StructuralEngineering Modeling
StructuralEngineering Modeling
  • 6
  • 40 666
Scaling of Ground Motions using SeismoMatch
Detailed procedure to scale the ground motions according to the Indian standard design spectrum using SeismoMatch software.
มุมมอง: 6 481

วีดีโอ

PEER Ground Motions for Time History Analysis
มุมมอง 1K4 ปีที่แล้ว
Detailed procedure to download the ground motions from peer.berkeley. ground motion database.
Nonlinear Time History Analysis of RC Building
มุมมอง 18K4 ปีที่แล้ว
Nonlinear dynamic (time history) of reinforced concrete building frame using SAP2000; El-Centro time history function; Plastic hinge formation; Inter-storey drift.
Nonlinear Static Push Over Analysis of RC Building Frame
มุมมอง 7K4 ปีที่แล้ว
Pushover analysis of reinforced concrete building frame; Definition of plastic hinges; results.
Linear Time History Analysis
มุมมอง 2.7K4 ปีที่แล้ว
Linear time history analysis of RC building frame using SAP2000 - El Centro ground motion
Design of Reinforced Concrete Building Frame
มุมมอง 5K4 ปีที่แล้ว
Seismic analysis and design of RC building frame as per IS 456(2000) and IS 1893-Part 1(2016) using SAP2000. The analysis includes equivalent static and response spectrum methods

ความคิดเห็น

  • @DharmendraKushwahaveeru
    @DharmendraKushwahaveeru 24 วันที่ผ่านมา

    Dear Sir..What parameters are needed for the selection of ground motions for the seismic zone-IV (as per IS code) and how can I determine for the Shimla city? Hoping for your kind guidance. Thanks and Regard

  • @1u2rr2r5
    @1u2rr2r5 หลายเดือนก่อน

    TOO FAST

  • @vibhavchandrasrivastava941
    @vibhavchandrasrivastava941 4 หลายเดือนก่อน

    Nice! I want to plot the response of Load combination (E.g. Wind plus Wave) not just a single load case (Wind only). But in the Display -> Show Plot Function, I am unable to find Load Combination I have defined (E.g. 1.3 Wind + 1.2 Wave). Can you please help me with that?

  • @hingkauyeung4371
    @hingkauyeung4371 8 หลายเดือนก่อน

    Good

  • @hamedhghm
    @hamedhghm ปีที่แล้ว

    Hi im modeling bridge in csi bridge that s a software like sap and e tabs ...i want to set group of time history analysis for ida analysis but when i set scale factor of 0.1g to 0.8g or even 1.5g in some recorda for examlpe loma prieta record ... the hinges are in the linear phase and there arnt any rotation ...what should i do i need 0.1g to 0.8g rotation hinges for plot fragility curve can you help me?

  • @jayshah6293
    @jayshah6293 ปีที่แล้ว

    How to construct response spectrum..... You add spectra in define target.... How to make themmm ......plz tell us....thank you in advance

  • @yashkumar_5503
    @yashkumar_5503 ปีที่แล้ว

    Sir also make a video on steel frame structure

  • @Diago63
    @Diago63 ปีที่แล้ว

    How Can i contact U Sir

  • @abuamir3172
    @abuamir3172 ปีที่แล้ว

    Why did you divide the displacement by 3.5?

  • @abuamir3172
    @abuamir3172 ปีที่แล้ว

    Sir, could you make a video about Nonlinear Time History Analysis for steel structure?

  • @satyaeswarkolli8385
    @satyaeswarkolli8385 ปีที่แล้ว

    sir, how to contact you.

    • @structuralengineeringmodel486
      @structuralengineeringmodel486 ปีที่แล้ว

      Pl give me your mail iD

    • @osamamahmood4548
      @osamamahmood4548 7 หลายเดือนก่อน

      ​@@structuralengineeringmodel486Sir at 23:03 you mistaken by not clicking on Add to Existing load, you keep replace with existing load. in this way, the floor finish load is removed. but, i am ok. i being here, very thankful to you for your video on design

  • @satyaeswarkolli8385
    @satyaeswarkolli8385 ปีที่แล้ว

    sir, do we need to perform any analysis to show RS in Demand spectrum definition ( Function), for me RS option is not displaying.

  • @vinodkumar-zu4fl
    @vinodkumar-zu4fl 2 ปีที่แล้ว

    Thanks for a clear presentation of the video, but in gravity and nonlinear load case, usually we have to choose the mass source 1, but by default, you picked the previous option, is it correct to do?

