Customer had no Idea how Dangerous this was Major Gas Leak in Attic goes unnoticed for Years
Thanks for watching!
Feel free to use the affiliate links below if you’d like to help support the channel. I make a very small commission if you purchase through the links - Thanks!
TOOLS I USE
Klein Tools 3-in-1 Impact Flip Socket - amzn.to/35xOLdH
Fieldpiece SC680 - Wireless Power Clamp Meter - amzn.to/3FsPIjP
Testo 770-3 Digital MultiMeter - amzn.to/3qxVA6V
Fieldpiece JL3KM2 Job Link Dual Manometer Kit - amzn.to/3FAmf7A
Testo Bluetooth Smart Probe Kit - amzn.to/3Kh7cmU
Fieldpiece JL3KH6 HVACR Charge and Air Kit - amzn.to/3ruRVGy
Testo 405i Hot-wire Anemometer I Wireless Smart Probe - amzn.to/3Gv7e8e
Propane and Gas Leak Detector/Sniffer - amzn.to/3nn3HRY
Testo 416 Digital Mini Vane Anemometer - amzn.to/3A2tEvg
Fieldpiece STA2 Anemometer - amzn.to/3GBtQUL
Fieldpiece AAV3 Anemometer Velocity and Temperature Accessory Head - amzn.to/3qvA179
Seek Thermal CompactPRO Thermal Imaging Camera - amzn.to/3nvsMu4
CPS ABM-HOOD-200 Easy Air Flow Balancing Hood - amzn.to/3roiEV1
FLIR ONE Pro - iOS - Thermal Camera - amzn.to/3A4YPWz
มุมมอง: 240

