Cell Constant and Temperature Calibration of DSC 2500. TA Instruments
This video tells how step by step direction how to calibrate cell constant and temperature calibration of DSC 2500 from TA instrument using Trios software.
มุมมอง: 135
วีดีโอ
Tzero Calibration (Baseline Calibration) of DSC 2500. TA Instruments
มุมมอง 549ปีที่แล้ว
This video tells how step by step direction how to calibrate Tzero calibration of DSC 2500 from TA instrument using Trios software.
Vertical Flammability Test of V2 Type plastics (ASTM D3801). UL 94 Flammability Test
มุมมอง 409ปีที่แล้ว
Vertical Flammability Test of V2 Type plastics (ASTM D3801). UL 94 Flammability Test
Vertical Flammability test of V0 type plastic (ASTM D3801). UL94 Flammability Test
มุมมอง 611ปีที่แล้ว
Vertical Flammability test of V0 type plastic (ASTM D3801). UL94 Flammability Test
Horizontal Flammability Test of V0 type plastics (ASTM D635-06). Horizontal Burn Test
มุมมอง 2.1Kปีที่แล้ว
Horizontal Flammability Test of V0 type plastics (ASTM D635-06). Horizontal Burn Test
Horizontal Flammability test of V2 type plastics (ASTM D635-06)
มุมมอง 363ปีที่แล้ว
Burning test of plastics according to UL94
Horizontal Flammability Test (ASTM D635-06) of Flammable Polymers
มุมมอง 490ปีที่แล้ว
UL94 Flammability Test ASTM D635-06 Rate of burning of plastics in a Horizontal Position
Sample Preparation for Peel strength Test of Pressure sensitive adhesive
มุมมอง 3853 ปีที่แล้ว
Sample Preparation for Peel strength Test of Pressure sensitive adhesive
Loop Tack test Complete- Pressure sensitive Adhesive (ASTM D6195)
มุมมอง 1103 ปีที่แล้ว
This video demonstrated to utilization of ASTM D6195 to conduct the Loop Tack test of pressure-sensitive adhesive.
Real-time FTIR analysis of UV-cured acrylic polymer
มุมมอง 3963 ปีที่แล้ว
This video demonstrated how to prepare acrylic monomers to conduct FTIR analysis to measure the %conversion vs time. Training on ThermoScientific NICOLET IS50 FTIR
Complete Peel Strength Test-ASTM D903 − 98, ASTM F88
มุมมอง 6973 ปีที่แล้ว
Peel Strength of Pressure Sensitive Adhesive Using InstratonTensile Tester,
ASTM D3654/D3654M − Shear Strength Testing of Pressure Sensitive Adhesive
มุมมอง 2.6K3 ปีที่แล้ว
ASTM D3654/D3654M − Shear Strength Testing of Pressure Sensitive Adhesive
Corona Treatment and Apply Coating on flexible substrate using Rod Coater
มุมมอง 533 ปีที่แล้ว
Corona Treatment and Apply Coating on flexible substrate using Rod Coater
Plot 3D Hansen Solubility Sphere Using OriginPro
มุมมอง 2.2K3 ปีที่แล้ว
Plot 3D Hansen Solubility Sphere Using OriginPro
Hansen solubility parameter (HSP) of Nanoparticles using Matlab
มุมมอง 8323 ปีที่แล้ว
Hansen solubility parameter (HSP) of Nanoparticles using Matlab
Nitrogen Balloon for inert atmosphere chemical Reaction/Synthesis
มุมมอง 10K3 ปีที่แล้ว
Nitrogen Balloon for inert atmosphere chemical Reaction/Synthesis
Graduation of Taufiq, pomy and shakir vai
มุมมอง 129 ปีที่แล้ว
Graduation of Taufiq, pomy and shakir vai
Thank you so much for this video. It shows that you care.
How to do annual validation on it ?
What is the measureable time?
Thanks, it was very helpful! Just the transparency is not working, no matter what value I set up, it doesn't change, only at 100% the sphere dissapears. I followed your steps precisely
Nice but in the video i cant see on focus the box containing the standard saphire for calibration and here i have many many substance stardard like zinc, tin, adamantane and indium i have the saphire calibration MDSC but i dont know the mass. And this make me confused because i need make a calibration alone and i dont want doing bad.
This is a very detailed and insightful breakdown of ways to craft an effective job resume. Greatly appreciate this video, Anik bhai!
Is this for imprinting polymers?
yes you can do this for imprinted polymer
You did not show how we plug solvents ?
Dont you have a schlenk-manifold or something? I would not call this "inert" atmosphere...just slightly better than regular atmosphere
Agreed
Most of the synthesis experiments are done using same procedure if your lab has no well organized schlenk-manifold. It is much easier and cheaper option.
I did this all through grad school. But I didn't cut the balloon, and held it to the needle with rubber bands.
Why cut the balloon?
why put the needle at the 2:30? is it necessary?
in order for the gas from the balloon to replace the air in the system, it is necessary that the air from the system escape into the atmosphere just through this needle
@@ThePaivel got it thanks
Nice video sir. I have a question sir..I operated instrument recently 1 week ago. I cleaned up surface. I took bkg reading. Then I put sample and analysed the spectra.. after scanning of 60 scan. My IR was completed.. but in another data are not generated automatically, here in your analysis data generated that displayed automatically at (8-05 sec) in video
Live Saving! Thanks a lot :)
You're welcome!
Very helpful. Thanks for the nice explanation.
You are welcome!
Very helpful video! Might be worth reaching out to Charles/Hiroshi to post this on the official HSP or Pirika website?!
Nice training tutorial! I'm just wondering is there any difference in the procedure if I want to analyze the normal solid/liquid samples instead of your polymer films?
No difference
Could you share the pdf that you shown in this video?
Thank you for sharing the strategy Nuruddin bhai. Really appreciated for some real insight that you have shown here. Congratulations to your new job offer.