Martin Heating & Cooling
Martin Heating & Cooling
  • 46
  • 37 560
How I like the RLS Original AC/R Press Fittings!
My take after installing a bunch of this fittings on another job. It’s a very positive experience! #hvacfamily #airduct #hvacmaintenance #airconditioning #refrigeration #plumbing #piper
มุมมอง: 65

วีดีโอ

Mobile Home Chimney Gone Wrong!
มุมมอง 22หลายเดือนก่อน
Mobile home roof jack replacement.
ECM Motor Speed Setting, Does It Need Adjusting?
มุมมอง 262 หลายเดือนก่อน
Checking on my speed setting for an ECM motor. I thought it was to high, but looks like I’ve already dropped it down to the next setting from the factory setting. To much air flow for the size of the air handler, you’ll be noisy and you’ll pull condensation from the coil and have a wet blower and box, plus mold development. That’s what I thought might of caused the mold in this unit. But actual...
Coil Cleaning With Pressure Washer
มุมมอง 342 หลายเดือนก่อน
Coil Cleaning With Pressure Washer
Flex Duct Is Ok, But Not To Much!
มุมมอง 2943 หลายเดือนก่อน
Flex Duct Is Ok, But Not To Much!
Hvac Supply House Visit!
มุมมอง 473 หลายเดือนก่อน
Hvac Supply House Visit!
Navien Water Heater Failure
มุมมอง 583 หลายเดือนก่อน
Navien Water Heater Failure
Hvac Air Filter Plugged Dirty Time To Replace!
มุมมอง 853 หลายเดือนก่อน
Hvac Air Filter Plugged Dirty Time To Replace!
AC Capacitor End Of Life Test
มุมมอง 7863 หลายเดือนก่อน
AC Capacitor End Of Life Test
Package Unit Maintenance Grief!
มุมมอง 103 หลายเดือนก่อน
Package Unit Maintenance Grief!
Old Dirty Burnham Boiler Tune Up 😩
มุมมอง 2843 หลายเดือนก่อน
Old Dirty Burnham Boiler Tune Up 😩
Oil Burner Maintenance Basic Items 👍🏻
มุมมอง 223 หลายเดือนก่อน
Oil Burner Maintenance Basic Items 👍🏻
Fujitsu Evaporator Coil Leaks/Replacement/Plus Deep Cleaning!
มุมมอง 7933 หลายเดือนก่อน
Fujitsu Evaporator Coil Leaks/Replacement/Plus Deep Cleaning!
Call back!!! Need to insulate those lines better 😞
มุมมอง 463 หลายเดือนก่อน
Call back!!! Need to insulate those lines better 😞
Old R22 Loses Its Charge Again!
มุมมอง 8453 หลายเดือนก่อน
Old R22 Loses Its Charge Again!
Hvac estimates when your already to busy?
มุมมอง 633 หลายเดือนก่อน
Hvac estimates when your already to busy?
Hvac tech travel part 2
มุมมอง 2811 หลายเดือนก่อน
Hvac tech travel part 2
Hvac tech traveling for parts
มุมมอง 4011 หลายเดือนก่อน
Hvac tech traveling for parts
Milwaukee 18volt/True Blue Single house/Vacuum pump setup/Snapshot! 😉
มุมมอง 512ปีที่แล้ว
Milwaukee 18volt/True Blue Single house/Vacuum pump setup/Snapshot! 😉
Service Call-Plugged Burner Nozzle/No Hot Water!!! 😱
มุมมอง 97ปีที่แล้ว
Service Call-Plugged Burner Nozzle/No Hot Water!!! 😱
Heatpump/Ductless split/Maintenance/Cleaning with Port-A-Blaster!!!!
มุมมอง 100ปีที่แล้ว
Heatpump/Ductless split/Maintenance/Cleaning with Port-A-Blaster!!!!
Miller/Nordyn Oil burner Tune Up/Maintenance/Cleaning/Service/Mobile home
มุมมอง 1.1Kปีที่แล้ว
Miller/Nordyn Oil burner Tune Up/Maintenance/Cleaning/Service/Mobile home
Bradford White Heat Pump Water Heater T2 Tank Sensor Failed!!! 😭
มุมมอง 231ปีที่แล้ว
Bradford White Heat Pump Water Heater T2 Tank Sensor Failed!!! 😭
York Ground Packaged Hvac Unit Recall?!?!
มุมมอง 88ปีที่แล้ว
York Ground Packaged Hvac Unit Recall?!?!
FORD TRANSIT/SERVICE/HVAC VAN/WALK THROUGH/TOUR/MILWAUKEE PACK OUT!!! 😁
มุมมอง 6Kปีที่แล้ว
FORD TRANSIT/SERVICE/HVAC VAN/WALK THROUGH/TOUR/MILWAUKEE PACK OUT!!! 😁
Remove Air Out Of Heating Zones/Purge/Flush/Bleed 🤔
มุมมอง 46ปีที่แล้ว
Remove Air Out Of Heating Zones/Purge/Flush/Bleed 🤔

ความคิดเห็น

  • @asegarra5279
    @asegarra5279 15 วันที่ผ่านมา

    Nice work. What kind of spray did you use when cleaning the nozzle line assembly?