วีดีโอ

Failed Attempt at Zone Damper Install HVAC Duct Work Attic Hack Job HVAC Day in the life
มุมมอง 41921 ชั่วโมงที่ผ่านมา
Thanks for watching! Feel free to use the affiliate links below if you’d like to help support the channel. I make a very small commission if you purchase through the links - Thanks! TOOLS I USE Klein Tools 3-in-1 Impact Flip Socket - amzn.to/35xOLdH Fieldpiece SC680 - Wireless Power Clamp Meter - amzn.to/3FsPIjP Testo 770-3 Digital MultiMeter - amzn.to/3qxVA6V Fieldpiece JL3KM2 Job Link Dual Ma...
Deadly Carbon Monoxide Levels caused by Misaligned Burner Assembly Over 1000ppm HVAC Training Videos
มุมมอง 68914 วันที่ผ่านมา
Thanks for watching! Feel free to use the affiliate links below if you’d like to help support the channel. I make a very small commission if you purchase through the links - Thanks! TOOLS I USE Klein Tools 3-in-1 Impact Flip Socket - amzn.to/35xOLdH Fieldpiece SC680 - Wireless Power Clamp Meter - amzn.to/3FsPIjP Testo 770-3 Digital MultiMeter - amzn.to/3qxVA6V Fieldpiece JL3KM2 Job Link Dual Ma...
Hot Surface Ignitor and Control Board Replacement on 90% Gas Furnace HVAC Tech Service Calls
มุมมอง 38214 วันที่ผ่านมา
Thanks for watching! Feel free to use the affiliate links below if you’d like to help support the channel. I make a very small commission if you purchase through the links - Thanks! TOOLS I USE Klein Tools 3-in-1 Impact Flip Socket - amzn.to/35xOLdH Fieldpiece SC680 - Wireless Power Clamp Meter - amzn.to/3FsPIjP Testo 770-3 Digital MultiMeter - amzn.to/3qxVA6V Fieldpiece JL3KM2 Job Link Dual Ma...
Inspect Furnace w/ KAIWEETS KBA01 Two-Way Articulating Borescope #havc #borescope #inspectioncamera
มุมมอง 13828 วันที่ผ่านมา
15% off code: JAG56EZ3 (Combines with the coupon displayed on product page.) Date of expiry: 11-30-2024 Buy from Amazon: www.amazon.com/dp/B0D9M3Q7FK 15% off code: HTK15 (Available sitewide at Kaiweets.com and it never expires.) Buy from official webstore: kaiweets.com/products/kba01-two-way-articulating-borescope?sca_ref=5465332.UihvFeHq1G More offerings from Kaiweets: kaiweets.com/collections...
Hard to Find Low Voltage Short On Roof op Package Unit
มุมมอง 353หลายเดือนก่อน
Thanks for watching! Feel free to use the affiliate links below if you’d like to help support the channel. I make a very small commission if you purchase through the links - Thanks! TOOLS I USE Klein Tools 3-in-1 Impact Flip Socket - amzn.to/35xOLdH Fieldpiece SC680 - Wireless Power Clamp Meter - amzn.to/3FsPIjP Testo 770-3 Digital MultiMeter - amzn.to/3qxVA6V Fieldpiece JL3KM2 Job Link Dual Ma...
How to Diagnose Bad Circuit Board on 80% Gas Furnace
มุมมอง 293หลายเดือนก่อน
Thanks for watching! Feel free to use the affiliate links below if you’d like to help support the channel. I make a very small commission if you purchase through the links - Thanks! TOOLS I USE Klein Tools 3-in-1 Impact Flip Socket - amzn.to/35xOLdH Fieldpiece SC680 - Wireless Power Clamp Meter - amzn.to/3FsPIjP Testo 770-3 Digital MultiMeter - amzn.to/3qxVA6V Fieldpiece JL3KM2 Job Link Dual Ma...
Air Handler Control Board Completely Fried HVAC Tech Bad Control Board Repair
มุมมอง 368หลายเดือนก่อน
Thanks for watching! Feel free to use the affiliate links below if you’d like to help support the channel. I make a very small commission if you purchase through the links - Thanks! TOOLS I USE Klein Tools 3-in-1 Impact Flip Socket - amzn.to/35xOLdH Fieldpiece SC680 - Wireless Power Clamp Meter - amzn.to/3FsPIjP Testo 770-3 Digital MultiMeter - amzn.to/3qxVA6V Fieldpiece JL3KM2 Job Link Dual Ma...
How on Diagnose a Bad Suction Line Temp Gas Sensor Failure on Trane TAM9 Variable Speed System
มุมมอง 2692 หลายเดือนก่อน
Thanks for watching! Feel free to use the affiliate links below if you’d like to help support the channel. I make a very small commission if you purchase through the links - Thanks! TOOLS I USE Klein Tools 3-in-1 Impact Flip Socket - amzn.to/35xOLdH Fieldpiece SC680 - Wireless Power Clamp Meter - amzn.to/3FsPIjP Testo 770-3 Digital MultiMeter - amzn.to/3qxVA6V Fieldpiece JL3KM2 Job Link Dual Ma...
How to find a HVAC Refrigerant Leak using a Ultrasonic and Electrolyte Leak Detector
มุมมอง 2462 หลายเดือนก่อน
Thanks for watching! Feel free to use the affiliate links below if you’d like to help support the channel. I make a very small commission if you purchase through the links - Thanks! TOOLS I USE Klein Tools 3-in-1 Impact Flip Socket - amzn.to/35xOLdH Fieldpiece SC680 - Wireless Power Clamp Meter - amzn.to/3FsPIjP Testo 770-3 Digital MultiMeter - amzn.to/3qxVA6V Fieldpiece JL3KM2 Job Link Dual Ma...
TESMEN Hound 200 EFM Meter Review
มุมมอง 2802 หลายเดือนก่อน
