Readings with THIS!
Fiber Testing Never Looked So Good!
มุมมอง 1956 หลายเดือนก่อน
Fiber Testing Never Looked So Good!
Tempo's PA4590 - Ethernet and Coax Technician Training Kit
มุมมอง 2536 หลายเดือนก่อน
Tempo's PA4590 - Ethernet and Coax Technician Training Kit
Troubleshooting 2-Wire Systems with a Milliamp Clamp Meter
มุมมอง 1.8K7 หลายเดือนก่อน
Troubleshooting 2-Wire Systems with a Milliamp Clamp Meter
Locating Irrigation System Wires, Valves and Faults - Webinar
มุมมอง 6568 หลายเดือนก่อน
Locating Irrigation System Wires, Valves and Faults - Webinar
Marcadores Spike de Tempo | Localice CUALQUIER línea enterrada décadas después
มุมมอง 308 หลายเดือนก่อน
Marcadores Spike de Tempo | Localice CUALQUIER línea enterrada décadas después
Troubleshooting Multiwire Irrigation Systems - Webinar
มุมมอง 2538 หลายเดือนก่อน
Troubleshooting Multiwire Irrigation Systems - Webinar
Instrucciones para encontrar cables, válvulas y fallas de riego con el 521E
มุมมอง 1.4K8 หลายเดือนก่อน
Instrucciones para encontrar cables, válvulas y fallas de riego con el 521E
Check Multi-Fiber Connectivity with Tempo's KingFisher XL Optical Power Meters
มุมมอง 1.1K8 หลายเดือนก่อน
Check Multi-Fiber Connectivity with Tempo's KingFisher XL Optical Power Meters
Introducing Tempo's Spike Markers! | Locate ANY Buried Line Decades Later, up to 3ft underground
มุมมอง 2319 หลายเดือนก่อน
Introducing Tempo's Spike Markers! | Locate ANY Buried Line Decades Later, up to 3ft underground
Loss Testing with the Tempo KingFisher 9000 series Pocket OPM and SLS
มุมมอง 2549 หลายเดือนก่อน
Loss Testing with the Tempo KingFisher 9000 series Pocket OPM and SLS
Duplex Loss, ORL and Length Testing with the Tempo KingFisher OLTS and Tempo Fiber Trainer | HOW-TO
มุมมอง 1509 หลายเดือนก่อน
Duplex Loss, ORL and Length Testing with the Tempo KingFisher OLTS and Tempo Fiber Trainer | HOW-TO
HOW TO Use The Tempo FIP100 Fiber Optic Cable Inspection Probe with the iOS and Android App
มุมมอง 1879 หลายเดือนก่อน
HOW TO Use The Tempo FIP100 Fiber Optic Cable Inspection Probe with the iOS and Android App
Loss Testing with the Tempo 2000 series Handheld Testers and Fiber Trainer | A HOW-TO
มุมมอง 1609 หลายเดือนก่อน
Loss Testing with the Tempo 2000 series Handheld Testers and Fiber Trainer | A HOW-TO
Bi-directional Loss, ORL and Length Testing with Tempo's KingFisher OLTS and Fiber Trainer | HOW TO
มุมมอง 2569 หลายเดือนก่อน
Bi-directional Loss, ORL and Length Testing with Tempo's KingFisher OLTS and Fiber Trainer | HOW TO
Tempo’s Fiber Trainer - THE tool to train fiber optic techs on installation, testing and maintenance
มุมมอง 53610 หลายเดือนก่อน
Tempo’s Fiber Trainer - THE tool to train fiber optic techs on installation, testing and maintenance
Less Common Tips for Tempo's FIP100 Fiber Inspection Probe | Long LC? MPO? We've got you covered!
มุมมอง 31010 หลายเดือนก่อน
Less Common Tips for Tempo's FIP100 Fiber Inspection Probe | Long LC? MPO? We've got you covered!
Checking PoE? (Power over Internet) - Learn MORE with this Online Seminar Recording
มุมมอง 14910 หลายเดือนก่อน
Checking PoE? (Power over Internet) - Learn MORE with this Online Seminar Recording
Introducing Tempo's PA1562 All-in-One UTP Pass-Through Crimper! Available Now
มุมมอง 36010 หลายเดือนก่อน
Introducing Tempo's PA1562 All-in-One UTP Pass-Through Crimper! Available Now
How To Use the Tempo Fiber Trainer to Exercise Fiber Optic Test Instruments
มุมมอง 37210 หลายเดือนก่อน
How To Use the Tempo Fiber Trainer to Exercise Fiber Optic Test Instruments
Being Connected in today's world and the future of Telecommunication Innovations
มุมมอง 8911 หลายเดือนก่อน
Being Connected in today's world and the future of Telecommunication Innovations
Tempo Communications | Enabling Connectivity for Today and Tomorrow
มุมมอง 10711 หลายเดือนก่อน
Tempo Communications | Enabling Connectivity for Today and Tomorrow
CÓMO REALIZAR un empalme por fusión con su FSP200 y FCL200 de Tempo Communications
มุมมอง 5211 หลายเดือนก่อน
CÓMO REALIZAR un empalme por fusión con su FSP200 y FCL200 de Tempo Communications
CÓMO UTILIZAR la sonda de inspección de fibra Tempo FIP100 con la aplicación para iOS y Android
มุมมอง 7911 หลายเดือนก่อน
CÓMO UTILIZAR la sonda de inspección de fibra Tempo FIP100 con la aplicación para iOS y Android

