- 86
- 81 502
AlexGe
เข้าร่วมเมื่อ 25 ธ.ค. 2022
วีดีโอ
Three Phase Tuya WiFi Intelligent Circuit Breaker. Part 2
มุมมอง 59วันที่ผ่านมา
Tuya WiFi Intelligent Circuit Breaker Automatic Reclosure Protector 3P4W Power Meter Three Phase Reclosure Switch LCD Display 🔗Click & Buy: s.click.aliexpress.com/e/_oEz1c8j 🔗Click & Buy: s.click.aliexpress.com/e/_oBV1W6X
Three Phase Tuya WiFi Intelligent Circuit Breaker. Part 1
มุมมอง 130วันที่ผ่านมา
Tuya WiFi Intelligent Circuit Breaker Automatic Reclosure Protector 3P4W Power Meter Three Phase Reclosure Switch LCD Display 🔗Click & Buy: s.click.aliexpress.com/e/_oEz1c8j 🔗Click & Buy: s.click.aliexpress.com/e/_oBV1W6X
GREE Consola & GREE FAIRY
มุมมอง 915หลายเดือนก่อน
Testo : Digital Manifold s.click.aliexpress.com/e/_DdCHfAp s.click.aliexpress.com/e/_DCYuxCl s.click.aliexpress.com/e/_DlvFrM9 Bluetooth gauge s.click.aliexpress.com/e/_DDxMcOV s.click.aliexpress.com/e/_DFhtxiv s.click.aliexpress.com/e/_DnsAKTr s.click.aliexpress.com/e/_DlLZxwZ s.click.aliexpress.com/e/_DBSDvBL s.click.aliexpress.com/e/_DBNRymN Other brands manifold gauges: s.click.aliexpress.c...
Și iarăși rutina zilnică 5
มุมมอง 208หลายเดือนก่อน
Testo : Digital Manifold s.click.aliexpress.com/e/_DdCHfAp s.click.aliexpress.com/e/_DCYuxCl s.click.aliexpress.com/e/_DlvFrM9 Bluetooth gauge s.click.aliexpress.com/e/_DDxMcOV s.click.aliexpress.com/e/_DFhtxiv s.click.aliexpress.com/e/_DnsAKTr s.click.aliexpress.com/e/_DlLZxwZ s.click.aliexpress.com/e/_DBSDvBL s.click.aliexpress.com/e/_DBNRymN Other brands manifold gauges: s.click.aliexpress.c...
Pompa de caldura GREE 10kW GRS-CQ10Pd/NhH-M(O)gdf
มุมมอง 3.7K2 หลายเดือนก่อน
Testo : Digital Manifold s.click.aliexpress.com/e/_DdCHfAp s.click.aliexpress.com/e/_DCYuxCl s.click.aliexpress.com/e/_DlvFrM9 Bluetooth gauge s.click.aliexpress.com/e/_DDxMcOV s.click.aliexpress.com/e/_DFhtxiv s.click.aliexpress.com/e/_DnsAKTr s.click.aliexpress.com/e/_DlLZxwZ s.click.aliexpress.com/e/_DBSDvBL s.click.aliexpress.com/e/_DBNRymN Other brands manifold gauges: s.click.aliexpress.c...
Pompa de caldura BAXI 8kW AWHP 8 MR-2
มุมมอง 8722 หลายเดือนก่อน
Testo : Digital Manifold s.click.aliexpress.com/e/_DdCHfAp s.click.aliexpress.com/e/_DCYuxCl s.click.aliexpress.com/e/_DlvFrM9 Bluetooth gauge s.click.aliexpress.com/e/_DDxMcOV s.click.aliexpress.com/e/_DFhtxiv s.click.aliexpress.com/e/_DnsAKTr s.click.aliexpress.com/e/_DlLZxwZ s.click.aliexpress.com/e/_DBSDvBL s.click.aliexpress.com/e/_DBNRymN Other brands manifold gauges: s.click.aliexpress.c...
Reparatie placa unitate externa (sau iarasi rutina)
มุมมอง 5772 หลายเดือนก่อน
Testo : Digital Manifold s.click.aliexpress.com/e/_DdCHfAp s.click.aliexpress.com/e/_DCYuxCl s.click.aliexpress.com/e/_DlvFrM9 Bluetooth gauge s.click.aliexpress.com/e/_DDxMcOV s.click.aliexpress.com/e/_DFhtxiv s.click.aliexpress.com/e/_DnsAKTr s.click.aliexpress.com/e/_DlLZxwZ s.click.aliexpress.com/e/_DBSDvBL s.click.aliexpress.com/e/_DBNRymN Other brands manifold gauges: s.click.aliexpress.c...