This is a quick review of the Tesmen hound 200 EMF meter. I have been using this meter for the last few months in the field and it has proven to be a pretty reliable and usable meter. Please let me know in the comments below if you have any experience with this meter and what you think!
90% Lennox Furnace Installed in Tight Crawlspace P Trap Solution for Condensate Trap install
มุมมอง 1702 หลายเดือนก่อน
Thanks for watching! Feel free to use the affiliate links below if you’d like to help support the channel. I make a very small commission if you purchase through the links - Thanks! TOOLS I USE Klein Tools 3-in-1 Impact Flip Socket - amzn.to/35xOLdH Fieldpiece SC680 - Wireless Power Clamp Meter - amzn.to/3FsPIjP Testo 770-3 Digital MultiMeter - amzn.to/3qxVA6V Fieldpiece JL3KM2 Job Link Dual Ma...
Using the CPS Easyflow Flow Hood Check Airflow on a Zone System HVAC Tech
มุมมอง 2193 หลายเดือนก่อน
Thanks for watching! Feel free to use the affiliate links below if you’d like to help support the channel. I make a very small commission if you purchase through the links - Thanks! TOOLS I USE Klein Tools 3-in-1 Impact Flip Socket - amzn.to/35xOLdH Fieldpiece SC680 - Wireless Power Clamp Meter - amzn.to/3FsPIjP Testo 770-3 Digital MultiMeter - amzn.to/3qxVA6V Fieldpiece JL3KM2 Job Link Dual Ma...
My Honest Opinion on VETO Pro Pac Backpacks HVAC Tool Bag Demo Pt2
มุมมอง 7623 หลายเดือนก่อน
My Honest Opinion on VETO Pro Pac Backpacks HVAC Tool Bag Demo Pt1 th-cam.com/video/qsevSYHd6OM/w-d-xo.html
Veto MB5B Vs Veto Tech PAC Which Bag is Better for Service? HVAC Tool Bag Demo 
มุมมอง 2.1K3 หลายเดือนก่อน
Veto MB5B Vs Veto Tech PAC Which Bag is Better for Service? HVAC Tool Bag Demo 
Contactor NOT Contacting Heat Exchanger NOT Exchanging Heat HVAC Day in the Life No Cool Diagnostic
มุมมอง 5923 หลายเดือนก่อน
Contactor NOT Contacting Heat Exchanger NOT Exchanging Heat HVAC Day in the Life No Cool Diagnostic
Improper Capacitor Install Can Be Costly Mistake HVAC Tech Kills Compressor on Routine Maintenance
มุมมอง 2.6K3 หลายเดือนก่อน
Improper Capacitor Install Can Be Costly Mistake HVAC Tech Kills Compressor on Routine Maintenance
It Seems Every Rheem Heat Pump Leaks on this Spot!! Troubleshooting and Repairing Leaking Unit
มุมมอง 9144 หลายเดือนก่อน
It Seems Every Rheem Heat Pump Leaks on this Spot!! Troubleshooting and Repairing Leaking Unit
How Much Does an Undersized Filter Affect Air Flower Testing with TEC True Flow Grid
มุมมอง 4724 หลายเดือนก่อน
How Much Does an Undersized Filter Affect Air Flower Testing with TEC True Flow Grid
Cleaning Dirty Evaporator Coil on Trane Air Handlers with Supco Portablaster HVAC training videos
มุมมอง 1.2K4 หลายเดือนก่อน
Cleaning Dirty Evaporator Coil on Trane Air Handlers with Supco Portablaster HVAC training videos
Customer Wrongly Accuses Me of Stealing! Said I Stole Money During Service Call What Would You Do?
มุมมอง 1.6K4 หลายเดือนก่อน
Customer Wrongly Accuses Me of Stealing! Said I Stole Money During Service Call What Would You Do?
Ohming Out Shorted a Contactor with Multimeter HVAC Training Videos
มุมมอง 3935 หลายเดือนก่อน
Ohming Out Shorted a Contactor with Multimeter HVAC Training Videos
Watch Before Buying HVAC Tools I Regret Buying vs Best HVAC Tool Purchases HVAC Tech Tool Review
มุมมอง 4.5K5 หลายเดือนก่อน
Watch Before Buying HVAC Tools I Regret Buying vs Best HVAC Tool Purchases HVAC Tech Tool Review
AC No Cooling Call Breaker Tripping Screw through High Voltage Wire on Disconnect Causes Short
มุมมอง 4525 หลายเดือนก่อน
AC No Cooling Call Breaker Tripping Screw through High Voltage Wire on Disconnect Causes Short
Failed Blower Wheel hub causes unit to Shake Violently and Blow the Fuse in Air Handler Diagnose
มุมมอง 2975 หลายเดือนก่อน
Failed Blower Wheel hub causes unit to Shake Violently and Blow the Fuse in Air Handler Diagnose
Preventive Maintenance Saves Compressor - Trane Unit Running Without Metering Device for Years
มุมมอง 1.2K6 หลายเดือนก่อน
Preventive Maintenance Saves Compressor - Trane Unit Running Without Metering Device for Years
Never Charge a System with Dirty Coils HVAC Tech Troubleshooting and Diagnostic
มุมมอง 9366 หลายเดือนก่อน
Never Charge a System with Dirty Coils HVAC Tech Troubleshooting and Diagnostic
Multiple Issues Found On No Cooling Call Overcharge, Filthy Filter, Low Capacitor and Clogged Drain
มุมมอง 8846 หลายเดือนก่อน
Multiple Issues Found On No Cooling Call Overcharge, Filthy Filter, Low Capacitor and Clogged Drain
Condenser, Evaporator Coil and Blower Wheel Cleaning gives this Old Package Unit a New Lease on Life
มุมมอง 5446 หลายเดือนก่อน
Condenser, Evaporator Coil and Blower Wheel Cleaning gives this Old Package Unit a New Lease on Life
Trane Air Handler Leaking Water in Attic Design Flaw HVAC Tech Training
มุมมอง 1.1K7 หลายเดือนก่อน
Trane Air Handler Leaking Water in Attic Design Flaw HVAC Tech Training

