- 22
- 357 455
iACS
United Kingdom
เข้าร่วมเมื่อ 22 ม.ค. 2012
iACS were born in 2011 as i-A.C.Systems. Operating from a shoe box office in South East London and employing 1½ people - the space was small but the vision was huge!
Fast forward to 2019, iACS have made a name for themselves in the UK as Air Handling Control Experts - the software team work relentlessly in ensuring that the AHU control solution remains ahead of the curve while our in-house panel build team work to the highest standard in order to achieve quickest turnaround in the Industry.
As the only HVAC Controls Specialist in the UK specialized solely in AHU controls and backed with over 25 years experience, it’s no surprise that our client retention rate exceeds 95% - no one does AHU controls quite like us..
Our company is registered in England and Wales (Company no. 7049504).
Feel free to contact us on:
e. info@i-acs.co.uk
t. +44 (0) 20 81333679
Fast forward to 2019, iACS have made a name for themselves in the UK as Air Handling Control Experts - the software team work relentlessly in ensuring that the AHU control solution remains ahead of the curve while our in-house panel build team work to the highest standard in order to achieve quickest turnaround in the Industry.
As the only HVAC Controls Specialist in the UK specialized solely in AHU controls and backed with over 25 years experience, it’s no surprise that our client retention rate exceeds 95% - no one does AHU controls quite like us..
Our company is registered in England and Wales (Company no. 7049504).
Feel free to contact us on:
e. info@i-acs.co.uk
t. +44 (0) 20 81333679
How to Change The Target Setpoint
This video will walk you through the steps you need to take in order to change the target setpoint using the HMI.
มุมมอง: 1 499
วีดีโอ
How to Turn the Unit On/Off
มุมมอง 1.8K4 ปีที่แล้ว
This video will walk you through the steps you need to take in order to turn the unit on or off via the HMI.
How to Change Fan Speed when Configured to be Fixed Speed
มุมมอง 8614 ปีที่แล้ว
This video will walk you through the steps you need to take in order to change the fan speed when configured to be fixed speed via the HMI.
How to change Fan Speed when Configured to be Variable Speed via Pressure Control
มุมมอง 6024 ปีที่แล้ว
This video will walk you through the steps you need to take in order to change the Fan Speed when configured to be Variable Speed via Pressure Control via the HMI.
How to change Fan Speed when Configured to be Variable Speed via CO2 Control
มุมมอง 2754 ปีที่แล้ว
This video will walk you through the steps you need to take in order to change the Fan Speed when configured to be Variable Speed via CO2 Control via the HMI.
How to view and action Alarms
มุมมอง 1.1K4 ปีที่แล้ว
This video will walk you through the steps you need to take in order to view, acknowledge and reset alarms using the HMI.
How to View the complete list of Sensors, Statuses and Outputs
มุมมอง 7584 ปีที่แล้ว
This video will walk you through the steps you need to take in order to view the complete list of sensors, statuses and outputs using the HMI.
How to Enable the Scheduler
มุมมอง 6734 ปีที่แล้ว
This video will walk you through the steps you need to take in order to Enable the Scheduler using the HMI.
How to change the Modbus Address on the controller
มุมมอง 1.4K4 ปีที่แล้ว
This video will walk you through the steps you need to take in order to change the Modbus Address on the controller using the HMI.
How To Change the IP Address Of A pCOWeb Card
มุมมอง 10K5 ปีที่แล้ว
In this video, Stefano will walk you through the process of changing the IP Address on a CAREL pCOWeb Card via the PGD1 display. www.i-acs.co.uk
MasterAria Quotation Wizard - Quick Guide
มุมมอง 2379 ปีที่แล้ว
www.i-acs.co.uk/ This video provide a quick guide and tutorial on how to use the MasterAria Quotation wizard downloadable from our website. This wizard will provide an easy tool to price the controls for an AHU using Carel products. Follow us for more tutorials and support @iac_systems
MasterAria Large Electrical Panels for AHU
มุมมอง 1.2K9 ปีที่แล้ว
www.i-acs.co.uk Carel AHU electrical panel standard solution to control an AHU up to 15 Kw motors with contactors for Supply and Extract Fans, auxiliary contactor for heat wheel or any other heat recovery with 230V power supply. Fire alarm relay, remote display connection pre installed, modbus communication to Carel VFDs embedded. Visit the MasterAria home page on: www.i-acs.co.uk/store/index.p...
AHU Controls software FLSTDMmAHUE 1.3 - What's New
มุมมอง 16K9 ปีที่แล้ว
AHU Controls software FLSTDMmAHUE 1.3 - What's New
Adding more AHUs to the Tridium Template Dashboard
มุมมอง 17K9 ปีที่แล้ว
Adding more AHUs to the Tridium Template Dashboard
MODSCAN
มุมมอง 200K9 ปีที่แล้ว
www.i-acs.co.uk/ A quick tutorial on how to use MODSCAN used to scan MODBUS Networks. Follow us for more tutorials and support @iac_systems
How to Fix a "No Link" screen on a CAREL PGD1 Display Connected to a PCO Controller
มุมมอง 68K9 ปีที่แล้ว
www.i-acs.co.uk/ This video will guide you through the procedure to clear the NO-LINK message appearing typically on a Carel PGD1 displays when connected to a Carel PCO3, PCO2, PCO1 or even a PCOXS controller. This message is not referring to an alarm condition of the system but simply to a miss-communication between the PLC controller and the PGD Display. Follow us for more tutorials and suppo...