  • @martinheatingcoolingmartin4693
    @martinheatingcoolingmartin4693 หลายเดือนก่อน

    A very short snap shot of the test!

  • @RADIUMGLASS
    @RADIUMGLASS 2 หลายเดือนก่อน

    It's better to leave it.

  • @RADIUMGLASS
    @RADIUMGLASS 2 หลายเดือนก่อน

    They last a long time.

  • @kennymarshall7408
    @kennymarshall7408 2 หลายเดือนก่อน

    I had one in my house. It kept the house toasty.

    • @martinheatingcoolingmartin4693
      @martinheatingcoolingmartin4693 2 หลายเดือนก่อน

      Ok. Nice to know, I just posted that video I’m surprised so fast. Somebody already recognizes it and even had one lol

  • @martinheatingcoolingmartin4693
    @martinheatingcoolingmartin4693 2 หลายเดือนก่อน

    Doing a quote to replace this beast! Pray for me, lol

  • @martinheatingcoolingmartin4693
    @martinheatingcoolingmartin4693 2 หลายเดือนก่อน

    Just to answer all your questions and comments, that control has failed. Versus buying and installing a new control we’re going to adapt it like a regular boiler, do away with that control. that control serves no purpose except maybe outdoor reset if you have an outdoor sensor, but there is no outdoor sensor and you can do that with other controls as well if you wanted to. Keep it normal, that control is useless. Unless you were going to use that control to its full benefit. If you’re not, you’ve wasted your money on that Control.

  • @furiousfill4593
    @furiousfill4593 2 หลายเดือนก่อน

    Pro TIP. Only purge if air in line. REMEBER New clean water bad. When in boiler it will create air as it heats up, causing AIR in system. DIRTY (BLACK and smells) Good ALL the AIR is out of that water. BEST SOLVE is a MALLORY LOOP (Put Micro bubble air scoop on an INVERTED TRAP Before hitting Main Header Or Loop. Your Welcome :)

  • @martinheatingcoolingmartin4693
    @martinheatingcoolingmartin4693 2 หลายเดือนก่อน

    1400 RPM max for the motor. I’m not sure what CFM that would be. I obviously only wanted 1200 CFM max. I meant I didn’t want it up to 1400 CFM.

  • @martinheatingcoolingmartin4693
    @martinheatingcoolingmartin4693 2 หลายเดือนก่อน

    From the owner: I Dumped that 5 gallon bucket once so probably about 7 1/2 gallons in that tank

  • @martinheatingcoolingmartin4693
    @martinheatingcoolingmartin4693 2 หลายเดือนก่อน

    Read This: That was not completely accurate, because that’s the long way to thaw the evaporator coil, after the belt wore off. Close up that panel turn the unit back on turn off the AC and run the fan only it will thaw real soon!

  • @deborahherrera6233
    @deborahherrera6233 2 หลายเดือนก่อน

    What year unit is this? I had a 2.5 ton installed less than 3 month ago and I smelt electrical burn inside my house and later figured out it was the unit and the circuit breaker won't kick back on.

  • @ridemfast7625
    @ridemfast7625 3 หลายเดือนก่อน

    Spaghetti mess. How many years does flex duct last?

    • @martinheatingcoolingmartin4693
      @martinheatingcoolingmartin4693 3 หลายเดือนก่อน

      That’s a good question. I guess it depends on the environment that it is in. A great environment like dry. no mice and no sun. I’d say should last 20 years but like this place the basement is very damp and moist and the old gray flex does not hold up as long. Sometimes the insulation in between breaks down or the liner breaks down sometimes you can’t tell that is 24 years old, roughly.

  • @carboncollapse8435
    @carboncollapse8435 3 หลายเดือนก่อน

    I just had one of these. I didn't see any cleanouts on it. Are there any? Didn't see a test hole for an efficency test either

    • @martinheatingcoolingmartin4693
      @martinheatingcoolingmartin4693 3 หลายเดือนก่อน

      You are correct. There are no clean outs and no test hole either. You’d need to pull the burner, and take apart the insert and gaskets. But it’s only necessary if the chamber needs replacing. Otherwise I wouldn’t touch it.