ความคิดเห็น

  • @flyer617
    @flyer617 2 ชั่วโมงที่ผ่านมา

    I bought a house where the previous owners were always sick and their kids had all kinds of problems. There was a massive gas leak in the basement from an antique stove burner. I'm shocked the place hadn't blown up. They said they had been smelling gas for over a decade and had all kinds of service people in for the ancient oil fired boiler and nobody had said anything. So what was obvious for you to track down didn't seem to bother countless service techs in this house. Yes I fixed it immediately.

  • @Juli079
    @Juli079 6 ชั่วโมงที่ผ่านมา

    .27 PSI?

  • @WatchmanNz
    @WatchmanNz 12 ชั่วโมงที่ผ่านมา

    This is why you need tell your installers to prepipe to left and have the flare joints under the unit! Not in the damn wall…

  • @russellham2094
    @russellham2094 วันที่ผ่านมา

    Great mod 👍

  • @deanmartin1966
    @deanmartin1966 วันที่ผ่านมา

    Damn. Good find. You probably saved their lives.

  • @cjjuszczak
    @cjjuszczak วันที่ผ่านมา

    N.B. it is also sold as the "HABOTEST HT205" and "MAYILON HT205". Version "HT205-A" is an "AC only clamp meter" and Version "HT205-D"is an "AC/DC clamp meter" There is also a nearly identical "HABOTEST HT203D", which moves the buttons to the bottom, but i'm not sure if there are any other specs different. GVDA has multiple versions, but they are absolutely incompetent at explaining the differences between models, literally they DO NOT explain at all, no functions, no specs, no table, NOTHING o.O

  • @MattBruner-fh3jg
    @MattBruner-fh3jg วันที่ผ่านมา

    Love that! Excellent work

  • @AstelloAlbany
    @AstelloAlbany 2 วันที่ผ่านมา

    Good job! At 27:56, you put the core in and then open the valve, but the micron gauge is already removed. Is that correct? I believe that when you remove the micron gauge, a significant amount of air enters the system. Even if that’s not the case when you remove the micron gauge, the pressure in the system is negative, allowing air to enter through the core. We always open open valve first, then put core in, and remove micron gage.

  • @ricardoa4322
    @ricardoa4322 3 วันที่ผ่านมา

    The yelow jackt probes are god

  • @ShanePinckney
    @ShanePinckney 4 วันที่ผ่านมา

    Can no water in trap lead to CO coming out of trap vent?

  • @jimenez3053
    @jimenez3053 5 วันที่ผ่านมา

    The hose is ur problem. Put a heavy fitting at the bottom so it can be steady.

  • @hakimsarif5191
    @hakimsarif5191 6 วันที่ผ่านมา

    I have a Mitshubishi 24k btu multi split. When i turned it on. Only the bottom part of the evaporator coil is cold and the top part takes ages to cool down. Could this be due to a restriction?

  • @elleondejuda4681
    @elleondejuda4681 6 วันที่ผ่านมา

    Is that a contactor ?

  • @andrewkime2325
    @andrewkime2325 7 วันที่ผ่านมา

    Not checking pressure switch checking inducer motor

  • @ziahejrat7594
    @ziahejrat7594 8 วันที่ผ่านมา

    Thanks buddy Great advice ❤❤❤

  • @michaelglasser6923
    @michaelglasser6923 8 วันที่ผ่านมา

    Nice video. Did you also address the strainer temp drop?

  • @hediervarelamedina987
    @hediervarelamedina987 8 วันที่ผ่านมา

    The video is good but you should fit a cyclonic cleaner to the vacuum cleaner so that the vacuum cleaner filter does not get dirty and so it always stays clean. For the rest, the video is good.

  • @robertcherry4971
    @robertcherry4971 9 วันที่ผ่านมา

    Always check airflow before charging… You should know your ABC’s.

