WM Bioprocess Tutorials
WM Bioprocess Tutorials
  • 29
  • 40 631
Krohne Flow Meter Demo at Two Flow Rates with Watson Marlow 530 Pump
A short demo of the Krone flow meter at two flow rates in the Watson Marlow 530En pump. Test is running tap water at room temperature in 1/4" ID tubing and 1/4" Krohne flow cell. Accuracy is excellent.
มุมมอง: 9

วีดีโอ

Watson Marlow 300 Series Pump Head Adjustment
มุมมอง 814 หลายเดือนก่อน
How to adjust your Watson Marlow 300 series pumphead for different inner diameter tubing. This works for 313, 314 and related pumpheads. The adjustment can be done on or off the pump. You have to make the adjustment with the pumphead fully open so you can align the marks in the video. Here's a close up photo of the adjustment. photos.app.goo.gl/czgkH3RPiYf3T2vS8
Flexicon Multi Capper FC10 Screw Capper
มุมมอง 536 หลายเดือนก่อน
The Flexicon FC10 is an easy way to screw cap vials that can't stand up on their own. Normally you would raise these up with a pocket or puck to allow capping. The multi capper is an easier way to cap lots of vials that tip over easily.
520Di Pump Head Options
มุมมอง 193ปีที่แล้ว
The Watson Marlow 520Di pump has multiple pump head options. Three options are shown. Full instructions and specs are in the online manual at www.wmfts.com
Watson Marlow 505L Pump Head Track Adjustment
มุมมอง 409ปีที่แล้ว
Here is how to adjust the Watson Marlow 505L pumphead back to factory specification. The factory specifies 2.4mm wall thickness tubing in this pumphead. Operators will sometimes change the screws not realizing that causes the pumphead to be out of adjustment. This is a quick method to get the track or lid on the pumphead back to factory spec. You'll need a flat head screwdriver and an electroni...
Watson Marlow 620 / 630 Pump Head Troubleshooting
มุมมอง 3.3K3 ปีที่แล้ว
This video answers two common questions with Watson Marlow 600 series pumps with the 620R, 620RE and 620RE4 pumpheads. If the pump doesn't seem to be pumping correctly, this short video may help you get pumping.
FF20 with Square 125 ml Bottles
มุมมอง 2783 ปีที่แล้ว
The Flexicon FF20 (and now FF15) can easily work with square bottles up to 125 ml volume. Standard adjustments in the feeding allow these bottles to feed as easily as round bottles.
Watson Marlow 730 Pump Memo Dose Feature
มุมมอง 1.3K3 ปีที่แล้ว
Watson Marlow 730 Pump Memo Dose Feature
How to connect using standard CPC Quick Connects
มุมมอง 4513 ปีที่แล้ว
How to connect using standard CPC Quick Connects
Sartorius Maxxis Controller Programming video #1
มุมมอง 3405 ปีที่แล้ว
Sartorius Maxxis Controller Programming video #1
Sartorius Maxxis Controller Programming video #2
มุมมอง 1055 ปีที่แล้ว
Sartorius Maxxis Controller Programming video #2
Sartorius Maxxis Controller Programming video #3
มุมมอง 875 ปีที่แล้ว
Sartorius Maxxis Controller Programming video #3
Watson Marlow Flexicon DF32 Chocolate Dispensing
มุมมอง 2057 ปีที่แล้ว
Watson Marlow Flexicon DF32 Chocolate Dispensing
Effect of Pump Speed (RPM) and Tubing Size on Fill Speed and Accuracy
มุมมอง 8887 ปีที่แล้ว
Effect of Pump Speed (RPM) and Tubing Size on Fill Speed and Accuracy
Watson Marlow 323Dz Filling Pump Operation
มุมมอง 2.5K7 ปีที่แล้ว
Watson Marlow 323Dz Filling Pump Operation
Watson Marlow 323 Peristaltic Pump Operation
มุมมอง 12K7 ปีที่แล้ว
Watson Marlow 323 Peristaltic Pump Operation
Watson Marlow 704 / 720 / 730 Pump Tubing Selection, Loading & Use
มุมมอง 10K8 ปีที่แล้ว
Watson Marlow 704 / 720 / 730 Pump Tubing Selection, Loading & Use
Watson Marlow 323 Pump with MC head
มุมมอง 7388 ปีที่แล้ว
Watson Marlow 323 Pump with MC head
Watson Marlow Flexicon UP20
มุมมอง 3658 ปีที่แล้ว
Watson Marlow Flexicon UP20
FF20 with MC12 and PD 12 for headspace gas control
มุมมอง 1.6K8 ปีที่แล้ว
FF20 with MC12 and PD 12 for headspace gas control

ความคิดเห็น

  • @jilllovepupply
    @jilllovepupply 3 หลายเดือนก่อน

    Sir. Thank you so much for this video. We have a 620S pump with 620 RE pumpheads for tube elements. Do you know if it’s correct to use the 620RTC Continuous Tubing Clamp 069.4101.000? This is the only tube clamp I can find online. Thank you so much.