Pompa de caldura 16kw BAXI AWHP 16 TR-2R3
มุมมอง 2.4K3 หลายเดือนก่อน
Colectie echipamente si accesorii pentru HVAC Testo : Digital Manifold s.click.aliexpress.com/e/_DdCHfAp s.click.aliexpress.com/e/_DCYuxCl s.click.aliexpress.com/e/_DlvFrM9 Bluetooth gauge s.click.aliexpress.com/e/_DDxMcOV s.click.aliexpress.com/e/_DFhtxiv s.click.aliexpress.com/e/_DnsAKTr s.click.aliexpress.com/e/_DlLZxwZ s.click.aliexpress.com/e/_DBSDvBL s.click.aliexpress.com/e/_DBNRymN Othe...
DC Blower Video 2
มุมมอง 1223 หลายเดือนก่อน
In cazul meu motorul defect si motorl nou aveau rezistentele identice intre toate bornele conectorului. Nu am putut diferentia motorul defect de cel bun.
..si iarasi capacitor defect la climatizor
มุมมอง 1714 หลายเดือนก่อน
..si iarasi capacitor defect la climatizor
Dezasamblam unitatea interna a climatizorului
มุมมอง 3854 หลายเดือนก่อน
Dezasamblam unitatea interna a climatizorului
Și iarăși repetăm testul la aciditate...
มุมมอง 4444 หลายเดือนก่อน
Și iarăși repetăm testul la aciditate...
Mitsubishi MUX-18RV + MSC-09RV din antichitate
มุมมอง 8725 หลายเดือนก่อน
Mitsubishi MUX-18RV MSC-09RV din antichitate
#Shorts Interconectare climatizor in 3 fire
มุมมอง 1.6K5 หลายเดือนก่อน
#Shorts Interconectare climatizor in 3 fire
...și iarăși încărcăm climatizorul după superheat
มุมมอง 2K6 หลายเดือนก่อน
...și iarăși încărcăm climatizorul după superheat
Cum alegem vasul colector pentru panoul solar
มุมมอง 9177 หลายเดือนก่อน
Cum alegem vasul colector pentru panoul solar
Salut,cum pot sa te contactez ? Mersi mult
Bună Alex ,am o pompa 16 kw midea am pierdut freonu am încărcat dar acum se aude un zgomot că și cum ar fierbe ,ce ar putea fi?
Buna. Sunteti sigur ca a fost incarcat cu cantitatea exacta de freon? Vidarea a fost facuta corect? Unde este sursa acestui zgomot?
Where is wire cable for outdoor unit?
th-cam.com/video/aAf-zAOptRs/w-d-xo.html
Se poate pleca din pompa și cu țeava de 26?
Conteaza capacitatea pompei si rezistenta circuitului hidraulic. Daca pompa pompeaza intr-un puffer in imediata apropiere de ea, atunci nu vor fi probleme, daca pompeaza direct in circuitul de calorifere atunci trebuie facute calcule. In general Pexal-ul in sine are o capacitate de transport a lichidului termic buna, problema e in conectori si inbinari care fac o ingustare drastica al diametrului initial.
@AlexGe81 vă mulțumesc .mia fost de ajutor răspunsul dumneavoastră.imi puteți lăsa un număr de contact?
Mine is monoblock and its much louder :S
12000 dă bătău😂😂
Nu 12000 dar 18000. Pot sa-i zic si British thermal unit dar bătău e exact pe înțelesul tuturor
Felicitari, oferi informatii pretioase.
Салют! Интересные детали. Слежу за вашими видео по поводу солнечной системы. Сколько трубок в вашем коллекторе и какой литраж накопителя?
Спасибо. По поводу ваших вопросов: Ответ 1 th-cam.com/video/o3SiAnHlI-0/w-d-xo.html и ответ2 th-cam.com/video/4hJ3VhK1YG4/w-d-xo.html
Salutare Alex, eu am niste intrebari cu referire la colector solar. Mai ales la sistemul drain back. Cum pot sa va scriu? poate o adresa de mail sau tel.? merci
scrieti aici. daca este informatie relevanta acestui subiect, o vor cunoaste si altii.