  • @popsmccartney435
    @popsmccartney435 9 วันที่ผ่านมา

    What number tip do you use?

  • @youngjedi5599
    @youngjedi5599 9 วันที่ผ่านมา

    Every time the same spot on the outdoor unit.

  • @alfredode6142
    @alfredode6142 10 วันที่ผ่านมา

    It works perfectly, but after the warranty, you will have to throw it away. I liked it a lot, but a cheap Chinese one is the same and safer to use. It's a shame that Germans make junk nowadays.

  • @pauleastend4706
    @pauleastend4706 11 วันที่ผ่านมา

    Pipe dope is very important but it's not supposed to be applied on the first two threads of any nipple.

    • @HVACTechKnowledgy
      @HVACTechKnowledgy 11 วันที่ผ่านมา

      Thanks! Great tip I'm going to look more into that thanks for watching

  • @0413simba
    @0413simba 12 วันที่ผ่านมา

    How do you plug test port on B Vent.

    • @HVACTechKnowledgy
      @HVACTechKnowledgy 11 วันที่ผ่านมา

      Hey there! Great question I use high temp silicone

  • @ashot11223
    @ashot11223 14 วันที่ผ่านมา

    That camera angle hurt my neck lol

  • @SV-lw8jo
    @SV-lw8jo 14 วันที่ผ่านมา

    During a routine yearly maintenance, the technician told me that my HVAC had a leak, even though it had been working fine. He provided a quote of $11,617 after rebates to replace my HVAC. I decided to get a second opinion, and another technician said the issue was simply that the valves hadn’t been tightened properly. He quoted me over $1,500 just for the 8 pounds of refrigerant. I declined and went online, where I was able to buy 10 pounds of R410A refrigerant for just $256, including shipping. It’s frustrating dealing with these over-the-top charges, and it’s hard to trust anyone anymore. It feels like you’re always being taken advantage of.

  • @cellocovers3982
    @cellocovers3982 14 วันที่ผ่านมา

    Why does this result in incomplete combustion?

  • @cellocovers3982
    @cellocovers3982 14 วันที่ผ่านมา

    Isn't this video from a while ago? I remember you uploading this like a year ago.

    • @HVACTechKnowledgy
      @HVACTechKnowledgy 11 วันที่ผ่านมา

      Yes sir good catch! Sometimes I like to recirculate the videos I find most informative as most of the viewers that watch my channel are new to the channel . But I appreciate you for being a long time viewer

  • @Jackapoo1
    @Jackapoo1 15 วันที่ผ่านมา

    Outstanding ❤

  • @UncleEarlHeatingAirCondition
    @UncleEarlHeatingAirCondition 15 วันที่ผ่านมา

    Always nice content. Thank you! Even though you are looking for under 100 ppm "technicly," you should be striving to get as close to 0 ppm as possible. 0-50 would be more like it. 90ppm is just to close to 100. when you are at 90ppm, it wont take much to creep over 100ppm after you leave. I didn't see in your video if you clocked the gas meter input? Checking pressure is good but you can still have an over gas situation with good pressures. Also recheck the orfice sizes, i have found that some units are shipped from the factory with the wrong size orifices and never is cought until the input is checked. Set per code to derate no more then 2% under the rating plate input. I'm passing on additional information for you

  • @gilbertomejiajr1706
    @gilbertomejiajr1706 15 วันที่ผ่านมา

    I put my drill inside next to the bottom pockets and it fits nicely great bag mb5b

  • @alexmontoya7258
    @alexmontoya7258 16 วันที่ผ่านมา

    that was a good diagnostics

  • @Jay-tr3px
    @Jay-tr3px 17 วันที่ผ่านมา

    Hi thanks for the review. Is this the same product as the gvda gd166b model??

    • @cjjuszczak
      @cjjuszczak วันที่ผ่านมา

      Version "HT205-A" is an "AC only clamp meter" and Version "HT205-D"is an "AC/DC clamp meter"

  • @MRGLOCK64
    @MRGLOCK64 17 วันที่ผ่านมา

    Interesting

  • @liquidsunshine697
    @liquidsunshine697 17 วันที่ผ่านมา

    Do HVAC positions test for THC? Hopefully this question isn't offensive. Curious to know what trade I can go into and still recreationally use. People can drink in all trades so I'm hoping the stigma with THC is softened.