ความคิดเห็น

  • @rudy2981
    @rudy2981 5 วันที่ผ่านมา

    When i turn on my screen doeschange from the tempo logo i only had it for 8 months what can it be?

  • @GordieGii
    @GordieGii 5 วันที่ผ่านมา

    Sharp bends can cause scattering even if the fiber doesn't break.

  • @DiscountLowVoltage
    @DiscountLowVoltage 6 วันที่ผ่านมา

    Cutting disc? Oh, the cleaving disc 😜

  • @ahmednabiel10
    @ahmednabiel10 11 วันที่ผ่านมา

    1:01:12 Excellent webinar

  • @plang42
    @plang42 14 วันที่ผ่านมา

    Out ceiling fans are DC. They are quieter and use less power than AC fans.

  • @stevepearson6316
    @stevepearson6316 14 วันที่ผ่านมา

    I do not belive the power lines will go to DC ....most electric devices in your home is DC ...theres a AC DC transformer in those devises

  • @2zer084
    @2zer084 14 วันที่ผ่านมา

    You know for the past 50+ years, electronics have used ac/dc converters at the end of the plug right?

  • @caz937
    @caz937 17 วันที่ผ่านมา

    I'm in Wyoming and the fusion splicing is starting to get more difficult on our colder days. Is this method more reliable in colder environments?

  • @GremlinSciences
    @GremlinSciences 26 วันที่ผ่านมา

    The thing is, the standard doesn't actually matter, all that matters is that the wires in in the same order at both ends. The standards are just a way to stay consistent, they get taught and included with reference materials, and you can have separate people do either end of the line without issue as long as they're both following the same standard, but you don't lose any connection speed just because you aren't using the standard arrangement.

  • @ghostyxo2839
    @ghostyxo2839 28 วันที่ผ่านมา

    How to download or Active the Trace View to View files?

  • @alexanderc.346
    @alexanderc.346 28 วันที่ผ่านมา

    You can clean with a regular piece of paper if you don't have anything else on hand.

  • @einlehrling
    @einlehrling หลายเดือนก่อน

    We just dump it into isopropanol

    • @MaikTiison
      @MaikTiison หลายเดือนก่อน

      You mean that Aphex Twin track?