@AlexGe81 am sistemul nou gata construit, dar cu vas de expansiune. M-ar interesa dacă a-ți putea să - mi calculați/construiți unul de Drain Back, până încă nu am cumpărat antigelul. Mulțumesc anticipat
@@olegtimbalistru9027 Incarcati un videou cu sistemul d-voastra. Daca sistemul este construit presurizat atunci el trebuie modificat pentru a funcuina corect. Vasul de stocare trebuie pozitionat mai sus ca pompa de circulatie. Inaltime la care pompati lichidul trebuie sa fie mai mica de cat limitele de inaltime ale pompei. Tehnic vasul de stocare si cel de expansiune sunt diferite (nu exista acea minge de cauciuc)
@@AlexGe81 salutare, Mulțumesc pentru videoul de astăzi. Totuși poate un desen tehnic a vasului in sectiune m-ar ajuta mai mult. Oricum ce ați filmat până acum este de lăudat! Știu că este o mare muncă.
Salut. Chiar e foarte simplu. Urmariti videoul acesta: th-cam.com/video/4hJ3VhK1YG4/w-d-xo.html va va fi totul clar
Bună domnul Alex ce brend de pompă de căldură ați putea recomanda pentru o casă 100 metri pătrați neizolată mersi mult
Mitsubishi, Daikin , Nibe . Sunt Rolls-Royce in lumea pompelor de caldura. Asta nici de cum nu semnifica ca Hitachi, Hisense, AUX, GREE sunt rele.
Bravo!!!
Am si eu modelul asta de 8
Dați un feedback referitor la pompă. De cât timp o aveți, consum, confort, ce tip de sistem de încălzire aveți, face acm sau nu?
Salut, poti sa-mi spui cum e experienta ta ? Vreau sa-mi pun si eu o pompa de caldura si ma gandeam la gree, caci am experienta buna cu ei, dar un instalator mi-a recomandat sa caut altceva caci el a montat una si modulul din interior era galagios tare, poti sa-mi spui cum se comporta la tine ?
@@armonak salut. Eu le montez doar. Am pus diferite branduri. Referitor la acest gree din video, nu face gălăgie la interior, nu prea înțeleg cine ar face. Sursele de gălăgie sunt pompa de circulație (vize videoul), vana cu 3 căi și propriu-zis freonul care trece prin schimbător. Este o distanță minimă între unități(probabil el nu o respectă), așa freonul poate face zgomot prin țevi (un șuerat specific). Am vorbit de câteva ori cu proprietarul și era tare mulțumit (are și fotovoltaice pe casă).
@alex.ge17 a zis că pompa de circulație e gălăgioasă, deci sa nu fie cu defect mai degrabă. Ai ceva branduri cu care ai experiență mai plăcută ? Eu inca nu sunt decis ce să-mi pun
E buna aceia care va fi capabila sa functioneze multi ani inainte cu efiecienta maxima si defectiuni minime. Inca nu am intalnito. Mitsubishi, Daikin sau recomandat a fi pompe performante , Nibe la fel. Hitachi are o interfata foarte "user friendly". LG, Samsung... functioneaza si ele.
vorba cu jucărie e tare, mulțumesc pentru content, e de folos
Bravo Alexandru! Un proiect de succes!
Спасибо))))
Bună ziua , Am legat serpentina de la boiler la centrală fără pompă . Dar care este motivul de nu ajunge apă caldă la serpentina? Cum pot scoate aerul din serpentina?posibil acesta să fie motivul
prea putina informatia. aratati schema, faceti un video si incarcati-l pe youtube
Bună ziua , Pot lega serpentina de la boiler la centrala peletii fără sa mai pun pompă de recirculare pentru boiler ?
banuiesc ca fara vana cu 3 cai nu va veti descurca. Cum veti dirija cu incarcarea boilerului ? Cum veti limita temperatura limita de incarcare a boilerului? Cum veti dirija agentul termic spre sistemul de incalzire si spre boiler, dupa necesitate?
Salutatre, pompa de 16 kw pentru ce suprafata este ??
depinde de eficienta termica a casei si regimul de temperatura dorit. Aceasta de 16kw la ~200m2
Salut in ce zona montezi in tara?
toata R. Moldova
Îmi dai un Nr de tel să mă ajuți cu un sistem apa caldă și cazan electric.
Telegram: @Alexge2030
Salut!iarna da randament?
Clientul nu se plange. Un test cu randament nu am facut.
Pumy-p100vhmb n está funcionando qual fica pra verifica o sistema. Ventilador liga mas compressor n funciona..