  • @gerardotello7101
    @gerardotello7101 17 วันที่ผ่านมา

    I'm am 6 months into HVAC school, this is very helpful information. Thank you.

  • @ernestogalindo3149
    @ernestogalindo3149 19 วันที่ผ่านมา

    I really like fieldiece because all the features it has but those fluctuations on the voltage and ohms when u turn them on sucks ive had 3 meters and all of them do the same after a while. Fluke meter its been great for me.

  • @mark.r8900
    @mark.r8900 19 วันที่ผ่านมา

    Very nice. Hi, my york YP9C inducer motor has only two wires. How is it able to ramp up and down with only two wires connected. One wire is HOT and the other is NEUTRAL. Thanks.

  • @ZoeSwagCrew
    @ZoeSwagCrew 20 วันที่ผ่านมา

    What mixture do you use to spray 1st and what coil cleaner was use ?

  • @brian_onthewater
    @brian_onthewater 22 วันที่ผ่านมา

    Found what looked like dirt dobbers the other day in a gaspack after i jumped the switch to test rest of the sequence. Was packed at port, and couple inches up the hose.

  • @picnicsinspace198
    @picnicsinspace198 22 วันที่ผ่านมา

    That's so good! thanks for this.

  • @lyotoarellano
    @lyotoarellano 22 วันที่ผ่านมา

    Such a good feeling when you're not 100% sure but you have a hunch and it turns out to be right. Such a relief and accomplishing feeling. One of the many reasons why I do it

  • @michaelglasser6923
    @michaelglasser6923 22 วันที่ผ่านมา

    Nice job. Was that a 1 to 1 setup, or was there a branch box?

  • @tarcisio125
    @tarcisio125 22 วันที่ผ่านมา

    Do you think this camera is better than the tc003 that you also tested on the channel?

  • @davidwilliams729
    @davidwilliams729 27 วันที่ผ่านมา

    Never used puncture probes before

  • @qj5299
    @qj5299 27 วันที่ผ่านมา

    I have a Goodman 80% furnace that ignites but goes right out. Changed flame sensor and pressure switch, but still doing the same thing. Any ideas, what it could be?

    • @KirbyJr
      @KirbyJr 6 วันที่ผ่านมา

      did you figure it out?

    • @antdog7z79
      @antdog7z79 2 วันที่ผ่านมา

      Would recommend checking a few more thangs as far as your aux limit switch and all your switch’s rollout etc check your water columns (W.C) look at the data plate what your unit calls for and your transducer if your unit has one

    • @antdog7z79
      @antdog7z79 2 วันที่ผ่านมา

      Also your blower if it’s running or not

    • @qj5299
      @qj5299 2 วันที่ผ่านมา

      @antdog7z79 I unplugged the control board and plugged it back it. Started running ok for awhile and then back off.

    • @antdog7z79
      @antdog7z79 2 วันที่ผ่านมา

      @@qj5299 yea check all your limits brotha and transducer if unit has it had the same issue with a Coleman pckg unit 5ton replaced board pressure switch all limits etc coming from tech support to the point where they said we need to swap it out

  • @alimuh007
    @alimuh007 28 วันที่ผ่านมา

    That's way too much attached to your hips unevenly. Young men don't realize or care about their bodies sometimes..... please consider reducing or distributing the weight a bit.

  • @IceWhiteice22
    @IceWhiteice22 29 วันที่ผ่านมา

    I just brought one, it seems to be a very valuable tool

  • @Hubratt1
    @Hubratt1 29 วันที่ผ่านมา

    Or buy a cheaper filter that is thinner. Replace it once a month. Doesn't cost much.

  • @Josh-px6xb
    @Josh-px6xb หลายเดือนก่อน

    Did you jump pins 12 and 15 to R on the PCB? And 1 and 3 to common? It looks like you did pins 1 and 3 to R. Wouldn’t that be shorting it out?

  • @tunaman2200
    @tunaman2200 หลายเดือนก่อน

    Great video bro! I appreciate the fact that you really tried to measure it correctly. Covering the gaps and stuff. Thank you for sharing this !

    • @HVACTechKnowledgy
      @HVACTechKnowledgy หลายเดือนก่อน

      No problem Glad it was helpful!

    • @tunaman2200
      @tunaman2200 หลายเดือนก่อน

      @@HVACTechKnowledgy you know this got me thinking on some registers that are not easily accessible ( like toe kicks) I can use the hot wire !