  • @kumailmushtaq331
    @kumailmushtaq331 2 ปีที่แล้ว

    sir i followed all your steps that you have done in this video with the only difference that I am doing non linear analysis on the 10- storey steel structure. The step where you defined the hinges for concrete frame I have defined for steel but after I run the analysis to see how many hinges have gone into life safety or remained in immediate occupancy my deformed shape for time history only shows deformed shape without the coloured hinges ........

  • @infostanchio
    @infostanchio 2 ปีที่แล้ว

    Thank you sir sharing the knowledge of time history analysis..

  • @mahirbadanagki
    @mahirbadanagki 2 ปีที่แล้ว

    It is not matching. Also, it is changing the displacement time history significantly

  • @shahrulzamanabdulrahman3782
    @shahrulzamanabdulrahman3782 2 ปีที่แล้ว

    How to get response spectrum before we start the time history analysis in ur explanation 0.20 sec video

  • @mohammadmadu
    @mohammadmadu 2 ปีที่แล้ว

    sir is this blast load time history analysis

  • @farosparamananda912
    @farosparamananda912 2 ปีที่แล้ว

    Sir, if the building is 33th floor, how long the time to take for running?

  • @deoanand05
    @deoanand05 2 ปีที่แล้ว

    sir please tell me nonlear time history analysis can be done for FLAT SLAB also ??

  • @abadittadesse5892
    @abadittadesse5892 2 ปีที่แล้ว

    Thank you so much sir ,I appreciated. would you uploaded a video with base isolator please?

  • @RohitSinhacr7
    @RohitSinhacr7 2 ปีที่แล้ว

    Suppose the time history data says that "in units of g", then what should we put in scale factor? 1 or 9.81?

    • @iva3055
      @iva3055 2 ปีที่แล้ว

      9.81 if your sap units are meters.

  • @RajeshKumar-hr3bm
    @RajeshKumar-hr3bm 2 ปีที่แล้ว

    sir please give me el cetro data

  • @interiorarttv8449
    @interiorarttv8449 2 ปีที่แล้ว

    Hi can you please explain at 11:31 mins what does number 3.5 refer to?

  • @gunturjr9959
    @gunturjr9959 2 ปีที่แล้ว

    sorry sir can i get the software seismomatch cause the link is target spectrum not the software

    • @hemilcivil3909
      @hemilcivil3909 2 ปีที่แล้ว

      U can ask to seismomatch software provider... they are issued the academic version of it... U have to provide only your academic mail info...

  • @manishpal4378
    @manishpal4378 2 ปีที่แล้ว

    while defining mass sourse you only consider DL+0.25LL, in DL only wall loads are given. so it is better to select selfwt of elements + DL (wall loasds) + 0.25LL

    • @manishpal4378
      @manishpal4378 2 ปีที่แล้ว

      can you comments on this particular point?

  • @passangdikisherpa6910
    @passangdikisherpa6910 2 ปีที่แล้ว

    Sir ...load to an monitored displacement magnitude of ..is that target displacement ??

  • @simaijmulwar1382
    @simaijmulwar1382 2 ปีที่แล้ว

    nice video, Can you please explain how you decided total time steps 2688 in time history analysis, also can you please upload similar video using link elements for nonlinear time history analysis instead of plastic hinges, thanks

  • @ciciinfant2121
    @ciciinfant2121 3 ปีที่แล้ว

    Nice video Sir. For load pattern Push X and Push Y, whether it should be load pattern(EX and EY) or Acceleration UX/UY respectively Sir?

  • @dhirajahiwale569
    @dhirajahiwale569 3 ปีที่แล้ว

    Respected Sir, If vertical response spectrum is not present in seismic code of design, then out of these two function, which function should be used in linear time history analysis 1) Scaling of vertical ground motion time history as 2/3 of horizontal response spectra. OR 2) Scaling vertical ground motion time history as only horizontal response spectra. Looking for your guidance and support. Thank you.

    • @structuralengineeringmodel486
      @structuralengineeringmodel486 2 ปีที่แล้ว

      Generally, we can download acceleration time history functions in all the three directions (two hzl and 1 vcl). In such case, you can use the downloaded vertical ground motion and scale it for the analysis. In the absence of vertical ground motion, use 2/3 of horizontal acceleration time history.

  • @pavankumarkumar1222
    @pavankumarkumar1222 3 ปีที่แล้ว

    I have ah doubt in this . In YZ plane hinges are not formed that mean collapse not occurred in that plane or else structure is not displaced in that direction ?

    • @structuralengineeringmodel486
      @structuralengineeringmodel486 2 ปีที่แล้ว

      As the structure is pushed in x direction (XY plane, considering Y is vertical direction), plastic hinges are formed in beams oriented in that plane. If we run the push over analysis in z direction, the members oriented in the respective direction will get the inelastic response (formation of plastic hinges)

  • @mohamedanas1152
    @mohamedanas1152 3 ปีที่แล้ว

    Your videos are nice and explanation are very good. 1)Why are you applying plastic hinges to beam and column? Reason. 2)What will happen if I analyse without plastic hinges in my 40 storey steel building?