Corect
salut, cati litri de glicol ti-au initrat in sistem?
Salut.Nu este glicol, este apa obisnuita. E foarte simplu de calculat. In pasaportul tehnic al colectorului scrie exact ce volum de lichid incape in el. Apoi volumul traseului (formula volumul cilindrului). Apoi volumul serpentinei boilerului (la fel este informatie exacta in pasaportul boilerului). Si, ultimul element este grupul de pompare la fel e f usor de aflat. In cazul meu este ~ 7-8litri datorita acelui vas de stocare.
@@AlexGe81 mulțumesc pt răspuns. Vasul de expansiune nu intra in calcul?
@@alexandrusaidufis5955 NU este vas de expansine, Este un vas de stocare a lichidului cand pompa se afla in repaus. In acel vas curge toata apa din colector si din teava. In asa fel la exterior nu ramaine nici un pic de apa(nu are ce ingheta). Vedeti si alte clipuri unde eu vorbesc in detaliu despre acel vas de acumulare.
Salut eu am la fel pe casă și vreau să plec de-acasă vrun an ce aș putea să-i fac să nu mai dea apă caldă?
Salut. Minim si cel mai rapid este sa scoateti lichidul din circuitul colectorului (colectorul orcum va fi expus la temperaturi foarte ridicate in timpul verii). Maxim ce puteti face, este sa acoperiti colectorul cu un material opac si rezistent la vanturi pentru a proteja colectorul de temperaturi inalte.
nu stiu ce ai facut acolo.... dar tre sa ai presiune pe instalație macar 3 3,5 bari. citeste manualul pompei si a colectorului solar
citeste despre tehnologia "drain-back". Nu are nevoie instalatia sa fie in presiune, nu are nevoie instalatia de vas de expansiune, nu are nevoie instalatia de antigel.
Cum cativa ohmi intre rosu si negru,cand e ok?.,asta inseamna scurt.Intre rosu si negru trebuie sa fie sute de kohmi,daca nu megaohmi.
astept altul nou.Voi arata rezistentele
Da, ma dus in eroar un alt motor AC. Ati remarcat absolut corect, e >1Mhom. Voi corecta postarea
@@AlexGe81 Apreciez răspunsul,numai bine.
Motoru asta e de externă
e de la caseta interna
@@AlexGe81 ok,scuze,eu nu prea lucrez pe casete,95% pe splituri
Salutare, de unde ati cumparat ceasurile digitale? :)
de la chinezi. Propriuzis manometrele sunt mastercool.
Mitsubishi Heavy Harukaze Pro ......Top.
Nu înțeleg echilibrarea fazelor in acest tablou, iar pe un RCD normativ spune ca putem monta maxim 8 MCB-uri.
NU exista echilibrare de sarcina pe faze, nu este cazul. Este panoul electric pentru cazangerie si o camera alaturata. Iluminatul este LED cu sarcina totala ~100w Prizele, poate un polizor unghiular candva, cumva (hai sa zic o sarcina totala pentru prize <16A), Echipamentl vital pentru cazangerie trece peste un UPS de 500VA.... deci acea faza la fel pot sa o consider ca "se joaca" (nu este incarcata). Urmariti videoul pana la sfarzit, eu comenteze de ce l-am structurat asa Un link va rog cu acel normativ. Al meu automat diferential este trifazat, pe fiecare faza pot pune pana la 8 autoate de sarcina, nu incalc regulile. Trebuie sa am multa grija la repartizarea sarcinei in cazul in care exista echipament trifazat, altfel o repartizare aparenta e suficienta (am echipament de monitorizare si siguranta la intrare in panoul principal si este conectat la smart-house` ul meu)
Va dau dreptate, tevile acelea de curpu au o rezistenta mai mica decat ar avea un conductor de 1.5mmp, dar aici ideea este de echipotentializare, normal si recomandat este sa conectam direct si unitatea externă la împământare, nu degeaba a pus fabricantul acea conexiune acolo. Numai bine!
Salut. Si, mersi pentru un comentariu constructiv. NU neg nici o clipa ca e OK sa fie conectat groundul la acea mufa externa, dar cand te afli la o montare la capatul pamantului si fizic nu ai acces la acel cablu cu 4 sau 5 fire atunci gasesti iesire din situatie ca sistemul sa functioneze fara a afecta siguranta si buna functionare a echipamentului. Asta si am aratat in aceasta postare. Acum de ce se dubleaza acel pin de ground si la exterior si la interior, deoarece este optiunea de a conectate alimentarea atit la unitatea externa atit si la ce interna de aceia au standartizat cumva acea mufa cu multe conexiuni. Acele tevi de cupru apriori au o rezistenta mai mica ca un fir de 1,5mm si sansele ca se vor deteriora ambele simultan este infirm mica de cat acel fir subtire ca poate sa fie rupt.