    • @einlehrling
      @einlehrling หลายเดือนก่อน

      @MaikTiison no I just take a little bottle of isopropyl alcohol and put the fibre glass connector in there No need for an expensive cleaning tool

  • @KnightspaceORG
    @KnightspaceORG หลายเดือนก่อน

    Man, of course this is an ad for something nobody will buy. Especially not when the box of swabs costs 65$. TH-cam advertising is terrible.

  • @jonathanpalmer228
    @jonathanpalmer228 หลายเดือนก่อน

    I work on haul trucks that see dust constantly and in the book according to wabtext a cotton swap or air is plenty

    • @TempoCommunications
      @TempoCommunications 29 วันที่ผ่านมา

      cotton swaps can leave lint, and compressed air can leave propellant residue. BUT we hope you don't have any problems.

  • @seagie382
    @seagie382 หลายเดือนก่อน

    80% of all reported network outages in fiber is because of me unplugging it to clean it because someone saw 3 crc errors in a week

  • @Thomas-tr6ok
    @Thomas-tr6ok หลายเดือนก่อน

    How much do they cost?

    • @jasperboer9854
      @jasperboer9854 หลายเดือนก่อน

      Everything fibre optic is super duper expensive

  • @christopherberberena5991
    @christopherberberena5991 หลายเดือนก่อน

    Hey it’s Fez. 😂

  • @misa80209
    @misa80209 หลายเดือนก่อน

    stop vocal fry

  • @alanjackson1015
    @alanjackson1015 หลายเดือนก่อน

    Sorry, this is useless. It is no more helpful than the owners manual

    • @TempoCommunications
      @TempoCommunications 25 วันที่ผ่านมา

      Is there something we can help you find? A Question you need to have answered?

  • @zackk695
    @zackk695 หลายเดือนก่อน

    How do I cut off the extra after I crimp? It leaves a small amount hanging out. I do this so I make sure I’m getting a good connection. The tool itself does not cut the wires clean like some of the others do leaving a tiny amount of wire hanging out and I don’t want them to touch because it can cause a short

  • @tydollasign9
    @tydollasign9 หลายเดือนก่อน

    I’ve used multiple VFLs and the Tempo unfortunately is the worst I’ve ever used. SC connectors have to placed on a certain way for red light to pass properly. Sometimes having to pull the SC connector half way off to get the optimal red light to pass properly. I do like your guys OTDR though. Red light on that is perfect.

  • @tonymaile7330
    @tonymaile7330 หลายเดือนก่อน

    I use T568A in the UK as I can remember it easily there is not much difference between the two if you wired one end as T568A and the other as T568B it makes a crossover cable that is used in situations to connect 2 computers together without a switch for example 2 tills so that can use the same printer

    • @davesradiorepairs6344
      @davesradiorepairs6344 หลายเดือนก่อน

      Correct for crossover cables In fact, it doesn't matter which standard you use, so long as both ends of the cables match...

  • @ianian14ify
    @ianian14ify หลายเดือนก่อน

    Canada uses 568A I think

    • @nchurly
      @nchurly หลายเดือนก่อน

      Not me in my home haha

  • @time4tea40
    @time4tea40 หลายเดือนก่อน

    I Just call them ‘British and American’ 😂

  • @2zer084
    @2zer084 หลายเดือนก่อน

    That’s not how you hold snips

  • @frackert
    @frackert หลายเดือนก่อน

    I never knew that AT&T standardized B. I've seen A a few times in the wild.

  • @ugh635
    @ugh635 หลายเดือนก่อน

    I'm 25 years of running Ethernet cable in all kinds of offices, INCLUDING government buildings, I've never done 568A.

  • @Henry_Jones
    @Henry_Jones หลายเดือนก่อน

    For tools i want swapable batteries.

  • @praga2734
    @praga2734 หลายเดือนก่อน

    if you need a wire in the conduit with a transmitter connected, how’s it going to stop you hitting a gas line?

  • @bramirez1803
    @bramirez1803 หลายเดือนก่อน

    What if you can’t find the valve box?