    • @structuralengineeringmodel486
      @structuralengineeringmodel486 2 ปีที่แล้ว

      1) Pushover analysis is a nonlinear static analysis. To get the nonlinear response of the structure, we should define the plastic hinges [in terms of moment - rotation (M-phi) curve]. Or else, we have to define the stress strain curves of the materials (for instance, concrete for RC frame and Rebar for reinforcements) used in the frame design. In such case, the results of plastic rotation values of the all the members need to be obtained after the analysis. These values have to be verified with the permissible values suggested by various building codes (ASCE41, FEMA356 or ATC40, etc) 2. You wont get the inelastic response if you dont define the plastic hinges. Or, As i said in the first point, you have to define stress-strain curve for the steel material to observe the nonlinear behaviour.

  • @krishnavenichevvu136
    @krishnavenichevvu136 3 ปีที่แล้ว

    sir how did you create Indian standard response spectrum? and what is target spectrum actually? please reply

    • @structuralengineeringmodel486
      @structuralengineeringmodel486 3 ปีที่แล้ว

      drive.google.com/file/d/1nUEwe6FdKoX856A5OTZigz2ykGa1DqBC/view?usp=sharing

    • @krishnavenichevvu136
      @krishnavenichevvu136 3 ปีที่แล้ว

      Thank you so much sir

    • @geotechtr3792
      @geotechtr3792 3 ปีที่แล้ว

      @@structuralengineeringmodel486 Sir seismomatch download software drive link? Thanks

  • @choimeisemdok
    @choimeisemdok 3 ปีที่แล้ว

    Sir, what is the difference between linear and non-linear time history analysis? Is it possible to conduct non-linear time history analysis in Staad Pro?

    • @structuralengineeringmodel486
      @structuralengineeringmodel486 2 ปีที่แล้ว

      There are two types of nonlinearities such as material and geometric nonlinearity. Here in the video, i used material nonlinearity for the analysis. For nonlinear time history analysis, nonlinear stress-strain values need to be defined (or plastic hinges) to obtain the nonlinear behaviour of the building. For linear analysis, we define elastic modulus, yield strength (or compressive strength), poisson's ratio. we can not get the inelastic behaviour with these material properties.

  • @malathyrb1174
    @malathyrb1174 3 ปีที่แล้ว

    sir, I would like to thank you so much for the lecture. sir, May I know why you have chosen p-delta large deflection than the p-delta effect? adding to that.. if time permits can you please upload lecture on nonlinear time history analysis of aluminium frame and steel frame as its cost effect for experimental work.

  • @sug1998
    @sug1998 3 ปีที่แล้ว

    Sir maximum displacement is H/500 ...drift is 4% H.... Where h =ht of bldg....why you hv used drift in place of displacement?

    • @structuralengineeringmodel486
      @structuralengineeringmodel486 3 ปีที่แล้ว

      push-over analysis results are based on the performance levels of the structure. There are four performance levels (Immediate occupancy (IO), Life safety (LS), Collapse prevention (CP) and Collape (C)) which based on the inelastic behaviour (i.e. plastic hinge formation). So, the maximum displacement the structure can experience corresponding to collapse state (C) according to FEMA356 is 4% of total height of the structure. Thats why, the said value is defined for the analysis. However, the structure will not be pushed to the defined value (4%H). The analysis will be ended within the 4% itself if the structure is designed properly.

  • @minarozza5207
    @minarozza5207 3 ปีที่แล้ว

    How to optain structure time period from sap

  • @shahkar_alam
    @shahkar_alam 3 ปีที่แล้ว

    good job, can you send me the software link.

  • @sanketsawant3
    @sanketsawant3 3 ปีที่แล้ว

    Can you please provide the steps for non-linear time history analysis of steel structure in ETABS?

  • @vedantclasses9313
    @vedantclasses9313 3 ปีที่แล้ว

    From where can I get that el centro.txt file?

    • @structuralengineeringmodel486
      @structuralengineeringmodel486 3 ปีที่แล้ว

      Visit peer.berkeley ground motion database

    • @Constructiongyan14
      @Constructiongyan14 3 ปีที่แล้ว

      it is present in your database of your computer only Local Disk :C , then Program files then computer and strucutres then Etabs 18 or Etab 16 then time history funtion . you will get all time history file predefined canbe opened in notepad

  • @darshilkalariya6040
    @darshilkalariya6040 4 ปีที่แล้ว

    Could you provide the time history file?