SuperheatCalc.
Superheat prea mare decât țintă...se adaugă freon. Superheat mai mică decât țintă..se scoate freon
Va trebuie un termometru sa masoare temperatura termometrului umed...la interior,si temperatura temometrului uscat pentru exterior. Introduceti datele in program si va spunte Tinta superheat. Cu placere!
Este un program pe net
Incercati cu Superheat Target
Dar cum se determina 'tinta'de superheat?
th-cam.com/users/shortslJ6iVEBkWDQ
Dina cest motiv ni e bine sa monteze dorei ac ci firma specializqta
Vezi ca nu e chiar asa. Pinul de impamantare trebuie sa fie cuplat la priza de pamant. Tevile vin din motor care e asezat pe tampoane din guma. Trebuia cablu cu 4 fire. Am pus mana pe o unitate externa la o vila unde eram cazat si curenta. Sigur a procedat ca tine. Nu te juca cu viata semenilor tai!
Imi permit sa va contrazic. Unitatea interna are priza cu impamintarea montata corect. Unitatea interna daca o deschideti are un fir cu impaminatre conectat la corpul vaporizatorului (care este din aluminiu+cupru). Acum, acel vaporizator din interior, este conectat rigid cu acele 2 tevi de cupru la unitatea externa. La unitatea externa acele tevi de cupru sunt cuplate rigid la acei 2 robineti care la rindul lor sunt insurubati de corpul unitatii externe; OK , puteti reprosa ca nu e coexiune sigura, urmeaza condensatorul extern care este montat direct pe corpul unitatii externe . D-voastra cumva spuneti ca compresorul este pe pernute de guma care-l izoleaza de corpul unitatii externe; pai tocmai el(compresorul) si poate sa fie sursa de electrocutare(fiind izolat nu are cum sa va electrocuteze) o alta sursa este ventilatorul , o alata sursa este un fir care sa ros si se atinge de corpul climatizatorului, insasi carcasa climatizorului de la sine nu are cum sa va electrocuteze. Rolul impamintarii la echiamente este indirect pentru protectia la electrocutare. Ideia este urmatoarea: daca este o impamintare corecta a echipamentului si apare o defectiune cu scurgere de curent atunci acel curent prinde a curge vertiginos prin impamintare. Acum acest curent de scurgere creaza un scurtcircuit intre live (acel fir sau componenta defecta) si ground in asa fel dezjunctorul(automatul, siguranta) se decupleaza (se arde daca e siguranta fuzibila) intr-o fractiune de secunda si intrerupe alimentarea cu curent. Rolul unei impamintari corecte este sa protejeze firele electrice si tot circuitul electric din casa (apartament) impotriva topirii si incendiului si alte nenorociri care pot fi cauzate de firele electrice care se topesc cand are loc scurtcircuitul. Daca echipamentul este defect si are scurgere de curent atunci automatul (montat corect) va decupla circuitul inainte de a pune mana d-voatra pe acel echipament (rezistenta impamintarii este cu mult mai mica de cat al corpului uman). Acum daca doriti o protectie la electrocutare sau daca umblati prin echipamnete aflate sub tensiune, atunci utilizati automatele diferentiale (de dorit cu curentul de scurgere de 10mA). Veti simti doar o intepatura daca va atingeti intamplator de firul aflat sub teniune. Tocmai acest gen de echipament de protectie este pentru protectia persoanei la electrocutare.
Nu reușesc să setez parametri în asa fel să-mi facă apa la 60 grade la T3
T3 este sonda superioara care este montata in acumulatorul d-voastra de apa. T3 nu ajunge la 60 de grade la finele unei zile insorite din mai multe motive. Or este consum de apa si mereu intra o cantitate de apa rece in boiler (banal apa in acumulator nu poate sa ajunga la asa temperatura). Alta cauza este voluml de apa pe care trebuie sa-l incalzeasca colectorul solar (banal nu ajunge energie termica suficienta pentru a ridica apa in boiler la temperatura dorita). Trebuie dimensionati colectorul pentru a satisface cerintele d-voastra.