    • @TempoCommunications
      @TempoCommunications หลายเดือนก่อน

      Thanks for the question, ideally you’d have the 521E Wire and Valve Locator to track it down, but you can use the 24Bs ‘Chatter Mode’ in a pinch. Chatter Mode turns the solenoid on and off rapidly for you to try to locate the valve by ear.

  • @landerselectric
    @landerselectric หลายเดือนก่อน

    Absolutely love the Tempo 501! Gotta have it in the tool arsenal!

  • @97Boston
    @97Boston หลายเดือนก่อน

    Doi

  • @IronbirdAIT
    @IronbirdAIT หลายเดือนก่อน

    Heretic!

  • @bazooka712
    @bazooka712 หลายเดือนก่อน

    Jesus christ, you could have rappelled down Rapunzel's tower with that much stripped wire 😂

  • @msx0406
    @msx0406 หลายเดือนก่อน

    why A tho, Standard is B

    • @Manie230
      @Manie230 หลายเดือนก่อน

      No there is a reason why both exist cause there is no real standard.

  • @Ollav2k
    @Ollav2k หลายเดือนก่อน

    why so much waste?

    • @Kuffen_infinity
      @Kuffen_infinity หลายเดือนก่อน

      Was thinking the same, id have stoped before getting more out.

  • @jorgecalero6325
    @jorgecalero6325 หลายเดือนก่อน

    Jeepers, so much waste

  • @F4T4LSHTz
    @F4T4LSHTz หลายเดือนก่อน

    Type A? I have actually never cabled A style

    • @Manie230
      @Manie230 หลายเดือนก่อน

      Always A.

  • @roswel7845
    @roswel7845 หลายเดือนก่อน

    I usually measure how much to strip by the length of the jack

  • @TimThavirat
    @TimThavirat 2 หลายเดือนก่อน

    easy peasy!!

  • @ivanservin7678
    @ivanservin7678 2 หลายเดือนก่อน

    For the locator, it’s just a regular valve locator correct?

    • @AlejandroAste-Nieto
      @AlejandroAste-Nieto หลายเดือนก่อน

      The part at 12:26? Yep! But as long as you connect correctly, you should get good results from other types of locators and more importantly, avoid damage to devices. Reach out to Tempo Tech Support if you want to know more!

  • @wyliefitzgerald5964
    @wyliefitzgerald5964 2 หลายเดือนก่อน

    Hell yea these are the kinds of adds I’m okay eith

  • @JasonsLabVideos
    @JasonsLabVideos 2 หลายเดือนก่อน

    NICE !!! Good work guys !

  • @user-sd8qv8kp7e
    @user-sd8qv8kp7e 2 หลายเดือนก่อน

    Ya, don’t use this, buy a proper measuring tool. This will leak lights from one end to the other, be bending and breaking and reversing the cable back.

    • @2zer084
      @2zer084 2 หลายเดือนก่อน

      ? A vfl is a very commonly used and proper tool? An otdr serves in half the battle of locating a fault and if you don’t understand that you need to stay far away from fiber.

  • @TimThavirat
    @TimThavirat 2 หลายเดือนก่อน

    wait...it's an acronym?!!

  • @Nuggiesoftruth
    @Nuggiesoftruth 2 หลายเดือนก่อน

    Are these all daisy chained or can they burnout with a fuse

  • @Kirainian_Gaming
    @Kirainian_Gaming 2 หลายเดือนก่อน

    Gonna go fix the wire in my basement. Wish me luck!

  • @nicm5616
    @nicm5616 2 หลายเดือนก่อน

    An ad for something i probably won't need but it was so hilarious and played it it earned my sub.

    • @TempoCommunications
      @TempoCommunications 2 หลายเดือนก่อน

      Rad! If you liked this, check out our other product launch videos 🫶🏽

  • @Wuhdahfuk
    @Wuhdahfuk 2 หลายเดือนก่อน

    Made it look so easy that I paid someone else to do it