Overview of the MasterAria LIGHT AHU Panel
มุมมอง 4249 ปีที่แล้ว
www.i-acs.co.uk/ We are proud to present the new entry from the Masteraria Panels: The LIGHT Version features great versatility and a saving of 25% on the STANDARD version. Visit: www.i-acs.co.uk/store/index.php/air-handling-units-ahu/electrical-panels.html for more information. Follow us for more updates and support @iac_systems
2 PGD1s on 1 PCO controller on a pLAN Network
มุมมอง 6K9 ปีที่แล้ว
2 PGD1s on 1 PCO controller on a pLAN Network
Jace dashboard for the Carel AHU Controller
มุมมอง 9K9 ปีที่แล้ว
Jace dashboard for the Carel AHU Controller
AHUnCHILL SOFTWARE controlling an AHU with integrated with digital scroll compressor
มุมมอง 7K9 ปีที่แล้ว
AHUnCHILL SOFTWARE controlling an AHU with integrated with digital scroll compressor
For example, there is a device that can communicate with RS485. Can we rely on this tool to search for the address of the device without looking at the manual?
How to select slave id
Not clear video
Hi, I got a problem with pgd0 display, I change the adress to 00 and press "Alarm - Up " button , it can not acess to pCO3 controller to set the address of the PCO3, May pgd display got problem with the port or the firmware or the hardware? And How to reset the pgd. Thanks
hello sr need your help seme This model precision unit carel pGD controller no line coming how to update sr because there 2 unit one unit address how many setting boss help me
I need ur help
Holding register adress in which data format
Start with 4
Please how do I configured a new pic board
Thnxs more Nd more fr ur effort we need. How we concet EEv so this device
Can you please suggest what hardware requirements for modbus scan
th-cam.com/video/qPloBNTGmIM/w-d-xo.html&feature=share
What about 091 alarm expansion 1 no-link
can i ask about pgd controller alarm says (set exceeded temperature ambient air ) please help me
how can i get the software like this
Could you help me, I want to download the temperature set point but I need the access password
Hi Stephane, Can you please help me to solve this problem with pco0100 ,it display blank screen after setting it to 0. Thanks
Bonjour, comment peut on acier la fonction no pLan, en cas d'urgence
Please you can sand me 1PGD Display canecte to two pco3 Video
I can get to the very first screen from 32 to change to oo, but my controllers just DO NOT go to the self test screen afterwrds? is this normal? i have watched many videos and i dont know why 2 of the controllers i have do not do the self test, thanks in advance
Please you can tell me how to setup 1 pgd display canected two pco3 controler
Can you do a tutorial on how to used BACset
Good evening sir, I have forgotten my password, how to open pGD user interface controller, Please help me,
Can you help me I want the manufacturing password of Carel W3000. (For Climaveneta's chiller)
We installed new one pco5 controller everything working but user interface language showing Dutch how we change English language
Hi ! Thanks for this very informative video. I have a similar issue but NO LINK does not appears at power on but after a few days (actual delay is random). If I power the unit off then back on, the NO LINK error disappears, but still comes back after a few days and so on. Do you think the procedure described in this video is supposed to fix such an issue ?
Hi I had no link then set up address for both display and board all reading came back to display but on the bottom of display it was showing off by mask, any idea ..
I want to help
How do I do the new PCO5
I have a chiller that has 2 pco5 in it and would like to change one of them
Hello Does possible connect pgd to cpy humidity controller
If you reboot your PCOWEB remotelly, you will lose COMMs for the period of time in which the PCOWEB will restart. Once it has restarted, it will work off the new settings you would have saved (IP address, subnet mask, gateway etc.) The PCOWEB normally resets in about 3/5 minutes. There are no risks involved... If you accidentally save an reboot the PCOWEB with COMMS fields that you can't access anymore, you will need someone infront of the unit to REBOOT the PCOWEB with the Default settings in order to access the card locally and change your settings to new ones though.
Hi Stefano, I disabled my PCOWEB HTTP WEBServer. I can ping the correct IP and I got answers. Is there any possibilty to reset the pcoweb that I can access via Internet browser again?
Hi, If I access my PCOWeb via the browser by entering ts IP address. I can see Reboot button. If I want to reboot the PCOWeb remotely: What are the risks here? Will I lose any communication completely? How long does it take for PCOWeb to come back online after rebooting it?
I have a problem in carel w3000 xl no link adresse32?
Can you help me I want the manufacturing password of Carel W3000. (For Climaveneta's chiller)
@@bhupindersingh4645 99990 & 12345
What converter do you recommend?
Could you also prepare the same table for uPC controller?
it was given table between 11.15 and 12.25 about pCO 5 or pCO 3? I try to learn something about pCO5.