    • @westernbioprocess
      @westernbioprocess 3 หลายเดือนก่อน

      The 620RE pumpheads are made for the tubing elements as you mention. You don't use continuous tubing or tubing clamps. If you try to put a continuous tubing clamp in the RE pump head, the pump door won't close. The reason is the gap in that pumphead is set for 4.0mm wall thickness which matches the wall thickness of the Loadsure tubing elements. The continuous tubing rotor is set for 3.2mm wall thickness tubing. The wall thicknesses are not interchangeable.

    • @jilllovepupply
      @jilllovepupply 3 หลายเดือนก่อน

      @@westernbioprocess thank you for the clarification!

  • @sherinjohn001
    @sherinjohn001 6 หลายเดือนก่อน

    I read it as Manual "something else" 🤷❤️

  • @iyokowa
    @iyokowa ปีที่แล้ว

    Hello, please how do you remove the clamps? I want to switch the clamps to different tube size but it’s stuck and won’t come off. Thanks

    • @westernbioprocess
      @westernbioprocess ปีที่แล้ว

      When the clamps are stuck, I've used flat head screwdrivers to pry them out. I start with smaller eyeglass type screwdrivers to minimize damage to the clamps. Often dried product residue is the culprit for sticking. Warm water can sometimes help. A light tap with a rubber mallet can also work.

    • @iyokowa
      @iyokowa ปีที่แล้ว

      Thank you. I’ll try that.

  • @sutrismuti4560
    @sutrismuti4560 ปีที่แล้ว

    How to open dosing license number 🙏🙏

  • @Yuusuke020393
    @Yuusuke020393 2 ปีที่แล้ว

    Hi John, I have a question. The pump has an internal calibration setting. Part of this setting, is the "Tube" parameter. Is the input for this parameter should be the inner diameter of the tubing / pipe used?

    • @westernbioprocess
      @westernbioprocess ปีที่แล้ว

      Yes, the tubing ID in mm should be used in the calibration menu. Check the black plastic tubing clamps also to make sure the ID stamped on the clamps matches the tubing ID.

  • @lifesjourneyyesr5079
    @lifesjourneyyesr5079 2 ปีที่แล้ว

    I sincerely appreciate this video brotha! We run the 620Du pumps. I work hard giving my 100% focus and effort and I really do strive to get our plants process dialed in; so it really means a lot that their are people like you to provide that visual based in the field education. If you ever have any questions feel free to reach out at anytime.

  • @gr8gau
    @gr8gau 3 ปีที่แล้ว

    Thank for the video. I want pump 100 ml/min, but cannot calculate the rpm to be set. I used the flowing formulae desird flowrate / (max flow rate/max rpm), my inner wall thickness is 1.6 mm. Could also please zoom / share pic where to adjust pump head for 1.6 mm ID, ext thickness 3.2

  • @jerseperussidebarros8372
    @jerseperussidebarros8372 3 ปีที่แล้ว

    how do I calibrate the pump flow beyond the rpm? I need a very low flow, would it just be with the hose change? thanks

    • @westernbioprocess
      @westernbioprocess 3 ปีที่แล้ว

      The pump in this video is the 323U pump. Its not designed to be a dispensing pump, but does have a simple dosing feature built in called "Memo Dose". An introduction to Memo Dose is in this video: th-cam.com/video/6EIS5OCIZxk/w-d-xo.html Check the 323 pump manual on the Watson Marlow website for more details on how to calibrate Memo Dose.

  • @hotmiramichi
    @hotmiramichi 4 ปีที่แล้ว

    great video

  • @hithereitsme8925
    @hithereitsme8925 5 ปีที่แล้ว

    Hi I have a problem with our pump I cant change the rpm rate for some reason theres a exglamation sign on screen ? If you have any ideas would be appreciated thanks

    • @westernbioprocess
      @westernbioprocess 5 ปีที่แล้ว

      If the padlock is also showing, you've activated the keypad lock. To unlock the keypad while the pump is running hold down the START key for 2 seconds. The padlock symbol will disappear. If the pump is stopped hold down the STOP key until the padlock symbol goes away. The exclamation point is the auto-restart feature. To remove auto-restart switch off the power at the rear of the pump. Hold down the STOP key and turn the power switch on. The ! symbol will go out.

    • @hithereitsme8925
      @hithereitsme8925 5 ปีที่แล้ว

      Ok thanks for heads up il try that when I get to work tomorrow thanks again

  • @martinneumann8073
    @martinneumann8073 5 ปีที่แล้ว

    How do you turn the little knob to adjust wall thickness? Mine is stuck and this is not on the manual somehow??

    • @westernbioprocess
      @westernbioprocess 5 ปีที่แล้ว

      You can't turn the knob to adjust for wall thickness. You either need the 4.8mm knob or 3.2mm knob depending on your tubing wall thickness. If you have the stock 4.8mm knobs and want to use 3.2mm wall tubing such as 1/2 x 3/4 or similar, you would need to order the 3.2mm knobs from Watson Marlow.

  • @salamali154
    @salamali154 5 ปีที่แล้ว

    Thanks

  • @ZacharyJohn22
    @ZacharyJohn22 8 ปีที่แล้ว

    golden globe