Bună seara , Vă rog frumos să-mi spuneți ce parametri ați setat la DTO,DTF,DTS?
acesti parametri sunt individuali pentru fiecare sistem in parte. Cifrele mele nu sunt releveante pentru sistemul d-voastra
Am o intrebare,daca se poate si daca aveti idee.Am montat un ac lg nou acum o saptamana,dupa montare a mers fara probleme,vreo 4 zile nu l-am mai pornit fiindca nu a fost nevoie,azi cand l-am pornit,unitatea exterioara nu a vrut sa porneasca.Nu mai vrea sa meraga de nici o culoare,nici motorul nici spiterul.Daca il scot din priza spliterul se deschide dar dupa 30s-1m se inchide si nu vrea sa se deschida,deoarece unitatea externa nu porneste.Am verificat conexiunile electrice si nu sunt probleme,gaz,cand apas stutul acela vad ca iese,deci are,nu stiu ce ar avea.
actiuni standarte sunt: verificarea conexiunilor si a freonului asta in cazul in care echipamentul nu indica nici o eroare pe display. Unele echipamenet sunt dependente de Live si Neutru la alimentare. Daca este conectat la o priza, banal inversati stecherul si incercati. Daca firul vine direct de la un dezjunctor, deconectati complet alimentarea climatizorului pentru 15min, apoi realimentati si incercati. Altfel chemati mesteri.
@@AlexGe81 Multumesc de raspuns,am rezolvat problema cu un electrician.Problema a fost urmatoarea:Spiter-ul are 3 posturi ptr cablu electric si o impamantare,la mine era L1,N2 si C3.Motorul are 5 posturi,respectiv:L,N,L1 N2,C3 si impamantarea.Eu am plecat din spliter,de la L1,N2 si C3 iar in motor le-am legat identic,adica la L1 N2 si C3,ptr ca asa mi-a zis cel cu care l-am montat.Electricianul a schimbat faza si nulul din motor,de la L1 si N2 la L si N.A zis ca,curentul in motor trebuie sa intre pe principal si el îi da comanda la spliter pe celelalte posturi.Asta a fost toata smecheria.Nu stiu cum a functionat atunci cand l-am montat,electricianul a zis,ca nici el nu isi explica! Hai,o seara frumoasa si sa bata Romania!🤣
Bună ziua , Azi la ora 15:30 senzorul T1 colector a avut din nou eroare 300 grade -160 ….pompa mergea la 100%procente , dupa 15 min .a revenit la normal… care este cauza ?
Am rezolvat ( contact imperfect la t1 controler)
Bună seara , Vă rog frumos să-mi spuneți ce parametri ați setat la DTO,DTF,DTS?
Bună dimineața, De ce dimineața la prima oră controlerul sr208c o ia razna la senzorul T1 (colector),(cresc și scade haotic gradele ) și pornește și pompa
Deoarece energia livrata de soare inca este foarte mica la orele diminetii. Cand pompa prinde a mana lichidul prin colector temperatura pe colector prinde a scadea rapid si controlerul da semnal la oprire pompa.Cand pompa se opreste, iarasi temperatura pe colector incepe rapid a creste. Acest proces este normal la primele ore al diminetei
Va salut,am un aer condiționat montat la casa si vara trecuta a mers insa acum cand ii dau drumu nu baga aer rece doar ventileaza aerul, compresorul din unitatea exterioara pornestesi ventilatorul, din ce am observat se raceste doar teava subtire cea groasa de joasa presiune nu da semne ca s-ar raci ar trebui sa se raceasca si ea sau e normal asa? de la ce ar putea fi?
Salut. Ati pierdut freonul. Este scurgere, mai intai inlaturati scurgerea apoi incarcati climatizorul cu freon. Nu-l expluatati asa(se va defecta daca trece in vid.)
Va salut,am un aer condiționat montat la casa si vara trecuta a mers insa acum cand ii dau drumu nu baga aer rece doar ventileaza aerul, compresorul din unitatea exterioara pornestesi ventilatorul, din ce am observat se raceste doar teava subtire cea groasa de joasa presiune nu da semne ca s-ar raci ar trebui sa se raceasca si ea sau e normal asa? de la ce ar putea fi?
Lipsă freon
Bună ziua, La 30 grade afară , este în regulă colectorul (20 tuburi ) maxim 60 grade și apa în boiler(200 l) 55 grade Nu poate mai mult sau trebuie să umblu la setările controlorului ?
da, e in regula asa