  • @PilotInCommand777
    @PilotInCommand777 3 หลายเดือนก่อน

    Good morning, I enjoyed watching. Nice how thorough you did the job, even wiping excess grime. I installed a Fujitsu 12000btu ductless mini split purchased from our local Johnstone supply 8-9 years ago and it just runs. No issues. I am located in the California desert and it does get hot here. Is there any maintenance these need or that you suggest? I called a local hvac guy for a so called tune-up and all he did was try to convince me to replace the whole unit. His reason was, it is old and could go out anytime.... Thanks and again, nice job!

    • @martinheatingcoolingmartin4693
      @martinheatingcoolingmartin4693 3 หลายเดือนก่อน

      Nice response, thanks. I definitely say at that age it’s not ready yet. But I do understand your need for cooling over there is very important. But do a good cleaning with a hose like I did on the outside unit. Then use a hand held sprayer for the indoor coil. Clean you air filter monthly. Plus try to run water through the drain of the indoor coil. But that should happen anyway if you use enough water for the coil. Use some viper foaming coil cleaner spray on coils prior to spraying water on them. Wait a couple minutes for it to soak and then rinse them well. God speed!

  • @CadillacGregg309
    @CadillacGregg309 3 หลายเดือนก่อน

    I live in St Pete, Florida and have a 1.5 Ton system for my 1 bedroom 1 bathroom 680 sq ft Condo. They want 10K to 13K to replace my NCPE through the wall condensing unit, indoor evaporator coil, and gas furnace. I think that's ridiculous but yours is a 3-ton system.

    • @martinheatingcoolingmartin4693
      @martinheatingcoolingmartin4693 3 หลายเดือนก่อน

      Thanks for the input. That does sound high for a small tonnage, but I’m not as familiar with business down there or that type of unit. Unless it’s a gas package unit you’re talking about? That one I worked on is actually a 4 ton come to find out. Thanks for the response!

  • @ayoutubewatcher7009
    @ayoutubewatcher7009 4 หลายเดือนก่อน

    Somebody makes big bucks,, I’m jealous

  • @fillowtree5505
    @fillowtree5505 10 หลายเดือนก่อน

    Nice setup and subscribed!

  • @eprohoda
    @eprohoda 11 หลายเดือนก่อน

    ‘supp?-you made unreal masterpiece~🤙

    • @martinheatingcoolingmartin4693
      @martinheatingcoolingmartin4693 11 หลายเดือนก่อน

      Thanks man I just made another one as I’m traveling back and I’m in construction on the highway. It is the life. Let me tell ya

  • @dsolocrowb9657
    @dsolocrowb9657 11 หลายเดือนก่อน

    How you going to water that tree

    • @martinheatingcoolingmartin4693
      @martinheatingcoolingmartin4693 11 หลายเดือนก่อน

      Tell me about it the customer did not want to remove the tree now that the radian is done. They’re going to pour a slab in the footing all in one, and then that’s gonna be all enclosed has an addition on grade.

    • @mattwernecke2342
      @mattwernecke2342 หลายเดือนก่อน

      How much electricity does that use?

    • @martinheatingcoolingmartin4693
      @martinheatingcoolingmartin4693 หลายเดือนก่อน

      @mattwernecke2342 it’s a hot water hydronic system. It’s not electric heat.

  • @laust3998
    @laust3998 11 หลายเดือนก่อน

    Neat looks like lego

  • @chrissipple1018
    @chrissipple1018 ปีที่แล้ว

    One problem it's a York. The screens are for emissions to cut down on non and to help form the flame into a spiral or twist.

    • @martinheatingcoolingmartin4693
      @martinheatingcoolingmartin4693 ปีที่แล้ว

      Thanks for the comment. I appreciate the information, that’s kinda what I figured. But, wasn’t positive. Thanks again.

  • @martinheatingcoolingmartin4693
    @martinheatingcoolingmartin4693 ปีที่แล้ว

    That pump pulled the 48k Samsung heat pump with 5 heads and 185 feet of line set total, down to 250 microns in half hour or less. With a 8.0 battery.

  • @martinheatingcoolingmartin4693
    @martinheatingcoolingmartin4693 ปีที่แล้ว

    I said field piece gauge, I meant scale. Also, I noticed the video is small and square. Turn phone and put it on full screen for larger view, thanks!