Hello i have also black screan!What to do?
Thanks sir. While pressing the buzzer and up button togher nothing is happing.kindly suggest ..
Hi Ravi, this sounds most likely to be a faulty PGD display.. you can find replacements here: www.i-acs.co.uk/store/index.php/pgd1000f00.html
I have the same problem, on 2 pCO3 with 3 different pGD terminals. Do you have any idea?
@@LtdJorge Hi, it does seem rather strange to have 3 different PGD terminals that are all faulty, all I can presume is that this is to do with a wiring issue on the pLAN. I would suggest checking the wiring connections to the controller.
@@iacs actually, we have them connected locally, so they are doing fine on address 0, but they are using that address now because they started throwing the no link error out of the blue, but they were all on address 32 for the pGD and 1 for the pCO, as they aren't in a pLAN. One thing I have noticed now, fiddling with it is that after a very long press of the UP and Alarm buttons while starting up, the "selftest message" appears but disappears almost instantly, displaying the typical status of the controller. I am starting to think that the developers of the firmware locked down the access.
Well, technically, one of the controllers displayed the no link error, and we tested 3 terminals on it, until discovering this video. Then I put the displays on address 0 and they work, but I cannot enter the address menu for the controller. I tested on another controller with one of the address 0 terminals and it worked, but the controller address menu couldn't be entered, as with the other one. This is what suggests me the lock down.
If the AHU's are the same, using a single px and relativize the ords would simplify the rpocess. There's no need to create a separate PX for each AHU if they are the same.
Hi, do you what kind of software is that? I wanna know to create my own graphics, tks y
How will you file Ord to the second AHU
Hi I have PCO3 a issue The Display working but no letters .after power up loading 2 Sec then nothing in display so pls support me . How to solve ?
Hi, I've followed the procedure all the way and after i set the display to 32, the no link symbol appears and then the screen goes blank. Where/how do i download ahu software for the device?
Hi Martin Best thing to do would be to repeat the operation from the start once more [to make sure that controller is on address 1] and then see if this problem persists. If so, you may have a faulty pLAN port so may have to get a replacement controller. Feel free to get in touch with us if you'd like to discuss this further on info@i-acs.co.uk
@@iacs thanks, I'll give that a go.
hello sir can you give us on how to copy the setting #1 and setting#2 in on PGD1 and PCOS1 by zamil brand.
what combination of keys to switch on/off from the keyboard?
The function that will turn the unit ON and OFF is entirelly dependant on the software running on the PCO controller, not on the addressing of the pLAN address of the display and controller, which is instead part of the firmware of the display. You will need to consult with the manufacturer of the Unit that would have most likelly developped a custom software for that machine.
thank you so much
@@StefanoLanzanithank you for this info Stefano. I'm commissioning a systemair AHU right now. PCO5 refuses to establish communication with presidency
nice tutorial...need more please
hi , i got some output after scanning using modbus. can you please help me to understand below output:XMT: [27][00][00][00][00][06][01][03][00][00][00][64] RCV: [27][00][00][00][00][4b][01][03][48][00][0b][00][79][00][03][00][0e][00][43][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][63][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00][00]
Hi I would like to asked on how to become executable the px graphics. Thanks
Do you know what is this software and how can i have it ?
How to reset a PGD1. The default code is not working.
i just replaced a pco1 controller today because the same no link, I read the boot up controller lights which were different everytime I tried to do a open circuit reset, I knew the controller was screwed. The cause the pool climate control maker, I will not mention a name made the air handler with an exposed evaporater line directly above the controller. Well bad bad design evaporator lines get cold and sweat water. Water driped on the board and fried it. New controller and after a 00 reset to the display and a few other software tweeks back to new.
Well done! Thanks for the post
Thanks for the tutorial.. very helpful. but i m lost a bit. why set the display to 32 again? cant it work with 00 address you set earlier?
The address 32 is an address in the pLAN network for shared display. Address 00 might work with certain software but not all... really depends on how the software has been coded by the manufacturer.
i-A.C.Systems I have a PCO3 and a PGD1 display. can I it work well? or I just need a PDG3. I have tried to follow the steps but I cant get it right Set 32 and 00 on terminal 1 private but no luck. After the screen times out I cant switch on and off from the display. do you have some ideas? how can I check the manufacturers address on the PCO3?
Hello, do you know where i can find a modscan 64 and modsim activation code...?
Just buy it
You are a genius…!!!!! 👏🏻👏🏻👏🏻
@@fritzinho00 hhhh
how to reset alarm
It depends on the alarm coming on the display. The alarm lists are coded in the software on the controller. The display is just a slave device to the controller which will output whatever the software is executing. Some Alarms are manual reset, some are automatic reset... if you click on the alarm bell button, the software should display the list of active alarms. Click the Alarm bell once more and you will acknowledge the alarm. When you press it one final time, you can reset the alarm. Obviously, if the alarm condition is still active, you will still be getting the alarm showing on the display.
iACS hi, so it means the chiller or other unit on which display is working on can keep working even the display shows "no link" because display is only showing/reading information from main board? But if during "no link" chiller wont start it means the problem accures in mainboard?